Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0029442_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Sep; North Carolina Department of E.nvironment and Natural Resources Alan W. Klimek, P.E Di Division of Water Quah April 19, 2006 Mr. Darren Wood, Manager Beatties Ford Retail, LLC 521 East. Morehead Street Suite 100 Charlotte, NC 28202 Subject: Permit No. WQ0029442 Stewart Creek Crossing Beatties Ford Retail, LLC C .MU PROJECT #600-64-606 Mecklenburg County, North Carolina Dear Mr, Wood: In accordance with your application received on April 10, 2006, we are forwarding herewith Permit No. WQ0629442, dated April 19, 2006, to Beatties Ford Retail, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, )r Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H ,0227 or any individual system -wide collection system permit issued to the Permittee, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Perrrmittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. M rcav°ille Regional ()nice 610 East Center Ave.„ Suite 301 lnreeaseil1e, Internet www.rtcwaterquality_org Customer Service: I-8'77-623-6748 An Equal 0pportunitylAfirnnative Action Employer — 50% Recycled/10% Post Consumer Paper NC 211115 Phone: (704) 663.1699 Fax: (704) 663-6040 Nt r` hCarolina atura!!y Mr. Darren Wood Page 2 April 19, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Beatties Ford Retail, LLC for the construction and operation of approximately 242 linear feet of 2-inch force main and a 29 gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms and wet well storage, as part of the Stewart Creek Crossing project, and the discharge of 11,272 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the application received April 10, 2006, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (Irwin Creek NPDES No. NC0024945) prior to being discharged into the receiving stream. The Operational Agreement between the Permittee and the Environmental Management - Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. If any parts, requirements, or limitations contained in this permit are: unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a writtenpetition; conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Land Use and Environmental Services Agency (LUESA) Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0024945) Brian Upton, The Issacs Group Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume `of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities -as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. • 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may.. subject the Permittee .to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B :0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit .NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical' or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part I! of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 4th day of November, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION i -, for Alan W. Klimek, .E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit'Number WQ0029442 3 -Fast Track Engineering Certification Permit No. WQ0029442 April 19, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest,past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, E weekly, ❑ full time) the construction of the Stewart Creek • Crossing, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A'NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's. Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force'Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL. OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. r ppoOF NORTH CAROLINA OUNTY OF MECKLENBURG Permit No. `CO 14 4 2— DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (d1) and entered into this SIXTH day of SEPTEMBER 2005, by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and BEATTIES FORD RETAIL, LLC, a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in MECKLENBURG County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as STEWART CREEK CROSSING (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter -Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the BEATTIES FORD RETAIL, LLC (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans'and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. rnn r r. rim T nn Irv) heDEVELOPER shall provride in. the Declaration and Association Bylaws that the Disposal System and pir appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with, flaw and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities, The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal,. State, and local taxes and insurance. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, th.e Declaration and Association Bylaws shall provide that a fund be created out of the common expenses, Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. b_ In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no .limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. If a. wastewater collection system and wastewater treatment and!or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. Recognizing that. it would be contrary to the public interest and to the public health, safety and welfare for the. Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association. Bylawsthat the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and S above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North, Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MANAGEMENT COMMISSION Alan V. Klimek, P .,TDirector Division of Water Quality (Date) BEAT TIES FORD RETAIL, LLC Name of DEVELOPER (DateIllgc rrrin% . V'F .T11'1,n1 Permit Number WQ0029442 Central Files: APS SWP 04/19/06 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 11272 Facility Status Project Type In review New Project Version A Permit Classification Individual Permit Contact Affiliation Facility Name Stewart Creek Crossing Location Address Owner Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Beatties Ford Retail LLC Dates/Events Owner Type Non -Government Owner Affiliation Mike Weiss, Manager Orig Issue App Received Draft Initiated 10/12/05 Regulated Activities Commercial or industrial, other Restaurant Wastewater collection Scheduled Issuance Public Notice Issue Effective ReauestedlReceived Events Additional information requested Additional information received Additional information received Additional Information received Additional information requested Additional Information received Additional Information requested Additional information requested Additional information received Additional information requested Other agency comments requested Additional information received Expiration 11/02/05 11/02/05 11/14/05 12/01/05 01/05/06 01/19/06 03/24/06 04/10/06 NuV-a.-cuub iD:le From: FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 o: rtleibb.5b10ril1 e Application Number: USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! (to be completed by DW(]) 1. Owner:: la. BEATTIES FORD RETAIL, LLC Full Legal Name (company, municipality, HOA, utility, etc.) O 1 b, ,12/ Darren Wood A44-/414 (A F!Z H Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) Q Ic. The legal entity who will own this system is: re 0 Individual ❑ Federal ❑ Municipality ❑ State/County ❑ Private Partnership ® Corporation [J Other (specify): O ld. 521 E. Morehead St.. Suite 100 le. Charlotte Mailing Address City if. NC - lg. 28202 O State Zip Code lh. 704-365-0820 11. 704-365-8911 1j. dwood@provgrp.com Telephone Facsimile E-mail U 2. Project (Facility) Information: J 2a. STEWART CREEK CROSSING 2b. MECKLENBURG d Brief Project Name,(permit will refer tothis name) County Where Protect is Located EL Q 3. Contact Person: Q 3a. BRIAN T. UPTON, P.E. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (704) 527-3440 3c. bupton@isaacsgrp.com N FORMATION Phone Number • E-mail 1. Project is ® New 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (t.e. adding another phase, changing line size/length, etc.). Only include the modified Information In this permit application - do not duplicate project Information In B(7) and B(10-11) that has already been included In the original permit. 