Loading...
HomeMy WebLinkAboutSW5200401_Plansheet - Set_20211012Fla "kip, (ro lal k 4 Irv+ "� ea w. iw P �M1d Gujj w i SITE r ° N15 r s Lu f.o B4fvCl `' r VICINITY MAP 1 If = 1000' CALL 48 HOURS BEFORE YOU DIG CONSTRUCTION PLANS FOR 1075 S MAIN ST LOUISBURG, NORTH CAROLINA PINS: 2805-20-240412805-20-34961 AND 2805-20-6521 ENGINEER OF RECORD: FLM ENGINEERING, INC CONTACT: JON FRAZIER, PE PO BOX 91727 RALEIGH, NC 27675 919.610.1051 JFRAZIER@FLMENGINEERING.COM DEVELOPER: MOSS RENTALS, LLC CONTACT: MIKE MOSS 333 S WHITE ST WAKE FOREST, NC 27587 919.556,3148 MIKE@CMPPLS.COM POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 REVISION HISTORY REV DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 1 2 1 NCDEQ COMMENTS 1 4/9/2021 1 FLM I 1 3 1 NCDEQ COMMENTS 1 8/9/2021 1 FLM I 1 4 1 NCDEQ COMMENTS 1 10/7/2021 1 FLM I ORIGINAL PLAN SIZE: 24" X 36" SHEET TITLE C-1 COVER C-2 GENERAL NOTES C-3 CALCULATIONS C-4 EXISTING CONDITIONS & DEMOLITION PLAN C-5 SITE PLAN C-6 UTILITY PLAN C-7 GRADING & DRAINAGE PLAN C-8 SCM DETAILS C-9 EROSION & SEDIMENT CONTROL PLAN - PHASE 1 SCALE ADJUSTMENT C-10 EROSION & SEDIMENT CONTROL PLAN - PHASE 2 C-11 LANDSCAPING PLAN THIS BAR IS 1 INCH IN LENGTH C-12 TURN LANE PLAN ON ORIGINAL DRAWING C-13 TURN LANE DETAILS ° 1I. C-14 SITE DETAILS IF IT IS NOT 1 INCH ON THIS C-15 SITE DETAILS SHEET, ADJUST YOUR SCALE ACCORDINGLY C-16 STORM DRAINAGE DETAILS C-17 EROSION & SEDIMENT CONTROL DETAILS C-18 EROSION & SEDIMENT CONTROL DETAILS CONSTRUCTION PLANS C-19 NCG01 SELF -INSPECTION, RECORD KEEPING AND REPORTING C-20 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING MOSS BUILDINGS C-21 WATER AND SEWER DETAILS 1075 S MAIN ST C-22 BUA VERIFICATION PLAN I LOUISBURG, NC 27549 MOSS RENTALS, LLC DATE: 03-25-2020 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 COVER ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ STANDARDS AND SPECIFICATIONS SHEET 1 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. CONSTRUCTION SEQUENCE 1. EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE LAND DISTURBING ACTIVITIES OCCUR. 2. OBTAIN NCDEQ E&SC PERMIT AND NCG01 COC AND SCHEDULE A PRE -CONSTRUCTION MEETING WITH A RALEIGH REGIONAL OFFICE LAND QUALITY INSPECTOR A MINIMUM OF 72 HOURS PRIOR TO CONSTRUCTION BEGINNING. ADDITIONALLY, THE RALEIGH REGIONAL OFFICE MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO COMMENCING LAND DISTURBANCE. CONTACT THE RALEIGH REGIONAL OFFICE AT 919-791-4200. PHASE 1 1. PRIOR TO INSTALLING EROSION AND SEDIMENT CONTROL MEASURES, DEWATER EXISTING POND THROUGH A SILT BAG WITH A TOP DRAW DOWN / FLOATING INTAKE DEVICE. 2. ONCE THE EXISTING POND IS DEWATERED, INSTALL CONSTRUCTION ENTRANCE, AND WHEN COMPLETE, INSTALL THE PERIMETER SILT FENCE; TEMPORARY DIVERSION DITCHES; AND SKIMMER BASINS SK-1 AND SK-2. THE EXISTING POND SIDE SLOPES SHALL BE GRADED AS SHOWN ON THE PLAN TO PROVIDE THE NECESSARY SURFACE AREA AND STORAGE VOLUME FOR SEDIMENT BASIN SK-1. UPON COMPLETION OF INSTALLATION, IMMEDIATELY SEED, MULCH, AND ANCHOR EROSION AND SEDIMENTATION CONTROL MEASURES. 3. BEGIN CLEARING AND ROUGH GRADING OF SITE. ALL EXCAVATIONS PERFORMED SHALL BE BACKFILLED WITHIN THE SAME DAY WITH SPOIL PLACEMENT ON UPSLOPE SIDE. TEMPORARY DIVERSION DITCHES SHALL BE LINED WITH TEMPORARY LININGS AS SHOWN IN THE TABLE ON SHEET C-3 AND STABILIZED WITHIN 7 DAYS. STOCKPILE/STAGING ARES AND CONCRETE WASHOUT TO BE WITHIN LIMITS OF DISTURBANCE AND SHOULD BE LOCATED AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS, TEMPORARY DIVERSIONS, CHANNELS AND SURFACE WATER BODIES. SLOPES SHALL BE MATTED WITH NAG S75, OR EQUIVALENT. PHASE 2 1. INSTALL STORM SEWER AND PROTECT INLETS WITH INLET PROTECTION AS SHOWN ON THE PLAN. 2. BEGIN FINISHED GRADING, FILLING, AND COMPACTION OF SITE. PERMANENTLY STABILIZE THE SITE AS AREAS ARE BROUGHT UP TO FINISHED GRADE WITH PAVEMENT AND VEGETATION. SEE SHEET C-18 FOR SEEDING SCHEDULE. 3. ONCE SITE HAS BEEN PERMANENTLY STABILIZED, REMOVE SKIMMER BASIN SK-2 BY REMOVING ACCUMULATED SEDIMENT BY MEANS OF A SILT BAG AND RESTORING AREA TO NATURAL GRADE. REMOVE ALL TEMPORARY DIVERSION DITCHES. 4. UPON STABILIZATION OF THE ENTIRE DISTURBED AREA, CONVERT SKIMMER BASIN SK-1 TO STORMWATER WETLAND AS SHOWN ON THE APPROVED PLANS. PRIOR TO CONVERSTION, A TOP DRAW DOWN/FLOATING INTAKE SHALL BE USED TO REMOVE SEDIMENT LADEN RUNOFF VIA SILT A BAG, AND SEDIMENT SHALL BE REMOVED AND DISPOSED OF WITH APPROPRIATE EQUIPMENT. 5. ALL DISTURBED AREAS SHALL BE STABILIZED AND GROUNDCOVER SHALL BE ACHIEVED WITHIN 14 WORKING DAYS AND STEEP SLOPES SHALL BE STABILIZED WITHIN 7 DAYS, PER NPDES CONSTRUCTION STORMWATER GENERAL PERMIT NCG01. 6. THE CONTRACTOR SHALL CONDUCT SELF -INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES AND COMPETE THE FOLLOWING COMBINED SELF -INSPECTION FORM FOUND ON THE DEMLR WEBSITE HTTPS:HFILES.NC.GOV/NCDEQ/ENERGY%20MINERAL%20AND%20LAND%20RESOURCES/ STORMWATER/NPDES%20GENERAL%20PEMLITS/DEMLR-CSW-MONITORING-FORM-REV- AUGUST-8-2019.PDF. TWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON -SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. 7. SELF -INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL E&SC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS WITHIN THIS PLAN SET. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING. 8. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEEN FILLED OUT. 9. REMAINING MEASURES MUST BE REMOVED AND RESULTING BARE AREAS STABILIZED BEFORE PERMIT CAN BE CLOSED. CALL 48 HOURS BEFORE YOU DIG WATER AND SEWER SERVICE NOTES ALL WATER AND SEWER SERVICES SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG STANDARD SPECIFICATIONS. WATER SERVICE NOTES: 1. GENERAL REQUIREMENTS a) UPON REQUEST OF THE TOWN REPRESENTATIVE AND PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL SERVICE SADDLES SHALL BE USED FOR TAPS TO ALL WATER MAINS. DIRECT TAPS ARE NOT ALLOWED. SERVICE CONNECTIONS LARGER THAN 2" ON EXISTING WATER MAINS SHALL BE MADE BY MEANS OF A TAPPING SLEEVE AND VALVE. ON NEW WATER MAINS, A "TEE" AND GATE VALVE SHALL BE UTILIZED FOR WATER SERVICES GREATER THAN 2 INCHES. b) FOR SERVICES UP TO 2", ALL WATER SERVICE TUBING SHALL BE COPPER. DUCTILE IRON PIPE SHALL BE USED FOR SERVICES LARGER THAN TWO INCHES (2"). POLYETHYLENE OR OTHER PLASTIC SERVICE TUBING WILL NOT BE PERMITTED. c) MULTIPLE METERS MAY BE INSTALLED IN ACCORDANCE WITH THE STANDARD DETAIL. d) FURNISH SAMPLES OF SERVICE ACCESSORIES TO THE TOWN REPRESENTATIVE FOR APPROVAL AND TO DEMONSTRATE COMPLIANCE WITH THESE SPECIFICATIONS. SAMPLES SHALL INCLUDE SADDLES, CORPORATION STOPS, METER SETTERS, METER BOXES, ETC. 2. SERVICE SADDLES SERVICE SADDLES SHALL BE ALL BRONZE WITH DOUBLE BRONZE STRAPS AND WITH A NEOPRENE "O"_RING GASKET ATTACHED TO THE BODY. THE OUTLET SHALL BE AWWA TAPERED THREADS FOR DIRECT CONNECTION TO THE CORPORATION STOP. SERVICE SADDLES SHALL BE MUELLER H-16100 SERIES, FORD STYLE 202-B, OR APPROVED EQUAL. 