Loading...
HomeMy WebLinkAboutNCC216007_Site Plan or Location Map_20211028CIVIL SITE PLANS: CIRCLE K - NTI BAYSWATER GREENVILLE - NCO123 950 E FIRE TOWER ROAD, GREENVILLE, NORTH CAROLINA 28590 ARCHITECT: RDC RALPH WATSON 11921 FREEDOM DRIVE, SUITE #1100 RESTON, VA 20190 RALPH.WATSON@RDCOLLABORATIVE.COM P H : (703) 659-8252 OWNER: FIRETOWER OP LLC 1515 RINGLING BLVD, SUITE #809 SARASOTA, FL 34236 SITE PLAN SUMMARY PROJECT: CIRCLE K - NTI BAYSWATER GREENVILLE - NC.123 OWNER: FIRETOWER OP LLC PROJECT ADDRESS: 950 E FIRE TOWER ROAD, GREENVILLE, NC 28590 PIN: 79547 JURISDICTION: GREENVILLE EXISTING USE: VACANT PROPOSED USE: CONVENIENCE STORE W/ GAS SALES AND OUTDOOR SEATING LOCATED IN FLOOD HAZARDS AREA PER FEMA MAP #3720468600K FLOOD ZONE: (EFFECTIVE 07/07/2014) PROPOSED TRACT 2.2 AC (95,615 SF) AREA: DISTURBED AREA: 2.1 AC ZONING: CG (GENERAL COMMERCIAL) COMMON AREAS: N/A RECREATION AREAS: N/A TOTAL NUMBER OF N/A UNITS/BEDROOMS: GROSS FLOOR AREA: 5,200 SF BUILDING LOT COVERAGE (EXISTING 5,200 SF AND PROPOSED): PROPOSED BUILDING 23' - 0" HEIGHT: CONVENIENCE STORES W/ GAS SALES: 1 SPACE PER 300 SQUARE FEET OF GFA = VEHICLE PARKING 5,200 SF / 300 SF = 18 SPACES SUMMARY: REQUIRED 1.5 SPACES PER FUELING STALL: 1.5 X 14 = 21 SPACES; TOTAL = 39 SPACES 34 PARKING SPACES VEHICLE PARKING 2 ADA SPACES (1 IS VAN ACCESSIBLE) SUMMARY: PROVIDED 14 FUELING SPACES TOTAL: 50 SPACES TOTAL NUMBER OF REQUIRED: 2 SPACES HANDICAP PARKING PROVIDED: 2 SPACES SPACES: EXISTING IMPERVIOUS 1,368 SF (1.4%) SURFACE AREA: DRAINAGE AREA TO BE TREATED: 1.799 AC ALLOCATED TOTAL IMPERVIOUS AREA TO BE TREATED: 66,619 SF ALLOCATED ALLOCATED BUILDING AREA TO BE TREATED: 19,334 SF STORMWATER: ALLOCATED TRANSPORTATION AREA TO BE TREATED: 47,285 SF ASSIGNED MANAGED PERVIOUS AREA TO BE TREATED: 11,757 SF PROPOSED IMPERVIOUS SURFACE 51,401 SF (1.18 AC) AREA: PROPOSED % 53.6% IMPERVIOUS TYPE OF BUILDING CONVENIENCE STORE: V-B (NON-SPRINKLERED) CONSTRUCTION: TYPE OF CANOPY II-B CONSTRUCTION: City of Greenville Site Plan Approval Date 0 Approved 0 Approved as Noted Surveyor/Floodplain Inspections Fire/Rescue GUC electric GUC water/sewer GUC gas NCDOT Vegetation Traffic Services Notes *Site plan approval ONLY. Engineer/Architect/Surveyor shall be responsible for adequacy of design, errors or omissions in the plans. All plans shall meet all specifications, standards and applicable regulations. PITT COUNTY DEVELOPER: CIRCLE K STORES INC ANDY PRIOLO 1100 SITUS COURT, SUITE #100 RALEIGH, NC 27606 PH: (919) 566-1714 FAX (919) 777-5139 P4\611_0 0 O� 00 O 0 SITE -//0 N� �,A VICINITY MAP NTS CITY OF GREENVILLE LANDSCAPE REQUIREMENTS M co 0 Q z CIVIL ENGINEER: TIMMONS GROUP 5410 TRINITY ROAD SUITE #102 RALEIGH, NC 27607 PROJECT MANAGER BRIAN W. DOWNS BRIAN. DOWNS@TlMMONS.COM PH: (919) 866-4504 ENGINEER OF RECORD RICK BAKER, P.E. RICK. BAKER@TlMMONS.COM PH: (919) 866-4939 SURVEYOR: TIMMONS GROUP MARC SNIDER, PLS 5410 TRINITY ROAD SUITE #102 RALEIGH, NC 27607 PH: (984) 255-2364 MARC. SNIDER@TIMMONS.COM REVISION TABLE C0.0 REVISIONS TO TABLES & NOTES C0.1 SHEET ADDED C1.0 REVISIONS TO