Loading...
HomeMy WebLinkAboutNCG550142_Compliance Evaluation Inspection_20210920United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 IN I 2 LI 3 I NCG550142 111 121 21/09/20 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 21IIIIII IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I3 I 711 1 72 I N I 731 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 182 Regency Drive 182 Regency Dr Reidsville NC 27320 Entry Time/Date 03:30PM 21/09/20 Permit Effective Date 21/08/06 Exit Time/Date 03:55PM 21/09/20 Permit Expiration Date 25/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Marjorie B Tuttle,182 Regency Dr Reidsville NC 27320//336-342-2468/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Records/Reports Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Alex Lowe DWR/WSRO WQ/336-776-9689/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 sI NPDES yr/mo/day N CG550142 111 121 21/09/20 I17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On Monday, September 20, 2021, Alex Lowe of the WSRO conducted a routine Compliance Evaluation Inspection at 182 Regency Drive. Permittee Ms. Marjorie Tuttle was present for the inspection. Ms. Tuttle was unable to provide a copy of her permit or proof of the latest servicing of her wastewater system, but stated that the system had been pumped out in 2021 by Billingsley Septic Service of Reidsville. Mr. Lowe was able to confirm this by contacting Billingsley directly (invoice attached). Lowe offered that a copy of the permit be sent along to Ms. Tuttle with the inspections report for her records. Chlorination tablets were reported by Ms. Tuttle to be for pool care, and were being replaced monthly into two contact chamber tubes at the rear of the property. A tablet was observed in both tubes at the time of inspection. Lowe stated that the use of wastewater grade chlorination tablets was important, and asked Ms. Tuttle to replace the pool tablets with wastewater tablets. Ms. Tuttle stated that she has not had her effluent tested due to mobility issues, as her sampling outfall is in a hard to reach place. Mr. Lowe offered to provide a list of certified laboratories who may provide sample gathering services with the inspection report (see attached). This system appears to be in good order. To fulfill compliance expectations, Ms. Tuttle should begin annual sampling of effluent and retain copies of all paperwork related to permit renewals and system maintenance. Page# 2 Permit: NCG550142 Inspection Date: 09/20/2021 Owner - Facility: 182 Regency Drive Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ El ❑ application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ • ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ • ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Annual sampling and records retention should be implemented to fully meet compliance expectations. Yes No NA NE ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Page# 3