3. CORPORATION STOPS CORPORATION STOPS SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH AWWA STANDARD C800, LATEST REVISION. CORPORATION STOPS SHALL BE EQUIPPED WITH AN AWWA STANDARD TAPERED THREAD ON THE INLET END AND A COMPRESSION CONNECTOR ON THE OUTLET END FOR CONNECTION OF PLAIN END COPPER TUBING. THE STOPS SHALL BE FULLY SHOP TESTED FOR LEAKS WITH AIR PRESSURE UNDER WATER. THE CORPORATION STOPS SHALL BE MUELLER H15008, MCDONALD 4701T, FORD F-1000 OR APPROVED EQUAL. COPPER TUBING SHALL BE TYPE K SOFT COPPER TUBING CONFORMING TO ASTM STANDARD B88. 5. METER BOXES FOR SERVICES LARGER THAN 1-INCH SHALL BE AS SHOWN ON THE STANDARD DETAIL 6.04 OR 6.05, AS APPLICABLE. A 1" DIAMETER HOLE SHALL BE PROVIDED IN THE COVER FOR INSTALLATION OF A "TOUCH READ" PAD. 6. REDUCED PRESSURE ZONE BACKFLOW PREVENTERS & ENCLOSURES a) REDUCED PRESSURE ZONE BACKFLOW PREVENTERS, WHERE REQUIRED ON IRRIGATION SYSTEM SERVICE CONNECTIONS OR OTHER HIGH HAZARD CONNECTIONS AS DETERMINED BY THE TOWN REPRESENTATIVE OR THE TOWN ENGINEER, SHALL BE ONE OF THE FOLLOWING DEVICES: FEBCO MODEL 825, 825Y OR 845 WATTS MODEL 009 OR 909 WILKINS MODEL 575 OR 575M b) ADDITIONAL DEVICES MAY BE APPROVED UPON REQUEST TO THE TOWN REPRESENTATIVE. c) REDUCED PRESSURE BACKFLOW PREVENTERS SHALL BE INSTALLED ABOVE GROUND IN AN INSULATED ALUMINUM ENCLOSURE. THE ENCLOSURE SHALL HAVE A HINGED ACCESS DOOR AND A REMOVABLE TOP. SCREENED RELIEF PORTS SHALL BE PROVIDED AT EACH END OF THE ENCLOSURE. THE UNIT SHALL HAVE STIFFENING RIBS AND SHALL BE INSULATED WITH 2" OF FIBERGLASS INSULATION ON THE INTERIOR. THE UNIT SHALL BE INSTALLED ON A 4-INCH THICK CONCRETE PAD. THE ENCLOSURE SHALL BE "HOT -BOX" AS MANUFACTURED BY COMMERCIAL INSULATION COMPANY, INC. OF JACKSONVILLE, FLORIDA. SEWER SERVICE LATERAL NOTES: 1. GENERAL FOUR _INCH (4") SERVICE LATERALS MAY BE TAPPED DIRECTLY INTO THE TOP QUARTER OF 8, 10 AND 12-INCH MAINS OR MANHOLES. ALL INDIVIDUALLY OWNED STRUCTURES SHALL REQUIRE AT LEAST ONE SEWER TAP. CLEAN -OUTS FOR SEWER SERVICES SHALL BE LOCATED AT THE EASEMENT OR RIGHT-OF-WAY BOUNDARY, BUT IN NO CASE AT INTERVALS GREATER THAN 75 FEET FOR 4" PIPE. MULTIPLE SERVICE CONNECTIONS ARE TO BE FOR PRIVATE USE ONLY AND WILL NOT BE MAINTAINED BY THE TOWN OF LOUISBURG. A CLEAN -OUT (OR MANHOLE) SHALL BE INSTALLED ON EACH SERVICED LOT'S RIGHT-OF-WAY OR EASEMENT FOR THE TOWN'S USE, AND SHALL EXTEND A MINIMUM OF 6 INCHES ABOVE THE FINISH GRADE. MINIMUM GRADE FOR SERVICE LATERALS SHALL BE 1/4 INCH PER FOOT FOR 4-INCH. 2. SERVICE LATERAL MATERIALS a) GENERAL REQUIREMENTS: ALL SEWER SERVICE LATERALS SHALL BE CONSTRUCTED OF EITHER PVC SCHEDULE 40 OR DUCTILE IRON (AS PREVIOUSLY SPECIFIED). THE USE OF LIGHTWEIGHT CAST IRON SOIL PIPE, PVC (SDR 35) PIPE OR ABS SOLID WALL PIPE (SDR 23.5) SHALL NOT BE PERMITTED. DUCTILE IRON PIPE, AS SPECIFIED HEREINBEFORE, SHALL BE USED FOR SERVICE LATERALS CROSSING BENEATH CREEKS OR DRAINAGEWAYS. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL FURNISH SAMPLES OF SERVICE MATERIAL FITTINGS TO THE TOWN REPRESENTATIVE FOR APPROVAL. SAMPLES SHALL INCLUDE SADDLES, WYES, CLEANOUTS, ADAPTERS, COUPLINGS, ETC. b) PVC SERVICE PIPE & FITTINGS: PVC PIPE AND FITTINGS FOR SEWER LATERALS SHALL CONFORM TO ASTM D2665 "PVC PLASTIC DRAIN, WASTE & VENT PIPING" AND SHALL BE SCHEDULE 40 AND NSF APPROVED. LAYING LENGTHS MAY BE 10 OR 20 FEET. JOINTS SHALL BE OF THE SOLVENT WELD TYPE. ALL CEMENT SHALL HAVE A TRACE COLOR TO ALLOW FOR VISUAL INDICATION OF UNIFORM APPLICATION. 3. PIPE BEDDING REQUIREMENTS - SCHEDULE 40 PVC SERVICE PIPE THE TRENCH BEDDING FOR SCHEDULE 40 PVC SERVICE PIPE SHALL BE CLASS "C", AS DEFINED UNDER SECTION 7.07, I.E., -2" NATIVE, GRANULAR MATERIAL BEDDING. 4. BACKFILLING - SCHEDULE 40 PVC SERVICE PIPE: THE INITIAL BACKFILL FOR THIS PIPE MATERIAL SHALL BE CLASS I SOILS, CLASS II SOILS, CLASS III SOILS OR TYPE ML AND CL SOILS IN THE CLASS IV GROUPING, PLACED IN 6 INCH LAYERS WITH EXTREME CARE TAKEN TO ENSURE THAT THE MATERIAL IN THE "HAUNCHING" ZONE (UP TO THE SPRING -LINE OF THE PIPE) IS CAREFULLY AND PROPERLY PLACED AND COMPACTED AS NECESSARY TO ENSURE THAT THE PIPE IS PROPERLY SUPPORTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THIS INITIAL BACKFILL ZONE SHALL EXTEND TO A POINT 12 INCHES ABOVE THE TOP OF THE PIPE. SEE LAST PARAGRAPH OF THIS SECTION FOR FINAL BACKFILL REQUIREMENTS. LANDSCAPING NOTES 1. ALL NEW PLANTINGS SHALL MEET THE REQUIREMENTS OF THE TOWN OF LOUISBURG. 2. ALL DISTURBED AREAS NOT OCCUPIED BY STRUCTURES, PAVING OR PLANTINGS SHALL BE GRADED AND SEEDED AS INDICATED IN SPECIFICATIONS. 3. ALL TREE PLANTINGS SHALL BE MULCHED WITH 4" CLEAN, PINE STRAW MULCH. 4. ALL PLANT BEDS TO BE EDGED WITH TYPICAL "V-CHANNEL" EDGE. 5. A MINIMUM OF FOUR INDIVIDUAL SOIL SAMPLES SHALL BE TAKEN THROUGHOUT THE SITE FOR OVERALL SOIL ANALYSIS. 6. CONTRACTOR TO UTILIZE ALL ONSITE TOPSOIL. CONTRACTOR SHALL SUPPLY ADDITIONAL TOPSOIL AT NO ADDITIONAL COST TO OWNER IF EXISTING TOPSOIL IS NOT SUFFICIENT TO MEET THE NEEDS OF THIS PROJECT. 7. ALL PLANTING AREAS TO RECEIVE 1 CY OF SOIL CONDITIONER FOR EACH 75 SF OF PLANT BED AREA. ACCEPTABLE SOIL CONDITIONERS SHALL BE PULVERIZED PINE BARK, PEAT MOSS OR SHREDDED/COMPOSTED LEAVES. 8. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING UTILITIES BEFORE BEGINNING OF GRADING AND LANDSCAPE INSTALLATION. 9. CONTRACTOR TO VERIFY QUANTITIES OF PLANTINGS AS SHOWN. PLANTINGS INDICATED ON PLANS SHALL PREVAIL OVER QUANTITIES INDICATED IN PLANT LIST IF DISCREPANCIES ARISE. 10. ALL PLANTS ARE TO BE THOROUGHLY "WATERED IN" THE SAME DAY AS PLANTED. 11. THE PLANT HOLE WIDTH SHALL BE A MINIMUM THREE TIMES THE DIAMETER OF THE ROOT BALL. 12. REMOVE ALL STRAPPING AND TWINE FROM ROOT BALL. REMOVE WIRE BASKET AND BURLAP FROM TOP 1/3 OF ROOT BALL BEFORE BACKFILLING AROUND BALL IS COMPLETED. 13. ALL TREES WHICH ARE SMOOTH BARKED AT THE TIME OF PLANTING AND HAVE MORE THAN 2' OF ALL TREE WRAPPING SHALL EXTEND FROM THE TOP OF THE BACKFILL TO THE LOWERMOST TREE BRANCHES. 14. ALL TREES, WHEN PLANTED, SHALL HAVE THE SAME RELATIONSHIP TO FINISHED GRADE AS TO THE GRADING PLAN. 15. LANDSCAPING SHOWN MEETS QUANTITY REQUIREMENTS. ALL INSTALLATION AND MAINTENANCE SHALL BE PER TOWN OF LOUISBURG. 16. ALL ADDITIONAL LANDSCAPING SHALL BE PER OWNER. 17. ALL TREES SHALL BE LOCATED A MINIMUM OF 15' FROM SITE LIGHTING LUMINAIRES. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ STANDARDS AND SPECIFICATIONS POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 I REVISION HISTORY I REV DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 2 NCDEQ COMMENTS 4/9/2021 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM ORIGINAL PLAN SIZE: 24" X 36" SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1" IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 MOSS RENTALS, LLC DATE: 03-25-2020 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 GENERAL NOTES C�2 SHEET 2 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. STORM DRAINAGE CALCULATIONS STRUCTURE NUMBER Cc I A A Tc Q Q FROM TO NO. OF BOXES RUNOFF COEFFICIENT 10-YEAR INTENSITY (in/hr) DRAINAGE AREA (sf) DRAINAGE AREA (ac) TIME OF CONCENTRATION (min) FLOW (cfs) TOTAL FLOW (cfs) SLOPE (ft/ft) Dtheo (in) SIZE (in) Vfull (ft/sec) PIPE LENGTH (ft)* UPPER INVERT (ft) LOWER INVERT (ft) HOOD/TOP ELEVATION (ft) PIPE MATERIAL CB-1 CB-2 1 0.90 7.22 3700 0.08 5.0 0.55 0.55 0.0058 6.6 12 3.7 86.00 298.35 297.85 303.90 HDPE CB-2 CB-3 1 0.90 7.22 3700 0.08 5.0 0.55 1.10 0.0053 8.7 12 3.6 114.00 297.85 