Loading...
HomeMy WebLinkAboutWQ0024602_Regional Office Historical File Pre 2018 (2)Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality November 19, 2004 Mr. Steve Craig, Manager Olympic Corporate Center II, LLC 801 E. Trade Street, Suite 200 Charlotte, North Carolina 28202 Subject: Permit No. WQ0024602 Olympic Corporate Center ll, LLC Olympic Corporate Center Building III Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Craig: In accordance with your application received on November 3, 2004, we are forwarding herewith Permit No. WQ0024602, dated November 19, 2004, to Olympic Corporate Center II, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's -responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: h2o,enr,state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper No `Carolina Wtura!!y Mr. Steve Craig . Page 2 November 19, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Olympic Corporate Center II, LLC for the construction and operation of approximately 80 linear feet of 6-inch gravity sewer, and approximately 1,686.09 linear feet of 8-inch gravity sewer to serve 154,000 square feet of office space as part of the Olympic Corporate Center Building !II project, and the discharge of 18,480 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities' existing sewerage system, pursuant to the application received November 3, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities McAlpine Creek WWTP (NPDES No. NC0024970) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Olympic Corporate Center 11, LLC and Charlotte Mecklenburg Utilities for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, 6 for Alan W. Klimek, P.E. cc: Mecklenburg County Health Department Mecklenburg Water Quality Program Mooresville Regional Office, Water Quality Section (WVVTF Permit No. NC0024970) Jeffery Orsborn, GNA Design Associates Water Quality Central Files Marie Doklovic, PERCS J NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be 'required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice Mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 19th day of November, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, ., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024602 3 Fast Track. Engineering Certification Permit No. WQ0024602 November 19, 2004 Complete and submit this form to the permit issuing regional office with the following: o One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a mariner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Olympic Corporate Center Building III, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE NIA PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Ouwnar; Olvattpi.c Corporate C Full Legal Name (company, munici Steve Craig, Manager Signing Official Name and Title (Please review The legal entity who will own this system is: D Individual 0 Federal 0 Municipality El State/County 0 Pri d, 801 E. Trade Street, Suite 200 Street Address North Carolina State 7©4 377 Telephone 2. Project (Farcttftl Olympic Corpora. Brief Project Name (perm Contact Person: eff Orsborn PE — P 5A NCAC 2H Application Number: (to be completed by DWQ) AhcZa724 or authoriz to Partnership [4 Corp a. Charlotte eno orttcia n 0 Othe s City lg. 28202 Zip Code 704.i37.7-4510 1j. Facsimile bon: Center, Building will refer to this name ect t%tanager E-mail 2b, Mecklenburg County Where Projeci Name and Affiliatuon of Someone Who Can Answer Questions About 704/373-1907 b. _ Phone Number E-mail c td his Application J orsb©rnagnadeaign. c©M. Project is New 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.), Only Include the modified information in this permit application - do not duplicate project information In B(7) and B(1t1-11) that has already been included in the original permit. 2. Owner is 0 Public (skip to Item B(3)) 3 Private (go to Item 2(a)) If private, applicant will be: 2b. If , facilities owned by a (must choose Q) 0 Retaining Ownership (Le. store, church, single office, etc.) 124 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) Char10 to leck1enb of Wastewater Treatment F pine (r ek lvtlTI Name of WWTF 5b. ng 0 Public Utility (Instruction III) 0 Homeowner Assoc,/Developer (Instruction IV') er From This Pro 0024970 WWTF Permit No. Owner of Downstream Sewer Receiving Sewer Size I Permit Number of Dow The origin of this wastewater is (check all that apply): 0 Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park 0 School 0 Restaurant Office Volume of 0 Car Wash 0 Institution 0 Hospital © Church 0 Nursing Horne 0 Other (specify): ewater Abe permitted in this project 184 Cgallons per day 1Ct} % Dome sit "Commercial % Industrial her (specify): If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 2 04/©4 ACK APPLICATION for GRAVITY SEWERS, PUMP ONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H ,0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 154,000 SF x 120 gpd 18,48 gp d ary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) ENTER TOTAL LINE LENGTH IN M ES Length (feet) .1686409 ary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID self chosen - as shown on Design Flow Operational Point (1- dua plans for cross-reference) ' (MGD) GPM Q TDH portab ty or Force Main use the pull down menu) G<rp,vity Gravity Power Reliabliity Option ne feed; 2- permanent generator wWATS 3- generator wltelernetry; 4-wet well storage) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable?, Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested, SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 3. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes El No El N/A Sedimentation and Erosion Control Plan? ® Yes 0 No 0 N/A Stormwater? Yes 0 No 0 N/A FTA 02/03 - 2 04/04 CK APPLICATION for GRAVITY S R PUMP STATIONS, AND FORCE MAINS PAGE 5 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map If chosen - as shown on Name of Waterbody Strea lap for cross-reference) Waterbody County River Basin Index Submit the 8.5" x 11" COLOR topographic map as required in InstructionVI regardless of whether a classification is providedl ............................. ........ Applicant's Certification: Waterbody Classification 1, SIGNING OFFICIAL NAME, attest that this application for PROJECT NAME has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing Official Signe Professional Engineer's Certification: O LI Date ! attest that this application for has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 es well as civil penalties up to $25,000 per violation, Jeffery C. 0rsborn Professional Engineer Name 2b. GNA Design Associates Engineering Firm 428 E. Fourth Str e Suite 408 Address Charlotte 2e. Nt 2f. 28202 City State Zip 704/373-1907'211704/358-0766 2i,jorsborn@ ;nadesign.com E-mail Telephone Facsimile Seal, Signatu FTA 02/03 - Rev. 2 04/04 11/19/04 Permit Number WQ0024602 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 18480 Facility Fast Track Permit Tracking Slip Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Olympic Corporate Center Building III Location Address Owner Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Olympic Corporate Center 11, LLC Dates/Events Owner Type Non -Government Owner Affiliation Steve Craig, Manager 801 E Trade St Charlotte NC 28202 Scheduled Orig.Issue App Received Draft Initiated Issuance 11/03/04 Regulated Activities Public Notice Issue Effective IJ(4/04— Requested/Received Events Commercial or industrial, other Wastewater collection Outfall NULL Expiration Additional Information requested Additional Information received Waterbody Name Stream Index Number Current Class Subbasin CHARLOTTE. CHARLOTTE-MECKLENBURG UTILITIES October 5, 2004 Mr. Jeff Orsborn GNA Design Associates, Inc. 428 East Fourth Street Suite 408 Charlotte, NC 28202 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE OLYMPIC CORPORATE CENTER C-MU# 600-04-592 Dear Mr. Orsborn: In response to your request, a flow acceptance study of the subject site has been completed and it has been determined that the discharge from this project does not transmit through areas of concern by the NCDENR, Division of Water Quality, Please see attached map, Upon completion and acceptance of all necessary sewer lines, Charlotte-Meckienburg Utilities (C-MU) agrees to accept the gravity sewage flow of 18,480 gallons per day (154,000 ft2 x 120 gpd11,000 ft2) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Upon completion and acceptance of all necessary water mains, C-MU agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, dated January 2000, (WSMP # 00- 00251 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, C-MU cannot guarantee a constant pressure or quality of flow, This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources. C-MU does not expect any of the above conditions to preclude water or sewer service to the subject site, However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MU system is accepted on a first come, first served basis, If you have any questions, please contact me at (704) 391-5129. Sincerely, Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITIES wow lnutiHtto Customer Service Division • New Services Section 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 &and Basin k Basin Old Dowd Road/Paw Creek Basin 111111Plott Road Area DLnsbury Court Area R445444. Typc E, SITE CMU# 604-44-592 "erra' rver Initttze Courtesy, of the. t. US Send To Printer htlp://tsrraserver.tr ie r soft, eurn/printimage.asp »1=2&S-12&X- 631&Y=4863&1 I7 Back Tr 'Ter a t,e r Change to I txt7 Print ze ShowCti Ctrs Charlotte, North Carolina, United Stotes 01 ul 1 6 I,SKrn or Chang to Port Tr rart 1 courtesy of the U S, C'e logical Survey 2004 Microsoft Corporation, Terms o Use Privacy Statement of 2 10/7/20(14 2,56 PM GNA DESIGN ASSOCIATES, INC. 428.East Fourth Street, Suite 408 Charlotte, North Carolina 28202 Alci:NE1.., .rc)Eir,ao„ t I/21Y ST03 I ...547 Al TENTION .rn t t 5 0114* I i E. Celtiltitt„..4.17, 5hci, 30 ' "*L C1,,, ,A4,00#it„...,, i.R,- 25115' 1 , .,.. Phone (704) 373-1907 WE ARE SENDING 'YOU Attached 7.1 Under separate, cover via the following terrish IT Shop drawings te: Prints :1 Plans F.. Samples Le Specifications .E. Copy of kttter Le Change ,order Mi MI* EC OP S DA If, NO DESC RIP1 R)N C4 esre-4 A Cizi THESE ARE; TRANSMITTED as checked below: ,‘ approval fl„! For your use As requested rrh For review and comment FOR BIDS DUE 71 PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO _ „ ;:17] Approved as submitted Approved ,as noted 1.] Returned for GOITeCtiOnS SIGNED: enclosures