Loading...
HomeMy WebLinkAboutWQ0042772_Application (FTSE)_20211001Permit Number WQ0042772 Program Category Non -discharge Permit Type Gravity Sewer Extension.. Pump Stations. & Pressure Sewer Extensions Primary Reviewer tyler.benson Coastal SWRuIe Permitted Flow Facil Facility Name Flats at Hanover Center Private Sewer Location Address Owner Owner Name New Market Hanover LP Central Files: APS _ SWP 8/26/2021 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County New Hanover Facility Contact Affiliation Owner Type Non -Government Owner Affiliation Jeffrey Sprain 3284 Northside Pkwy NW Dates/Events Atlanta GA 30327 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/19/2021 NOWUS & TUNSTALL CONSULTING ENGINEERS P.C. 2602 Tron Gate Drive, Suite 102 Wilmington, NC 28412 (910) 343-9653 (910) 343-9604 Fax John S. Tunstall, P.E. T. Jason Clark, P.E. Robbie P. Hennelly, E.I. August 13, 2021 NC DEQ Division of Water Resources Water Quality Regional Operations Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Gravity Sewer Extension Fast -Track Permit Application (Public) Flats at Hanover Center 3500 Park Avenue j=(CE6VE New Hanover County N&T Project No. 20018 , AUG y 2011 Dear Sir or Madam: gy.______,__ 1429 Ash -Little River Road Ash, NC 28420 (910) 287-5900 (910) 287-5902 Fax J. Phillip Norris, P.E. Joseph K. Bland, P.E. Thomas J. Scheetz, F.I. 1VL Enclosed electronically is the application form, Sewer Narrative, sewer availability letter from the Cape Fear Public Utility Authority, 8 �/2 x 11 color USGS Topographic Map, site plan (ledger size) and a $480.00 check (to be mailed in) for the processing fee. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. d . 3t7 �6�- LA-'_ T. Jason lark, P.E. TJC/asn 20018 08-13-21-s-public-swr-Itr Enclosures NCBELS License C-3641 NORUS 4 TUN$TALL 2602Iton C4ty Drive, Suite 102 Wkn ngton, NC 29412 (91o)343-9653 (910) 34"604 Fax Johns, Tunstsity.H. T. Jason Ouk, RE, Rohbia P. Begneuy, E.I. August 13.2021 NC DEQ Division of Water Resources Water Quality Regional,Operations Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Gravity Sewer Extension Fast -Track Permit Application (Private) Flats at Hanover Center 3500 Perk Avenue New Hanover County N&T Projed No. 20018 Door Sir or Madam: 1429 Ash-Utde Rivet Roan Ash; NC 29420 (910) 297-5900 (910) 287S902 Fax J, Phillip.Nortis, P.E. Joseph K Bh4 P.E. Thomas J. Scheeix, Ed. Enclosed electronically is the application form, Sewer Narrative, Flow Tracking f Acceptance Form (FTSE 10-1$) with sewer availability letter from the Gape Fear Public Utility Autho(4, 8 % x 11 color US65 Topographic Map, site plan (tWger size) and a $480.00 check (to be mailed in) for the processing fee. Please review this information for approval and contact us with any questions or comments you may have, Thank you for your assistance on this project. Sincerely, NORRIS,& TUNSTALL `CONSULTING ENGINEERS, P.C. " T. Jason rk, P.E. TJCfasn 20013 05.1321 alu vats-swr•Itr Enclosures NCBPr.S License C-3641 North Carolina Secretary of State Search Results https://www.sosnc. gov/on line_services/search/Business_Registrati... • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings Limited Partnerships Legal. Name New Market - Hanover, L.P. Information Sosld: 1926318 Status: Current -Active O Date Formed: 12/2/2019 Citizenship: Foreign State of Incorporation: DE Annual Report Due Date: Registered Agent: Vcorp Services, LLC Addresses Reg Office Reg Mailing 160 Mine Lake Court Ste 200 160 Mine Lake Court Ste 200 Raleigh, NC 27615 Raleigh, NC 27615 Mailing 3284 Northside Parkway, N.W., Suite 150 Atlanta, GA 30327 Principal Office 3284 Northside Parkway, N.W., Suite 150 Atlanta, GA 30327 loft 8/26/2021, 4:09 PM SOSID: 1926318 Date Filed: 12/12/2019 12:57:00 PM Elaine F. Marshall North Carolina Secretary of State C2019 346 00404 State of North Carolina Department of the Secretary of State APPLICATION FOR REGISTRATION AS A FOREIGN LIMITED PARTNERSHIP Pursuant to §59.902 of the General Statutes of North Carolina, the undersigned hereby submits this application for Registration as a Foreign Limited Partnership for the purpose of obtaining a Certificate of Authority to transact business in this State. 1. The name of the foreign limited partnership is: New Market — Hanover, L. P. 2. If the name of the foreign limited partnership Is unavailable for use in the State of North Carolina, the name the limited partnership wishes to use is: (The name must contain the words "Limited Partnership," or the abbreviation "L.P." or "LP," or the combination "Ltd. Partnership".) 