297.25 303.25 HDPE CB-3 CB-4 1 0.90 7.22 10000 0.23 5.0 1.49 2.60 0.0057 11.8 15 4.3 131.00 297.25 296.50 303.35 HDPE CB-5 CB-6 1 0.90 7.22 10100 0.23 5.0 1.51 1.51 0.0050 9.9 12 3.5 111.00 298.30 297.75 302.50 HDPE CB-6 YI-7 1 0.90 7.22 8900 0.20 5.0 1.33 2.83 0.0050 12.5 15 4.0 100.00 297.75 297.25 302.50 HDPE CB-8 YI-7 1 0.90 7.22 7800 0.18 5.0 1.16 1.16 0.0053 8.9 12 3.6 94.00 297.75 297.25 304.00 HDPE YI-7 CB-4 1 0.90 7.22 7800 0.18 5.0 1.16 5.16 0.0061 15.1 18 5.0 123.00 297.25 296.50 303.00 HDPE CB-4 FES-20 j 1 j 0.90 j 7.22 j 13200 j 0.30 j 5.0 1.97 9.73 0.0055 j 19.5 j 24 j 5.8 j 91.00 j 296.50 j 296.00 j 303.25 j HDPE CB-9 YI-11 1 0.90 7.22 11500 0.26 5.0 1.72 1.72 0.0087 9.3 12 4.6 103.00 299.90 299.00 303.40 HDPE CB-10 YI-11 1 0.65 7.22 17800 0.41 5.0 1.92 1.92 0.0110 9.3 12 5.1 109.00 299.00 297.80 303.40 HDPE YI-11 CB-12 1 0.90 7.22 8500 0.20 5.0 1.27 4.90 0.0101 13.5 15 5.7 129.00 297.80 296.50 304.25 HDPE CB-13 CB-16 1 0.65 7.22 15300 0.35 5.0 1.65 1.65 0.0134 8.5 12 5.7 131.00 299.75 298.00 304.00 HDPE CB-16 CB-12 1 0.90 7.22 6800 0.16 5.0 1.01 2.66 0.0110 10.6 15 6.0 136.00 298.00 296.50 304.60 HDPE CB-12 FES-21 1 0.90 7.22 12800 0.29 5.0 1.91 9.47 0.0238 14.7 24 12.0 21.00 296.50 296.00 303.75 HDPE YI-30 YI-31 2 0.90 7.22 58700 1.35 5.0 8.76 8.76 0.0122 16.2 18 7.1 82.00 295.50 294.50 300.00 HDPE YI-31 CB-17 1 0.90 7.22 5000 0.11 5.0 0.75 9.50 0.0104 17.2 18 6.6 144.00 294.50 293.00 298.00 HDPE CB-17 CB-18 1 0.90 7.22 1000 0.02 5.0 0.15 9.65 0.0132 16.5 18 7.4 38.00 293.00 292.50 298.50 HDPE CB-18 FES-19 1 0.90 7.22 1800 0.04 5.0 0.27 9.92 0.0417 13.5 18 13.1 12.00 292.50 292.00 296.50 HDPE *LENGTHS ARE OF THE PIPE ONLY, CENTER OF STRUCTURE TO CENTER OF STRUCTURE, AND DO NOT INCLUDE FLARED END SECTIONS OR OTHER END TREATMENT SWALE DESIGN 10-YEAR RIGHT DRAINAGE DRAINAGE Q LEFT SIDE CHANNEL CHANNEL NORMAL SHEAR SWALE RUNOFF RAINFALL UPPER LOWER LENGTH CHANNEL BOTTOM WIDTH SIDE FREEBOARD VELOCITY MANNING'S TEMPORARY AREA AREA TOTAL SLOPE, DEPTH SLOPE DEPTH STRESS PERMANENT LINER*** NUMBER COEFFICIENT INTENSITY INVERT INVERT (ft) SECTION (ft) SLOPE, (ft) (fps) n VALUE LINER** (sf) (acres) (cfs) Z:1 (ft) (ft) (ft/ft) (ft) (Ib/ft2) (in/hr) Z:1 (ft) 1A 0.40 7.22 9,600 0.22 0.64 305.00 304.00 150.00 TRIANGULAR - 2.00 2.00 1.00 0.007 0.48 0.52 0.20 1.39 0.030 STRAW CLASS C VEGETATION NETWITH 1 B 0.40 7.22 11,800 0.27 0.78 304.00 300.00 125.00 TRIANGULAR - 2.00 2.00 1.00 0.032 0.38 0.62 0.76 2.70 0.030 STRAW CLASS C VEGETATION NETWITH 2* 0.40 7.22 15,300 0.35 11.38 296.00 295.00 200.00 TRIANGULAR - 2.00 2.00 2.00 0.005 1.47 0.53 0.46 2.63 0.030 STRAW CLASS C VEGETATION NETWITH 3** 0.40 7.22 4,200 0.10 10.20 293.00 292.00 20.00 TRIANGULAR - 2.50 2.50 1.50 0.050 0.92 0.58 2.87 6.03 0.030 NAG SC250 CLASS C VEGETATION WITH NAG SC250 *INCLUDES 10-YEAR STORM DISCHARGE FROM STORMWATER WETLAND **INCLUDES 10-YEAR DISCHARGE FROM FES-19 ***APPROVED EQUALS ACCEPTED SKIMMER SEDIMENT BASIN DESIGN CALCULATIONS SKIMMER SEDIMENT BASIN DESIGN SKIMMER SEDIMENT BASIN EFFICIENCY SKIMMER** DRAINAGE DISTURBED REQUIRED VOLUME WEIGHTED 10-YEAR REQUIRED AREA ORIFICE ORIFICE BASIN AREA AREA VOLUME DEPTH* WIDTH LENGTH PROVIDED RUNOFF RAINFALL FLOW Q SURFACE AREA PROVIDED SIZE RADIUS DIAMETER NUMBER (ac) (ac) 1800 CF/AC (ft) (ft) (ft) (cf) COEFFICIENT INTENSITY (cfs) 325 SF/CFS (sf) (In) (in) (in) (cf) (in/hr) (sf) SK-1 3.16 3.16 5,688 4.5 - - 36,509 0.5 7.22 11.41 3,707 10,841 2.0 0.7 1.5 SK-2 1.10 1.10 1,980 2 26 52 2,704 0.5 7.22 3.97 1,291 1,352 1.5 0.5 0.9 *DEPTH FROM BOTTOM OF SKIMMER BASIN TO SPILLWAY ELEVATION **SKIMMER SIZED PER SIZING CALCULATOR AT WWW.FAIRCLOTHSKIMMER.COM USING REQUIRED VOLUME AT A DRAWDOWN RATE OF 72 HOURS SKIMMER BASIN SPILLWAY DESIGN RIGHTCHANNEL BOTTOM LEFT SIDE CHANNEL NORMAL SHEAR BASIN Q UPPER LOWER LENGTH CHANNEL SIDE FREEBOARD VELOCITY MANNING'S WIDTH SLOPE, DEPTH SLOPE DEPTH STRESS LINER NUMBER (cfs) INVERT INVERT (ft) SECTION (ft) Z:1 (ft) SLOPE, (ft) (ft/ft) (ft) (ft) (Ib/ft2) (fps) n VALUE Z:1 (ft) SK-1 11.41 300.50 300.00 46.00 TRAPEZOIDAL 20.00 3.00 3.00 1.50 0.011 0.27 1.23 0.18 2.03 0.030 NAG SC250 SK-2 3.97 296.00 295.00 42.00 TRAPEZOIDAL 10.00 2.00 2.00 1.00 0.024 0.17 0.83 0.25 2.26 0.030 NAG SC250 TEMPORARY DIVERSION DITCH DESIGN 10-YEAR DRAINAGE BOTTOM LEFT SIDE RIGHT SIDE CHANNEL CHANNEL NORMAL SHEAR DITCH RUNOFF RAINFALL AREA Q LENGTH CHANNEL WIDTH SLOPE, Z:1 SLOPE, Z:1 DEPTH SLOPE DEPTH FREEBOARD STRESS VELOCITY MANNING'S n TEMPORARY NUMBER COEFFICIENT INTENSITY (acres) (cfs) (ft) SECTION (ft) (ft) (ft) (ft) (ft/ft) (ft) (ft) (Ib/ft2) (fps) VALUE LINER (in/hr) STRAW WITH TD-1 0.50 7.22 0.30 1.08 88.00 TRIANGULAR - 2.00 2.00 1.00 0.023 0.48 0.52 0.69 2.34 0.033 NET STRAW WITH TD-2 0.50 7.22 0.28 1.01 84.00 TRIANGULAR - 2.00 2.00 1.50 0.012 0.53 0.97 0.40 1.80 0.033 NET STRAW WITH TD-3 0.50 7.22 0.62 2.24 293.00 TRIANGULAR - 2.00 2.00 1.50 0.017 0.66 0.84 0.70 2.57 0.033 NET STRAW WITH TD-4 0.50 7.22 0.22 0.79 174.00 TRIANGULAR - 2.00 2.00 1.50 0.011 0.49 1.01 0.34 1.65 0.033 NET CALL 48 HOURS BEFORE YOU DIG BOUYANCY CALCULATIONS SCM RISER TOP OF OUTLET STRUCTURE = 299.50 ft BOTTOM = 296.00 ft HEIGHT OF RISER = 3.50 ft ASSUME 6" WALL THICKNESS WEIGHT CALCULATIONS Vbase= O'x0'x0'= 0.00 cf Wbase = 0 cf x 150 lb/cf = 0.00 Ibs Vsump= 4'x4'x2'= 32.00 cf Wsump = 32 cf x 150 lb/cf = 4800.00 Ibs Wstruc = [(5 x 5 x 3.5)-(4 x 4 x 3)] x 150 lb/cf = 5925.00 Ibs TOTAL WEIGHT = 10725.00 Ibs BOUYANCY CALCULATIONS Bbase = 0 cf x 62.4 lb/cf = 0.00 Ibs Bstruc = (5 x 5 x 3.5) x 62.4 Ib/cf 5460.00 Ibs TOTAL BOUYANCY = 5460.00 Ibs FACTOR OF SAFETY = 1.96 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ STANDARDS AND SPECIFICATIONS POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 h 'Q° S4C)' • �� SSE W 033 7 D.�FP� REVISION HISTORY REV DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 2 NCDEQ COMMENTS 1 4/9/2021 1 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM ORIGINAL PLAN SIZE: 24" X 36" SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1" IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 MOSS RENTALS, LLC I DATE: 1 03-25-2020 1 I SCALE: I AS SHOWN I DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 CALCULATIONS C-3 SHEET 3 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. NOTES 1. BOUNDARY AND TOPOGRAPHIC SURVEY DATA PROVIDED BY CAWTHORNE, MOSS & PANCIERA, PC. 2. THE SITE WAS INVESTIGATED FOR THE PRESENCE OF JURISDICTIONAL WETLANDS AND STREAMS BY CAROLINA ECOSYSTEMS, INC. NO JURISDICTIONAL FEATURES ARE PRESENT ONSITE. 6. THE CONTRACTOR SHALL VERIFY DEPTHS AND LOCATIONS OF ALL UTILITIES PRIOR TO BEGINNING WORK AND SHALL USE CARE WHEN OPERATING AROUND EXISTING UTILITIES. 7. THE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR THE REPAIR OF ANY EXISTING UTILITIES DAMAGED DURING OWNER: SCHAAF ROBERT CONSTRUCTION. EDMUND EX. LOUISBURG BIKE TRA" PIN. 2805-21-2007 3. THERE ARE NO FLOOD PRONE AREAS PRESENT PER FEMA FIRM _ PANEL NO. 3720280500K, EFFECTIVE APRIL 16, 2003. 4. THE UTILITIES SHOWN ARE NOT GUARANTEED TO BE A REPRESENTATION OF ALL UTILITIES WITHIN THE PROJECT EXTENT. _ 5. THE CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL -CENTER AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. — _- � -\s- / —11 LD Lo 6/1 - 0. 