October 19, 2021
Mr. Chris Henderson, Public Utilities Manager
County of Lincoln
115 West Main Street
Lincolnton, NC 28092
Subject: Compliance Evaluation/ Bioassay Inspection
Lincoln County (Killian Creek) WWTP
NPDES Permit No. NC0088722
Lincoln County
Dear Mr. Henderson:
Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at
the subject facility on October 12, 2021, by Ori Tuvia. Tim Simmons' cooperation during the site
visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a
copy of the enclosed report.
At the time of the inspection, split samples for toxicity were taken. The results will be
provided at a later date.
The report should be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov.
Sincerely,
EDocuSigned by:
A14CC681AF27425...
W. Corey Basinger
Regional Supervisor
Mooresville Regional Office
Division of Water Resources
Cc: NPDES, MRO Files (Laserfiche)
State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704 663 1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction
1 IN I
21 1 1 1
Code NPDES yr/mo/day Inspection
2 L 3 I NC0088722 111 12I 21/10/12 I17
Type
18Oil I
I I 1 1 1
Inspector Fac Type
19I S I 201
1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I
1 11
1 1 1 1 1 i66
l
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 1 7914
I 711D I 72 I N I 731 I 74 751
I I 1
I I I I I I 180
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Killian Creek WWTP
7085 Old Plank Rd
Stanley NC 28164
Entry Time/Date
08:55AM 21/10/12
Permit Effective Date
20/03/01
Exit Time/Date
11:OOAM 21/10/12
Permit Expiration Date
25/02/28
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
James Timothy Simmons/ORC/704-748-2314/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
James T Simmons,7085 Old Plank Rd Stanley NC 281641/704-748-2314/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and
Ori A Tuvia
Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
Date
10/19/2021
f—DocuSigned by:
—__ DWR/MROWQ/704-663-1699/
6C
BB057A2DE017498...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
10/19/2021
�A14CC681AF27425...
Page# 1
sI
NPDES yr/mo/day
NC0088722 111 121 21/10/12
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Toxicity split samples were taken
Page# 2
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑
application?
Is the facility as described in the permit? • ❑ El El
# Are there any special conditions for the permit? • ❑ ❑ ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: The subject permit expires on 2/28/2025. The facility is in the process of upgrading the
equipment. The permit has addressed the upgrades by having a three stage effluent
limits based on the average daily flow. At the time of the inspection, the facillity was on
first stage.
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? • ❑ ❑ ❑
Is all required information readily available, complete and current? • ❑ ❑ ❑
Are all records maintained for 3 years (lab. reg. required 5 years)? El El ❑ •
Are analytical results consistent with data reported on DMRs? • El El El
Is the chain -of -custody complete? • El ❑ ❑
Dates, times and location of sampling •
Name of individual performing the sampling •
Results of analysis and calibration •
Dates of analysis ■
Name of person performing analyses ■
Transported COCs ■
Are DMRs complete: do they include all permit parameters? • El El El
Has the facility submitted its annual compliance report to users and DWQ? ❑ El ❑ •
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified El El • El
operator on each shift?
Is the ORC visitation log available and current? • El ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification? • El El El
Is the backup operator certified at one grade less or greater than the facility • ❑ ❑ ❑
classification?
Is a copy of the current NPDES permit available on site? • El El El
Facility has copy of previous year's Annual Report on file for review? El El El •
Page# 3
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Record Keeping Yes No NA NE
Comment: The records reviewed during the inspection were organized and well maintained.
DMRs, COCs, ORC visitation logs, calibration logs and bench sheets were reviewed for
the period April 2021 through July 2021.
At permit renewal on March 1, 2020, the percentage for toxicity sampling changed and
it was noted during the inspection the facility failed to make note of this change and
used the older percentage in the past six toxicity samples. The facility ORC has since
revised the EDMR to indicate the previous percentage was used.
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Influent and effluent analyses (including field) are performed under the on -site
laboratory certification #558. Meritech lab (total nitrogen, total phosphorus, toxicity
and zinc) has also been contracted to provide analytical support.