3, The Jurisdiction in which the limited partnership was formed is Delaware and the date of formation was 12amo+9 The limited partnership's period of duration is Perpetual 4. The street address of the principal office is: Number and Street:3284 Northslde Parkway, N.W., Suite 150 City: Atlanta State: GA Zip Code: 30327 County: Fulton The mailing address,ljdl,Q"erentfrom the street address, of the principal office: Telephone: 770-818-4108 Number and Street: City: State: Zip Code: County: 5. Name of Registered Agent: Vcorp Services, LLC 6. Address of Registered Agent's Office: Number and street: 160 Mine Lake Court, Suite 200 City: Raleigh State: NC Zip Code: 27615 County: Wake The mailing address, If different from the street address, of the registered office: Number and Street: City: State: NC Zip Code: County: NOTES: Piling roc Is $Sd. TTB document must be filed with the Secrcmry of State BUSIMS REGISTRATION DIVISION P.O.BOX 29622 RALEIGH, NC 27626-06222 (Revised August, 2017) Page I Form LP-04 7. In consideration of the issuance of a Certificate of Authority to transact business in North Carolina, the limited partnership appoints the Secretary of State of North Carolina as the agent to receive service of process, notice or demand, whenever the foreign limited partnership fails to appoint or maintain a registered agent in this State, or whenever such registered agent cannot with reasonable diligence be found at the registered office. 8. (Optional): Please provide a business e-mail address: The Socrelary of State's Office will e-mail the business automatically at the address provided at no charge when a document is fried. The e-mail provided will not be viewable on the website. For more information on why this service Is being offered, please see the instructions for thls document. 9. linter the name and address of each general partner: (attach additional sheets irnuacssury) New Market Hanover GP, LLC SU=t/No.3284 Northslde Parkway, N.W., Suite 150 ,.,,,Atlanta statercipGeorgia, 30327 10. Limited Partners (select I or 2, as appropriate) ❑ Attached Is a list of the names and addresses of all limited partners (include full name/street address/city/state/zip code/county); or ❑X The location of the office where list of the names and addresses of the limited partners and their capital contributions will be kept as long as the limited partnership transacts business in North Carolina is: Number and Street: 3284 Norlhside Parkway, N.W., Sulte 150 City: Atlanta State: GA Zip Code:30327 Cuunty: Fulton 11. (Select one) ❑ The foreign limited partnership is a foreign limited liability limited partnership. ® The foreign limited partnership is not a foreign limited liability limited partnership. 12. This registration will be effective upon filing, unless a future dale and/or time is specified: Title NOTES: PalnareebS50. Tfelr dacament mmt be mfed w0h the Secretory orStnte , L.P. Authorized Person of Now Marko[ Hanover GP, LLC BUSINESS REGISTRATION DIVISION P.O.BOX 29622 RALEIGH, NC 27626-06222 (Revised August, 2011) Page 2 Form LP-04 State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T .0300 -FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlston of Water Resources 11 11'' FTA 04.1E & SUPPORTING DOCUMENTATION Application Number. W Q VU ((2 )�10 be wmpWcd by DWtt) All items must be completed or the application WIlI be returned 1. APPLICANT INFORMATION: L Applicant's name: New Market - Hanover. L.P (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ® General Patfienhi p 0Privately-0wned Public Utility ❑ Federal ❑ StateJCounty ❑ Municipal ❑ Other 3. Signature authority's name: Jeffrey Sprain per 15A NCAC 02T 0106IbJ Title: Autboriaed Person 4. Applicant's mailing address: 32M No-ghside Parkway NW. Suite Ii0 City: Atlanta State: QA Zip: 30327-_ 5. Applicant's contact information: Phone number. aM 635-3,390 H. PROJECT INFORMATION: Email Address: dh�rry(a_ .com 1. Project name: Flats at Hanover Center 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ00_ and issued date: _ If new construction but part of a master plan, provide the existing permit number WQ00_ 3. County where project is located: Now Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 342185° Longitude:-2L2M69 5. Parcel ID (if applicable): R95517-001-001.000 t RO551? 