15A 1 'N' EX. POND „ o O OWNER: JEFFREYS os„ PINENTALS LLC 2805 10 9548 EX. DWELLING AND - EX. DRIVEWAY PIPE DRIVEWAY (TO BE REMOVED) (TO BE REMOVED) „ „ �B 0 19 �0. . t Qs o EX. SIGN (TYP.); TO BE RELOCATED WITHIN LIMITS OF ROAD WIDENING (TYP.) EX. TELEPHONE 70 BOX (TYP.) L0 / APPROX. LOCATION EX. 12" WATERLINE, MATERIAL AND DEPTH UNKNOWN EX. SANITARY SEWER 305 / MANHOLE (TYP.) / _ 7 37 D 550 680 / S L = 6 5 2.4 3 9 , R-67 ss rV NC EH�/Y_ AR/ 56 , s � '�B� IAI LEGEND POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 I REVISION HISTORY I REV DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 2 NCDEQ COMMENTS 4/9/2021 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM ORIGINAL PLAN SIZE: 24" X 36" 30 15 0 30 SCALE: 1 INCH = 30 FEET N SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1" I I IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 EX. PROPERTY LINE EX. SUBDIVISION LINE MOSS RENTALS, LLC — — EX. RIGHT-OF-WAY — — EX. ADJACENT OWNERS 300 EX. MAJOR CONTOUR (5) DATE: 03-25-2020 EX. MINOR CONTOUR (1) SCALE: AS SHOWN OHW OHW EX. OVERHEAD ELECTRIC LINE DESIGNED BY: FLM W W EX. WATER LINE APPROVED BY: FLM SS SS EX. SANITARY SEWER PROJECT NO.: 19060 SD SD EX. STORM SEWER EX. TREE LINE LD LD PROP. LIMIT OF DISTURBANCE EXISTING CONDITIONS & DEMOLITION PLAN ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ C�4 STANDARDS AND SPECIFICATIONS SHEET 4 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. NOTES 1. PROPOSED ADA STALL AND AISLE SHALL HAVE SLOPES NO STEEPER THAN 1:48 (2%) IN ALL DIRECTIONS. 2. PROPOSED ACCESSIBLE ROUTES SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:20 (5%) AND CROSS SLOPES NO STEEPER THAN 1:48 (2%). RAMP RUNS SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:12 (8.33%) AND CROSS SLOPES NO STEEPER THAN 1:48 (2%). OWNER: SCHAAF ROBERT EDMUND PIN: 2805-21-2007 3. DIMENSIONS SHOWN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. — 4. RADII ARE F UNLESS OTHERWISE NOTED. — EX. LOUISBURG BIKE TRA" EX. 80' TOWN OF LOUISBURG BIKE TRAIL R/W 5. STRIPING FOR PARKING STALLS AND CROSSWALK SHALL BE AS SHOWN. _ _ PROP. TEMPORARY PROP. 10' X 70' SIGHT CONSTRUCTION ESMT. TRIANGLE (TYP.) PROP. 13' X 24' DUMPSTER ENCLOSURE ON 19' X 22' CONCRETE PAD, 6"-THICK WITH NO. 4 REBAR / 12" O.C. E.W. CENTERED IN SLAB; CONSTRUCT FOOTINGS UNDER ENCLOSURE WALLS TO PROP. 5' CROSSWALK R32' PREVENT FROST HEAVE; ENCLOSURE SHALL BE CMU OR BRICK TO MATCH BUILDINGS R56' /R7.5' __ \ — — 2� REAR SETBACK / OWNER: JEFFREYS RENTALS LLC PIN: 2805-10-9548 PROP. 24" CURB & _ GUTTER (TYP.) r PROP. TURN -DOWN SIDEWALK ADJACENT TO PARKING STALLS (TYP.) / PROP. OPEN PAVEMENT I FOR FUTURE CONNECTION I I PROP. TEMPORARY I CONSTRUCTION ESMT. I I I I I I I I I I I I I I / / CALL 48 HOURS B�FORE YOU DIG I PROP. VARIABLE WIDTH I SCM ACCESS AND / I MAINTENANCE ESMT. I / O Q / O 10 w I PROP. ' PROP. 4'-TALL STORMWATER I CONTROL / CHAIN LINK FENCE R10' p I MEASURE U) PROP. 10'-WIDE I / D I / I / R10' / I I I I I PROP. TYPE 1 DIRECTIONAL ---------- --- I' I R30' R10' R2' 20' (TYP.) 10' (TYP.) I I ► _' / R10' / PROP. 5' CROSSWALK (TYP.) / 0 / 10, 120' PROP. 8,400 SF BLDG. PROP. STANDARD ADA RAMP (TYP.) Eno MIN. 24' (TYP.) 1 NI 10, R10' JP. SPEED / BUMP / 10' / loe 100, le loe / // / 100, R370' / i / i i PROP. SIGN i PROP. TYPE 1 DIRECTIONAL CURB RAMP I CURB RAMP _ F STREET YARD (FOR GRASS AND PLANTS I — AND SHALL NOT BE USED FOR ANY PURPOSE L — — — — — — — — — — — — — — — — — — — PROP. SPEED BUMP EXCEPT NECESSARY DRIVES AND WALKS) PROP. PUBLIC 30' FRONT SETBACK SIDEWALK ESMT. PROP. 5' X F LANDING — — — — — — — — — — — — — — PROP. RIGHT -TURN LANE; SEE SHEET C-12 PROP. ADA RAMP RUN WITH ADA COMPLIANT HANDRAIL EACH SIDE (Vq/?j �C'��Y 56 BCE �'�TH R, vvJ PROP. F CONCRETE SIDEWALK (1' FROM R/W) R10' PROP. TYPE 1 DIRECTIONAL CURB RAMP PROP. ADA RAMP RUN WITH ADA COMPLIANT 1ANDRAIL EACH SIDE PROP. TYPE 1 DIRECTIONAL CURB RAMPS PROP. LEFT -TURN LANE; SEE SHEET C-12 PROP. RETAINING WALL (DESIGN BY OTHERS) WITH GUARDRAIL SUMMARY INFORMATION DEVELOPMENT NAME: MOSS BUILDINGS SITE ADDRESS: 1075 S MAIN ST, LOUISBURG, NC PIN NUMBER(S): 2805-20-2404, 2805-20-3496, AND 2805-20-6521 TOTAL ACREAGE: 4.64 AC EXISTING USE: VACANT PROPOSED USE: RETAIL JURISDICTION: TOWN OF LOUISBURG CURRENT ZONING DISTRICT: B-2 PROPOSED BUILDING AREA: 22,200 SF SETBACKS: FRONT: 30' SIDE: 15' REAR: 20' PARKING CALCULATIONS: PARKING REQUIRED: 1 SPACE PER 300 SF = 22,200 SF / 300 SF = 74 SPACES PARKING PROVIDED: 166 SPACES (6 ADA, VAN ACCESSIBLE) WATERSHED: TAR-PAMLICO EXISTING IMPERVIOUS AREA: 30,772 SF (0.71 AC) OR 15.3% PROPOSED IMPERVIOUS AREA: 116,937 SF (2.68 AC) OR 57.8% LEGEND EX. PROPERTY LINE EX. SUBDIVISION LINE EX. RIGHT-OF-WAY EX. ADJACENT OWNERS PROP. SETBACK LINE PROP. EASEMENT/BUFFER PROP. CHAINLINK FENCE PROP. RETAINING WALL GUARDRAIL ° PROP. ADA HANDRAIL PROP.CONCRETE PROP. LIMITS OF NEW PAVEMENT WITH R/W ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ STANDARDS AND SPECIFICATIONS POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 CAfj Q5 E 033 7 ��.N D.•FP� REVISION HISTORY REV # DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 2 NCDEQ COMMENTS 4/9/2021 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM ORIGINAL PLAN SIZE: 24" X 36" 30 15 0 30 SCALE: 1 INCH = 30 FEET N SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1" I I IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 MOSS RENTALS, LLC DATE: 03-25-2020 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 SITE PLAN C�5 SHEET 5 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. NOTES 1. PROPOSED CONTOURS REPRESENT FINISH GRADES. 2. SLOPES ARE 2H:1 V UNLESS OTHERWISE NOTED. EX. LOUISBURG BIKE T 3. PROPOSED ADA STALL AND AISLE SHALL HAVE SLOPES NO STEEPER THAN 1:48 (2%) IN ALL DIRECTIONS. OWNER: SCHAAF ROBERT EDMUND 4. PROPOSED ACCESSIBLE ROUTES SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:20 (5%) AND CROSS PIN: 2805-21-2007 SLOPES NO STEEPER THAN 1:48 (2%). RAMP RUNS SHALL HAVE RUNNING SLOPES NO STEEPER THAN 1:12 (8.33%) AND CROSS SLOPES NO STEEPER THAN 1:48 (2%). - 5. ROOF DRAIN CONNECTIONS SHALL BE COORDINATEDWITH ARCHITECTURAL PLANS. CONNECT ROOF DRAINS TO STORM DRAIN LINES USING ELBOW AND WYE FITTINGS, INSERTA TEE CONNECTIONS, OR SIMILAR. - - PROP. TEMPORARY 6. ALL HDPE PIPE SHALL BE DOUBLE WALL. CONSTRUCTION ESMT. 7. ALL HDPE PIPE AND ROOF DRAIN CONNECTIONS SHALL MEET NC PLUMBING CODE CHAPTER 11 STORM - - DRAINAGE, LATEST EDITION. - - EX. POND TO BE FILLED IN SWALE 2/: / TO CREATE PROP. SCM - EMBANKMENT AS SHOWN - TC 304.50' BC 304 300 - E - �-tB REAR S_ TBA= 03 _ TC 303.35' / " - PROP. VARIABLE WIDTH BC 302.85' - SCM ACCESS AND / h MAINTENANCE ESMT. ✓�,/ �� .50' 300 TC 304/ 300 PROP. DUMPSTER BC 304.00' I ENCLOSURE / l 1, O U PROP. / O 9 m STORMWATER �w CONTROL FES-20 / RA IL--------------- --, EX. STORM SEWER (TYP.) EX. 80' TOWN OF LOUISBURG BIKE ' TRAIL R/W SWALE 3 295 - �^ 1�-=TC 303.25' BC 302.75' / FES-19 295 295 TC 304.50' CB-2 BC 304.00'zoo-ool / TC 303.90' � CB-17 BC 303.40� v / TC 305.90' BC 305.40' " TC 304.50 " BC 304.00 1105 O ' TC 305. , .90' TC 305.85' TC 304.50' TC 304.00' TArx W 304.00' BC 305.35' BC 304.00" -BC 304_00'. / BW 304.00' � BC 305.40 ����"° � TC 303.60' TW 303.00, / PROP. 8,400 " SF BC 303.10' ,BW296.00' BLDG. " � FFE = 306.00' " / SWALE 1 B w MEASURE / TW 299.00' / PROP. RETAINING WALL � TC 303.25' �h V�k / CB-5 l / (DESIGN BY OTHERS) TC 305.90' N BC 302.75 / WITH GUARDRAIL "mm'^ TC 305.90' � p� / ,. BC 305.40' / / ®�305.00' 305.05' / '�' / / % `?o M� / TC 302.50 / OWNER: RENTALSFLLCYS ' � �^' CB-4 / s � ABC )02 00 / ��..