Loading...
HomeMy WebLinkAboutWQ0024827_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross 1r., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality February 1, 2005 Mr. James Culpepper, Executive Vice President Northlake Venture, LLC 121 West Trade Street, Suite 2550 - Charlotte, North Carolina 28202 Subject: Permit No. W00024827 Northlake Venture, LLC Northlake Commons Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Culpepper: In accordance with your application received on January 31, 2005, we are forwarding herewith Permit No. WQ0024827, dated February 1, 2005, to Northlake Venture, LLC for the construction and operation of the subject wastewater.collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. _ Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A.NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as ¢ . _ applicable ;;unless specifcaIly, mentionedi herein , Division, approval is .based,lon4acceptance certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2a.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10°%Post Consumer Paper l r�tCarolin, dVaturallrf Mr. James Culpepper Page 2 February 1 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Northiake Venture, LLC for the construction and operation of approximately 1,886 linear feet of 8-inch gravity sewer to serve 52,800 square feet of retail space and 26,400 square feet of restaurant space as part of the Northlake Commons project, and the discharge of 76,736 gallons per day of collected domestic wastewater into Charlotte Mecklenburg Utilities' existing sewerage system, pursuant to the application received January 31, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's- - Minimum Design Criteria for the. Fast -Track Pen-nitting of Pump Stations and Force Mains -,adopted, June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources ,and considered a part of this permit. _ • The sewage and wastewater collected by this system shall be treated in Charlotte Mecklenburg Utilities Irwin Creek WWTP (NPDES No. NC0024945) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Northlake Venture, LLC and Charlotte Mecklenburg Utilities for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. if you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. • Sincerely, for Alan W. Klimek, P_E. �' cc:;-__ _.Mecklenburg-County:,Healtfi.Department;=r'� : Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0024945) Kevin Vogel, Land Design, Inc. Water Quality Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to. the following specified conditions and limitations: 1. This permit shall .become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual • permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The *sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L•.0200 or the surface water standards in 15ANCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and .maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day .(i.e. 365 days per year). Pump stations that are connected to a telemetry system shall -be inspected at least once per week. High pnoritysewerlines shall be inspectedat least once pier every six month period of time - �y3observation-of ,.:a..I, ,?; iRC . A general observation of the'entire sewer�system shall. be..yco,nducted at Ieast.once per year. 3 Inspection and maintenance records shall be maintained for a period of at least three years. Overflows' and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. g. h_ 1 • 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H , .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permiftee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 1 Noncompliance Notification ' r,'ri" .y rr"r n.-a-7 z-.R.ram_ _ sZ I. - -, r ,... - . •.0, , f The Permittee _ shall - verbally report to a Division of Water Quality f employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 1 st day of February, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, J''E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024827 3 Fast Track Engineering Certification Permit No. WQ0024827 February 1, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial El Final I , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, ❑ weekly, ❑ full time) the construction of the Northlake Commons, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TOTHE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to.completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: la. Northlake Venture, LLC Application Number: �r-� (to be completed by DWQ) \t72 00 PAGE 3 Full Legal Name (company, municipality, HOA, utility, etc.) z lb James H. Culpepper, Executive