Loading...
HomeMy WebLinkAboutWQ0023636_Regional Office Historical File Pre 2018 (2)OF WArF9 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality March 5, 2004 Mr. W. Clay Grubb, President Morrison Place, LLC 1530 Elizabeth Ave., Suite 200 Charlotte, North Carolina 28204 Subject: Permit No. WQ0023636 Morrison Place, LLC Morrison Place Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Grubb: In accordance with your application received on February 24, 2004, we are forwarding herewith Permit No. WQ0023636, dated March 5, 2004, to Morrison Place, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's. responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional office 919 N. Main Street, Mooresville, NC 28115 Internet httpJlh2o.enr.state.nc.usl Telephone (704) 663-1699 Fax (704) 663-6040 NEOENR DENR Customer Service Center Telephone 1 877 623-6748 Mr. W. Clay Grubb Page 2 March 5, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Morrison Place, LLC for the construction and operation of approximately 986.5 linear feet of 8-inch gravity sewer to serve 122 units and 53,644 square feet of commercial space as part of the Morrison Place project, and the discharge of 29,617 gallons per day of collected domestic wastewater into Charlotte Mecklenburg Utilities' Sugar Creek WWTP (NPDES No. NC0024937) existing sewerage system, pursuant to the application received February 24, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between Morrison Place, LLC and Charlotte Mecklenburg Utilities for collection and final treatment of wastewater is in full force and effect. if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Mecklenburg County Health Department Mecklenburg County Water Quality Program Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0024937) Jeffrey Smith, Bulla Smith Design Engineering Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become. voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. • e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. I 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentationfr the parties involved, shallbe other supporting materials as may be appropriate. The approvalof this request considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. if this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Centet, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. • 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 5`11 day of March, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION A).-* �. for Alan W. Klimek, P,, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023636 3 Fast Track Engineering Certification Permit No. WQ0023636 March 5, 2004 Complete and submit this form to the permit issuing regional office with the following: o One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the.project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Morrison Place, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) V J0400 2 36 363 A. APPLICATION INFORMATION' 1. Owner. la. Morrison Place LLC Full Legal Name (company, municipality, HOA, utility, etc.) Ib. W. Clay Grubb, President Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: ❑ Individual ■ Federal ■ Municipality ■ State/County ❑ Private Partnership 0 Corporation ■ Other (specify): ld. 1530 Elizabeth Ave, Suite 200 1 e. Charlotte Street Address City If. NC lg. 28204 State Zip Code lh. 704-372 -5616 1 i. 704-372-9882 1j. klawler@grubbproperties.com Telephone Facsimile E-mail 2. Project (Facility) Information: 2a, Morrison Place Mecklenburg Brief Project Name (permit will refer to this name) rb. County Where Project is Located 3. Contact Person: 3a. Ken Lawler Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-72-5616 _ _ 3c. klawler@grubbproperties.com Phone Number E-mail 1. Project is 0 New ■ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the phase, changing line size/length, etc.). Only include the modified duplicate project information in B(7) and B(10-11) that has already reason for the modification (Le. adding another information In this permit application - do not been included in the original permit. 2. Owner is ❑ Public (skip to Item B(3)) 0 Private (go to Item 2(a)) Z 0 1- a. If private, applicant will be: • Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) • Selling units (lots, townhomes, etc. - go to item B(2b)) 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction ill) 0 Homeowner Assoc./Developer (Instruction IV) 3. Charlotte Mecklenburg Utilities E Owner of Wastewater Treatment Facility (VVVVTF) Treating Wastewater From This Project re 4a. Sugar Creek WWTP 14b. NC 0024937 LL Name of WWTF I WWTF Permit No. Z 5a. Charlotte Mecklenburg Utilities 5b. 8" �5c. Unknown I Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) ,' . The origin of this wastewater is (check all that apply): Ce ILI tl m • Residential Subdivision ►l Apartments/Condominiums ■ Mobile Home Park ❑ School • Car Wash ■ Institution ■ Hospital • Church 100 % Domestic/Commercial % Industrial 0 Restaurant ■ Nursing Home % Other (specify): 0Ofce ❑ Other (specify): 7. Volume of wastewater to be permitted in this project: 29,617 gallons per day 8. If the permitted flow is zero, indicate why: • Interceptor Line - Flow will be permitted is subsequent permits that connect to this line • Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 . Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). 122 units x 190 gpolunit plus 53,644 ft2 Commercial/Retail X 120 gpd/ft2 = 29,617 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8" 986.5 qLt ha - _ _ -a 75- _.__.____..__..,..,_,.._._.,._._._._.,.._.__.__.,..,..__.,..,.___..___,..__.._.,.._.,..__.._._._...._......_._.,..,..,._...._......_._...._._._.,__._.__.__...._.._.__ t ....................................... CI _.,.._._.,.__.__......._. ._..