Loading...
HomeMy WebLinkAboutWQ0042824_Application (FTSE)_20210825State of North Carolina Department of Environmental Quality I)WR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvislon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: UO 4 . ( (to be completed by DWR) All items must be completed or the gonlication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Chatham Park Investors LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privatcly-Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Tim Smith per l 5A NCAC 02T .0106 b Title: Owner/Manager 4. Applicant's mailing address: 105 Weston Estates Way City: Caa State: NC Zip: 27513- 5. Applicant's contact information: Phone number: (919) 481-3000 Email Address: tim(u)a)prestondev.com 11. PROJECT INFORMATION: 1. Project name: Village South Pump Station & Utilities 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Preject If modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Chatham 4. Approximate Coordinates (Decimal Degrees): Latitude. 35.73499 Longitude.-79.14675: 5. Parcel ID (if applicable): 0069490, 0094479, 0007474 (or Parcel iD to closest downstream sewer) Z III. CONSULTANT INFORMATION: 1. Professional Engineer: Michael Penny License Number: 046994 C= ° Firm: McKim & Creed, Inc. G� m Mailing address: 170 Varsity Dr., Suite 500 �. City: Raleigh State: NC Zip: 27606-2689 O C er Phone number: (919) 233-8091 Email Address: mennyamckimcreed.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Chatham Park WRF Permit Number: W00039375 Owner Name: Chatham Park Investors LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0040741 Downstream (Receiving) Sewer Size: 16 inch System Wide Collection System Permit Number(s) (if amlicable): WQCS Owner Name(s): Town of Pittsboro FORM: FTA 04-16 Page I of 5 Vl. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ON. -'A 2. If the Applicant is a Developer of lots to be sold, has a Drvcloper's Operational Agreement iFORM: DEVbeen attached? [:]Yes ❑No ®NIA 3. If the Applicant is a l lutnc+'1'ro crt j Owners' Association has an Operational A r t t t : HOA) been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) `—GIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A WAC 02T 01 l4 l)? ®Yes ❑ No ➢ If Yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01 W fl) Daily Design Flow' b No. of Units Flow gall GPD gall GPD gall GPD gall GPD gall GPD gal/ GPD Total 0 GPD a See l5A NCAC 02T .01 14 I and ick2i for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .01 W) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ® Other (Explain): Project does not generate wastewater. Future projects will provide permits for new flow. FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1000 PVC ➢ Section II & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section Ill contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Village South Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.73269-- Longitude:-79.14304' 3. Design flow of the pump station: 144.25 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 360.6 gallons per minute at 119.4 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 2,500 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)t 11: ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station_ ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in I SA NCAC 02T ,0305(t) & 10 ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal -reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "*Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and intercel2tor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305 contains alternatives where separations in 02T.0305(0 cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC SILfface Water Classifications webpace ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes ❑ No ❑ N; A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I SA NCAC 02B .0200? ❑ Yes ❑ No ® N; A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 1 vA NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [:]No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I SA NCAC 02T.W.Z, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [—]Yes [—]No ® N.