HomeMy WebLinkAboutNCG030714_2021 DMR_20211020NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG03 00714
Person Collecting Samples: Clinton Rayfield
Facility Name:CORMETECH, Inc.
Laboratory Name: Pace Analytical
Facility County: Cleveland
Laboratory Cert. No.: 329
Discharge during this period:
Yes
No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? EYes No
If so, which Tier (f, 11, or III)? Tier I
A copy of this DMR has been uploaded electronically via https:Hedocs.deg.nc.gov/Forms/SW-DMR Yes No
Date uploaded: 10/20/2021
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Parameter
Outfall 001
Outfali 002
Outfall 003
Ou#all 004
Out#ail 005
Code
N/A
Receiving Stream Class
Class C
Class C
Class C
Class C
Class C
N/A
Date Sample Collected MM/DD/rM
09/16/2021
09/16/2021
09/21/2021
08/31/2021
08/31/2021
46529
24-Hour Rainfall in inches
0.25
0.25
0.5
0.5
0.5
C0530
TSS in mg/L (100 or 50*)
38
20
8.6
7.2
3.4
00400
pH in standard units (6.0 — 9.0 FW,
7.52
6.85
7.19
6.67
7.54
6.8-8.5 SW)
01119
Copper, total recoverable in mg/L
0.0065
<0.005
0.0059
0.011
0.027
(0.010 FW, 0.0058 SW)
01051
Lead, total recoverable in mg/ L
0.0024
0.002
<0.001
<0.001
<0.001
(0,075 FW, 0.22 SW)
01094
zinc, total recoverable in mg/ L (0.126
0 012
<0.010
0.039
0.040
0.038
FW, 0.095 SW)
00340
Chemical Oxygen Demand (COD) in
<20
<20
32
45
38
mg/L (120)
00552
Non -Polar oil & Grease in mg/L (15)
<6.3
<5.9
<5.9
<5.7
<5.7
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there aresignificant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
of Permittee or Delegged Authorized Individual
I. plyler@cormetech.com
Email Address
lic
Date
980-722-1811
Phone Number
NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG0300714
Person Collecting Samples: Clinton Rayfiield
Facility Name: CORMETECH, Inc.
Laboratory Name: Pace Analytical
Facility County: Cleveland
Laboratory Cert. No.: 329
Discharge during this period: E]Yes
0
No (if no, skip to signature and dote}
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? E Yes ONO
If so, which Tier (I, ll, or IEI)? Tier I
A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR
Date Uploaded: 10/2012 021
Dyes No
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Parameter
Outfa11006
Outfall007
Outfall
Outfall
Outfall
Code
N/A
Receiving Stream Class
Class C
Class C
N/A
Date Sample Collected MM/DD/rM
08/31/2021
09/21/2021
46529
24-Hour Rainfall in inches
0.5
0.5
C0530
TSS in mg/L (100 or 50*)
7.6
6.6
00400
pH in standard units (6.0-9.0 FW,
6.49
8.37
6.8-8.5 SW)
01119
Copper, total recoverable in mg/L
0.019
<0_005
(0.010 FW, 0.0058 SW)
01051
Lead, total recoverable in mg/ L
<0 001
<0.001
(0.075 FW, 0.22 SW)
01094
Zinc, total recoverable in mg/ L (0.126
0.160
0.017
FW, 0.095 SW)
00340
Chemical Oxygen Demand (COD) in
39
<20
mg/L (120)
00552
Non -Polar Oil & Grease in mg/L(15)
<6.7
<5.0
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
of Permittee or Deldated Authorized Individual
l.plyler@cormetech.com
Email Address
Date
980-722-1811
Phone Number