__._. LLI — Z H Z 0 0 a11. ENTER TOTAL LINE LENGTH IN MILES Summary of Pump Stations to be Permitted 0.22 (attach additional sheets as necessary) 2 CC 0 i Location ID (self chosen - as shown on E plans for cross-reference) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator wltelemetry; 4-wet well storage) LI— Z I— NE ILI a' m 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force € Mains (latest version). the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? I ►i Yes • No If no. please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: (SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? I Wetland/Stream Crossings - General Permit or401 Certification? ■ Yes ❑ No ►AI N/A Sedimentation and Erosion Control Plan? Approved ►i Yes ■ No ■ N/A Stormwater? Approved ® Yes ■ No • N/A ETA 02/03 - Rev. 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Z: 0 ll c/) a —J W H co { 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map j {self chosen - as shown on map for cross-reference) Name of Waterbody County River Basin Waterbody Stream ; Waterbody Index i Classification 3 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 11. Applicant's Certification: 1 1, W. Clay Grubb, attest that this application for Morrison Place Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. // //"/ Signing 0 ial Signature Date 2. Professional Engineer's Certification: I attest that this application for Morrison Place Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jeffrey 1. Smith Professional Engineer Name 32b. Bulla Smith Design Engineering Engineering Firm 2c. 1347 Harding Place, Suite 201 Address 2d. Charlotte 2g. City 704-333-3122 Telephone e. NC i2f. 28204 State Zip 2h. 704-333-8252 2i. jsmith@bullasmith.com Facsimile E-mail 136ao98^opea q4. • o i !• Q]1A L U ▪ Q• a 6 O �PO• �FQay��t�i ova /C`O• ;ego*oaoo�\ ®a r `• S!orGFeG49fy ��9:3 Seal, Signature & Date FTA 02/03 - Rev. 1 06/03 Entity Names http://www.secretary. state.nc.us/corporations/soskbJCorp.asp?56996 NC North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NC 27626-0622 (919)807-2000 Corporations Home Important Notice Corporate FormslFees Corporations FAQ Tobacco Manufacturers ,.Verify Certification AOnline Annual Reports Secretary Of State Home. Business License gRecister for E-Procurement Dept of Revenue 5.1999 Senate Bills L200:1 Bill Summaries Annual Reports 1997 Corporations 1997 Other Legislation 4.By Corporate Name °For New Corporation !By Registered Agent Start An Order °New Payment Procedures Date: 3/3/2004 Click here to: View Document Filings °°° Print a pre -populated Annual Report Form I File an Annual Report 1 Corporation Names Name Name Type Morrison Place, LLC Legal Limited Liability Company Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0692892 Current -Active 9/30/2003 Domestic NC Perpetual Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Grubb, W Clay 1530 Elizabeth Ave, Second Floor Charlotte NC 28204 1530 Elizabeth Ave, Second Floor Charlotte NC 28204 1530 Elizabeth Ave, Second Floor Charlotte NC 28204 1530 Elizabeth Ave, Second Floor Charlotte NC 28204 For questions or comments about the North Carolina Secret For questions or comments concerning the Corporations Dr Click here for help cI 1 of 1 3/3/2004 3:28 PM 03/03/04 Permit Number WQ0023636 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer sonja.williams Permitted Flow 29617 Facility Permit Contact Affiliation Facility Name Morrison Place Location Address Owner Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Morrison Place, LLC Dates/Events Owner Type Non -Government Owner Affiliation W. Grubb 1530 Elizabeth Avenue Charlotte NC 28204 Scheduled Orig Issue App Received Draft Initiated Issuance 02/24/04 Regulated Activities Apartment complex Restaurant Wastewater collection Outfall NULL Public Notice Issue Effective 3/s/o4 Requested/Received Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin January 28, 2004 Mr. Jeff Smith Bulls Smith Design Engineering, P.A. 1347 Harding Place Suite 201 Charlotte, NC 28204 SUBJECT: Dear Mr. Smith: CD) CHARLOTTE-MECKLENBURG UTILITIES WATER AND SANITARY SEWER FLOW ACCEPTANCE MORRISON PLACE TAX PARCEL# 177-092-03, -04, -05, -06 In response to your request, a flow acceptance study of the subject site has been completedand it has been determined that the discharge from this project does not transmit through areas of SSO concern by the NCDENR, Division of Water Quality. Please see attached map. Upon completion and acceptance of all necessary sewer lines to serve the subject site, Charlotte - Mecklenburg Utilities agrees to accept the gravity sewage flow of 29,617 gallons per day (122 units x 190gpd/unit plus 53,644 ft2 Commerical/Retail x 120 gpd/1,000 ft2) from this project for transmission to the Sugar Creek Wastewater Treatment Plant; NPDES permit number NC0024937, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Upon completion and acceptance of all necessary water mains to serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, dated January 2000, (WMSP # 00-00251 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, C-MU cannot guarantee a constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources. Charlotte -Mecklenburg Utilities does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MU system is accepted on a first come, first served basis. If you have any questions, you may contact me at (704) 391-5129. Sincerely, CHARLOTTE-MECKLENBURG UTILITIES aiat6a, Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITIES Engineering Division • New Services Section www.cmutilities.com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 ' Fax: 704/393-2219 February NC Department of Environment and Naturallsoures Division of Water Quality 919 N. Main Street Mooresville,. 1 Morrison Place Charlotte, NC Subject: Fast Track Serer Permit py I Item BULLA SMITH Fast Track Application _.. 1/ x 1 USGS Map Processing Fee Charlotte beck. Utiliti s Floc Acceptance Letter