�....�, ' "'" ' ' BC 304.25' "/ 305 30p FES-21 TC 304.75 TC 303.75 / PIN: 2805-10-9548 / BC 303.25' TC 303.60' / / 304. TC 305.85' BC 303.10' / 1 BC 305.35' / 303.18' / OOq PROP. 24" CURB & GUTTER (TYP.) YI-7 300.90' � / 305 TC 305.90' / TC 304.60' BC 305.40' / BC 304.10' TC 305.90' 305.35' BC 305.40" 30 CB-6 TC 302.50 / �•.� � PROP. 5,400 SF S � / BLDG. TC 305.85' YI 30 CB-16 � TC 305.90 X �, W �304.90' BC 302.0 PROP. TURN -DOWN FFE = 306.00 BC 305.35 M / SIDEWALK ADJACENT TO 3�5.�BC 305.40'.� TC 305.90' �� D PARKING STALLS (TYP.) BC 305.40' / Ao _ TC 305.50' / � TC 305.90' `� BC 305.40' PROP. 8,400 SF BC 305.00' �� � - c� BLDG. = TC 305.90' FFE 306.00' ' 305.05' TC 303.60' / TC 305.85 BC 305.40' A� CB-8 BC 303.10' O> Os BC 305.35' YI-11 0 SWALE 1A �� / 304.25' �oM TC 303.00' / / 3p5 BC 302.50" ; oh TC 304.80 � /loe/ PROP. TEMPORARY, "� BC 304.30' // / �� ��LEGEND TC 305.85 / N ESMT. BC 305.35' CONSTRUCTIO � 1105 � I EX. PROPERTY LINE 305.40 ' / 10, / / VC� _A� EX. SUBDIVISION LINE g 304 EX. RIGHT-OF-WAY 305.05 TC 305.50' TC 305.85' aTC BC 303.40' `U' / Gj� - - EX. ADJACENT OWNERS BC 305.00 �p _..-310 -- B_„ 305.35 W W EX. WATER LINE EX. TELEPHONE 3 TC 303.40 i �� / ( ) BC 302.90 SS SS EX. SANITARY SEWER BOX TYP. CB-13 1 GCB-9 i / Qh : TC 304.90' 1304 304.75' / Gj �Qh SD SD EX. STORM SEWER BC 304.40 TC 304.00' CD/ / 300 EX. MAJOR CONTOUR (5') = CB-10 30 "' BC 303.50' � � � 5 � � ,"' EX. MINOR CONTOUR (1') TC 304.90 - - - - - - - - - - - PROP. SETBACK LINE M BC 304.40 3' TC 304.90' / ------- 310 - BC 304.40' PROP. EASEMENT/BUFFER _04.50 -- �� "'�°-- 30' RONT SET ACK � 01 ' / � � mm �.....� PROP. CHAINLINK FENCE APPROX. LOCATION EX. 12" PROP. RETAINING WALL GUARDRAIL WATER LINE, MATERIAL "0 PROP. ADA HANDRAIL w AND DEPTH UNKNOWN W "" ------------ PROP. CONCRETE EX. SANITARY SEWER o MANHOLE (TYP.) w Q, PROP. LIMITS OF NEW PAVEMENT WITH R/VV w APPROX. LOCATION EX. 16"� _ °°°° °. PROP. WATER LINE W � WATER LINE; MATERIAL " AND DEPTH UNKNOWN ss ss PROP. SANITARY SEWER _ PROP. PUBLIC _ � --�. � !rF _ SIDEWALK ESMT. 9 PROP. STORM SEWER S >- PROP. SWALE 300 PROP. MAJOR CONTOUR (5) (V,q NC /�/►An �5 PROP. MINOR CONTOUR (1') I' LE PROP. CATCH BASIN (CB) CALL 48 .HOURS B FORE _ /y`! _.. �.��. � �/pTH ������ �� � � .. .....�. ....mm �,� �"�VI/J .� PROP. YARD INLET (YI) YOU DIG _ PROP. FLARED END SECTION (FES) EX. 8" SANITARY SEWER � LD LD PROP. LIMIT OF DISTURBANCE LINE; MATERIAL UNKNOWN S _- ALL CONSTRUCTION SHALL BE IN NORTH CAROLIN/� ---- SS ACCORDANCE WITH ALL APPLICABLE TOWN ONE -CALL CENTER SS OF LOUISBURG, NCDOT, AND NCDEQ ss STANDARDS AND SPECIFICATIONS 1-800-632-4949 - _---�.�....- ���--~' POST OFFICE BOX 91727 RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 FIRM NC LICENSE NUMBER C-4222 hhyC7��F 5Slp0��i/ QS E - 033 7 AN REVISION HISTORY REV DESCRIPTION DATE BY 1 NCDEQ COMMENTS 12/16/2020 FLM 2 NCDEQ COMMENTS 4/9/2021 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM ORIGINAL PLAN SIZE: 24" X 36" 30 15 0 30 SCALE: 1 INCH = 30 FEET N SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1i' IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 MOSS RENTALS, LLC DATE: 03-25-2020 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 GRADING & DRAINAGE PLAN C�7 SHEET 7 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. NOTES 1. THE WETLAND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION. CONSTRUCTION SHALL BE SEQUENCED SO THAT VEGETATION CAN BE PLANTED AND THE WETLAND BROUGHT ONLINE WITHIN 14 DAYS. PLANTS MAY NEED TO BE WATERED DURING THIS TIME IF THE DEVICE IS NOT BROUGHT ONLINE THE SAME DAY. STABILIZATION MAY BE IN THE FORM OF FINAL VEGETATION PLANTINGS OR A TEMPORARY MEANS UNTIL THE VEGETATION BECOMES ESTABLISHED. IF USING A TEMPORARY MEANS, CONTRACTOR SHALL PROVIDE A WET HYDROSEED MIX. CONTRACTOR SHALL SCARIFY THE SOIL TO A HALF -INCH PRIOR TO HYDROSEEDING. 2. INLET AND OUTLET CHANNELS SHALL BE PROTECTED FROM SCOUR THAT MAY OCCUR DURING PERIODS OF HIGH FLOW. STANDARD EROSION CONTROL MEASURES SHOULD BE USED. 3. THE STORMWATER WETLAND SHOULD BE STAKED AT THE ONSET OF THE PLANTING SEASON. WATER DEPTHS IN THE WETLAND SHOULD BE MEASURED TO CONFIRM THE ORIGINAL PLANTING ZONES. AT THIS TIME, IT MAY BE NECESSARY TO MODIFY THE PLANTING PLAN TO REFLECT ALTERED DEPTHS OR THE AVAILABILITY OF WETLAND PLANT STOCK. CONTRACTOR SHALL COORDINATE PLANTINGS, PLANTING ZONES AND WATER DEPTHS WITH THE ENGINEER. SURVEYED PLANTING ZONES SHOULD BE MARKED ON AN "AS -BUILT" OR RECORD DESIGN PLAN AND LOCATED IN THE FIELD USING STAKES OR FLAGS. 4. THE WETLAND DRAIN SHOULD BE FULLY OPENED FOR NO MORE THAN 3 DAYS PRIOR TO THE PLANTING DATE (WHICH SHOULD COINCIDE WITH THE DELIVERY DATE FOR THE WETLAND PLANT STOCK) TO PRESERVE SOIL MOISTURE AND WORKABILITY. 5. NURSERY STOCK SHALL BE TRANSPLANTED FROM LOCAL AQUATIC PLANT NURSERIES. THE OPTIMAL PERIOD FOR TRANSPLANTING EXTENDS FROM EARLY APRIL TO MID-JUNE SO THAT THE WETLAND PLANTS WILL HAVE A FULL GROWING SEASON TO BUILD THE ROOT RESERVES NEEDED TO SURVIVE THE WINTER. HOWEVER, SOME SPECIES MAY BE PLANTED SUCCESSFULLY IN EARLY FALL. CONTRACTOR SHALL CONTACT NURSERY WELL IN ADVANCE OF CONSTRUCTION TO ENSURE THAT THEY WILL HAVE THE DESIRED SPECIES AVAILABLE. 6. POST -NURSERY CARE OF WETLAND PLANTS IS VERY IMPORTANT IN THE INTERVAL BETWEEN DELIVERY OF THE PLANTS AND THEIR SUBSEQUENT INSTALLATION BECAUSE THEY ARE PRONE TO DESICCATION. STOCK SHOULD BE FREQUENTLY WATERED AND SHADED. 7. SHWT TO BE EVALUATED PRIOR TO CONSTRUCTION. IF SHWT IS WITHIN 6" OF PPE ELEVATION, A CLAY LINER WILL NOT BE REQUIRED. OTHERWISE, INSTALLATION OF A 6" CLAY LINER WILL BE REQUIRED. CLAY LINER SHALL HAVE A MINIMUM 15% PASSING THE #200 SIEVE AND A MAX PERMEABILITY OF 1 X 10-5 CM/SEC. ACCEPTABLE ALTERNATIVES INCLUDE A 30 MIL POLY -LINER OR A BENTONITE LINER. 8. GRADES SHOWN REPRESENT FINISH GRADE ELEVATIONS. TO ACHIEVE FINISH GRADE ELEVATIONS, INSTALL 4" OF TOPSOIL. SOIL pH, COMPACTION AND OTHER ATTRIBUTES OF THE FIRST 12-INCH DEPTH OF THE SOIL SHALL BE ANALYZED BY A SOIL SCIENTIST AND/OR LANDSCAPE ARCHITECT DURING CONSTRUCTION. AMENDMENTS SHALL BE MADE AS NECESSARY. 9. PROVIDE PLANTS PER TABLE ON THIS SHEET. DAM STRUCTURE AND PERIMETER FILL SLOPES SHALL BE PLANTED WITH NON -CLUMPING TURF GRASS. TREES AND WOODY SHRUBS NOT ALLOWED. 10. CATTAILS SHALL NOT BE PLANTED IN WETLAND. OUTLET STRUCTURE NOTES & SPECIFICATIONS 11. THE MANHOLE OUTLET RISER SHALL BE 4'X4' I.D. MEETING ASTM C-913. THE MANHOLE JOINTS SHALL BE ASTM C-443 RUBBER GASKET JOINTS. MANHOLE JOINTS SHALL BE SECURELY ANCHORED TO PREVENT SEPARATION. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE MANHOLE SECTION ANCHORING SYSTEM. 