HomeMy WebLinkAboutNC0026921_Inspection_20100222Ala&
NCDENR
North Carolina Department of Environment and Natural Resource
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins
Governor Director
February 22, 2010
Larry G Hagin
Town of Parkton
P.O. Box 55
Parkton, NC 28371
SUBJECT: February 19, 2010 Compliance Evaluation Inspection
Town of Parkton
Parkton WWTP
Permit No: NC0026921
Robeson County
Dee Freeman
Secretary
Dear Mr. Hagin:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on February 19,
2010. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, of the
Fayetteville Regional Office. The cooperation of Mr. Terry Wagers, facility ORC, was greatly appreciated. The facility
was found to be in Compliance with permit NC0026921. As a reminder, preservation of the Waters of the State can only
be achieved through consistent NPDES Permit compliance.
Comments
• Facility was clean and neat at the time of the inspection.
• The Discharge Monthly Reports for the months of September and December 2009 were compared to monthly
reports and appeared to be in order.
• The influent flow to the town's WWTP has increased above permitted limits due to the recent wet weather the
area has experienced. Mr. Wagers stated that some smoke testing was performed last year and some clean outs
were replaced. The Division of Water Quality recommends that the town contact North Carolina Rural Water for
additional smoke testing.
• Please repair the telescoping valve at return pumping station number 2.
• During the walk through portion of the inspection it was determined that the total residual chlorine (TRC) sample
was being taken at the wrong spot. Please take TRC sample at the bottom of the step aerator. When this sample
was taken at the correct location the chlorine result was over 500 micrograms. The permitted limit for TRC at this
facility is 17 micrograms. Please evaluate the current de -chlorination system and adjust it so the facility can meet
the NPDES permit requirement. Additional de -chlorination tubes may be needed during periods of high flow.
Failure to meet the TRC limit is a violation of the facility's NPDES permit and can result in Notices of Violation
and/or civil penalties. Again the division recommends contacting North Carolina Rural Water for technical
assistance in this manner.
Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301
Phone: 910-433-3300 \ FAX: 910-486-0707 \ Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
An Equal Opportunity \ Affirmative Action Employer
One
NorthCarol.ina
Mr. Hagin
Page 2
February 22, 2010
Please respond in writing to the above comments to the Fayetteville Regional Office of the Division of Water Quality by
March 19, 2010.
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any
questions, please call me at 910-433-3327.
cc: Terry Moore Wagers, ORC
Central Files
tFayetteville Files]
Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301
Phone: 910-433-3300 \ FAX: 910-486-0707 \ Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
An Equal Opportunity \ Affirmative Action Employer
Sincerely,
Mark Brantley )
Environmental Specialist
Surface Water Protection Section
Fayetteville Regional Office
One. ol.i.na
-Nat/Mi'"4`4
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 I NI 2 151 31 NC0026921 111 121 10/02/19 117
Type Inspector Fac Type
18I CI 191 sI 201 I
IIII1IIIIIII III66
Remarks
21IIIIIIII11.IIIIIII1IIIIIIIIIIIIII
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 169 7° 1 31 71 I NI 721 NIL_J 73 11 174 75I 11 1 I 1 I 180
. Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Parkton WWTP
Loop Rd
Parkton NC 28371
Entry Time/Date
10:30 AM 10/02/19
Permit Effective Date
10/01/01
Exit Time/Date
12:00 PM 10/02/19
Permit Expiration Date
14/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Terry Moore Wagers/ORC/910-224-8014/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Larry G Hagin,PO Box 55 Parkton NC 28371//910-858-3360/ No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance • Records/Reports
Self -Monitoring Program • Facility Site Review
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Mark
__ Brantley/ , /— FRO WQ//910-433-3300 Ext.727/
%'vt ��Z G%c+. -2 • ? J - / U
Signature of Management Q A Reviewer�ler�„ Agency/Office/Phone and Fax Numbers Date
e1
Belinda S Henson �W� /‘;`""" FRO WQ//910-433-3300 Ext.726/ - 1% 3 - l b
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
NPDES yr/mo/day Inspection Type
31 NC0026921 111 12I 10/02/19 117 181
C I
(cont.) 1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Comments
Facility was clean and neat at the time of the inspection.
