HomeMy WebLinkAbout20200398 Ver 2_ePCN Application_20211027fr.,f DW R
mrlsloa of ware. Resources
Pre -Construction Notification (PCN) Form
For Nationwide Permits and Regional General Permits
(along with corresponding Water Quality Certifications)
June 1, 2021 Ver 4.1
Initial Review
Has this project met the requirements for acceptance in to the review process?*
Yes
No
Is this project a public transportation project?*
Yes No
Change only if needed.
BIMS # Assigned*
20200398
Is a payment required for this project?
No payment required
Fee received
Fee needed - send electronic notification
Reviewing Office*
Fayetteville Regional Office - (910) 433-3300
Information for Initial Review
1a. Name of project:
Cotton Farms
la. Who is the Primary Contact?*
Clint Reese
1 b. Primary Contact Email: *
reeseconstruction@hotmaii.com
Date Submitted
10/27/2021
Nearest Body of Water
Hectors Creek
Basin
Cape Fear
Water Classification
Class-WS-IV, HOW
Site Coordinates
Latitude:
35.502398
A. Processing Information
County (or Counties) where the project is located:
Harnett
Is this a NCDMS Project
Yes No
Is this project a public transportation project?*
Yes No
Pre -Filing Meeting Information
Longitude:
-78.853832
Version# *
2
What amout is owed?*
$240.00
$570.00
Select Project Reviewer*
Chad Turlington:eads\ccturlington
1c. Primary Contact Phone:*
(919)329-5501
Is this a courtesy copy notification?*
Yes No
ID#
Version
Pre -fling Meeting or Request Date
9/20/2021
Attach documentation of Pre -Filing Meeting Request here:
Click the upload button or drag and drop files here to attach document
NCDWR Pre -Filing Meeting Request Cotton Farms_20210920.pdf
File type must be PDF
1a. Type(s) of approval sought from the Corps:
Section 404 Permit (wetlands, streams and waters, Clean Water Act)
Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act)
Has this PCN previously been submitted?
Yes
No
1 b. What type(s) of permit(s) do you wish to seek authorization?
Nationwide Permit (NWP)
Regional General Permit (RGP)
Standard (IP)
1c. Has the NWP or GP number been verified by the Corps?
Yes No
Nationwide Permit (NWP) Number:
NWP Numbers (for multiple NWPS):
1d. Type(s) of approval sought from the DWR:
401 Water Quality Certification - Regular
Non-404 Jurisdictional General Permit
Individual 401 Water Quality Certification
29 - Residential Developments
le. Is this notification solely for the record because written approval is not required?
For the record only for DWR 401 Certification:
For the record only for Corps Permit:
1f. Is this an after -the -fact permit application?"
Yes No
1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts?
Yes No
1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts?
Yes No
1 If. Is the project located in any of NC's twenty coastal counties?
Yes No
1j. Is the project located in a designated trout watershed?
Yes No
B. Applicant Information
1d. Who is applying for the permit?
Owner Applicant (other than owner)
le. Is there an Agent/Consultant for this project?"
Yes No
2. Owner Information
2a. Name(s) on recorded deed:
Reese Construction, LLC
2b. Deed book and page no.:
B3912 - P977 and B3913-P911
2c. Contact Person:
Clint Reese
111.95KB
401 Water Quality Certification - Express
Riparian Buffer Authorization
Yes No
Yes No
2d.Address
Street Address
3720 Lucky Drive
Address Line 2
City
Apex
Postal / Zip Code
27539
2e. Telephone Number:
(919)329-5501
2g. Email Address:*
reeseconstruction@hotmail.com
4. Agent/Consultant (if applicable)
4a. Name:
Krissina Newcomb
4b. Business Name:
Hal Owen & Associates Inc
4c.Address
Street Address
PO Box 400
Address Line 2
City
Lillington
Postal / Zip Code
27546
4d. Telephone Number:
(910)893-8743
4f. Email Address:
Krissina@halowensoil.com
C. Project Information and Prior Project History
1. Project Information
1b. Subdivision name:
(if appropriate)
Cotton Farms
1c. Nearest municipality / town:
Fuquay-Varina
2. Project Identification
State / Province / Region
INC
Country
us
2f. Fax Number:
State / Province / Region
INC
Country
us
4e. Fax Number:
(910)893-3594
2a. Property Identification Number:
2b. Property size:
0643-36-2905, 0643-27-3733, 0643-48-3310
161
2c. Project Address
Street Address
Cotton Road
Address Line 2
City
State / Province / Region
Fuquay-Varina
INC
Postal / Zip Code
Country
27526
us
3. Surface Waters
3a. Name of the nearest body of water to proposed project:
Hectors Creek
3b. Water Resources Classification of nearest receiving water:*
Class-WS-IV, HOW
3c. What river basin(s) is your project located in?*
Cape Fear
3d. Please provide the 12-digit HUC in which the project is located.
