Loading...
HomeMy WebLinkAboutWI0700013_Lab Results_20211012AC88768 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: W10700013 County: Currituck Collector: R SIPE VisitlD Influent Region: Washington Report To WARO Location ID: WARO NLC River Basin PAS Collect Date: 08/19/2021 Priority COMPLIANCE Emergency Collect Time: 11:00 Sample Matrix: GROUNDWATER COC Yes/No Sample Depth Loc. Type: Geotherm Supply Well Final Report Sample ID: AC88768 PO Number # Date Received: 08/20/2021 Time Received: 08_25 Labworks LoginiD TASCENZOI Delivery Method NC Courier Final Report Date: 10/5/21 Report Print Date: 10/09/2021 If this report Is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result/ CAS # Analvte Name PQL Qualifier LAB Sample temperature at receipt by lab 1.1 Units °C Method Analysis Reference Date Validated by 8/20/21 ESTAFFORD1 Coliform, MF Fecal in liquid MIC 1 1 B2,Q1 CFU/100m1 SM 9222 D-1997 8/20/21 JJURGEVICH Coliform, MF Total in liquid 1 1 132,01 CFU/100ml SM 9222 B-1997 8/20/21 JJURGEVICH 14797-55-8 Nitrate as N in liquid NUT 0.02 0.70 mg/L as N EPA 353.2 REV 2 8/25/21 ALWILLIAMS 14797-65-0 Nitrite as N in liquid 0.01 0.01 U mg/L as N EPA 353.2 REV 2 8/20/21 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0.02 0.70 mg/L as N EPA 353.2 REV 2 8/25/21 ALWILLIAMS 24959-67-9 Bromide WET 0.4 0.4 U mg/L EPA300.0 rev2.1 9/16/21 ALWILLIAMS 16887-00-6 Chloride 1.0 23 mg/L EPA300.0 rev2.1 9/16/21 ALWILLIAMS 18984-48-8 Fluoride 0.4 0.4 U mg/L EPA300.0 rev2.1 9/16/21 ALWILLIAMS 14808-79-8 Sulfate 8.0 48 p mg/L EPA300.0 rev2.1 9/16/21 ALWILLIAMS Total Dissolved Solids in liquid 12 157 mg/L SM 2540 C-1997 8/23/21 ALWILLIAMS 7429-90-5 Al by ICP MET 50 50 U ug/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.8 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-70-2 Ca by ICP 0.10 24 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 56 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7439-89-6 Fe by ICP 50 7600 ug/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-09-7 K by ICP 0.10 3.7 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7439-95-4 Mg by ICP 0.10 4.3 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7439-96-5 Mn by ICP 10 120 ug/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-23-5 Na by ICP 0.10 15 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-02-0 Ni by ICPMS 2.0 4.3 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.2 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-66-6 Zn by ICPMS 10 440 P ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 1 of 3 WC 'DWR Laboratory Section Results/Sample Comments/Qualifier Definitions Sample ID: AC88768 CAS # Analvte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by Sample Comments MIC:Fecal Coliform-B2-Counts from all fillers = 0. MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt al lab. NCDEQ-WSS-ChemistryLab Data Qualifiers At The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 mi that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 7333908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 WC DIAL Laboratory Section qjstets/Sample Comments/Qualifier Definitions Sample ID: AC88788 CAS # Analvte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower • N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of 2 N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at if ✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. 