The Discharge Monthly Reports for the months of September and December 2009 were compared to
monthly reports and appeared to be in order.
The influent flow to the town's WWTP has increased above permitted limits due to the recent wet weather
the area has experienced. Mr. Wagers stated that some smoke testing was performed last year and some
clean outs were replaced. The Division of Water Quality recommends that the town contact North Carolina
Rural Water for additional smoke testing.
Please repair the telescoping valve at return pumping station number 2.
During the walk through portion of the inspection it was determined that the total residual chlorine (TRC)
sample was being taken at the wrong spot. Please take TRC sample at the bottom of the step aerator.
When this sample was taken at the correct location the chlorine result was over 500 micrograms. The
permitted limit for TRC at this facility is 17 micrograms. Please evaluate the current de -chlorination system
and adjust it so the facility can meet the NPDES permit requirement. Additional de -chlorination tubes may
be needed during periods of high flow. Failure to meet the TRC limit is a violation of the facility's NPDES
permit and can result in Notices of Violation and/or civil penalties. Again the division recommends
contacting North Carolina Rural Water for technical assistance in this manner.
Please respond in writing to the above comments to the Fayetteville Regional Office of the Division of Water
Quality by March 19, 2010.
Page # 2
Permit: NC0026921 Owner - Facility: Parkton WWTP
Inspection Date: 02/19/2010 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ■ n n n
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n n n ■
Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n ■ n
Is the facility as described in the permit? ■ n n n
# Are there any special conditions for the permit? n ❑ ■
Is access to the plant site restricted to the general public? ■ n n n
Is the inspector granted access to all areas for inspection? ■ ❑ ❑ n
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? ■ n n n
Is all required information readily available, complete and current? ■ n n n
Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n
Are analytical results consistent with data reported on DMRs? ■ n n n
Is the chain -of -custody complete? ■ ❑ n n
Dates, times and location of sampling ■
Name of individual performing the sampling ■
Results of analysis and calibration ■
Dates of analysis ■
Name of person performing analyses ■
Transported COCs ■
AreDMRs complete: do they include all permit parameters? ■ n ❑ ❑
Has the facility submitted its annual compliance report to users and DWQ? ■
nnn
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? DOMO
Is the ORC visitation log available and current? ■ n n n
Is the ORC certified at grade equal to or higher than the facility classification? ■ n n n
Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ n
Is a copy of the current NPDES permit available on site? ■ n n n
Page # 3
Permit: NC0026921 Owner - Facility: Parkton WWTP
Inspection Date: 02/19/2010 Inspection Type: Compliance Evaluation
Record Keeping
Facility has copy of previous year's Annual Report on file for review?
Comment:
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: Flow meter was last calibrated on January 21, 2010 by Carolina Technical
Service.
Yes No NA NE
Yes No NA NE
■ nn❑
■ nnn
■ nnn
❑nn■
Bar Screens Yes No NA NE
Type of bar screen
a.Manual ■
b.Mechanical n
Are the bars adequately screening debris? ■ n n n
Is the screen free of excessive debris? ■ ❑ ❑ ❑
Is disposal of screening in compliance? ■ n n n
Is the unit in good condition? ■ n n n
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater? ■ n n n
Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ n n
Are weirs level? ■ ❑ n n
Is the site free of weir blockage? 0 n n n
Is the site free of evidence of short-circuiting? ■ n n n
Is scum removal adequate? ■ ❑ n n
Is the site free of excessive floating sludge? ■ ❑ ❑ ❑
Is the drive unit operational? ■ n n n
Is the return rate acceptable (low turbulence)? ■ n n n
Is the overflow clear of excessive solids/pin floc? ■ ❑ ❑ n
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) ■ ❑ n ❑
Page # 4
Permit: NC0026921 Owner - Facility: Parkton WWTP
Inspection Date: 02/19/2010 Inspection Type: Compliance Evaluation
Secondary Clarifier
Comment:
Oxidation Ditches
Are the aerators operational?
Are the aerators free of excessive solids build up?
# Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Are settleometer results acceptable (> 30 minutes)?