01-00 -000 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: T. Jason Clark. P.E. License Number. 030869 NC Firm: Norris & Tunstall Consulting Engineers. P.C. Mailing address: 2602-Iron Gaza Drive, Suite 102 City: Wilmington State: & Zip: za412-_ Phone number: (20 341-2W Email Address: klarkralnteneineers cons & gMnj @gtM1 nears com IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: L Facility Name: James A Lm,ghlin (Northside W WTP) Permit Number: NCM3965 Owner Name: Cape Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (If different than WWTF): PermitNumber(s): WQ_ System Wide Collection System Permit Number(s) (if applicable): WQCS_ Owner Name(s): Cape Fear Publk (Utility Authority FORM: PTA 04-16 Page 1 of 5 VI. GENRRAL. REQUIREMENTS 1. If the Applicant is a Privately -Owned Public utility, has a Certificate of Public Convenience and Necessity been attached? C] Yes ONO INNIA 2. If the Applicant is a Developer of lots to be sold, has a D 212li ' s,Opararional A&Mment (EORM, DEV) been attached? ❑ Yea []No ON/A 3. If the Applicant is a 116m0rpneety Ofttra' Associkllnn fiat an pgmpstiial Agamnt 109M: H©A) been attached? ❑ Yes ❑No MNlA 4, Origin of wastewater: (check all that apply): [j.RasidetitdalOwned Retail (storm centers, malls) ❑ Car Wash ® Residential Leased Rot a with food preparation/service ❑ Hotel and/or Motels School f preschool / day care Medical I dental / veterinary facilities ❑ Swimming Pool /Clubhouse Food and drink facilities Church ❑ Swimming Pool/Fii(or Backwash Businasses I offices / factories Nursing Homo ❑ Other (Explain in Attachment) 5. Nature of wastewater : IR% DomtaticlCammercial _' *Commercial % Industrial Qm lsA NCAC aft' .0t03f201) "Is them a Pmtreatmeut Program in effect? ❑ Yes ❑ No 6. Hasa flow reclaotioa been approved tinder t5A Nf ,0 t14tfl7 C7 Yes ®No F if ya, provide *.cony of (dtw reductlom anbroval tatter 7. Summarize wastewater generated by project: Establishment Type (see 02 t �Rtdt (Daily Design Flow.p No. of Units Flow Pi/ GPD gaU GPD fsev GPD gaU GPD gaU GPD gav GPD Total 0 GPD a Soo l5A 8CAC 02T 0114tb1 fdl feNi) a' for for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown tan-reskfattial development uses; public access facilities located near high public use avow; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined b Per 1 SA 14CAC 02T .0114(c), design flow rates far establishments not identified (in table 15A NCAC 02T.01I4) shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: 2 GPD (per RSA NCAC 0 T 9114) 9 Do not include future flows or previously permitted allocations ff permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Plow has already been allocated in Permit Number: 21 Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): — our. FORM: FTA 04-16 Page 2 of VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) -=A308c jt� ttravkv �ewersl: 1. Summarize gravity sewer to be permitted: Size (Inches) tAngth(feet) Material 8" 213 PVC N"Tiv0owg (VrivaA �RbY . D�•b3�-1 D Section Il d: ill of the MDC for Permitting of Gravity Sewers contains hifomtation related to design criteria D Section Ili contains information telated to minimum step a ftlr gravity sewers) ➢ Overslzing lines to meet minimum slope requirement Is not allowed and a violation of the MIX V1H. PUMP STATION DESIGN CRITERIA (if Applicable) —JZLJM &MW(pampSIEWIlfbtyewhisl: COMPLETE FOR EACH PUMPSTATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. ApproximateCoordinates (Decimal Degrees): Latitude Longitude: 3, Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational points) of the pump(s): _ gallons Per mbwte at _ foal total dynamic head (TDR) S. Summarize the force, main to be permitted (for this Pump Station): Size (inches) Leogth(feet) Material 6. Power reliability in accordance with I5A NCAC Qno305"l): ❑ Standby power source or pump with automatic activation and telemetry • 15A NCAC 02T .0305(h)(i )(8)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day % Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(l)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - I SA NCAC 02T .0305(hXlXQ: D It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations, storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 Ix SETBACKS dt SEPARATION$ (028.11M & ISA NCAC 62T ,0305(f)): Does the project can ply all separatim found in 13A NCAC 02T .0305tf1'd, (a) ® Yes ❑ No ➢ 15A NCAC 02T.0305ffl