Loading...
HomeMy WebLinkAboutSW6211001_Design Calculations (Drawdown, Pond 2)_20211014Wayside Apartments Pond 2 Drawdown Time Temporary storage volume = Orifice #Idiameter= Area of orifice = Orifice #2 diameter = Area of orifice = Orifice Coefficient (Cd) _ Orifice elevation -- Water elevation --- Driving head (H) _ Discharge (Q) _ Drawdown time = 13,030 cf 1.75 in 1 0.0167 sf 0 in 0 0.0000 sf 0.60 251.50 ft 253.48 ft 0.66 ft 0.0653 cfs 199397 s 55.4 hr 2_3 days 927-POND 2 drawdown.xlsx Printed 10/14/2021