Vice President © Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officialsl) Q 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal 0 Municipality ❑ State/County CZ ld. 121 W. Trade Street, Suite 2550 Street Address North Carolina ILL z Z 0 0 Private Partnership ❑ Corporation 0 Other (specify): State 1h, 704-972-2604 Telephone 2. Project (Facility) Information: 2a. Northlake Commons 1i. 704-972-2698 Facsimile Brief Project. Name (permit will refer to this name) 3. Contact Person: 3a. Kevin W. Voge Name and Affiliation of Someone Who Can Answer Questions About this Applic e. Charlotte City lg. 28202 2b. Zip Code james.culpep ert fa san.com„ E-mail ecklenburg ounty Where Project is Located 3b. 704-376-7777 Phone Number Project is ® New 0 Modification (of an existing permit kv©gel@landdesign.com E-mail If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ❑ Public (skip to Item B(3)) 2a. If private, applicant will be: 4a. a. Private (go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one) Retaining Ownership (i.e. store, church, single office, etc.) Leasing units (lots, townhomes, etc. - skip to item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Charlotte -Mecklenburg Utilities Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project Irwin Creek Name of WWTF 5b. 8 4b, NC00024945 5e. Receiving Sewer Size all that apply): ❑ Car Wash ❑ Institution ❑ Hospital Church • Nursing Home P Other (specify): Retail l3 7. Volume of wastewater to be permitted in this project: 76,ZWO gallons per day Charlotte -Mecklenburg Utilities Owner of Downstream Sewer The origin of this wastewater is (check Residential Subdivision ❑ Apartments/Condominiums Mobile Home Park 0 School Restaurant 0 Office WWTF Permit No. Permit Number of Downstream Sewer (if known 100 % Domestic/Coercial 8. If the permitted flow is zero, indicate why: ❑i Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Flow has already been allocated in Permit No, ❑ Rehabilitation or replacement of existing sewer with no new flow expected • Industrie • Other (specify): FTA 02/03 - Rev. 2 04/04 W Z 1-- Z 0 U 0_ 1-- Q ce 0 l:L z RACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" Gravity or Force Main (use the pull down menu) 1,886 If Gravity ENTER TOTAL LINE LENGTH IN MILES 0.36 mi -1 t 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliab- ility Option (self chosen - as shown on I Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) 1- WCL 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force m Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes D No ® N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No ❑ N/A PTA 02/03 - Rev. 2 04/04 0 V) Z 0 RACE APPLICATION for GRAVITY ERS, P MP ST°ATI+t NS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) ©R indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for anypump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of map for cross-reference) Waterbody la. County Waterbody Stream Waterbody River Basin Index Classification Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: (, James H. Culpepper, attest that this application for Northlake Commons has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a Hine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing Offic ri Signatur 2. Professional Engineer's Certification: Date 1 attest that this application for Northlake Commons has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exce d $10,,000 as well as civil penalties up to $25,000 per violation, 2a, Kevin W. Vogel Professional Engineer Name 2b, LandDesign, Inc. Engineering Firm 2c, 223 North Graham Street Address 2d. Charlotte 2e, NC 2f, 28202 City State Zip 2g. 704-376-7777 2h. 704-376-8235 2i. kvogel anddesi n.c Telephone Facsimile E-mail Seal, Signature tip Date FTA (72ft)' - Rev, 2 4 ,44,1 / 40,01 Nrwu, 0 4 441 7 pc) r ac roe, z 4,0 0 CHARIAYITR. C,HARLOTTE-MECKLENSURG UTILITIES. December 13, 2004 Mr. Kevin W. Vogel Land Design 223 North Graham Street Charlotte, NC 28202 SUBJECT, WATER AND SANITARY SEWER FLOW ACCEPTANCE NORTHLAKE COMMONS, PARCEL # 025-291-08 & 025-091-22 C-MU# 600-04-616 Dear Mr, Vogel, In response to your request, a flow acceptance study of the subject site has been completed and it has been determined that the discharge from this project does not transmit through areas of SSO concern by the NCDENR, Division of Water Quality. Please see attached map, Upon completion and acceptance of all necessary sewer linftis, Charlotte -Mecklenburg Utilities agrees to accept the sewage flow of 76,736 gallons per day (26,400 ft2 restaurant x 40 gpd/15 ft' dining area, and 52,800 'ft2 retail x 120 gpclil„000 ftz) from this project for transmission to the rwin Creek Wastewater Treatment Plant; NPDES permit number NC0024945, for treatrrent. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works: which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Upon completion and acceptance of all necessary water mains to serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, (WMSP # 00-00251 & PWS ID # 0180010), on file with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health„ and Natural Resources, Charlotte -Mecklenburg Utilities does not expect any of the above conditions preclude water ar sewer service to the subject site„ However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to Inc Charlotte -Mecklenburg Utilitiessystem is accepted on a first come, first served basis. If you have any questions, you may contact me at (704) 391-5107 Sincerely, RLOTTE-MECKLENBURG UTI TIES ; " '— Philip S. Join Customer Service Division, New Se,rvice Section CHARLUTTE-MECKLENBURG UTUT1ES Customer Service Division New Services Section www...crhutiltiesxoriar 5100 Brookshire Boulevard Dhaflotte: NO 28210 Ph: 704,9d-2221 Fax: 7041393-2219 CHARM CHARLOTTE-MECKLENBURG UTILITIES December -fa, 2004 Mr. Kevin W. Vogel Land Design 223 North Graham Street Charlotte, NC 28202 SUBJECT WATER AND SANITARY SEWER FLOW ACCEPTANCE NORTHLAKE COMMONS, PARCEL # 025-291-08 & 025-091-22 C-MU# 600-04-616 Dear Mr, Vogel: In response to your request, a flow acceptance study of the subject site has been completed and it has been determined that the discharge from this project does not transmit through areas of SSO concern by the NCDENR, Division of Water Quality, Please see attached map. Upon completion and acceptance of all necessary sewer lines, Charlotte -Mecklenburg Utilities agrees to accept the sewage flow of 76,736 gallons per day (26,400 ft2 restaurant x 40 gpdll 5 ft2 dining area, and 52,800 ftretail x 120 gpO11,000 ft2) from this project for transmission to the MnirCreek Wastewater' Treatment Plant; NPDES permit number NC0024945, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly .owned treatments works; which is contingent upon finai acceptance and issuance of a discharge permit from the appropriate ocat State, or Federal Agency,. 'whichever might have control. Upon completion and acceptance of ah necessary water mains to serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, (WMSP # 00-00251 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources. Charlotte -Mecklenburg Utilities does not expect any of the above conditions preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer ;system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities. system is accepted on a first come., first served basisi If you have any questions, you may contact me at (704) 391-5107 Sincerely, ,CHA,RLOTTE-M,ECKLENBURG UTILITIES PhiIip Si Johnson Customer Service Division, New Service Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section 5100 Brookshire Boulevard Charlotte, NC 26216 Ph: 704/399-2221 Fax: 704/3E33-2219 Map Name: Derita State: NC Year: 1993 USGS Order ID: TNC0181 USGS Identity 'ID: MPTNC018 Approx. Scale: 1" 1000' Central Files: APS SWP ✓ 01(31105 Permit Number WQ0024827 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 76736 Facility Fast Track Status Project Type In review New Project Version Penult Classification Individual Permit Contact Affiliation Facility Name Northlake Commons Location Address Owner Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Northlake Venture LLC Dates/Events Owner Type Non -Government Owner Affiliation James 121 W Trade St Charlotte Culpepper, Executive President Vice NC 28202 Scheduled °rig Issue App Received Draft Initiated Issuance 01/31/05 Regulated Activities Public Notice Issue Effective Expiration 2/I /0 5 Requested/Received Events Commercial or industrial, other Restaurant Wastewater collection Outfall NULL Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin Page 1 of 1 North Carolina Elaine F Marshall EPARTM ENT OF THE Secretary SECRETARY OF STATE PO Box 29822 Raleigh, NO 27626-0622 (919)807-2000 Corporations *Corporations Home Important Notice • Corporate Forms/Fees •Corporations FAQ •Tobacco Manufacturers •Dissolution Reports • Non -Profit Reports *Verify Certification * Online Annual Reports Links * Secretary Of State Home •Register for E-Procurement *Dept. of Revenue Legislation •1999 Senate Bills •2001 Bill Summaries •Annual Reports 1997 *Corporations 1997 • Other Legislation Search •By Corporate Name *For New Corporation •By Registered Agent Online Orders *Start An Order •New Payment Procedures Contact Us *Corporations Division *Secretary of State's web site Date: 1/31/2005 Click here to: View Document Filings 1 Print apre-populated Annual Report Form I File an Annual Report I Corporation Names Name Name Type NC Northiake Venture, LLC Legal Limited Liability Company Information SOSID: FID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0733029 Current -Active 7/2/2004 Domestic NC Perpetual Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Whitaker, Billie R 121 West Trade Street 27th Floor Charlotte NC 28202 121 West Trade Street 27th Floor Charlotte NC 28202 121 West Trade Street 27th Floor Charlotte NC 28202 121 West Trade Street 27th Floor Charlotte NC 28202 For questions or comments about the North Carolina Secretary of State's web site, please send e-mail to Webmaster. http://www.secretary.state.nc.us/Corporations/Corp.aspx?Pltemid=6490236 1/31/2005 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality January 20, 2005 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. James Culpepper, Executive Vice President Fed-Reames Road Limited Partnership 121 W. Trade Street, Suite 2550 Charlotte, North Carolina 28202 Subject: Dear Mr. Culpepper: Return of Permit Application Package Northlake Commons project Wastewater Collection System Extension Mecklenburg County, North Carolina The Division of Water Quality's Mooresville Regional Office is unable to accept the enclosed application package (and fee) for review for the following reason: ✓ Please provide the name of the corporation (Permittee) exactly as it is listed on the Articles of Incorporation with the NC Department of the Secretary of State. Upon searching the Corporations database through the Secretary of State's web site (http://www.secretary.state.nc.us/Corporations/), this office was unable to locate a registered corporation by the name of Fed-Reames Road Limited Partnership. Please provide a revised application listing the correct registered name. Please note that the item listed above must be completed prior to resubmitting the permit application package (with fee) for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate correction and resubmit the application. The review process will then begin upon receipt of the completed application. Please be advised that construction and/or operation of wastewater collection system extension without a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the violator to appropriate enforcement actions in accordance with North Carolina General Statute 143- 215.6. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute 143-215.1. No %hCarolina Naturally Mooresville Regional Office 610 East Center Avenue, Suite 30I Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycledll0% Post Consumer Paper . James Culpepper Page 2 January 20, 2005 If you should have any questions regarding the acceptance of your application, please do not hesitate to contact me at (704) 663-1699. Thank you for your cooperation. Sonja Basinger Consultant Enclosures (application + check no. 8972) cc: Kevin Vogel, Land Design, Inc., 223 North Graham St., Charlotte, NC 28202 (no enclosures) FT Application return file LandDegign urban design planning civil engireer ng landscape architecture TRANSMITTAL 223 North Graham Street, Charlotte, NC 28202 V: 704.333.0325 F: 704.332.3246 DATE: 1 /2812005 PROJECT NAME: Northlake Commons TO: NCDENR (Mooresville) NCDENR 919 N. Main Street CC: WE ARE SENDING: Mooresville NC 28115 VIA: NUMBER OF PAGES: 1 PROJECT #: 1004010 BUS. PHONE: (704) 663-1699 BUS. FAX: (704) 663-6040 BUS. MOBILE: PURPOSE: ❑ DRAWINGS 7 SPECIFICATIONS 1 X I APPLICATIONS ❑ FEES ❑ REDLINES ❑ DISKICD OTHER n MAIL I II XI I II FAX COURIER FEDEX GROUND FEDEX OVERNIGHT HAND DELIVERY ❑ PICK UP ❑ EMAIL I APPROVAL YOUR USE YOUR INFORMATION REVIEW 1 COMMENT YOUR REQUEST SIGNATURE QUANTITY: ITEM: DESCRIPTION: 1 Fast -Track Application for sewers submittal package in DEPT_ OF ENVII7,�, r 'AND NATt'-' ' , --•,,-,• OOREc:' �-' '' - NOTES: JAN 3 1 2005 FROM: Kris Rowe If this document was delivered via FAX, the accompanying transmission contains confidential Information intended only for the use of the individual of the entity named above. If you are not the intended recipient, you are hereby notified that any disclosure. copying, distribution or the taking of any action in reliance on the contents of this facsimile information is strictly prohibited. If you have received this FAX in error, please Immediately notify us by telephone to arrange for disposition or retum of the documents to us. Charlotte NC Washington DC Tampa FL Asheville NC Pinehurst NC Charlotte NC Nashville TN Beijing PRC