12. WATERTIGHT SEAL SHALL BE PROVIDED AT RISER/BARREL INTERFACE. PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE SHALL NOT BE USED AS BACKFILL AROUND THE PIPE OR ANTI -SEEP COLLAR. FILL MATERIAL AROUND THE RISER/BARREL STRUCTURE SHALL BE PLACED IN 4" LAYERS AND COMPACTED TO THE SAME DENSITY AS THE ADJACENT EMBANKMENT. 13. OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS V-2" ON CENTER. STEPS SHALL BE IN ACCORDANCE WITH NCDOT STD. 840.66. 14. CONCRETE ANTI -FLOATATION BLOCK SHALL BE PRECAST DURING FABRICATION. IF THE CONCRETE ANTI -FLOATATION BLOCK IS CAST SEPARATE FROM THE MANHOLE ASSEMBLY THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANCHORING THE ANTI -FLOATATION BLOCK TO THE MANHOLE RISER ASSEMBLY. 15. ALL POURED CONCRETE SHALL BE A MINIMUM 3,000 PSI (28 DAY) UNLESS OTHERWISE NOTED. BERM SPECIFICATIONS 1. ALL FILL SOILS FOR BERM SECTION SHALL BE CLEAN, IMPERMEABLE MATERIAL AND COMPACTED TO AT LEAST 98% STANDARD PROCTOR MAXIMUM DRY DENSITY, AT OPTIMUM MOISTURE CONTENT. NO BLASTED MATERIALS SHALL BE USED IN THE EMBANKMENT CONSTRUCTION. SOILS SHALL NOT EXHIBIT SIGNIFICANT SHRINK/SWELL OR DISPERSIVE CHARACTERISTICS. THE ON -SITE GEOTECHNICAL ENGINEER SHALL APPROVE THE SOILS FOR PLACEMENT WITHIN THE BERM SECTION. THE GEOTECHNICAL ENGINEER SHALL ALSO SPECIFY THE METHODS TO BE USED FOR PLACEMENT OF FILL. 2. IN ALL FILL AREAS OF THE BERM, A SOILS COMPACTION TEST SHALL BE CONDUCTED EACH 2,500 SQUARE FEET PER VERTICAL CUT OF FILL. 3. FILL PLACEMENT SHALL NOT EXCEED A MAXIMUM OF 8" LIFTS. EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. 4. NO TREES OF ANY TYPE MAY BE LOCATED ON THE BERM SECTION. 5. SIDE SLOPES SHALL BE LINED WITH NAG S75, OR APPROVED EQUAL. 6. INSTALL ANTI -SEEP COLLAR AT MIDPOINT OF OUTLET PIPE. CONCRETE SHALL BE 3,000 PSI (28 DAYS) AND REINFORCED WITH #4 REBAR 12" O.C. EACH WAY. MINIMUM BEARING CAPACITY BENEATH COLLAR SHALL BE 2,000 PSF. CALL 48 HOURS BEFORE YOU DIG STORMWATER WETLAND MAINTENANCE NOTES 1. THE LANDSCAPE PROFESSIONAL MANAGING THE WETLAND MUST UNDERSTAND THE BIOLOGICAL REQUIREMENTS OF THE PLANTS AND MANAGE WATER LEVELS APPROPRIATELY TO PROVIDE FOR THEIR NEEDS. 2. ALTHOUGH WETLAND PLANTS REQUIRE WATER FOR GROWTH AND REPRODUCTION, THEY CAN BE KILLED BY DROWNING IN EXCESSIVELY DEEP WATER. USUALLY, INITIAL GROWTH IS BEST WITH TRANSPLANTED PLANTS IN WET, WELL -AERATED SOIL. OCCASIONAL INUNDATION FOLLOWED BY EXPOSURE TO AIR OF THE MAJORITY OF THE VEGETATION ENABLES THE PLANTS TO OBTAIN OXYGEN AND GROW OPTIMALLY. CONVERSELY, FREQUENT SOIL SATURATION IS IMPORTANT FOR WETLAND PLANT SURVIVAL. 3. DRAMATIC SHIFTS CAN OCCUR AS PLANT SUCCESSION PROCEEDS. THE PLANT COMMUNITY REFLECTS MANAGEMENT AND CAN INDICATE PROBLEMS OR THE RESULTS OF IMPROVEMENTS. FOR EXAMPLE, A REQUIREMENT OF SUBMERGED AQUATIC PLANTS, SUCH AS PONDWEED (POTAMOGETON SPP.), IS LIGHT PENETRATION INTO THE WATER COLUMN. THE DISAPPEARANCE OF THESE PLANTS MAY INDICATE INADEQUATE WATER CLARITY. THE APPEARANCE OF INVASIVE SPECIES OR DEVELOPMENT OF A MONOCULTURE IS ALSO A SIGN OF A PROBLEM WITH THE AQUATIC/SOIL/VEGETATIVE REQUIREMENTS. FOR INSTANCE, MANY INVASIVE SPECIES CAN QUICKLY SPREAD AND TAKE OVER A WETLAND. IF CATTAILS BECOME INVASIVE, THEY CAN BE REMOVED BY A LICENSED AQUATIC PESTICIDE APPLICATOR BY WIPING AQUATIC GLYPHOSATE, A SYSTEMIC HERBICIDE, ON THE CATTAILS. 4. UNLIKE MAINTENANCE REQUIREMENTS FOR WET OR DRY STORMWATER PONDS, SEDIMENT SHOULD ONLY BE SELECTIVELY REMOVED FROM STORMWATER WETLANDS, PRIMARILY FROM THE FOREBAY.SEDIMENT REMOVAL DISTURBS STABLE VEGETATION COVER AND DISRUPTS FLOWPATHS THROUGH THE WETLAND. THE TOP FEW INCHES OF SEDIMENT SHOULD BE STOCKPILED SO THAT IT CAN BE REPLACED OVER THE SURFACE OF THE WETLAND AFTER THE COMPLETION OF SEDIMENT REMOVAL TO RE-ESTABLISH THE VEGETATIVE COVER USING ITS OWN SEED BANK. ACCUMULATED SEDIMENT SHOULD BE REMOVED FROM AROUND INLET AND OUTLET STRUCTURES. 3•7 LEGEND PROP. 20 LF WEIR AT ELEV. 300.50' LINED WITH NAG SC250 (OR APPROVED EQUAL) SWALE 1 B (OFFSITE BYPASS) EX. PROPERTY LINE EX. SUBDIVISION LINE - - EX. RIGHT-OF-WAY - - EX. ADJACENT OWNERS W W EX. WATER LINE SS SS EX. SANITARY SEWER SD SD EX. STORM SEWER 300 EX. MAJOR CONTOUR (5) EX. MINOR CONTOUR (1') - - - - - - - - - - - PROP. SETBACK LINE - - - - - - - - - - - PROP. EASEMENT/BUFFER PROP. CHAINLINK FENCE PROP. STORM SEWER - - • • - - PROP. SWALE 300 PROP. MAJOR CONTOUR (5') PROP. MINOR CONTOUR (1') ® PROP. CATCH BASIN (CB) PROP. YARD INLET (YI) PROP. FLARED END SECTION (FES) LD LD PROP. LIMIT OF DISTURBANCE NORMAL POOL STORMWATER WETLAND PLAN VIEW SCALE: 1 " = 20' 100-YR WSEL ELEV: 300.25' NOTE: SOIL AMENDMENTS, IF PROVIDED, SHALL BE TO A DEPTH OF 12". SEE NOTE #8. PROP. 5' X 5' PRECAST CONCRETE RISER STRUCTURE 4' X 4' GRATE ELEV: 299.50' 1 - 4" DIA. ORIFICE ELEV: 297.25' 1 - 1.5" Q ORIFICE ELEV: 296.00' 24" HDPE INV OUT: 296.00' PROP. 1.50" SCHED 40 PVC W/ 90° TURNDOWN INV 296.00' 2' NON-FOREBAY DEEP POOL 4'X4'X2' CONCRETE SUMP 4' (INTERIOR) 6" #57 STONE BEDDING STORMWATER WETLAND CROSS-SECTION NOT TO SCALE SWALE 2 PROP. RIPRAP ENERGY DISSIPATOR CLASS A RIP RAP 9" THICK POST OFFICE BOX 91727 LENGTH: 8'; WIDTH: 6' RALEIGH, NORTH CAROLINA 27675 PHONE: 919.610.1051 PROP. FES SCM FIRM INC LICENSE NUMBER C-4222 INV. OUT 295.50' / / PROP. VARIABLE 4°`0p`W CA.O����' WIDTH SCM ACCESS & / MAINTENANCE ESMT. z Q5E 033 7 PROP. 4'-TALL CHAIN LINK FENCE / REVISION HISTORY REV / # DESCRIPTION DATE BY PROP. 10'-WIDE 1 NCDEQ COMMENTS 12/16/2020 FLM DOUBLE SWING GATE 2 NCDEQ COMMENTS 4/9/2021 FLM 3 NCDEQ COMMENTS 8/9/2021 FLM 4 NCDEQ COMMENTS 10/7/2021 FLM TOP OF BANK ELEV: 302.00' 8PROP. EMERGENCY SPILLWAY ELEV: 300.50' LINED WITH NAG SC250 - - - - (OR APPROVED EQUAL) ANTI -SEEP COLLAR 50 LF 24" HDPE @ 1.00% INV OUT = 296.00' FES SCM INV = 295.50' STORMWATER WETLAND PLANTING TABLE QUANTITY BOTANICAL NAME COMMON NAME SIZE SPACING SHALLOW WATER PLANTINGS (AREA = 3,134 SQ. FT.; 50 HERBACEOUS PLANTS PER 200 SQ. FT.; 784 TOTAL PLANTS REQ.) 157 ACORUS SUBCORDATUM SWEETFLAG 4 CU. IN. 2' O.C. 157 HYDROLEA QUADRIVALVIS WATERPOD 4 CU. IN. 2' O.C. 157 IRIS VIRGINICA BLUE FLAG IRIS 4 CU. IN. 2' O.C. 157 SAGITTARIA LATIFOLIA DUCK POTATO 4 CU. IN. 2' O.C. 157 SAURURUS CERNUUS LIZARD'S TAIL 4 CU. IN. 2' O.C. SHALLOW LAND PLANTINGS (AREA = 2,114 SQ. FT.; 50 HERBACEOUS PLANTS PER 200 SQ. FT.; 529 TOTAL PLANTS REQ.) 177 CAREX TENERA QUILL SEDGE 4 CU. IN. 2' O.C. 177 HIBISCUS COCCINEUS SCARLET ROSE MALLOW 4 CU. IN. 2' O.C. 177 LOBELIA ELONGATA LONGLEAF LOBELIA 4 CU. IN. 2' O.C. DEEP POOL* 30 ELEOCHARIS ACICULARIS NEEDLE SPIKERUSH BARE ROOT N/A 30 NUPHAR LUTEA SSP. ADVENA YELLOW POND -LILY BARE ROOT N/A *DEEP ZONE PLANTINGS SHOULD NOT BE PLANTED ADJACENT TO THE OUTLET STRUCTURE TO PREVENT CLOGGING ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE TOWN OF LOUISBURG, NCDOT, AND NCDEQ STANDARDS AND SPECIFICATIONS ORIGINAL PLAN SIZE: 24" X 36" 20 10 0 20 SCALE: 1 INCH = 20 FEET N SCALE ADJUSTMENT THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING 0 1" I I IF IT IS NOT 1 INCH ON THIS SHEET, ADJUST YOUR SCALE ACCORDINGLY CONSTRUCTION PLANS MOSS BUILDINGS 1075 S MAIN ST LOUISBURG, NC 27549 MOSS RENTALS, LLC DATE: 03-25-2020 SCALE: AS SHOWN DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 SCM DETAILS C�8 SHEET 8 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. TOP