aro not as noted kindly notify el Resubmit copies for approval submit copies for distribution Return corrected prints Entity Names Page 1 of 1 • North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATF PO Box 29622 Raleigh, NC 276 26-0622 (919)807 2225 Corporations nCorporations Home *Important Notice *Corporate Forms/Fees *Corporations FAQ *Tobacco Manufacturers *Verify Certification *Online Annual Reports Links *Secretary Of State Home *Business License *Register for E-Procurement *Dept. of Revenue Legislation *1999 Senate Bills 02001 Bill Summaries *Annual Reports 1997 *Corporations 1997 *Other Legislation Search *By Corporate Name *For New Corporation *By Registered Agent Online Orders *Start An Order *New Payment Procedures Date: 11/19/2004 Click here to: View Document Filings I MPrint a pre -populated Annual Report Form I File an Annual Report I Corporation Names Name Name Type NC Olympic Corporate Legal Center II, LLC Limited Liability Company Information SOSID: 0540868 Status: Current -Active Date Formed: 3/10/2000 Citizenship: Domestic State of Inc.: NC Duration: Perpetual Registered Agent Agent Name: Craig, Steve R. Registered Office Address: 801 E. Trade Street Charlotte NC 28202 Registered Mailing 801 E Trade St Address: Charlotte NC 28202 Principal Office Address: 801 E Trade St Charlotte NC 28202 Principal Mailing Address: No Address For questions or comments about the North Carolina Secretary of States web site, please send e-mail to Webmaster. For questions or comments concerning the Corporations Division, please send e-mail to Corporations Administrator Click here for help downloading forms. http://www.secretary.state.nc.us/corporations/soskb/Corp.asp?5260661 11/19/2004 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality October 28, 2004 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. Steve Craig, Manager OCC II, LLC 801 E. Trade Street, Suite 200 Charlotte, North Carolina 28202 Subject: Return of Permit Application Package Olympic Corporate Center, Building III project Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Craig: The Division of Water Quality's Mooresville Regional Office is unable to accept the enclosed application package (with fee) for review for the following reasons: ✓ Please provide the name of the corporation (Permittee) exactly as it is listed on the Articles of Incorporation with the NC Department of the Secretary of State. Upon searching the Corporations Database through the secretary of State's web site (http://www.secretarv.state.nc.us/Corporations), this office was unable to locate a registered corporation by the name of OCC II, LLC. Please revise the application accordingly to reflect a registered corporation. ✓ Item B (6), Wastewater Origin has not been completed as is required by Section I. of the application instructions. ✓ The site location was not labeled on the submitted topo map as is required by Instruction VI of the Application Instructions. Please note that the items listed above must be included and/or completed prior to resubmitting the permit application package (with fee) for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate corrections and resubmit the application. The review process will then begin upon receipt of the completed and corrected application. Please be advised that construction and/or operation of wastewater collection system extension without a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the Noi Carolina �tura!!y Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Steve Craig Page 2 October 28, 2004 violator to appropriate enforcement actions in accordance with North Carolina General Statute 143- 215.6. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute 143-215.1. If you should have any questions regarding the acceptance of your application, please do not hesitate to contact me at (704) 663-1699. Thank you for your cooperation. Sincerely, Sonja Basinger Consultant Enclosures (application + Check No. 2057) cc: Jeffrey Orsborn, GNA Design Associates (no enclosures) FT Application Return File Fast Track Enjirteer ng C rtt (cation Permit No.WQ0024602 November 19, 2004 na Complete and Submit this form to the permit issuing regional gional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit_. modi fications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial 0 Final C c0.R ^-11 , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( ,periodically, El weekly, L full time) the construction of the Olympic Corporate Center Building Ill, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the Observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, LETTER OF TRANSMITTAL STEWART TO NCDENR FROM im Donahoe 610 East Center Ave., Suite 301 Senior Civil Designer Mooresville, NC 28115 704.334.7925 x(314) 704-663-1699 Attn: Dee Browder DATE 05/02/07 PROJECT NUMBER X6084 SENT VIA US Postal Service PROJECT NAME Olympic Corporate Center COPIES DATE', DESCRIPTION Fast Track Certification Record Drawn • For approval For your use As requested • • 1 For review & comment Approved as submitted Approved as noted COMMENTS GNED s Donahoe ENGINEERING. INNOVATION. SOLUTIONS." Returned for corrections Returned after review esubmit copies for approval r MAY COPPED TO File 200S CC .L5G€ST C. Sti=TE 714