contains minimum s eassradenc th u .twn hn �,rid.A v� Setback eter• ( - - Separation Requited torn and other utilities not listed below vattic 24 inches Wa . mains v 'cal -water over Sewer irwhidiox in beached trenches IS itches Water mains ttal 10 feet Roclabod water lines `Vertical - reclaimed over sower 1$ iaches Raataimed water lines - reclafined over sewer 2 feet "Any private or public caster supply soom including any wells, WS-I waters of Class I or Clog,impounded reservoirs used as a source of drinking water I00 fat "ftw classi$ed WS (except ws-i or WS-Y), B, SA, ORW, HQW, or SB from normal high wets or tide elevation and wetlands a" key, ix.11 50 feat "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any buildinstfoundatip., 5 feet Any basement 10 feet TOP slope of embankment or cute of 2 feet or more vertical hc!&La 10 feet Dr#ivaa systems and Interceptor drains 5 feet Any swimmint pools 10 feet Final earth asdo LYSLmp 36Inches ➢ 1S NCCAC 02T.tt3iS5TdS contains alternative& where seperati era in i cannot be achieves. aStream olasaifmations can: be identified using the Division's `� l gter CIan; =JJ'M weboa� ➢ if nancomplisma with 02'P 030 WAt a sea Sectkm X of this application 2. Does, Use project comply with separation tx Irements for wetlands? (50 feet of separation) ® Yes ❑ No D Soo the Division's drag separation requirements for sitvationa where separation cannot be meet ➢ No variance is repaired if the atternattve design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found is the river basin rules per ISA NCAC 02B0200? gym ❑ No ➢ This would include Tlrout Buffered Streams per ISAtI��C 2B 0102 4. Does the project comply withanindividual 404 Permit or any 401 Certifications? ® Yes ❑ No • Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters • Information can be obtained from the 40 t A Hu kEMaftu ftMgb 5. Does proea cmmply with l5A NCAC 02T.0105(i i0 (additional permitsfeertificadons)? ®Yes ❑ No Per 15A NQ&Q— t12T 0to5L", directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. )ssuartce of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this Project include any sewer collection Imes that are deemed "high-priorityT' Per 13A N A 02C T-0442. "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewer Positioned parallel to strearnbanks that is subject to erasion than undermines or deteriorates the sewer. + ® Yes ❑ No ��ttse , t s Ipk ' 4d Uat R.�_.l�l k ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). Mgb priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per ISA NCAC 02T.0403(a}(S) or the permitee's individual System -Wide Collation permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS- . Does the sabmttted system amply with and ears tulalnar(•+eat vera.Unl and the IPNe' complete and review. Aoorovatc 2. Pr Atmmmhvat)estgnR uestWiflieation(VADCf0-14)andsupportingdocumentsfor has been reviewed by me and a accurate, complete and conastent with the in engineering caiauladow, and all otter stnppo"kil documentation to the beat of of my knowledge the proposed design hee been prepared. in accordance w Minimum Dedgn Criteria fbr Gravity Sew*% (lstest vendaiij, and the MhOr"m Of Pump Stations and Foina Mains (latest version). Although Otter proibssioha submittal package, htc1010e of thee- tnate lah under my signanire and seal s have judged it to be CM41 NI with the proposed design. NOTE — In accordance with General Statutes t43-215.6A and 143.215,6B, statement, r cs"6on, or txztificadhm is any application package shall be include a fine not to exceed $10,000. as well as civil penalties Up tQ $25,IN pit North Carouns Prormloaal Eagtacers seat, signslare, and date; 3. Applicant's Certification per i5A NCAC 02T .0 that this application for m supplied in the plans, speeificatims, wledga I Potthar attest dial to the bet applicable teguladoas. Oravity Sewer t Criteria fur the Past-` mk Patmitting have devg4W certain portions of this that I Have reviewed (his material and A i who knowingly mattes any false Class 2 misdemeanor, which may that this applicadw for has been reviewed by are and is accurate and complete to the best of my knowledge. I understand that if all required parts of this appiitat(ion are, W completed and that If all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater rrrnn this non- dischorgp system to surihco wanes or dw1and will resuh In sn Immediate enforcement action that may include civil penalties, injunctive