21 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 3 of 3 AC88769 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Desor.: WI0700013 County: Currituck Region: Washington River Basin PAS Emergency COC Yes/No Collector: R SIPE Report To WARD Collect Date: 08/19/2021 Collect Time: 11_15 Sample Depth Visi11D Effluent Location ID: WARO NLC Priority COMPLIANCE Sample Matrix: GROUNDWATER Loc. Type: Geotherm Supply Well Final Report Sample ID: PO Number # Date Received: Time Received: Labworks LoginID Delivery Method Final Report Date: Report Print Date: AC88769 08/20/2021 08_25 TASCENZOI NC Courier 10/5/21 10/09/2021 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. CAS # Analvte Name Sample temperature at receipt by lab PQL Result/ Qualifier LAB 1.1 Units <C Method Analysis Reference Date Validated by 8/20/21 ESTAFFORD1 MIC Coliform, MF Fecal in liquid 1 B2,Q1 CFU/100m1 SM 9222 D-1997 8/20/21 JJURGEVICH Coliform, MF Total in liquid 1 1 B2,Q1 CFU/100m1 SM 9222 B-1997 8/20/21 JJURGEVICH 14797-55-8 Nitrate as N in liquid 0.02 NUT 0.72 mg/L as N EPA 353.2 REV 2 8/25/21 ALWILLIAMS 14797-65-0 Nitrite as N in liquid 0.01 0.01 U mg/Las N EPA 353.2 REV 2 8/20/21 ALWILLIAMS E701177 NO2+NO3 as N in liquid 0.02 0.72 mg/Las N EPA 353.2 REV 2 8/25/21 ALWILLIAMS 24959-67-9 Bromide 0.4 WET 0.4 U mg/L EPA 300.0 rev2.1 9/16/21 ALWILLIAMS 16887-00-6 Chloride 1.0 24 mg/L EPA 300.0 rev2.1 9/16/21 ALWILLIAMS 16984-48-8 Fluoride 0.4 0.4 U mg/L EPA 300.0 rev2.1 9/16/21 ALWILLIAMS 14808-79-8 Sulfate 8.0 46 P mg/L EPA 300.0 rev2.1 9/16/21 ALWILLIAMS Total Dissolved Solids in liquid 12 155 mg/L SM 2540 C-1997 8/23/21 ALWILLIAMS 7429-90-5 Al by ICP 50 MET 50 U ug/L EPA 200.7 Rev4.4 9/10/21 JJURGEVICH 7440-38-2 As by ICPMS 2.0 2.5 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-70-2 Ca by ICP 0.10 23 mg/L EPA 200.7 Rev4.4 9/10/21 JJURGEVICH 7440-47-3 Cr by ICPMS 5.0 5.0 U ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-50-8 Cu by ICPMS 2.0 160 P ug/L EPA 200.8 Rev5.4 9/10/21 JJURGEVICH 7439-89-6 Fe by ICP 50 8000 ug/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-09-7 K by ICP 0.10 3.6 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7439-95-4 Mg by ICP 0.10 4.3 mg/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7439-96-5 Mn by ICP 10 130 ug/L EPA200.7 Rev4.4 9/10/21 JJURGEVICH 7440-23-5 Na by ICP 0.10 15 mg/L EPA 200.7 Rev4.4 9/10/21 JJURGEVICH 7440-02-0 Ni by ICPMS 2,0 2.8 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7439-92-1 Pb by ICPMS 2.0 2.3 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH 7440-66-6 Zn by ICPMS 10 71 ug/L EPA200.8 Rev5.4 9/10/21 JJURGEVICH WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699.1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 1 of 3 NC D'GNR, Laboratory Section 7esufts/Sampre Comments/Quahfi'er Definition Sample ID: AC88769 CAS # Analvte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by Sample Comments MIC:Fecal Coliform-B2-Counts from all filters = 0. MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt at lab. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cab B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 nil that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J10 Unidentified peak; estimated value. WSS Chemistry Laboratory» 1623 Mall Service Center, Raleigh, NC 27699.1623 (919) 733.3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 2 of 3 NC DIA, Laboratory Section 74suCts/Sample Comments/Qualifier Definitions Sample ID: AC88769 CAS # Analyte Name PQL Result/ Qualifier Units Method Reference Analysis Date Validated by J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of e N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. P Elevated PQL* due to matrix interference and/or sample dilution. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt ✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733.3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the POL. Page 3 of 3 LL 4, N O Water Sample Collection & Submittal Form 0 u 3vi 0 v 0u ¢ cc U L a a a z Delivery Method a o — m E 3 i « c `g� " t E ,O m • .. SP a t z vO O w w 17. o t 'o ry 0 3 m a o VO t o0 ycc z 0 C61 a V ea d E E V a ro N W 0 1 c/ / ^J \Ll r J 1-J N G E 3 V Preservative UJ ILI UJ LIJ UJ LIJ a a a a V ¢ Metals Parameters Con E To r F ti £ i 0 0 m0 Hardness, Total ascac0 Organics Parameters: Acid Herbicides Organochlorine Pesticides a n 0 O 0 Organophosphorus Pesticide PCBs (polychlorinated biphenyls) Organics (BNAs) E 4 cc 0 r Volatile Organics (VOA) 0 4 TPH Gasoline Range Perfluorinated Compounds (PFAS) 0 m Phytoplankton / Algae F E 0 o i b Ll LLI UJ LU LIJ UJ 111 LIJ UJ UJ LLI ILI LU 0 -,A a Metals Parameters: E 'c E E Q 0 E m E 0 co E E V £ 0 V 0 0 V xx 0 v V n V c 0 a ?QC.X E 2 E f 0 5 xx 0 0 2 2 E a 2 0 2 E 0 x 0 N 0 E 0 i z v ¢ a ¢ ¢ ¢ Q ¢ a ¢ 5 ¢ ¢ ¢ Wet Chemistry Parameter 0 m fro 0 Color: ADMI Color: Platinum Cobalt COD: Chemical Oxygen Demand Cyanide, Total Hexavalent Chromium (Cr6+) MBAS(surfactants) Oil and Grease, HEM, Total Recoverable 0 4, 0 Residue: Total (Total Solids) Residue: Volatile/Fixed, Total Residue: Settleable Residue: Volatile/Fixed, Suspended 0 0 0 0 Tannin & Lignin Water Temp ("C): v b ¢ m m a ¢ ¢ ¢ a Microbiology Parameter Alkalinity, as CaCO3, to pH 4.5/8.3 BOD: Biochemical Oxygen Demand, 5-day cBOD: Carbonaceous BOD, 5-day ,73 E O L To E O TOC - Total Organic Carbon 0 Other Parameter Nutrients Parameter 2 0 z 0 0 Total Phosphorus as P (TP) 0 z Nitrate as N (NO3-N calculated) Orthophosphate as P (PO4) 0 0 0 5 q OI oi 2 4' 0. y o z 0 E nIC o IC , 2 o z so m 3 as v v y 0 o 0 2 v 2 3 n v_ 2 N 2 u ' n ry o = 6 n O u 6`0 2 o. x `0 n 0 O u i E EE m 1 Lab Use Only: Water Sample Collection & Submittal Form c o_ C 0 d 03 t 7c .0 n 0 J 2 0 u 0 0 0 9 e p a 0 u 0 Delivery Meth 0 2 ell S a 2 0 a N LL 0 v — 0 Q 0 0 4.V w O 0 u0 V E V C CC 0 a r C m K 0 a -0 a 0 0 Lab Comment J Preservative Metals Parameters Con't: LU E r LU r LU E E 0 N 0 g O LU 1.4 0 ca 0 x Organics Parameters: Add Herbicides Organochlorine Pesticides Organonitrogen Pesticides V a `0 n r 0 0 2 m m 0 0 E h rc 0 r Volatile Organics (VOA) n 0 0 TPH Gasoline Range Perfluorinated Compounds (PFAS) 0 80 `0 0 E 3 o E u 0 b UJ UJ LLI LU LU LU LUI UJ LU LLI UJ UJ LU LJ UJ UJ w 0 o E n b E 2 Preservative a a `0 E Q Q 0) E m Q m 3 V E 3 V ¢ Q V ¢ CZ 0 ¢ E 2 ¢ Q Molybdenum (Mo) Q z 80 ¢ E 3 E N Q 0. E 0 • Wet Chemistry Parameter 0 E m a `0 V a 0 0 v Color: ADMI Color: Platinum Cobalt COD: Chemical Oxygen Demand Cyanide, Total Hexavalent Chromium (Cr6+) MBAS (surfactan a Oil and Grease, HEM, Total Reco Phenols, Total Recoverable Residue: Total (Total Solids) Residue: Volatile/Fixed, Total Residue: Settleable Residue: Suspended (Suspended Solids) a 0 s 3 Water Temp ("C): z u a Q Q Q Q Q V ¢ 0 a Q a ¢ Microbiology Parameter Alkalinity, as CaCO3, to pH 4.5/8.3 BOO: Biochemical Oxygen Demand, 5-day cBOD: Carbonaceous BOD, 5-day oliform: Fecal MF 0 E U TOC - Total Organic Carbon Other Paramete n Nutrients Parameter Ammonia as N (NH3-N) ice as N (NO3+NO2-N) 2 a e as N (NO3-N calcula 'z Orthophosphate as P (PO4) O 5