03030004-0502
4. Project Description and History
4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:'
The site is mostly wooded and partially agricultural field. Land use in the vicinity is agricultural, residential, and wooded.
4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?*
Yes No Unknown
4f. List the total estimated acreage of all existing wetlands on the property:
15
4g. List the total estimated linear feet of all existing streams on the property:
5240
4h. Explain the purpose of the proposed project:"
Construct a single-family residential subdivision connected by a road and utilities (133 Lots)
4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used: *
Vegetation within the road right of way will be cleared and the road bed graded. Where the proposed road crosses the stream and wetland (see construction sheets 7, 8, and 9), a 98ft long
54" RCP will be buried 1 ft below the stream bottom. An 18ft long dissipater pad will be added at the outlet, 24" deep of 13" stone. A 32 ft long rip -rap energy dissipation pad will be
installed at the outlet of the culvert.
Water lines will be concurrently installed in the road right-of-way. The area will be back filled, the roadway paved, and side slopes stabilized.
Typical construction equipment such as excavators, loaders, dump trucks, and graders will be utilized.
5. Jurisdictional Determinations
5a. Have the wetlands or streams been delineated on the property or proposed impact areas?*
Yes No Unknown
Comments
5b. If the Corps made a jurisdictional determination, what type of determination was made?*
Preliminary Approved Not Verified Unknown N/A
Corps AID Number:
5c. If 5a is yes, who delineated the jurisdictional areas?
Name (if known): Krissina Newcomb
Agency/Consultant Company: Hal Owen & Associates, Inc.
Other:
6. Future Project Plans
6a. Is this a phased project?*
Yes No
6b. If yes, explain.
The proposed road impact will occur in Phase 1 of the development. Future phases have been designed to avoid wetlands, and no additional permits are anticipated.
Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity?
No
D. Proposed Impacts Inventory
1. Impacts Summary
1a. Where are the impacts associated with your project? (check all that apply):
Wetlands Streams -tributaries Buffers
Open Waters Pond Construction
2. Wetland Impacts
2a1 Reason M
2b. Impact type* (?)
2c. Type of W.*
2d. W. name*
2e. Forested*
2f. Type of Jurisdicition*
2g. Impact
area
ff��
road crossing JP
Headwater Forest 7A
Yes
Both
0.323
(acres)
2g. Total Temporary Wetland Impact 2g. Total Permanent Wetland Impact
0.000 0.323
2g. Total Wetland Impact
0.323
2i. Comments:
3. Stream Impacts
S1
3a. Reason for impact (?)
Road Crossing
36.Impact type
Permanent
3c. Type of impact"
Culvert
3d. S. name"
S-A
3e. Stream Type"
?)
Perennial
3f. Type of
Jurisdiction*
Both
3g. S. width'
Average (feet)
3h. Impact
length*
123
Qinear feet)
gy
Road Crossing
Permanent
Rip Rap Fill
S-A
Perennial
Both
Average (feet)
32
Qinear feet)
3i. Total jurisdictional ditch impact in square feet:
0
3i. Total permanent stream impacts:
155
3i. Total stream and ditch impacts:
155
3j. Comments:
E. Impact Justification and Mitigation
1. Avoidance and Minimization
3i. Total temporary stream impacts:
0
la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project:
Wetlands were excluded from all lots and are reserved in the Open Space.
Headwalls will be used at the culvert to minimize culvert length at the road crossing.
Shoulder slopes at the road crossing will be graded at 2 to 1.
The road was sited nearly perpendicular to the drainageway to minimize impacts.
The road alignment in future phases was adjusted to avoid wetland impacts.
Detention basins and stormwater controls were sited completely outside of wetland areas.
The culvert will be buried to maintain aquatic passage and to maintain passage during drought or low flow conditions. (1ft depth for 48" diameter or
more, 20 % for less than 48" diameter)
A road crossing was eliminated in the southeastern end of the site by replacing it with a cul-de-sac.
Utilities will be grouped in the road right-of-way to avoid additional impacts.