OF FILL TOP OF FILL TOP OF FILL 00 FLEXIBLE PIPE O� H Q H 2" WEEP HOLES GENERAL NOTES: Q UuuN IIII Round Corrugated Steel Pipe Round Corrugated Aluminum Pipe Q �-"S Y-� USE CLASS "B" CONCRETE THROUGHOUT. Q z [C = -;2.: 2 2/3 X %2 corrugation ** 2 2/3 X �/2 COPftigatiOn ** z CC = U PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" Z CL = U GROUND LINE - H GROUND LINE H GROUND LINE N (} N C7 N ('} --I - ----_- ��_ -�- H LL J H Z LL J H Z I ( ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. LL J H Z Diameter Minimum cover Maximum Height Of Cover (feet) Diameter Minimum cover Maximum Height of Cover (feet) 0 0 � = OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT O O z inches (inches Ga 16 14 12 10 8 inCheS 1nChe5 Ga 16 14 12 10 B cc z " 12 CENTERS AS DIRECTED BY THE ENGINEER. = z _ _ _ _ „_,,,_ _ -' - _ _„� _ „_,,,= v = T - _ _'-'® = WQQV-= � � ( ) ( ) WQQW= X x WQQLL= s - _ - H U � O GS 12 12 204 256 12 12 123 155 218 281 344 H' U � O GS � USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. �- U � Q U, COMPACT AFTER - - COMPACT AFTER Q N 15 12 162 204 15 12 98 123 174 224 275 Q H- N IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB ¢ F F-I PLACED _ - - _ _ - PIPE IS PLACED - p W 18 12 135 169 239 18 12 81 102 144 187 228 Cl)1- O W I _ _ _ _ ' AS SHOWN ON STD. N0. 840.00. U 0 W , - _ _ _ _ TO -' _ = - & PRIOR TO Lr- Fy J - - - - �= PLACEMENT OF TYPE 2 PLAC ENT OF O O ¢ 21 12 ENGINEERING 11 5 145 204 2l l2 69 87 123 160 195 O O N ¢ - CONSTRUCT WITH PIPE CROWNS MATCHING. Q GEOTEXTI LE - - cc FI LLEM H H I ES AND GRATES NOT SHOWN Z Cn •°,..;;.•, - _ - - 24 12 76 08 139 171 - - SEE STANDARD D DRAWING 84 .25 FOR ATTACHMENT OF FRAMES . ' Z 24 12 100 126 178 60 1 Z N R 0 E M N TOT MIN. - �> 30 12 79 100 142 27 12 67 95 123 151 �> INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. �-> NOT LESS _- ..,. r CL N 36 12 65 83 117 152 30 12 60 85 111 136 r a ~' INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF N0. 78M STONE IN A W N I.D. /6 MIN. J I.D. /6 MIN. �' Ir®rr,� rr, ®rr,�n r= , =, r'-„' THAN 6" _ _ _ -• r • . rr = EARTH O C] I „_, _ , ,,, ,r,-„I-,,, -r„=n r= ,-,u _rrr , W 42 12 55 70 100 130 160 36 12 50 71 92 113 W POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BV THE ENGINEER. WNOT LESS THAN 6" O.D. + 3' NOT LESSTHAN 6" ?2"PER F00T OF 'H' TOT O O POST OFFICE BOX 91727 BUT NOT LESS THAN t2" 48 12 48 61 87 113 139 42 12 60 78 96 I CHAMFER ALL EXPOSED CORNERS 1". ROCK O.D. + 3' NOR MORE THAN 24" O.D. + 3' 54 12 54 77 100 123 48 12 52 68 84 Y - NORMAL EARTH FOUNDATION ROCK FOUNDATION As DIRECTED BY ENGR. 60 12 69 90 111 54 12 46 50 74 DRAWING NOT TO SCALE. RALEIGH, NORTH CAROLINA 27675 UNSUITABLE MATERIAL FOUNDATION 66 12 81 100 60 12 50 62 PLAN PIPE IN TRENCH 72 12 74 91 66 12 51 WITH GRATE & FRAME REMOVED PHONE: 919.610.1051 TOP OF FILL TOP OF FILL TOP OF FILL 78 12 81 72 12 41 z 64 12 69 Z FIRM NC LICENSE NUMBER C-4222 -- BRICK COPING(INCIDENTAL) �RN FOR DIFFERENT CORRUGATIONS AND ARCH PIPES REFER TO CC O TOP ELEVATION Q H ROADWAY DESIGN MANUAL OR MANUFACTURERS SPECIFICATION. _ MIN. O.D. .D. -- MIN. O.D. MIN. O.D. _ W Q W °�, _ LL W MIN. O.D.- H v --- .-..-. - J J STD. 840.16 FRAME z J REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS Z J � &GRATE z J �IDL GROUND LINE ! GROUND LINE - QQW #4 BARGROUE TYPE 2 LLI CSP - AASHTO M36 N H- OTEXTIL _ - _ a CARP - AASHTO M196 Q N CO 6" 6° a IIIIIIIII GE E � � 6„ A 6„ B H HOPE - _ n _ 0 HOPE - AASHTO M294 < A Z (Minimum fill) 2' for pipe diameters > 12" and < 6 ' COMPACT AFTER' O EL * (Maximum fill) 20' for pipe diameters < 24" O O O _ ♦♦&\'°��*{ C/' RO / C=,,,_,, _,N •. grFm_m�p,.�lp stlr _ _ -,r E.v gv: •. _ _ _rr.... M PVC - ASTM F949 or AASHTO M304 1..1 = I = Q � 11 \4Jl� -" -PIPE Is PLACED 0 17' for pipe diameters >_ 30" and <_ 60" 0 O s COMPACT AFTER I.D./6 MIN. _ - PLACEMEIOINTOBE = - W J W = CC Q p♦ ` ,'®C IVA:•• PIPCL E IS PLACED _ _„_ ,n=,,,_,,, FILL �,,,_,,,_„=n,=_,,,= PVC (Minimum fill 2' for (� 6 �� & PRIOR TO 2' L.D./6 MIN. L,rr=rr,-,rl-,rr-r _ rn=r„=„r Z N m * ) pipe - z N W �, I '---' Z = •,,,.„ "^�°., PLACEMENT of NOT LESS THAN s" O.D.+ 2' I.D./6 MIN. As DIRECTED ¢ X Maximum fill) 30' for T e diameters > 12" and < 36" AASHTO _RFD BRIDGE DESIGN SPECIFICATIONS ¢ _ ¢ F = NOT LEss THAN s" ) pipe diameters 12' and 36' NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING C'3 ¢ L.. FILL NOT LESS THAN 6' MIN. 0.0. MIN. O.D. BV ENGINEER PER FOOT OF 'H' )- d W V MINIMUM COVER FOR ALL SIDE DRAIN PIPE F_ d I- F_ " ",r BUT NOT LESS THAN 12' W J * FILL HEIGHT IS MEASURED FROM THE TOP OF THE PIPE C/) J DOWEL In LU _ M NORMAL EARTH FOUNDATION ROCK FOUNDATION NOR MORE THAN 24" U. LL TO THE BOTTOM OF THE PAVEMENT STRUCTURE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS LL J UNSUITABLE MATERIAL FOUNDATION >- O } O N SEE NOTE DOWEL(SEE NOTE) MAX. PIPE THIS SIDE >- cc N ® _ 33(77�.Z,� PIPE ABOVE GROUND RIGID PIPE LL z GENERAL NOTES: o G 0 C SECTION X-X SECTION Y-Y 0 ~� t '•u° ,qq�� DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS ¢ O RCP - Minimum fill 1 for Class IV & CLASS V ¢ O ¢ i� °.'V(°� pp''G ii I.O. = THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION. BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. O * ( ) O O V q I'y •^;,••° = 2' for Class III & Class II = DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) `+ r/ '(- ♦"` REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS ✓Z P %'• O.D. =THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - SPRINGLINE OF PIPE � ~ DIMENSIONS OF BOX & PIPE CUBIC YARDS DEDUCTIONS FOR '�11 C H THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT SELECT BACKFILL MATERIAL CLASS III OR CLASS II, TYPE I Uj * (Maximum fill) 10' - Class II pipe RCP - AASHTO M170 LU PIPE SPAN WIDTH MIN. HEIGHT CONC. IN BOX ONE PIPE ,/ZI/rrNr ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP ABOVE AND BELOW SPRINGLINE. IG 20' - Class III pipe G BOTTOM WALL PER coNcaETE OF THE EMBANKMENT AT THAT POINT. ® 30' - Class IV pipe D A B H SLAB FT. HT. `,1,_H'MM,,1 C.M. R.C. APPROVED SUITABLE LOCAL MATERIAL, 40' - Class V pipe 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.016 0.026 TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL UNDISTURBED EARTH MATERIAL NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING 15" 2'-3° 0.648 0.023 0.036 (For fills > 40' & < 80' use _RFD Direct design Method) AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 18" 2'-6" 0.703 0.033Mq�2 LOOSELYPLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1 SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE 24" 3'-00.814FOR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE 0.059UNCOMPAISHDAS PIPE COMPACTEOSEATING AND BACKFILL WILL wITH TYPE 2 GEOTExTTLE As DIRECTED ev rHE ENGINEER. SHEET 1 OF 3 *TOLTHEEBOTTOMIGHT SOFETHERPAVEMENTED FROM TSTRUCTURE HE TOP OF THE PIPE 1' MINIMUM COVER FOR ALL SIDE DRAIN PIPE SHEET 3 OF 3 30" 3'-0" 2'-0" 3'-6" 0.222 0.222 0.925 0.092 SHEET 1 OF 1 N. 300.01 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS 300.01 840.14 z GENERAL NOTES: z z REVISION HISTORY O FRAME GRATE AND HOOD Q O U y v r N (n BACK OF CURB SEE 3TD. N0. 