Loading...
HomeMy WebLinkAboutNC0086550_Inspection_20140414ATA North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary April 14, 2014 Linda Vause, Town Manager Town of Fairmont PO Box 248 Fairmont NC 283400248 SUBJECT: April 8, 2014 Compliance Evaluation Inspection Town of Fairmont Fairmont Regional WWTP Permit No: NC0086550 Robeson County Dear Ms. Vause: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on April 8, 2014. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The cooperation of Mr. Dennis Freeman, Facility ORC, Mr. Kevin Taylor, Facility Operator, and Mr. Johnny Britt, Part Time Consultant, was greatly appreciated. The facility was found to be in Compliance with permit NC0086550. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. o Maintenance records, ORC log books, and laboratory records appeared to be in order at the time of the inspection. o At clarifier number 1 it was noted that there is a hole in the baffle wall that is allowing water to go under the baffle and the weir plate instead of over them. Operations staff is unable to repair it at this time due to high flows from the recent wet weather. The staff does have plans to repair it as soon as the flow returns to normal levels. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, -- Mark Brantley Environmental Senior Specialist Fayetteville Regional Office NCDENR cc: Dennis Freeman, ORC Central Files 7-Fayetteville-Files j Fayetteville Regional Office 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095 Main Phone: 910-433-3300 1 Internet: http://www.ncdenr.gov United States Environmental Protection Agency V E P ^ Washington, D.C. 20460 /� Water CompIianne Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I N 1 2 1 51 31 NC0086550 111 121 14/04/08 117 Type Inspector FacType 181 C 1 191 S I 201 11 IM 11111111 11166 Remarks 211 I I I 1111 1111111111111111 1111 IIII Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 1 69 701 1 711 I 72I N ILi 73I 1 1 74 75I I I 1 I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) • Fairmont Regional WVVTP Off US Hwy 74 Fairmont NC 28340 Entry Time/Date 10:30 AM 14/04/08 Permit Effective Date 09/11/01 Exit Time/Date 02:00 PM 14/04/08 Permit Expiration Date 14/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Dennis Freeman/ORC/910-628-0064/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Johnny J Britt,PO Box 248 Fairmont NC 283400248/Superintendent/910-628-0064/ No • Section C: Areas Evaluated During Inspection (Check only those areas evaluated) as necessary) 110 Permit x `, Flow Measurement : Operations & Maintenance `j Records/Reports and checklists Self -Monitoring Program ' Sludge Handling Disposal - Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ /�'�viA i 141—/ Signature of Management Q A Reviewer �(�!! ..-- qq --�� Agency/Office/Phone and Fax Numbers Date Belinda S Henson �' 1. 91L�ry FRO WQ//910-433-3300 Ext.726/ 9— li — i ! EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type 3 l NC0086550 111 121 14/04/08 117 181 CI (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments Facility was clean and neat in appearance at the time of the inspection. Maintenance records, ORC log books, and laboratory records appeared to be in order at the time of the inspection. At clarifier number 1 it was noted that there is a hole in the baffle wall that is allowing water to go under the baffle and the weir plate instead of over them. Operations staff is unable to repair it at this time due to high flows from the recent wet weather. The staff does have plans to repair it as soon as the flow returns to normal levels. Page # 2 Permit: NC0086550 Owner - Facility: Fairmont Regional