Is the DO level acceptable?(1.0 to 3.0 mg/I)
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes)
Comment:
Disinfection -Gas
Are cylinders secured adequately?
Are cylinders protected from direct sunlight?
Is there adequate reserve supply of disinfectant?
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000-
If yes, then when was the RMP last updated?
Comment:
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Yes No NA NE
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
n nn■
■ nnn
n nn■
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
n nn■
n nn■
Yes No NA NE
Tablet
n n■n
n n■n
n n■n
■ nnn
Page # 5
Permit: NC0026921 Owner - Facility: Parkton WWTP
Inspection Date: 02/19/2010 Inspection Type: Compliance Evaluation
De -chlorination
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment: The two de -chlorinators that are in service are not enough to meet the
NPDES permit limit of 17 micrograms (anything 50 micrograms and below are
acceptable)
Yes No NA NE
■❑❑❑
2
Standby Power Yes No NA NE
Is automatically activated standby power available? ■ ❑ ❑ ❑
Is the generator tested by interrupting primary power source? ■ ❑ ❑ ❑
Is the generator tested under load? ■ ❑ ❑ ❑
Was generator tested & operational during the inspection? ❑ ❑ ❑ •
Do the generator(s) have adequate capacity to operate the entire wastewater site? ■ ❑ ❑ ❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑ 1
Is the generator fuel level monitored? ■ ❑ ❑ ❑
Comment:
Pumps-RAS-WAS Yes No NA NE
Are pumps in place? ■ ❑ ❑ ❑
Are pumps operational? ■ ❑ ❑ ❑
Are there adequate spare parts and supplies on site? ❑ n ❑ •
Comment:
Influent Sampling Yes No NA NE
# Is composite sampling flow proportional? ❑ ❑ ■ ❑
Is sample collected above side streams? ■ ❑ ❑ ❑
Is proper volume collected? ■ ❑ ❑ ❑
Is the tubing clean? ■ ❑ ❑ ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ ❑ ❑ ❑
Is sampling performed according to the permit? ■ ❑ ❑ ❑
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ❑ ❑ ■ ❑
Is sample collected below all treatment units? ■ ❑ ❑ ❑
Is proper volume collected? ■ n n ❑
Page # 6
Permit: NC0026921 Owner - Facility: Parkton WWTP
Inspection Date: 02/19/2010 Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Is the tubing clean? ■ n n n
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n
Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n
Comment:
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ Linn
Comment:
Page # 7
Mayor
Larry G. Hagin
Finance Manager / Town Clerk
Angela Young
Chief of Police
Tammy Lowery
Public Works Director
Terry Wagers
TOWN OF PARKTON
Post Office Box 55 / 28 West David Parnell St
Parkton, North Carolina 28371
Office: 910-858-3360
Fax: 910858-9808
March 9, 2010
Mark Brantley
Division of Water Quality
225 Green Street
Suite 714
Fayetteville NC 28301-5043
SUBJECT: „-February 19, 2010 Compliance Evaluation Inspection'
Town of Parkton.
Parkton WWTP
'Permit No: NC0026921.
Robeson County.
Dear Mr.Brantley:
Alderman
Al McMillan
Alf Parnell
Robin Hill
Benton Finley
Fran Meinert
DENR- FA
MAR 1 1 2010
DWQ
.Upon completion -of The:Compliance Evaluation Inspection, February219, 2010, the
Town of'Parkton'has taken the' following corrective -actions as recommended.•
1. North Carolina.Rural•Water has,been contacted by the Town of Parkton to set,upa
. time for additional snioke testing for the collection; system;' E
2. The Town of Parkton will be repairing telescoping valve'atpurnp-station no 2`` as
.weather becOtries favorable:.
The.Town of Parkton has corrected sampling •pointfor•TRC,at the bottom.step -
'aerator: An' additional tube has been 'added for,de-chlorination; which; makes: a total
•
ofthree tubes. By adding the third tube, it has brought the towns limit'aback within
,permit limits of 17 micrograms
If you have any questions please contact Terry Wagers, Public'Works Director at (910)
858-3360 (office no.) or 910-2'24-8.014 (cell no)
Sincerely,
d&A//7 %c
Larry Hagin, Mayor
Town of Parkton