HomeMy WebLinkAboutNC0027103_Lab Inspection_20021209�L r Michael F. Easley, Governor ,- William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality December 9, 2002 552 Ms. Rhonda Locklear Town of Pembroke Wastewater Laboratory P. O. Box 866 Pembroke, NC 28372- SUBJECT: Laboratory Certification Maintenance Inspection Dear Ms. Locklear: 'DEC I 0 2002 Enclosed is a report for the inspection performed on November 25, 2002 by Mr. Frederick L. Bone. Where deficiencies are cited in this report, a response is required as well as for all lettered comments and/or recommendations. Within thirty days of receipt, please supply this office with a written item for item description of how these deficiencies, comments and/or recommendations were corrected. If the deficiencies cited in the enclosed report are not corrected, enforcement actions will be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC for 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. Please contact us at 919-733-3908, if you have questions or need additional information. Sincerely, G2�tne4 WM� James W. Meyer Laboratory Section Enclosure cc: Frederick L. Bone Fayetteville Regional Office NCDNR Laboratory Section N. C. Division of Water Quality 1623 Mail Service Center Raleigh, NC 27699-1623 (919) 733-3908 Fax: (919) 733-6241 Internet: dwglab.org Customer Service 1-800-623-7748 On -Site Inspection' Report LABORATORY NAME: Pembroke VWVfP ADDRESS: P.O. Box 866 Pembroke, NC 28372 CERTIFICATE NO: 552 DATE OF INSPECTION: November 25, 2002 TYPE OF INSPECTION: Maintenance EVALUATOR: Frederick L. Bone LOCAL PERSON(S) CONTACTED: Rhonda Locklear I. INTRODUCTION: This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The laboratory is spacious and well equipped. All facilities and equipment are well maintained. Records .are well kept and most data looked good. Some further quality control procedures need to be implemented. III. DEFICIENCIES, RECOMMENDATIONS, REQUIREMENTS, AND COMMENTS: General: A. COMMENT: The laboratory is reporting all preservation check data as "0". REQUIREMENT: All data must be reported as less than the lowest standard concentration demonstrated by the laboratory. In the case of preservation checks, the data should be reported as less than the detection limit of the test method used. Residual chlorine preservation checks should be documented as < 0.5 mg/L when tested with KI paper. Dissolved Oxygen: B. COMMENT: The influent sample taken for dissolved oxygen is not measured immediately upon sample collection, but is transported to the laboratory fo.r analysis. Effluent samples are measured immediately. REQUIREMENT: All dissolved oxygen measurements must be taken immediately at the site of collection. Ref: 40CFR Ch.1(7-1-95) p. 644 table II. RESIDUAL CHLORINE: C. COMMENT: The recovery of the lower reporting limit standard in two out of three analytical curves reviewed did not demonstrate acceptable recovery limits. The laboratory is reporting a detection limit Page 2 of 0.2 mg/L. The low reporting limit concentration recovered for each of the three curves is as follows: 0.3 mg /L, 0.4mg/L and 0.2 mg/L. REQUIREMENT: The recovery of the low reporting standard must be within three times the standard deviation of the true value or the 99 percent confidence interval. The low standard must therefore be within approximately 25% of the true value. The laboratory must reanalyze the analytical curve and demonstrate the capability of accurately achieving the detection limit standard. Note: The analytical curve used by the laboratory is from 0.2 mg /L to 2.0 mg/L. The laboratory may consider shortening the analytical curve range used for residual chlorine analysis. By decreasing the total overall linear range, the laboratory should be able to increase the sensitivity in the lower range of the analytical curve. This increased sensitivity will lead to better recoveries of the detection limit standard. D. COMMENT: The laboratory is analyzing a DI water blank daily, but does not perform a reagent blank each analysis day. RECOMMENDATION: The laboratory should zero their instrument with the DI water blank. The laboratory should then analyze the reagent blank in which the DPD colorimetric reagents are added to the DI water. ,This will allow the laboratory to determine any interferences caused by laboratory contamination or reagent interference. Total Suspended Solids and Total Solids: E. COMMENT: The laboratory does not record the time and date that the samples were placed info the oven and time and date that the samples were removed from the oven on the bench sheet for the drying time verification study. REQUIREMENT: Dry evaporated sample for at least 1 hour 'in an oven at 103 the 105°C, cool in desiccator to balance temperature, and weigh. Repeat cycle of drying, cooling, desiccation, and weighing until a constant weight is obtained, or until weight change is less than 4% of previous weight or 0.5 mg, whichever is less. Ref: Standard Methods 18th Edition 2540 B Total Solids at 103=105° C section (3) b p2-54. IV: PAPER TRAIL INVESTIGATION: This consisted of comparing data reported on DMR's submitted to this Division with the values obtained on laboratory bench worksheets. Data reviewed for the months of January, July, and September 2002 indicated no problems in proper data reporting. V. CONCLUSIONS: Correcting the above cited comments and implementing the recommendations should help them to produce quality data and meet certification requirements. Please respond to all lettered Comments cited in this report. Report prepared by: Frederick L. Bone Date: November 26, 2002 Town of Pembroke Wastewater Laboratory Town of Pembroke P.O. Box 868 Pembroke NC, 28372 Phone: 910- 521- 2989 Fax: 910-521-2343 Corrective Action -Response Laboratory Name: Pembroke WWTP Address: P.O. Box 866 Pembroke, NC 28372 Certificate No: 552 DM; �1 nI�lL11: O f CGIOE1L , � 97CE REPORTED BY: Rhonda Hagan Locklear is. 11 1�) II L DENR FA I r_ ILL E REGIONAL OFFICI I. GENERAL DEFICIENCIES, RECOMMENDATIONS, REQUIREMENTS, AND COMMENTS: GENERAL: A. COMMENT: The laboratory is reporting all preservation check data as "0". Correction: We are currently documenting residual chlorine preservation checks as < 0.5 mg/1 when tested with KI paper. DISSOLVED OXYGEN: B. COMMENT: The influent sample taken for dissolved oxygen is not measured immediately upon sample collection, but is transported to the laboratory for analysis. Effluent samples are measured immediately. Correction: The laboratory does not measure dissolved oxygen at the influent , only effluent dissolved oxygen. RESIDUAL CHLORINE: C. COMMENT: The recovery of the lower reporting limit standard in two out of three analytical curves reviewed did not demonstrated acceptable recovery limits. The laboratory is reporting a detection limit of 0.2 mg/I. The low reporting limit concentration recovered for each of the three curves is as follows: 0.3 mg/I, 0.4 mg/I and 0.2 mg/I. Correction: The laboratory is creating new calibration curves. D. COMMENT: The laboratory is analyzing a DI water blank daily, but does not perform a reagent blank each analysis day. Correction: The laboratory is currently preparing a analysis blank daily. TOTAL SUSPENDED SOLIDS AND TOTAL SOLIDS E. COMMENT: The Laboratory does not record the time and date that the samples were placed into the oven and time and date that the samples were removed from the oven on the bench sheet for the drying time verification study. Correction: The laboratory has modified drying time verification bench sheet to reflect all times. 2