-A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with .15A NCAC=.02T, the 'r iW"qsi "rj _fs tKe P. Sr_m IlLn pf pum tations and Force Mains (latest version), and the Gravily Sewer Minimum Design Criteria fiatest version} as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: rL (4 AV G PchyN I attest that this application for (Professional Engineer's name from Application Item 11I.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): ignature Authority's name & title from Application Item 1.3.) 20 OFSSip ••.1�•,�` .Q S L~_ 046994 attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: <z Date. -� FORM- PTA (14-16 PROP 5 of s DESIGN NARRATIVE FOR FAST TRACK SANITARY SEWER PERMIT TOWN OF PITTS 3ORO TOWN OF PITTSBORO VILLAGE SOUTH PUMP STATION AND UTILITIES 635 East Street Pittsboro, North Carolina 27312 M&C Project 9 01561-0015 August 2021 Prepared by: 46 MCMM&CREED FNGINEEkS SURVEYORS MANNERS Michael Penny, PE McKim & Creed, Inc. 1730 Varsity Drive, Suite 500 Raleigh, NC 27606 P:919-233-8091 DESIGN NARRATIVE 1.0 PROJECT DESCRIPTION The Village South Pump Station and Utilities project installs approximately 2,500 LF of 6-inch PVC sanitary sewer force main; approximately 1,000 linear feet of 8-inch PVC gravity sanitary sewer; approximately 2,500LF of 6-inch and 4-inch PVC reclaimed water line; approximately 2,600 LF of 12-inch and 8-inch DIP potable water line. The proposed reclaimed water line, and potable water line connect to existing infrastructure and extend to proposed infrastructure designed by others. The proposed sanitary sewer force main begins at the proposed pump station and extends to an existing sanitary sewer gravity manhole. The proposed sanitary sewer outfall is a new gravity outfall installed for future development and extends to the proposed pump station. The project also includes construction of a sanitary sewer pump station, access drive and water service line. The project includes NCDOT roadway crossings of Chatham Parkway (SR-2700) and Suttles Rd (SR-1809). Each of these crossings will be conducted via bore and jack. Associated encroachments have been applied for and are awaiting approval. WithersRavenel, the site civil engineer for Chatham Park, has provided Section 401/404 permitting to respective agencies and is awaiting approval. The total project has approximately 4.6 acres of disturbed area. 2.0 EXISTING SYSTEM The proposed sanitary sewer forcemain will tie-in to an existing sanitary sewer gravity manhole. This downstream receiving sewer is permitted under WQ0040741 and is owned by the Town of Pittsboro. 3.0 PROPOSED ADDITIONS The proposed construction will add approximately 1,000 linear feet of 8-inch PVC gravity sanitary sewer. The proposed sanitary sewer is a new gravity outfall installed for future development and extends to the proposed pump station. Additionally, the proposed construction will add approximately 2,500 LF of 6-inch PVC sanitary sewer force main. The force main begins at the proposed pump station and extends to an existing sanitary sewer gravity manhole. The project does not include the permitting of new sanitary sewer flows. Other consultants will provide permits for the new flows in future projects for the Village South development. The proposed sanitary sewer pump station, identified as Village South Pump Station, is designed for a firm capacity of 144.25 MGD. The pump station construction will consist of one wetwell with two submersible pumps, one meter vault with bypass piping, odor control with bulk chemical storage, electrical and control panel rack, and a generator. The pump station is designed for permanent onsite backup generator; therefore, a power reliability plan has not been included with this submittal. The construction will also include an access drive and water service line with yard hydrant. The design flow of the pump station has been coordinated with WithersRaveneI, the site civil engineer for Chatham Park. v MCKIM&CREED v NC Dept of Environmental Qu, August 25, 2021 NCDEQ Water Quality Section 3800 Barrett Drive Raleigh, NC 27609 AUG Meigh Regional U'11-1c:c RE: Chatham Park Investors LLC Village South Pump Station and Utilities Fast Track Sewer System Extension Application To Whom It May Concern: ENGINEERS SVRVEY0R5 P L A N N E R S M&C 01561-0015 NC Dept of Environmental Quality AU6 �% C;4 Raleigh Rcgionat Office We respectfully submit this application for a Fast Track Sewer System Extension Application on behalf of the Chatham Park Investors