Influent Sampling
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is sampling performed according to the permit?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The subject permit requires influent biochemical oxygen demand (BOD) and total
suspended solids (TSS) composite samples.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 4
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Effluent Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑
representative)?
Comment: The subject permit requires both effluent composite samples (flow proportional) and
grab sampling
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, ME ❑ ❑
and sampling location)?
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MODE
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The facility appeared to be properly operated and well maintained. The operations
staff incorporate a comprehensive process control program with all measurements
being properly documented and maintained on-site.The facility is equipped with a
SCADA system to assist the wastewater staff in the operation of the treatment
processes/units including alarm notifications. The alarm system is also connected to a
telemetry system to notify the operations staff
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Yes No NA NE
•
•
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The facility is equipped with mechanical and manual bar screens. The manual bar
screen is only used during high volume and maintenance events
Grit Removal
Type of grit removal
a.Manual
b.Mechanical
Is the grit free of excessive organic matter?
Yes No NA NE
Page# 5
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Grit Removal
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Screenings and grit are disposed at the Cabarrus County Landfill by a contracted
company
Flow Measurement - Influent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: The flow meter was last calibrated on January 11, 2021 by Clearwater, Inc
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
Chemical Feed Yes No NA NE
Is containment adequate? • El ❑ ❑
Is storage adequate? ■ ❑ ❑ ❑
Are backup pumps available? • ❑ ❑ ❑
Is the site free of excessive leaking? • ❑ ❑ ❑
Comment:
Sequencing Batch Reactors
Type of operation:
Is the reactor effluent free of solids?
Does minimum fill time correspond to the peak hour flow rate of the facility?
Is aeration and mixing cycled on and off during fill?
The operator understands and can explain the process?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The facility is equipped with two SBRs operated in parallel. Sodium hydroxide is added
on an as -needed basis to maintain appropriate alkalinity/pH levels
Pumps-RAS-WAS
Are pumps in place?
Are pumps operational?
Are there adequate spare parts and supplies on site?
Comment:
Yes No NA NE
Page# 6
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: SBR effluent is decanted into a post equalization basin (0.457 MG) prior to tertiary
filtration.
Filtration (High Rate Tertiary) Yes No NA NE
Type of operation: Cross flow
Is the filter media present? • ❑ El El
Is the filter surface free of clogging? • El El El
Is the filter free of growth? • El El El
Is the air scour operational? El El • El
Is the scouring acceptable? • El El El
Is the clear well free of excessive solids and filter media? El El • El
Comment: Three disk tertiary filter units (12 disks per unit) were in service and operational.
Disinfection - UV Yes No NA NE
Are extra UV bulbs available on site? • El El El
Are UV bulbs clean? • El ❑ ❑
Is UV intensity adequate? • El El El
Is transmittance at or above designed level? • El ❑ ❑
Is there a backup system on site? • El El El
Is effluent clear and free of solids? • El ❑ ❑
Comment:
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
Yes No NA NE
▪ ❑ ❑ ❑
Page# 7
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Flow Measurement - Effluent Yes No NA NE
(If units are separated) Does the chart recorder match the flow meter? • ❑ ❑ ❑
Comment: The flow meter was last calibrated on January 11, 2021 by Clearwater, Inc
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: Some foam was observed at the discharge pipe at the time of the inspection, but it
dissipated within 20 feet.
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
▪ ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The facility is equipped with two aerobic digesters and an aerated sludge holding tank.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Dewatered bio-solids can either be land applied or transported to the Cabarrus County
Landfill for final disposal. The tertiary filter backwash, digester decant, and rotary press
filtrate are piped to the facility's recycle pump station. The pump station returns the
wastewater back to the influent prior to the SBR treatment process
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Yes No NA NE
• ❑ OE
Page# 8
Permit: NC0088722
Inspection Date: 10/12/2021
Owner - Facility: Killian Creek WWTP
Inspection Type: Bioassay Compliance
Standby Power
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up
power?
Is the generator fuel level monitored?
Comment: The standby generator is tested (automatically) under load once per week.
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 9