WWTP Inspection Date: 04/08/20'14 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ®n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n n n Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, tirnes and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ?. (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE ® nnn ® nnn ® n®n ® nnn ® nnn Yes No NA NE nnn ®nnn [EL nnn ® nnn ® nnn rg0D0 ®nnn nn®n nnn ignnn nnn ®nnn Page # 3 Permit: NC0086550 Owner - Facility: Fairmont Regional WWTP Inspection Date: 04/08/2014 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Aerobic Digester Is' the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: Pump Station - Effluent Is the pump wet well free of bypass lines or structures? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Yes No NA NE ® nnn Yes No NA NE ® nnn o nnn ® nnn n nn® Yes No NA NE o nnn nnn 4nnn ®nnn ®nnn Yes No NA NE ®nnn ® nnn ®nnn ®nnn 4nnn ® nn® Yes No NA NE ® nnn ® nnn ® nnn ®nnn ®nnn ® nnn Page # 4' Permit: NC0086550 Owner - Facility: Fairmont Regional WWTP Inspection Date: 04/08/2014 Inspection Type: Compliance Evaluation Pump Station - Influent Is audible and visual alarm available and operational? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) Comment: A small section of the baffle wall in clarifer number 1 has failed allowing water to under the baffle and weir plate instead of over it. Repairs will be made when the flow level drops. Flow has been elevated due to recent wet weather. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Yes No NA NE nnn® Yes No NA NE RA • nnn Egg nnn I; nnn ® .nnn Yes No NA NE ® nnn ® nnn nnn ® nnn ®nnn nnn ® nnn ® nnn ®nnn ®nnn ® nnn Yes No NA NE Ext. Air Diffused ® nnn Page # 5 9 # abed MOOD O 0 O 0 0 cf,a}ls uo sei1ddns pue sped weds a enbepe way} e y LIeuol;eJedo sdwnd eJy 6aoeld u! sdwnd eiv 3N VN oN saA SVM-S` J-sdwnd O 0041 11000 000IE 111000 O 0 0 O U 0 U U 0 g 3N VN ON seA O E 0 O E 00 O U 0 U ='UU. O 0 0 pinbll 3N VN ON saA O 0 U O .004 u uu® 0 0 0 ME U U 0 ME O ®U O 3N VN oN saA :1uewwoa 6pwopuow lane! !an; Jo;eJeue6 ay} sl j,Jemod do-Noeq uo unu pepue xe .1o; Jopuen Ien; a y;!nn;uewaw6e i(oue6jewe ue way} sl 6a}!s JeTenne;seen w!}ue ay} eJedo o; A}loedeo elenbepe aney (s)Jo;eJeue6 ay; oa 6uo!;oadsut ay} 6upnp leuo!}wadopasse; Jo;eJeue6 seM 6peol Jepun passe} Jo;eJeue6 ay} sl 6aoJnos Jemod tiewud 6ul}dnJJa;u! Aq pa}S0} Jo;eJaue6 ay} sl �algel!ene Jannod Agpue}s pelenl;oe AIleo!}ewo;ne sl JaMod i(gpue;s :TuewwOQ Lesn u! segn;;o.egwnN c.leuo!}eJado sJo;euuo!yo-ep }a!qe; wy 6edA} pue ez!s Jedoid ay; s}ejge; ay} wy :Tuewwo0 e,sJeule}uoo auuolyo woJ; i(enne pwo;s eoue;sgns uol}euuolyo-ep sl # �s�apu!l�(o .1o; a}eudoidde e6eJo}s s! 6(1, o; ;unowe auuolyo o} leuo!podad ogee pea; Nis! wa;s.(s;o edi(1 UO40U1JO14O-0a :juewwOo (I/6w 0.£ 01 0' 6)1,01ge}deooe lane! 0a ay3 sl 681ge}deooe !anal Oa ay} sl t aoepns s,u!seq ay;Jo %9Z ueq; ssei Janoo weo; ay; seoa 6sseooid }uaw;ew; ay; .io; Joloo iedoid ay} weo; ay} sl .leuo!}eJedo sJesn};!p ay; 8Jy ,leuogeJado sJax!w pue s.1o;e.1ae aoepns 8Jy su!se8 uo!;eioy - uol;enlen3 eouelldwoO :adi(1 uol;oedsul d1MM leuol6a�l wowed :A4Ipoed - JauMO 17IOZ/80/170 :o;ea uo!;oadsul 0999900ON :;lwJad • Permit: NC0086550 Owner - Facility: Fairmont Regional WWTP Inspection Date: 04/08/2014 Inspection Type: Compliance Evaluation Pumps-RAS-WAS Comment: Disinfection -Liquid Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Upstream / Downstream Sampling Yes No NA NE Yes No NA NE ®nnn ®nnn ® nnn ® nnn ®nnn ® nnn Yes No NA NE ® n n ® nnn nnn ® nnn ®nnn ® nnn 111 Yes No NA NE ®nnn ® nnn ® nnn ® nnn ® nnn ®nnn Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: nnn Page # 7