1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques:
Sediment and erosion control measures will be used, such as silt fencing, to protect water quality. Construction limits will be clearly marked through
wetlands. No clearing will occur in wetlands outside of the proposed impact area. Construction and fill materials will be stored in upland areas.
2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State
2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State?
Yes
No
2c. If yes, mitigation is required by (check all that apply):
DWR Corps
2d. If yes, which mitigation option(s) will be used for this project?
Mitigation bank Payment to in -lieu fee program Permittee Responsible Mitigation
4. Complete if Making a Payment to In -lieu Fee Program
4a. Approval letter from in -lieu fee program is attached.
Yes No
4b. Stream mitigation requested:
(linear feet)
0
4d. Buffer mitigation requested (DWR only):
(square feet)
0
4c. If using stream mitigation, what is the stream temperature:
4e. Riparian wetland mitigation requested:
(acres)
0.646
4f. Non -riparian wetland mitigation requested: 4g. Coastal (tidal) wetland mitigation requested:
(acres) (acres)
0 0
u
4h. Comments
F. Stormwater Management and Diffuse Flow Plan (required by DWR)
1. Diffuse Flow Plan
la. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules?
Yes No
If no, explain why:
Cape Fear River Basin (HUC 03030004) is not subject
2. Stormwater Management Plan
2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?*
Yes No
2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)?
Yes No
2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government Stormwater program?
Yes No
N/A - project disturbs < 1 acre
2d. Which of the following stormwater management program(s) apply:
Local Government State
State Stormwater Programs
Phase II Coastal Counties
HWQ or ORW Other
Comments:
G. Supplementary Information
1. Environmental Documentation
la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?*
Yes No
2. Violations (DWR Requirement)
2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or
Riparian Buffer Rules (15A NCAC 2B .0200)? *
Yes No
3. Cumulative Impacts (DWR Requirement)
3a. Will this project result in additional development, which could impact nearby downstream water quality?
Yes No
3b. If you answered "no," provide a short narrative description.
This residential development is relatively small and will not likely affect regional growth patterns.
4. Sewage Disposal (DWR Requirement)
4a. Is sewage disposal required by DWR for this project?*
Yes No N/A
4b. Describe, in detail, the treatment methods and dispositions (non -discharge or discharge) of wastewater generated from the proposed project. If the wastewater will be treated at a
treatment plant, list the capacity available at that plant.
onsite subsurface sewage waste disposal, each system designed to treat and dispose of 360 to 480 gallons of effluent per day
5. Endangered Species and Designated Critical Habitat (Corps Requirement)
5a. Will this project occur in or near an area with federally protected species or habitat?*
Yes No
5b. Have you checked with the USFWS concerning Endangered Species Act impacts?*
Yes No
U
5c. If yes, indicate the USFWS Field Office you have contacted.
Raleigh
5d. Is another Federal agency involved?*
Yes No
5e. Is this a DOT project located within Division's 1-8?
Yes No
5f. Will you cut any trees in order to conduct the work in waters of the U.S.?
Yes No
5g. Does this project involve bridge maintenance or removal?
Yes No
5h. Does this project involve the construction/installation of a wind turbine(s)?*
Yes No
Unknown
51. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.?
Yes No
5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat?
US FWS iPaC (https://ecos.fws.gov/ipac/)
NC Natural Heritage Program (https://ncnhde.natureserve.org/)
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as an Essential Fish Habitat?
Yes No
6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?
NOAA Habitat Conservation National Marine Fisheries Service
hftps://www.habitat.noaa.gov/apps/efhmapper/
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?*
Yes No
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?*
NC State Historic Preservation Office (http://gis.ncdcr.gov/hpoweb/
8. Flood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA-designated 100-year floodplain?*
Yes No
8c. What source(s) did you use to make the floodplain determination?*
NC Flood Risk Information System (https:/Ifris.nc.gov/fris/ )
Miscellaneous
Please use the space below to attach all required documentation or any additional information you feel is helpful for application review. Documents should be combined into one file when
possible, with a Cover Letter, Table of Contents, and a Cover Sheet for each Section preferred.
Click the upload button or drag and drop files here to attach document
Cotton Farms—PCN Attachment.pdf 35.73MB
File must be PDF or KMZ
Comments
Signature
By checking the box and signing below, I certify that:
• The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief'; and
• The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time.
• I have given true, accurate, and complete information on this form;
• I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act");
• I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act");
• I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND
• I intend to electronically sign and submit the PCN form.
Full Name:
Krissina Newcomb
Signature
wsalz fWA4
Date
10/27/2021