Loading...
HomeMy WebLinkAboutNCG030085_2021 DMR_20211014DAIMLER Sean Quarry Sr. Environmental Engineer Daimler Trucks 1800 North Main Street Mouat Holly, NC 28120 704,822.7034 Phone October 13, 2021 NCDEQ - Division of Water Resources 610 East Center Avenue Suite 301 Mooresville, North Carolina 28115 To whom it may concern: Please find the enclosed September Stormwater Discharge Outfall (SDO) #001 and #002 forms for the Daimler Trucks NA, LLC - Mount Holly Truck Manufacturing Plant (TMP). The September 8th stormwater samples were collected at both locations during this monthly event. Analytical results from the sampling event show an exceedance of Copper and Zinc at SDO #001 and an exceedance of Zinc at SDO #002. The Facility also had an exceedance for the new permit COD benchmark at SDO #001. Daimler remains in Tier 3 at SDO #001 and SDO #002 for Zinc and at SDO #002 for Copper. The Facility enters Tier 1 for COD and exits Tier 3 at SDO #001 and SDO #002 for TSS and at SDO #001 for Copper. Shield will continue to perform monthly sampling per Tier level requirements until instructed to decrease sampling frequency by Daimler. Should you have any questions, please contact me at 704-822-7034 or sean-guat-ry@daimlei-.com. Sincerely, Daimler Trucks NA, LLC Sean Quarry Sr. Environmental Engineer Enclosures — Shield Engineering, Inc. Cover Leffer and DTNA signed DMR forms SHIELD October 5, 2021 Mr. Sean Quarry Daimler Trucks North America, LLC 1800 -North Main Street Mount Roily, NC 28120 Subject: Monthly Sampling — September 2021 NPDES General Permit No. NCG030000 Daimler Trucks of North America LLC - Mount Holly, North Carolina Shield Project No. 1140109-08 Dear Mr. Quarry: Shield Engineering, Inc. (Shield) successfully collected monthly stormwater samples for Stormwater Discharge Outfalis (SDO) #001 and #002 at the Mount Holly facility for the month of September 2021. During the September 81 sampling event, ShieId's field measurements of p1l were 7.00 and 7.04 at SDO #001 and SDO 4002, respectively. The analytical results of the stormwater samples collected during the qualifying storm event are attached to this cover letter. In addition, the Qualitative Monitoring Report (QMR) forms and the partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter. The Qualitative Monitoring Reports note the presence of a faint oil smell at SDO 4001 and SDO #002. In addition, both SDOs are overgrown with plants and clearing of the areas is recommended. Analytical results from the sampling event show an exceedance of Copper and Zinc at SDO 400I and an exceedance of Zinc at SDO #002. Daimler remains in Tier 3 at SDO 4001 and SDO #002 for Zinc and at SDO # 002 for Copper. The Facility enters Tier 1 for C.O.D. and exits Tier 3 at SDO #001 and SDO 4002 for TSS and at SDO 4001 for Copper. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks, North America. if you have any questions in reference to this document or require further information, please feel free to contact either of the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Y� Magdaline �Tza nri Senior Project Manager �tMelh J � . Grccnc, EIT 5inecr Attachment: Discharge Monitoring Report — September 2021 Robert L. Griffin, PE President/CEO 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Farm for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMRvia the 5torrnwater NI'DFS Permit Data Monitoring Report UMH1 Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR itei;ionol Office, Certificate of Coverage No. NCGO3 00B5 _ Facility Name: Daimler Trucks - Mount Holly - Person Collecting Samples: TJ Gladden Laboratory Name: Pace Analytical Facility County: Gaston Laboratory Cert. No.: 329 Discharge during this period: U Yes U No (if no, skip to signature and date] Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? f Yes No If so, which Tier (1, 11, or 111)? A copy of this ❑MR has been uploaded electronically via t�)s: etiocs.cirr -r1c. av Forrns 5W-DMR es No Date Uploaded: 1,)"yR/Z-( Analytical Monitoring Requirements for Outfalls with Industrial Activities -Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall002 Outfall outfall Outfall Code N/A Receiving Stream Class W5-IV; CA W5-IV; CA N/A Date Sample Collected MM/B0/YYYY 91a12021 9/8/2021 45529 24-Hour Rainfall in inches 0.1 0.1 C0530 TS5 In mg/L (100 or 500) 28 - f 33 pH in standard units (6.0 - 9.0 FW, 00400 6.8-9.5 SW) 7.00 7 04 Copper, total recoverable in mg/L — 01119 (0.010 FW, 0.0058 SW) 0.0081 0.0078 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) 0.0011 0.0011 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0,240 0.140 Chemical Oxygen Demand (COD) in - 00340 mg/L (1201 230 51 00552 1 Non -Polar Oil & Grease in mg/L (15) 71 C5.0 " Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW], Trout Waters (Tr) and Primary NurseryAreas (PNA) have a benchmark T55 limit of 50 mg/L. All other water classifications have a benchmark of 10D mg/L FW (FreshwaterI SW (Saltwater] Notes (optional): COD exceeded at 5DQ 001. Zinc exceeded at 5DO 001 and 5DD 002. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the Information submitted is, to the best of my knowl dge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false inforrt}atltp, includinkthe pqfAllity of fines and imprisonment for knowing violations." /V// /L / Signature !O rmittee or Delegated Au`fFsorized Individual Date Email Address Phone Number