LLC for the subject project. The Village South Pump Station and Utilities project installs approximately 2,500 LF of 6-inch PVC sanitary sewer force main; approximately 1,000 linear feet of 8-inch PVC gravity sanitary sewer; approximately 2,500LF of 6-inch and 4-inch PVC reclaimed water line; approximately 2,600 LF of 12-inch and 8-inch DIP potable water line. The project also includes construction of a sanitary sewer pump station, access drive and water service line. Included in this submittal are two copies (one original, one copy) of the following documentation: • Fast Track Application (Form: FTA 04-16), with attached documentation of business registry • USGS Quad Map (showing project area and approximate downstream connection point) Veril ar e IV Building . Aerial Map (showing project area and approximate locations of proposed 1 730 Varsily Drive gravity sewer, force main, and lift station) • Project Narrative Raleigh, NC 27606 • One (1) CD with PDF's of entire submittal package • Check No. 13906 in the amount of $480.00 9 1 9,233.8091 Please do not hesitate to contact me should you have any questions or concerns. We appreciate your time and consideration regarding this matter. Fox 919.233.8031 www, rack i me reed. co I.',01561 %0015'-. Water%40-fermit'.45-DEM, DEH, DOT, eu% W W Nermit,'- Fast Track Sewer'.01 2021.08.25 Corer Letter for Submittal.doc August 25, 2021 Page 2 Sincerely, McKIM & CREED, INC. Michael Penny, P.E. Project Engineer cc: Robin Rose, Chatham Park Investors (electronic) I I Mm cV E MUM u.i- DCPARTMCI+1' OC T,+C IW"MOR V.S. GEOIDOGr SIRIVCY a..+•.a�.r *UJ IOpO PIIT5MM WAORAWAC wrrxr muu [n..w.cawr. r-sawurr was 'S " 4 [Olr!![IMi {•Isyv I6 w, 11 n :ef�1tiy ai i f• RM + . M nHb h.lY MH1a M n U U 65 N {5 N� {r {{ •{[ �ssttu.lYb{ L.1.. w•F� 1w.,•I 11�11` iUiF I'N OOP � a..r.�.. PIIT"O, MC m+. LIMITED LIABILITY COMPANY ANNUAL REPORT ■ 114017 NAME OF LIMITED LIABILITY COMPANY: Chatham Park Investors LLC SECRETARY OF STATE ID NUMBER: 0754605 REPORT FOR THE CALENDAR YEAR: 2021 SECTION A: REGISTERED AGENT'S INFORMATION STATE OF FORMATION: NC E - Filed Annual Report 0754605 FChanges 1. NAME OF REGISTERED AGENT: Corporation Service Company 2. SIGNATURE OF THE NEW REGISTERED AGENT: SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT 3. REGISTERED AGENT OFFICE STREET ADDRESS & COUNTY 4. REGISTERED AGENT OFFICE MAILING ADDRESS 2626 Glenwood Ave Ste 550 2626 Glenwood Ave Ste 550 Raleigh, NC 27608 Wake County Raleigh, NC 27608 SECTION B: PRINCIPAL OFFICE INFORMATION 1. DESCRIPTION OF NATURE OF BUSINESS: Real Estate 2. PRINCIPAL OFFICE PHONE NUMBER: (919) 677-8000 3. PRINCIPAL OFFICE EMAIL: Privacy Redaction 4. PRINCIPAL OFFICE STREET ADDRESS 100 Matrix Drive 8000 5. PRINCIPAL OFFICE MAILING ADDRESS 100 Matrix Drive 8000 Cary, NC 27513 Cary, NC 27513 6. Select one of the following if applicable. (Optional see Instructions) ❑ The company is a veteran -owned small business ❑ The company is a service -disabled veteran -owned small business SECTION C: COMPANY OFFICIALS (Enter additional company officials in Section E. ) NAME: Donald R Parker TITLE: President ADDRESS: 100 Matrix Drive 8000 Cary, NC 27513 NAME: Timothy R. Smith NAME: Julian W. Rawl TITLE: Vice President TITLE: Vice President ADDRESS, 100 Matrix Drive 8000 Cary, NC 27513 ADDRESS: 100 Matrix Drive 8000 Cary, NC 27513 SECTION D: CERTIFICATION OF ANNUAL REPORT. Section D must be completed in its entirety by a person/business entity. David B. Keim SIGNATURE Form must be signed by a Company Official listed under Section C of This form 4/ 10/2021 DATE David B. Keim Secretary Print or Type Name of Company Official Print or Type Title of Company Official SUBMIT THIS ANNUAL REPORT WITH THE REQUIRED FILING FEE OF $200.00 MAIL TO- Secretary of State, Business Registration Division, Post Office Box 29525, Raleigh, NC 276264525 SECTION E: ADDITIONAL COMPANY OFFICIALS NAME: Donald R Parker NAME: David B. Keim NAME: TITLE: Treasurer TITLE: Secretary TITLE: ADDRESS: ADDRESS: ADDRESS: 100 Matrix Drive 8000 100 Matrix Drive 8000 Cary, NC 27513 Cary, NC 27513 NAME: NAME. NAME: TITLE: TITLE. TITLE: ADDRESS: ADDRESS: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: TITLE: ADDRESS: NAME: NAME: TITLE: TITLE: ADDRESS: ADDRESS: NAME: Name: TITLE: TITLE: ADDRESS. ADDRESS: NAME: NAME. TITLE: TITLE: ADDRESS: ADDRESS: