Loading...
HomeMy WebLinkAboutNCG550045_Compliance Evaluation Inspection_20210920United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN I 21IIIIII Code NPDES yr/mo/day Inspection 2 IL I 3 I NCG550045 111 121 21/09/20 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I3 I 711 1 72 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) 129 Forestdale Drive 129 Forestdale Dr Reidsville NC 27320 Entry Time/Date 04:OOPM 21/09/20 Permit Effective Date 20/11/20 Exit Time/Date 04:25PM 21/09/20 Permit Expiration Date 25/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Angela Yvonne Evans,129 Forestdale Dr Reidsville NC 27320//336-338-1092/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Records/Reports Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Alex Lowe DWR/WSRO WQ/336-776-9689/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date FDocuSigned by: L—o, T. SA,ac>_ 10/19/2021 145B49E225C94EA... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 3I NPDES yr/mo/day N CG550045 111 121 21/09/20 17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On Monday, September 20, 2021, Alex Lowe of the WSRO conducted a routine Compliance Evaluation Inspection at 129 Forestdale Drive. Permittee Ms. Angela Evans was present for the inspection. Ms. Evans was unable to provide a copy of her permit or proof of the latest servicing of her wastewater system. However, she was able to confirm that the entire tank had been removed and replaced within the last twelve months by Billingsley Septic Services. Mr. Lowe was able to confirm this by contacting Billingsley directly (invoice attached). Lowe offered that a copy of the permit be sent along to Ms. Evans with the inspections report for her records. Chlorination tablets were observed to be of the proper variety and were being replaced monthly into one of two contact chamber tubes. A tablet was observed in the tube closer to the house. Mr. Lowe suggested using both tubes concurrently to ensure disinfection of waste. Ms. Evans stated that she was unaware that the effluent would need to be tested by a third party to retain compliance. Mr. Lowe offered to provide a list of certified laboratories with the inspection report (see attached). This system appears to be in good order. To fulfill compliance expectations, Ms. Evans must only begin annual sampling of effluent and retain copies of all paperwork related to permit renewals and system maintenance. Page# 2 Permit: NCG550045 Inspection Date: 09/20/2021 Owner - Facility: 129 Forestdale Drive Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ ❑ application? Is the facility as described in the permit? ❑ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Yes No NA NE El El El El El El El El El El El El El 0 El El El El El El Page# 3