NOTES C2.0 REVISIONS TO LAYOUT, C&G, ADA RAMPS, BUFFERS, GENERAL NOTE #6 & EASEMENTS C2.1 REVISIONS TO SIDEWALK HATCHING C3.0 REVISIONS TO GRADING & STORM NETWORK C3.1 REVISIONS TO GRADING & STORM NETWORK C4.0 REVISIONS TO LOD & NOTE ADDED C5.0 NOTES ADDED C6.0 REVISIONS TO PLANTINGS & LANDSCAPE REQUIREMENTS; NOTES ADDED C7.1 SIDEWALK DETAIL ADDED C7.3 DETAILS ADDED C7.4 REVISIONS TO PAVEMENT SECTIONS C7.7 DETAIL ADDED AREA REQUIREMENT CALCULATION/REQUIRED PROVIDED SITE VEGETATION MATERIAL LANDSCAPE PER ACRE 2.2 * 5 = 11 LARGE TREES 11 LARGE TREES REQUIREMENT (PER ACRE) 5 LARGE TREES 2.2 * 10 = 22 SMALL TREES 22 SMALL TREES (2:1 SUBSTITUTE (STREET TREES COUNT TOWARDS 10 SMALL TREES 2.2 * 25 = 55 SHRUBS LARGE TREES FOR SMALL) THESE REQUIREMENTS) 25 SHURBS 69 SHRUBS PERIMETER LANDSCAPE: STREET YARD 371 / 100 * 2 = 8 LARGE TREES 8 LARGE TREES EAST FIRETOWER ROAD 371 LF 2 LARGE TREES PER 100 LF PERIMETER LANDSCAPE: STREET YARD 291 / 100 *2 = 6 LARGE TREES 6 LARGE TREES BAYSWATER ROAD 291 LF 2 LARGE TREES PER 100 LF PERIMETER LANDSCAPE: LANDSCAPE BUFFER TYPE 'E' 331 / 100 * 6 = 20 EVERGREEN 15 EVERGREEN TREES (5 TREE 331 LF REAR YARD 6 EVERGREEN TREES PER 100 LF TREES CREDIT FOR EXISTING VEG.) 8 SMALL EVERGREEN TREES PER 100 LF 331 / 100 * 8 = 27 SMALL 26 EVERGREEN SHRUBS PER 100 LF EVERGREEN TREES 23 SMALL EVERGREEN TREES (4 331 / 100 * 26 = 86 EVERGREEN TREE CREDIT FOR EXISTING VEG.) SHRUBS 76 EVERGREEN SHRUBS (10 SHRUB CREDIT FOR EXISTING VEG.) PARKING AREA VEGETATION ALL SPACES WITHIN 75 FEET OF A N/A SEE PLAN FOR TREE RADII LABELS REQUIREMENTS LARGE TREE OR WITHIN 30 FEET OF A SMALL TREE SHRUB HEDGES HAVE BEEN PROVIDED WHERE PARKING PARKING SCREENING: 30" HT FRONTS A STREET CONTINUOUS SHRUB HEDGE CITY OF GREENVILLE GENERAL NOTES: Sheet List Table Sheet Number Sheet Title C0.0 COVER SHEET C0.1 ALTA - NSPS LAND TITLE SURVEY C ING I ONS A C1.1 DEMOLITION PLAN C2.0 SITE LAYOUT PLAN C2.1 PAVING PLAN C2.2 VEHICULAR ROUTING PLAN C3.0 GRADING & DRAINAGE PLAN C3.1 SPOT GRADING PLAN C4.0 EROSION CONTROL PLAN - PHASE I C4.1 EROSION CONTROL PLAN - PHASE II C4.2 NPDES STABILIZATION PLAN C4.3 NPDES NOTES AND DETAILS C5.0 UTILITY PLAN C5.1 UTILITY SERVICES PLAN AND PROFILE C6.0 LANDSCAPING PLAN C7.0 DETAIL SHEET C7.1 DETAIL SHEET C7.2 DETAIL SHEET C7.3 DETAIL SHEET C7.4 DETAIL SHEET C7.5 DETAIL SHEET C7.6 DETAIL SHEET C7.7 DETAIL SHEET C7.8 DETAIL SHEET C7.9 DETAIL SHEET L1.0 SITE LIGHTING PLAN L2.0 SITE LIGHTING DETAILS IR-1 IRRIGATION PLAN IR-2 IRRIGATION DETAILS 1. NCDOT DRIVEWAY PERMIT REQUIRED. 2. AN UNUSED DRIVEWAY MUST BE CLOSED IN ACCORDANCE WITH THE CITY OF GRE RIVEWAY ORDINANCE. 3. CONTRACTOR MUST NOTIFY ONE -CALL CENTER INC. (NC ONE -CALL) (811) AT LEA T 72 HOURS RIOR TO THE START OF EXCAVATION OR TRENCHING TO HAVE ALL UNDERGROUND UTILITIES LOCATED. 4. ALL REQUIRED IMPROVEMENTS SHALL CONFORM TO THE CITY OF GREENVILLE MANUAL OF STANDARD DESIGNS AND DETAILS (MSDD). 