2. Owner is ❑ Public (skip to Item B(3)) ®.Private (go to Item 2(a)) 2a. if private, applicant will be: 2b. If sold, facilities owned by a (must choose one) ® Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) ❑ Public Utility (instruction Ili) ❑ Homeowner Assoc./Developer (Instnrction IV) 3. CHARLOTTE MECKLENBURG UTILITY DEPARTMENT Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. IRWIN CREEK WASTEWATER TREATMENT PLANT 4b. NC0024945 Name of WWTF WWTF Permit No. 5a. CMUD 5b. Gravity 15c. 100-03-566 Owner of Downstream Sewer Receiving Sewer Size Force Main L Permit Number of Downstream Sewer (if known) I_— 6. The origin of this wastewater is (check all that apply): 2 ❑ Residentlai Subdivision ❑ Car Wash W ❑ Apartments/Condominiums 0 Institution LU El Mobile Home Park 0 Hospltal ❑ School ❑ Church Ed ® Restaurant ❑ Nursing Home ® Office ❑ Other (specify): 100 % Domestic/Commercial Industrial % Other (specify): 7. Volume of wastewater to be allocated for this particular project: approx. 11,272 gallons per day *Do not include previously permitted allocations 8. if the permitted flow is zero, indicate why: ❑ interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 3 04/05 PAST -TRACK APPLICATION for GRAVITYSEWERS, ,PUMP STATIONS, AND FORCE MAINS PAGE 4 , . S. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). (20 EMPLOYEES x 25 GAUEMPLOYEE = 500 GPD) + (2500 SF RESTAURANT X 40 GAU15 SF = 6667 GPD) + (5 DRYCLEANER MACHINES X 500 GAUMACHINE = 2500 GPD) + (13381 SF RETAIL x 120 GAUI000 SF'=1606 GPD) =11272 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) ;.: ;.;.. (inches) Size Inches Length (feet) Gravity or Force Main (use the pull down menu) r 242 FORCE MAIN — -- — _ E 11111T111111 ENTER TOTAL LINE LENGTH IN MILE 0.0458 — - ..11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) �• 'r, -, Location ID I (self chosen - as shown on i Design Flow .lans for cross-reference) I (MGD) i Power Reliability Option Operational Point (1- dual fine feed; 2- permanent generator w/ATS; 3- GPM 0 TDH portable enerator wlteiemetry; 4-wet well storage) �'. _ PROP. LIFT STATION .011272 29.23 4 i 1 ' 'W .,. v 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ■ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION . 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? 0 ►_i • Yes Yes Yes ❑ ■ ■ No No No 0 ■ 0 N/A N/A NIA . 14. Does this project involve aerial lines or siphons? Check if yes! ❑ ihesalirtasvrill_t=e_considered_high.prioity_andrausi_ba.shecker_one _exeysixfnontbs___----._.—____ 15. Does this project have gravity sewer lines designed at minimum slopes? ■ Be aware that the Division will not accept Installed lines more than 10% flatter than the minimum slope. lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02103 - Rev. 3 04/05 NUV-U.3-iJU0 1: db from: lo:f1J4b103b040 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 V) 2E 0 F--- LL cc W V i0 lL _.. 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets a necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, E3 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody County Waterbody Stream Waterbody River Basin Index Classification Submit the 8.5" x 1I" COLOR topographic map as required in Instruction Vi regardless of whether a classification Is provided! 1. Applicant's Certification: la. 1, SIGNING OFFICIAL NAME, attest that this application for STEWART CREEK CROSSING has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if ell required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification In any application shall be guilty of a Class 2 misdemeanor which may include a tine not to exceed S10,000 as well as civil penalties up to $25,000 per violation. Signing Official Signature 2. Professional Engineer's Certification: Darren Wood War Date I attest that this application for STEWART CREEK CROSSING has been reviewed by me and is accurate, complete and consistent with the information In the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable reguialons, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, end the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification In accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which My fectucle a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. ,0. CA! r0 2a. BRIAN T. UPTON � .. pFESS Professional Engineer Name 2b. THE ISAACS GROUP Engineering Firm 2c. 8720 RED OAK BLVD., STE. 420 Mailing Address 2d. CHARLOTTE 2e. NC 2f. 28217 City 2g. (704) 527-3440 2h. State Zip (704) 527-8335 2i. bupton@isaacsgrp.com Telephone Facsimile E-mail <;.6 .!?• .... Q ti PI T. 0? N' `• Tilkk.'‘ q8 Seal, Signature & Date FTA 02/03 - Rev. 3 04/05 .TopoZone - The Web's Topographic Map Page 1 of 1 0.1 0.2 0.3 0.4 0.5 km 0 0.09 0.18 0.27 0.36 0.45 mi Map center is 35° 18' 14"N, 80° 51' 29"W (WGS84/NAD83) Derita quadrangle Projection is UTM Zone 17 NAD83 Datum http://www.topozone.coni/print. asp?z=17&n=3906745.0000926&e=512902.999999999&s—... 9/6/2005 TopoZone - The Web's Topographic Map Page 1 of 1 is 0.3 0.6 0.9 1.2 1.5 km 0.2 0.4 0.6 0.8 1 mi Map center is 35° 18' 14"N, 80° 51' 29"W (WGS84/NAD83) ©erica: quadrangle Projection is UTM Zone 17 NAD83 Datum G=0.082 http://www. topozone.corn/print. asp?z=17&n=390673 8.0000926&e=512901.999999999&s=... 9/6/2005 0/1012005 11:09 7043932319 ppr October 10, 2005 Mr, Michael A. O'Rourke The Isaacs Group 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 CMU NS C 0. 0TrE-MECKLENBURG IT1ES SUBJECT: WATER AND SANITARY S14fER FL C►1&tf ACCEPTANCE STEWARTS CROSSING C-MU PROJECT# WO-OS-567 Deer Mr. O'Rourke; PAGE 02/04 In response to your request, a flow acceptance study of the subject site has been completed and it has been determined that the discharge from this project does not transmit through areas of SSO concern by the NCDENR, Division of Water Quality. Please see attached map, Upon completion and acceptance of all necessary sewer lines, Charlotte -Mecklenburg Utilities agrees to accept the sewage flow of (see engineers carcurafion attached) from this project for transmission to the Irwin Creek Wastewater Treatment Plant; NPDES permit number NC0024945. for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whicrrever might have control. Upon completion and acceptance of all necessary water mair s t+ serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, (WMSP # 00-00251 & PWS ID # 0160010), on foie with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow, This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources., Chartotte-Mecklenburg Utilities does not expect any of the above conditions preclude water ewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. If you have any questions, you may contact me at (7t14j 9tu5107 Sincerely, CHARLOTTE-MECKLENBURG UTILITIES Philip S.Johnson Customer Service Division, New Services Section CHMLO 1 14-MECKLENBURG iJT1LIT1Es Customer Service division New Servl 4 Ph: 7 Fax 704f 11:09 704393231.9 CMU NS PAGE 04/04 r0/10i:2005 11:09 7043932319 CHU NS EP-BE-2005 IL:17 Fronn To:97W0932219 WASTEWATER FLOW RA1 t PROJECT: Stewart Creek Crossing - Beatties Ford Rd., Charlotte, NC ENR-ENVIRONMENTAL MANAGEMENT COMMISSION T15A: 021-! .0200 NORTH CAROLINA ADMINISTRATIVE COO E (Effective April, 2001) Page 37 39 PAGE 03104 4 '5 Type of Establishment qatIons Area (f) Seats EnlployeQs 0 h Units Dail Businesses gal/employee Food Service Facilities Restaurants Resataurent gal 115 ft2 of dining area Diycleaners gal / machine Stores, Shopping centers and malts gal / 1000 ft2 25 2500 500 120 13381 20 500 5657 2500 1606 Fk,wRete 11272 PUMPSTAl I veh� ,,�..�i�_�, pwr. 1R p: •, r'=S e:1%i11.::Y1{i Y: PROJECT: fSt `t ? DATE: 10-Apr-06 Force main highest elevation Number of units = Unit Flow (gpd) = Addition& flow Total Flow (gpd), (gpm) = Req'd Pump Capacity (gpd), (gpm) Actual Design Pumping Rate (gpm) Diameter of Wet Well (ft) = Volume WW per foot (cf/ft), (gift) = Storage Depth (ft) = Storage Volume (cf), (gal) = Fill Time for Storage Depth (min) = Run time for Storage Depth (min) = Total Cycle time (min) _ Pump Cycles/ hr = Head Loss due to Friction (in proposed pipe): Pump Elevation Force Main Equivalent Length (ft) = Force Main Diameter (in) _ Velocity in FM at pump rate (ftls) = Hazen-Williams'C'= Fricitonal head Toss / 100' at pump rate (ft) = Frictional head Toss at actual pumping rate (ft) _ Total Existing Head (ft) = Total Static Head (ft) = Total Fricitonal Head (ft) Total Dynamic Head = Wet Well/ Switch Elevations: Rim Elevation = Lowest Gravity Sewer Inlet Invert = High water alarm elev. = Lead pump on elev.