rclio� andlor crimltal prosecution. I will make no claim against die Division of Water Resources should a condition Of this permit be violated. I also understand that Wall required parts Of this application package am not completed and that if all required supporting information and attachments are not included, this application package will bo returned to me as incomplete, NOTE — in accordance with Ooncral Statutes 141-213.kA and iAi.2= any person who knowingly makes any false statement, repr6sealatiqii. or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a tine not toe 10,000 as well as civil penalties up to $25,000 per violation. Signature: FORM: FTA 04-16 Page 5 of 5 NT-a.W �Wi 4A ) State. of Norm caro)ivatt DopartmcRt Of Enviromnental Qualky Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Apphtcattons (F'f8E ma) Entity Requesting Allocation: New Market - Hanover. L.P. Project Name for which flow is being requested: Flats at Hanover Center More dramone FUR arayberegwmdfo+'mairplep►VAWVheomerofAWWWMbsotresponsiblefordipump sta[foas aleaF lire mats ofthe propssaf wurwer flow 1. Complete this section only if you are the owner of the wastewater treatment plant. a, WWTP Facility Name: James A. l:ou�orthside)WWTP b. WWTP FUMY Permit #: NPDES NC 0023965 a WWTP facility's permitted flow AUflonic are 16.000 I Estimated obligated flow mot yet tributary to the WWTP 3.812 e, WWTP facility's actual avg. flow 10.661 f. Total flow for this specific request 0,079100 $. Total actual and obligated flows to the facility 14,552 IL Percent of permitted flow used Otto IL Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump PUMP Station Station (Nana or Permit Number) No. (a) M Design Avetage Approx. Daily Cumut Firm Flow** Avg. Duly Capacity, * (Firm / pf), Flow, MGD MGD MGD 10 W00039922 22.090 7.363 (C) (DMB+C) (9)=(A-D) Obligated, Not Yet Total Coamnt Tributary Flow Plus DallYFlow, Obligated Available MGD Flow capacity"41 3.472 0.721 4.193 3.171 * The FSiva Capacity (design Bow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Des9Yn Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (110 Act less than 2.5, per Section 2.02(A)(4xc) of the Minimums Design Criteria. *** A Planning Assessment Addendum shall be attached for each pomp station located between the proJed connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Cape Fear Public Utility Authority Downstream Permit Number: Page 1 of 6 ❑TQV in ,o III. Certification Statement: I Jeff Theberge, CFPUA Eng. Mgr certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. GN GINFL"IZ1N( /"IANA(Ei Title of Signing Official Page 2 of 6 UTQR in 10 SEWER NARRATIVE (PRIVATE & PUBLIC) FLATS AT HANOVER CENTER 3500 Park Avenue Wilmington, North Carolina m New Market— Hanover, L.P. 3284 Northside Parkway, NW, Suite 150 Atlanta, GA 30327 (770) 635-3390 Revised May 2021 (Per CFPUA Comments) March 2021 Prepared by: NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. 2602 Iron Gate Drive, Suite 102 Wilmington, North Carolina 28412 (910) 343-9853 (910) 343-9604 (Fax) License # C-3641 N&T Project #20018 (Private & Public) NARRATIVE (PRIVATE & PUBLIC) SEWER SYSTEM: This submittal is for the development of the Flats at Hanover Center project, located at 3500 Park Avenue, Wilmington, NC. The development of this project will include a new demand of 79,100 GPD. Private: The development of the Flats at Hanover Center is removing 195 LF of existing 8-inch Private gravity sewer due to its location within the tract to be developed. The development will include 213 LF of new 8-inch PVC gravity sewer to re-route the sewer around the newly proposed building. There is zero (0) new flow entering this Private portion of the project. The existing WQ Permit number is unknown. Public: The rerouting of the Private sewer results in a small extension of the Public portion of the sewer. There is also a new public section under Park Avenue to serve Building 1. The Public sewer is being extended by 185 LF of 8-inch PVC Gravity Sewer. New flow to Public is 79,100 GPD. The existing WQ Permit number is unknown. This system will be served by the Cape Fear Public Utility Authority. — I M RK AVF I IF T o. I. SCALE 1"=3e a I SCALE. r'=in rlon'ae.nan s �.�r.ra 9b) N1 __ nn• .. IJ��)B'S5 ��5 IEE �m 2W18 I I o %�`L , uy r m ate' 1LC 2AM /.Y T i I f I • f • F � i C2.1 �a Ensnnc ZZ FaL rv' a. PRAY 1 ---------�-------- la II i I SLhLE�i'--3�p rC2.2