5. CONTRACTOR SHALL NOTIFY PUBLIC WORKS, STREET MAINTENANCE DIVISION 48 HOURS PRIOR TO MAKING CONNECTIONS TO EXISTING STORM THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA AS DETERMINED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. THIS PROPERTY IS LOCATED IN ZONE(S) "AE", AS SHOWN ON FIRM PANEL NUMBER 3720468600K, COMMUNITY NUMBER 370191, INDEX DATE JULY 7, 2014. A UNLESS OTHERWISE PERMITTED BY THE TRAFFIC ENGINEER. IN ADDITION, THERE WILL BE NO LANE CLOSURES ON HOLIDAYS INCLUDING THE DAY BEFORE OR AFTER SAID HOLIDAY. A TRAFFIC CONTROL PLAN PREPARED IN ACCORDANCE WITH THE NCDOT MANUAL OF UNIFORM TRAFFIC 8. CONTACT CITY OF GREENVILLE ENGINEERING DEPT. AT (252) 329-4522 FOR PRE -POUR INSPECTION PRIOR TO POURING VALLEY GUTTER AND CURB IN R/W. 9. ALL SITE LIGHTING SHALL COMPLY WITH THE CITY OF GREENVILLE LIGHTING STANDARD. 10. R/W EXCAVATION AND RESTORATION PERMIT REQUIRED. CONTACT GENTRY COWARD AT (252) 329-4050 FOR PERMIT. 11. PLEASE BE ADVISED OF THE RULES WHICH PROTECT AND MAINTAIN EXISTING BUFFERS ALONG WATERCOURSES IN THE NEUSE AND TAR/PAMLICO RIVER BASINS. THIS RULE IS ENFORCED BY THE DIVISIONS ON WATER QUALITY (DWQ). DIRECT ANY QUESTIONS ABOUT THE APPLICABILITY OF THIS RULE TO YOUR PROJECT TO ROGER THORPE, REGIONAL WATER QUALITY SUPERVISOR, WASHINGTON REGIONAL OFFICE, AT (919) 946-6481. GENERAL NOTES: 1. IT SHALL BE UNLAWFUL FOR ANY PERSON TO MAKE ANY EXCAVATION OR DO ANY OTHER WORK WHICH MAY CAUSE A DANGEROUS CONDITION IN OR ON ANY STREET, ALLEY, SIDEWALK, PUBLIC WAY OR PUBLIC PLACE IN THE CITY, UNLESS A WRITTEN PERMIT IS FIRST OBTAINED FROM AN OFFICER OF THE CITY VESTED WITH AUTHORITY TO GRANT THE SAME. NO PERMIT SHALL BE ISSUED IN ANY CASE WHERE A BOND IS REQUIRED, UNTIL A BOND SHALL HAVE BEEN EXECUTED. 2. ALL CONTRACTORS SHALL VISIT THE PROJECT TO FAMILIARIZE THEMSELVES WITH SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. BY SUBMITTING A BID, THE CONTRACTOR AND HIS SUBCONTRACTORS ARE CONFIRMING THAT THEY HAVE VISITED THE SITE AND HAVE T I I S F I I I O 3. NEW BUILDINGS MUST COMPLY WITH NC FIRE CODE SECTION 510 - EMERGENCY RESPONDER RADIO COVERAGE. 4. ALL EXISTING VEGETATION TO BE VERIFIED AT TIME OF FINAL INSPECTION. 3. THE PROPERTY OWNER AGREES INTERNAL DRIVEWAYS AND ROADS WILL BE CONSTRUCTED AS SHOWN ON THE ATTACHED SITE PLAN. THE LANDOWNER AGREES TO RESTRICTED INTERNAL ACCESS WITHOUT INTERNAL MEDIANS. THIS AGREEMENT SHALL CARRY FORTH WITH ANY SUBDIVISIONS OR LAND TRANSFERS. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL CITY OF GREENVILLE, GREENVILLE UTILITY COMMISSION, NCDEQ, AND NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS C ARO // / SS/0 � Q 0 530 _ FNOIN�F� 10/22/21 E 0 U vi o � � o N E w U E z Q CD Z �LU U a N LL LU M Z LU ON J x < W ra LL Ln L I0 F� o O" L� J W 0 Ln l0 ►13 �13 U) z U) � w w 0 w O 2:U w O LU U O J U a z OU) U wLU W W O LU J J_ H > UU � 0 LU(7U)U> w O w p z w � z O mC� LU U O a- (3 UU LU z�a a LUO a- U) U) z 0 O � Z O � 0 > U) >LU wLU ­1 ­1 ­1 ­1 w N N N N N 01 O Ul l0 N Q O i i i N DATE 0510712021 D RAW N BY A. MAY DESIGNED BY B. DOWNS CHECKED BY R. BAKER SCALE AS SHOWN M N Q � z J ■ O U U z= O z Uj z a0 °w W a = W w W J aJ z W co w LU I --I LU O U z< O W O LU w U" w cl. O Ln I­4 M U JOB NO. 7630.060 SHEET NO C0.0 L