= Pumps off elev. = Bottom wet well elev. = Depth of Wet Well = 11272.4 28181.0 6;'flOggil 28.26 211 ERMA 21.20 158 20.25 4.15 24.41 2.46 798.00 290.40 FF'1f :l6a10: 4.69 140.00 4.56 13.23 t lEtf ! 1 16.00 13.23 29.23 ladtd 800.25 799.75 799.00 798.00 11.00 Gar. None 7.8 =No. units*unit flow+additonal flow 19.6 = 2.5 * Total flow PEAK FLOW .4=1ft*3.14*D"2/4 .5 = Storage Depth * Volume/ft = Storage Volume/ Total avg. flow Storage Volume/ (Pump Rate - Total flow) = Fill time + Run time = 60/Total Cycle time =Force Main Length*1.2 gpm * 0.408/D"2 For type pipe Force Main Length/100 * Head Loss = FM Elev.-Pump Elev. = Force Main Length/100 *Head Loss = Exist. Head + Static Head + Frictional Head Invert elev. - 0.5' = High water alarm elev. - 0.5' = Lead elev. - Storage Depth = Pump Elev. = Pump elev. - 0.5' = Rim elev. - Bottom WW elev. H:\Excel12003103203-PUMPCALC.xls Page 1 Power Outage Storage Calculation: History of Reliability indicates a power outage period of: 4 hours & 45 minutes ( 285 minutes Finished Floor Elevation = Wet Well Rim Elevation Wet Well Bottom Elevation = 810.60 809.00 798.00 Total Flow, (gpm) = 7.8 Required Storage Volume (gal.) = Wet Well Diameter (ft.) = Wet Well Depth (ft.) Wet Well Volume per foot (g/ft) = Provided Storage Volume (gal.) = 2230.99 (Total Flow * Power Outage Period) 6.00 11.00 211.38 2325.23 O.K. per NCDENR requirements Page 1of1 North Carolina Elaine F Marshall DEPARTMENT OF THE. Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NC 27626-0822 (919)807-2000 Corporations Corporations Home 'Important Notice `Corporate Forms/Fees 'Corporations FAQ 'Tobacco Manufacturers 'Dissolution Reports •Non -Profit Reports `Verify Certification 'Online Annual Reports Links 'Secretary Of State Home •Register for E-Procurement 'Dept. of Revenue Legislation '1999 Senate Bills '2001 Bill Summaries 'Annual Reports 1997 'Corporations 1997 'Other Legislation Search 'By Corporate Name 'For New Corporation 'By Registered Agent Online Orders 'Start An Order New Payment Procedures Contact Us 'Corporations Division 'Secretary of State's web site Print *Printable Page For questions or comments abou Date: 11/1/2005 Click here to: View Document Filings Print apre-populated Annual Report Form 1 File an An Report 1 Corporation Names Name Name Type Legal mited Liability Company Information NC Beatties Ford Retail, LLC S©SID: FID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0752416 20-2012031 Current -Active 11 /16/2004 Domestic NC Perpetual Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Lewison, Duncan H. 8828 Heydon Hall Circle Charlotte NC 28210 8828 Heydon Hall Circle Charlotte NC 28210 8828 Heydon Hall Circle Charlotte NC 28210 8828 Heydon Hall Circle Charlotte NC 28210 he North Carolina Secretary of State's web site, please send e- mail to Webmaster. http://www.secretary.state.nc.us/Corporations/Corp.aspx?Piterld=6552412 11/1/2005 Re: [Fwd: Stewart Creek Subject: Re: [Fwd: Stewart Creek] From: Marie Doklovic <marie.doklovicCa),ncmail.net> Date: Thu, 06 Apr 2006 13:27:40 -0400 To Mike O'Rourke <morourkegisaacsgrp.com> CC: Dee Browder <Dee.Browder@)ncmail.net> Mike, Thanks, but we need the wet well to be sized to hold the longest outage of 4 hours and 45 minutes and therefore, no variance would be requested. We are not going to accept the variance request on the second longest outage per the summary provided to Dee. If you cannot resize the wet well, adjust floats, etc., then simply specify a portable generator receptacle and telemetry system. It is not that much more cost to the project. Thanks, Marie Mike O'Rourke wrote: Marie, Thank you for your response. Attached is a PDF file that includes the corrected Fast Track application (Section Bi2 and Section C have changed), supporting calculations, and topographic maps. The maps did not convert to a color PDF, so I have also attached a bitmap image of the area for further clarity. I can send a hard copy of this information to you or Dee upon your request. Please let me know ASAP if this application is acceptable. Thanks again. Sincerely, Michael ©'Rourke, El. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 morourke{cisaacsgrp.com From: Marie Doklovic[mailto:marie.doklovic@ncmail.net] Sent: Wednesday, April 05, 2006 3:41 PM To: Mike O'Rourke Cc: Dee Browder Subject: [Fwd: Stewart Creek] Mike, The attached is what 1 had sent to Dee regarding your request. She probably just hasn"t had time to ➢ of 3 4/6/2006 1:50 PM RE: [Fwd: Stewart Creek] Subject: RE: [Fwd: Stewart Creek] From: "Mike O'Rourke" <morourke@isaacsgrp.com> Date: Wed, 5 Apr 2006 18:35:50 -0400 To: "Marie Doklovic" <marie.doklovic@,ncmail.net> CC: "Dee Browder" <Dee.Browder@ncmail.net> Marie, Thank you for your response. Attached is a PDF file that includes the corrected Fast Track application (Section B.12 and Section C have changed), supporting calculations, and topographic maps, The maps did not convert to a color PDF, so I have also attached a bitmap image of the area for further clarity. can send a hard copy of this information to you or Dee upon your request. Please let me know ASAP if this application is acceptable. Thanks again. Sincerely, Michael ©'Rourke, E.I. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 morourke aaisaacsgrp.com From: Marie Doklovic[mailto:marie.doklovic@ncmail.net] Sent: Wednesday, April 05, 2006 3:41 PM To: Mike O'Rourke Cc: Dee Browder Subject: [Fwd: Stewart Creek] Mike, The attached is what I had sent to Dee regarding your request. She probably just hasn't had time to draft a request for you to correctfchange the application. Thanks, Marie ------- Original Message Subject:Stewartt Creek Date:Sun, 2 Apr 2006 13:55:09 -0400 (EDT) From:Marie.Doklovic@ncmail.net <Marie.Doklovic@ncmail.ret> Reply-To:Marie.DoklovicAncmail,net <Marie.Doklovic c_tfncmail.net> To:dee.browdeOner nail.net 1 of 3 416/2006 8:06 AM Authorization to sign for Beatties Ford Retail, LLC Subject: Authorization to sign for Beatties Ford Retail, C From: "Darren Wood" <dwood(c_4rovgrp.com> Date: Wed, 2 Nov 2005 08:51:34 -0500 To: <dee.browder@nemail.net> CC: <morourke@isaacsgrp.com>, <buptongisaaesgrp.com>, 'Mik Dear Dee, issprovgrp.com> I am a Manager and authorized signatory and company officer for Seethes Ford Retail, LLC (project also known as Stewart Creek Crossing) . Mike O'Rourke with the Isaacs Groups asked me to email confirmation of this in connection with our Iift station for the project. Please call me if you have any questions, Thank you for your assistance. Darren P. Wood, MRICS The Providence Group 521 E. Morehead Street Suite 100 Charlotte, NC 28202 Tel:(704) 365 0820x111 Fax:(704) 365 8911 1 of 1 11/3/2005 1;11 PM ory of Reliah ility, Beatties Ford Rd south of Sunset Rd. (Char... Subject: FW: History of Reliability, Beatties Ford Rd south of Sunset Rd. (Charlotte) From: "Mike O'Rourke" <morourkesaacsgrp.com> Date: Thu, 5 Jan 2006 09:22:30 -0500 To: <dee.browder@ncmail.net> Dee, I finally received the History of Reliability for the Beatties Ford Road site (Stewart Creek Crossing project). If the email from Duke Power is an acceptable form of correspondence (please see below), I will use that data to update the pump station calculations and then send them to you. Please advise. Thanks, Michael. O'Rourke, E.I. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 raorerax:ke@isaacsgrp..com -----original Message From: James M Wilson [mailto:imwilsTy nOdtake-energy.com] Sent: Wednesday, January 04, 2006 1:3t1 P'M To: Mike O'Rourke Subject: History of Reliability, Beatties Ford Rd south 6f Sunset Rd. (Charlotte) Michael, my records show four circuit outages ira tl'ae past three years that would have created outages for this loca The outages lasted 2 hours, 30 minutes, 4 hr. 45 minutes, and 10 minutes according to my data. In January of 2005 a raew circuit was added in the substation feeding this location. The station is located near the corner of Sunset Rd. on Statesville Rd. The old circuit route went south from the station to Hutchinson McDonald Rd, then along Cindy Lane to Beatties Ford Rd and back north, ending at Sunset Rd. The new circuit route feeds from the station west on Sunset Rd. then south by this location along Beatties Ford Rd. ending just past Cindy Lane. These changes were due to the obvious. load. growth in the area. as you can see the. result is less line exposure by about 2.5 miles.. Let me know if more information is needed for your analysis. Jim Wilson Distribution Engineering/ Duke Power 704-594-6362 1 of 1 1/5/2006 9:50 AM STEWART CREEK CROSSING Subject: STEWART CREEK CROSSING From: "Mike O'Rourke" <morourkegisaacsgrp.com> Date: Mon, 14 Nov 2005 15:47:08 -0500 To: <dee.browder ct ncmail.net> Dee, I have requested a power reliability letter from Duke Power (with regards to the Stewart Creek Crossing project). I expect to have the letter and relevant wet well storage calculations forwarded to you by Thursday 11/17/2005. Thanks, Michael O'Rourke, E.I. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, INC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 morourke( isaacsgrp.com I of ! t 1/17/2005 I:32 PM STEWART CREEK CROSSING Subject: STEWART CREEK CROSSING From: "Mike O'Rourke" <morourkesaacsgrp.com> Date: Thu, 1 Dec 2005 11:29:56 -0500 To: <dee.browder(✓ncrnail.net> Dee, I have contacted Duke Power (Power Quality Department) multiple times regarding the power reliability history for the proposed Stewart Creek Crossing development. They've assured me that they will research and mail the requested information. Please hold on to the Fast -Track application for the pump station. I sincerely appreciate your patience. Thanks, Michael O'Rourke, B.I. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 morourkeAisaacsgrp.com DEC 0 1 200 1of1 12/ 1 /2005 11:34 AM Beatties Ford Road Pump Station Subject: Beatties Ford Road. Pump Station From: "Mike O'Rourke" <morourke(cisaacsgrp.co,m> Date: Mon, 10 Apr 2006 15:29:30 -0400 To: "Dee Browder" <Dee.Browder@ncmail..net> CC: "Marie Doklovic" <marie.doklovic@ncn1ail.net> Dee, Attached is the revised Fast Track application page and supporting calculations. The developer prefers that we specify a larger wet well rather than a portable generator, so that's what the accompanying revisions reflect. Please let me know if you have any questions or requests. Thank you for your help, Sincerely, Michael O'Rourke, El. The Isaacs Group, PC 8720 Red Oak Boulevard Suite 420 Charlotte, NC 28217 phone: (704) 527-3440 ext: 134 fax: (704) 527-8335 morourke(ci),isaacsgrp.com Content -Description: BEATTIESFORD-REVISED-FTA.pdf BEATTiESFORD-REVISED-FTA.pdf Content -Type: application/octet-stream Content -Encoding: base64 I of 1 4/17/2006 9:57 AM PUMPS 'AT'I' PROJECT wort C tags o rdli , o' ddj� {t�� ��_.- .. _-. Y.s9.., iq S 64..u. �tvi�__ DATE: 10-Apr-06 Force main highest elevation = Number of units = Unit Flow (gpd) Additional flow Total Flow (gpd), (gpm) Req'd Pump Capacity (gpd), (gpm) _ Actual Design Pumping Rate (gpm) Diameter of Wet Well (ft) Volume WW per foot (cf/ft), (gift) Storage Depth (ft) = Storage Volume (cf), (gal) _ Fill Time for Storage Depth (min) = Run time for Storage Depth (min) Total Cycle time (min) _ Pump Cycles/ hr = Head Loss due to Friction (in proposed pipe): Pump Elevation = Force Main Equivalent Length (ft) _ Force Main Diameter (in) = , Velocity in FM at pump rate (ftls) = Hazen-Williams'C'= Fricitonal head loss / 100' at pump rate (ft) = Frictional head loss at actual pumping rate (ft) _ Total Existing Head (ft) = Total Static Head (ft) = Total Fricitonal Head (ft) = Total Dynamic Head = Wet Well/ Switch Elevations: Rim Elevation = Lowest Gravity Sewer inlet Invert = High water alarm elev. = Lead pump on elev.= Pumps off elev. _ Bottom wet well elev. = Depth of Wet Well 11272.4 28181.0 1001, ti 28.26 211.4 = 1ft*3.14"D^214 IPPTaiftI 21.20 158.5 = Storage Depth * Volume/ft 20.25 = Storage Volume/ Total avg. flow 4.15 = Storage Volume! (Pump Rate - Total flow) 24.41 = Fill time + Run time 2.46 = 60/Total Cycle time 798.00 290.40 y;!2-0o 4.69 140.00 4.56 13.23 16.00 13.23 29.23 PIy0 1 1 'BOY 800.25 799.75 799.00 798.00 11.00 None 7.8 =No. units*unit flow+additonal flow 19.6 = 2.5 'Total flow PEAK FLOW =Force Main Length*1.2 gpm * 0.408/D"2 For type pipe Force Main Length/100 * Head Loss xs„�6i&�?3ParadaltiRA�ui.1«.�� = FM Elev.-Pump Elev. = Force Main Length/100 ' Head Loss = Exist. Head + Static Head + Frictional Head = Invert elev. - 0.5' High water alarm elev. - 0.5' = Lead elev. - Storage Depth = Pump Elev. = Pump elev. - 0.5' = Rim elev. - Bottom WW elev. H:\Exce112003103203-PUMPCALC.xIs Page 1