84F1I USE CLASS "B" CONCRETE THROUGHOUT. O S N 3'- 6 } N } EXPANSION JOINTS } y „ Q Q X PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" Q Q Q Q < REV ` 2 Q �S 5/g" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. Q 6" E^°j 4'-6" 4`-6" _ 5 1" DEPRESSION -" 5 8 5 F z 3= 0 z x I z U DESCRIPTION DATE BY r r r-r G7 ' 1 /$ "30 - TOP ELEVATION OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT N W Ur U r 1r 7 /8rr it 7 /$rr LJ "�-� O O O.. = Z Y Y 12" CENTERS AS DIRECTED BY THE ENGINEER. LL J O H #4 BARS "V" 6 6 STD. 840.03 FRAME, W -I d ~ Z -► LI ' c o f - _ USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. O O 55= z @ EQUAL SPACES t GRATE &HOOD Q O II z " A cc z -1/2, +� 1i2„ LuQzLL " CC E E W Q Q LL = --- IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB W Q ¢ = 3" I U Q O = 1 NCDEQ COMMENTS 12/16/2020 FLM (� 0 l� G H- U = O ,U c1 AS SHOWN ON STD. N0. 840.00. I- U O , / = CIS N ♦w 0 I F = ~ z �y _--- 6" B 6" s USE TYPE "E' , F' AND 'G' GRATES UNLESS OTHERWISE INDICATED. < = F Z W _ ~ zit ~ Q OW Q FOR 8' 0' IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER LL J _ _ w LC cn O Q 2 NCDEQ COMMENTS 4/9/2021 FLM N Q (n D 8'-0" TO 16' 0" IN HEIGHT USE 8' WALLS AND BOTTOM SLAB. ADJUST O O O Q R w IR = O O CC N 0 ( Z HOC ,..f'.. "..T �o �6,-0., Z r-r -I O r.., QUANTITIES ACCORDINGLY. z H = 1 r PLAN CONSTRUCT WITH PIPE CROWNS MATCHING. IH .N ¢ y PLAN r 3 NCDEQ COMMENTS 8/9/2021 FLM H W x 3" SEE NOTE CHAMFER ALL EXPOSED CORNERS t'. r W 0 L m ¢ LL a� Q r+- CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES r LLJ SECTION G- G _m I r O TOP ELEVATION SECTION x-x DRAWING NOT TO SCALE. T O g EOLEV. T O 1'-a1i2" 1'-ai2" F -F M - m USE ON FLAT EXPANSION JOINT 6" 4 NCDEQ COMMENTS 10/7/2021 FLM PLAN OF FRAME Ln TOP ELEVATION GRADES 2°a AND UNDER 1r 7r'8" it 75//8" r 6, q FRAME GRATE AND H000 STEPS - STD. NO. 840.66 DEPRESSED GUTTER LINE CAST IRON O J SEE STD.NO. 840.03 STEPS - STD. N0. 840.66 S` 3'-0" 13'_0" PLAN OF GRATING N Co - 11 EXPANSION JOINT ELEVATION TOP ELEVATION - - - - - - - - - PLAN OF TOP SLAB SECTION S-S" Ir l ¢ 2' 31/" CAST IRON Ow < z �- ml - o O Z Ow Z L > -A LL NORMAL CURB AND GUTTER ON LIGHT GRADES N °o w' `: E-.-� '. Z m W NORMAL GUTTER LINE H m W 'S .Z Q 6 G 6" ~ a 6" E #8 "W" BARS #4 BAR EXPANSION JOINT Q CL y/8rr 1/srr y/8rr y/sr < e( �t SECTION Y-Y s c s^ B N TOP a 0 W CC) D : 0 0 a #4 BARS "V" " USE ON GRADES OVER 2% ELEV. _ _ _ Ca EQUAL SPACES :.i RISER HT. 0 - - DEPRESSED GUTTER LINE 0 ~ LO 3I3 Q VARIES - = V EXPANSION JOINT MAX. LI IrQ3'-3/4 2 3/4 Q s'-o" Q0y1/ yy 1 rrz LL 0mo v zIL' #4 BARS r,U„1v2,r z LV1 16�2" 0 OC _ - 6 o o„ Uj 8rr /g" /8 /g s' T SECTION J-J ,r:: - � < DOWEL ELEVATION F- I' 3/ ^ 34 ° �, 3/ " 3/ " ( (q Uj .:..+...°.,,r� `p WHERE 30" TO 36" PIPE IS USED I/J W SECTION R-R NORMAL CURB AND GUTTER ON STEEP GRADES SECTION H - H UIJ 3EE NOTE SECTION m-m GC N 3 2 2'- 2 ' } J WHERE 42" TO 54" PIPE IS USED } �- N } Q Z = WHERE 30" TO 36" PIPE IS USED Q �.i r MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN (BASED ON MIN. HEIGHT, H, WITH NO RISER * 9 z r 1,,,1 RISER HT. Z DIMENSIONS OF BOX AND PIPE COVER CU.YDS. CONC. IN BOX DEDUCTIONS 0 QN VARIES _ Q O PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT DIMENSION ggRS-U BARS-V BARS-W TOTAL TOP BOTTOM TOT. COwC, ONE PIPE Q O 21/8rr _ 2y/8" _I O a J p 'r J Q V D A B C G H E N0. LENGTH N0. LENGTH N0. LENGTH LBS. SLAB SLAB HEIGHT, NTNIHU C.M. R.C. O N N N N = O W - _ _ _ 1Cr B m :. > ..,, > .> .'. ti m = 12' 3 p^ 2 2 _ __ 2'.g' __ __ _ __ __ _ __ _ __ __ 0.235 0,772 0.015 0.026 3'-13/4" 2' 13/4 I --_- a' 151,3'-0' 2' 2' 3'-0' 0.235 0.829 0.023 0.036 rj A 18' 3'-0" 2' 2' 3'-3' 0.235 0.887 0.033 0.049 3' 6" 2' 6" LLJI z4" 3'-O" 2' 2"-9"0.235 I.001 0.059 0.085 O o I , m 30' 3' 0" 2'-2 3' 4" 4 3" 1'-2 4 -0" 4 1 -5" 2 3'-9' 3 3'-9 39 0.123 0.321 1.4330.092 0.127 LL - ,, '. 36' 3' o" 2' 2 3 t0" 4' 9" 1' 8' 4 0" 4 1 11" 3 3' 9' 3 3' 9' 43 0.161 0.358 ,.7,4 0.132 0.178SECTION E- E SECTION F-F WHERE 42" TO 54" PIPE IS USED p � c ;;p - 42' 3' O" 2' 2 4'-5' 5 3' ,' S" 3 2" 4 , 8" 2 2' „" 3 2 „'" 32 0.112 0.318 1.738 0.180 0.243 ORIGINAL PLAN SIZE: 24" X 36" °' 48, 3'-0" 2' 2 5'-0' 6 -9' 2 0" 3 -2" 4 2 -3" 3 2'-11" 3 2 -„" 35 0.,45 0.352 2.052 0.235 0.317 DETAIL SHOWING METHOD 54" 3'-0" 2'-2" 5'-7" 6'-3" 2'-7" 3'-2^ 4 2'-10" 5 2'-11" 3 2'-11" 41 0,180 0.386 2_387 0.297 0.401 SHEET 1 OF 1 OF RISER CONSTRUCTION SHEET 1 OF 2 SHEET 2 OF 2 PLAN PLAN RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT 840.02 840.16 840.02 z z 0 2� 23/4r' �>�- 43" NOTE: USE TYPE HE" "F" AND "G" GRATE °� a Q DETAIL SHOWING TYPES OF GRATES 2_yy3/ 2 < Q UNLESS OTHERWISE NOTED. �N� P_ 3�' P z I = U USE ACCORDING TO WATER FLOW. 11/2 H B �_ LL -ION B LL_laP-i n QOrra=Z 0015= W ¢ z LL " TYPE "G" TYPE "E" TYPE "F" q A w Q Q W _ I Qo= = 1 I L9%grr Qo�Oo 21/8rr F-'- 21/8 Q O N N U)F-u 0J InF-�O J o �_ _ SECTION - LL SECTION - MM z O H CC WATER FLOW SAG WATER FLOW 9%8" O H °C , END SECTION DIMENSIONS A - �= A ALIGN FRAME WITH INSIDE y3/8" h H CL or-= EDGE OF WALL TO ALLOW r a --------------------------------- r O-0 DIA. A B C D E LENGTH (La) �= FOR VERTICAL ADJUSTMENT 1„ T M I r p 0 B 1 /2rr r p 15" 7" 2'-3 1 4 3 -11 1 2 6'-2 3 4 2'-6" �O WALL SECTION � � - �� 134 r, 18rr 9rr 2'-3" 3 -11 3 4 6'-2 3 4 3,_0„ o �_ 1 --�- 30" 9rr 3'-srr 30 1 6°-5" 3'-11 3/4" SECTION - BB -}- �.J 1 i2" sis" 30" 1'-0" 4'-6 1 2 1 -10 1 2 6'-5" 5'-0" B SECTION - PP SECTION - NN 36" 1'-4" 5'-0" 3 -1 1 2 8 -1 1 2 5'-11" SECTION B-B ________________________________ 42" 1-10 1 4 5-1 3/8,, 3'-1" 8-2 3 8 6'-51/4" MAINTENANCE: PLAN J \ ;� z 1344" 21/ " cc G H INSPECT PIPE INLET PROTECTION AT FRAME,GRATE, & HOOD ASS'Y = O N WATER FLOW - SAG WATER FLOW �- U) NOTES: I Q O C0 O O Q LEAST WEEKLY AND AFTER EACH LL O Q W O DO 1. DESIGN OF END -SECTION SHALL CONFORM TO / SIGNIFICANT (1/2 INCH OR GREATER) m SECTION A -A _ RAINFALL EVENT TO SEE IF ANY x = STANDARD REINFORCED SECTIONAL m z = r rz-r U CONCRETE CULVERT PIPE. O `� EROSION AROUND OR BELOW THE `w rH O U TYPE "F" TYPE "E" TYPE "G' TYPE - E RIP RAP 3'-0" 13i ° Z Z ¢ 2. ANY TWIN BARREL SYSTEM GREATER THAN 0 = RIPRAP HAS TAKEN PLACE, OR IF THE 4 � Q 9 In Q 42" RCP REQUIRES A HEADWALL. M ~ STONES HAVE BEEN DISLODGED. " 0 0 RAISED FLOW ARROW 0 0 cc K -K v 1314 . 0 Q 1/ HIGH 23/ 3. ANY SYSTEM OF MORE THAN 2 PIPES j IMMEDIATELY MAKE ALL NEEDED SCALE ADJUSTMENT L N m 0 N RAISED FLOW ARROW 23/4" N Q REQUIRES A HEADWALL. DC> REPAIRS TO PREVENT FURTHER SECTION - AA rn o � z %6" HIGH O o F 0 DAMAGE. THIS BAR IS 1 INCH IN LENGTH ¢ 0 O z 4. SEE NCDOT "ROADWAY STANDARD DRAWINGS" N z ¢ FOR HEADWALL CONSTRUCTION DETAILS. Q Q © O O � Q Cc U) ON ORIGINAL DRAWING L M `'I H\� \ c~n `� 1 /2 rr \ 1 y/2,r z 0 1" aJ FRAME PLAN " >- O �\ 1 r `co } - O OHS SECTION - JJ Q W5 /8 a O y/Rr M\ g W W rc PLAN 3/- 1 , 34-�°{ 3 o/s 11 55i$ o O 1 9 y 3/ t 0 0 O ' ON S IF IT IS NOT 1 INCH ON THIS v2 rr Q O P 1 /2 o E 6 G'� R 3" R O W iv, T 11/2"R oc 0 GP f SHEET, ADJUST YOUR SCALE > IF _ cc 0 1 /2 rr 13/ 'L-1 y/g'r W Q R �J OOIL T Env 6" 2'-0" 6" %2" W 2 113/4 T 2'-113/4 �p ON I�(I,E ACCORDINGLY s,r � 1 v2„ r 3a { /2„ 1 "'2 y ,8„ w /2�, RO�� CHO 0 3/2,r 3r_0„ 3/2,r 3/„ 4SA4 - 1j2•• f I I 1 /2 E F� G 1/--err r SECTION - KK �� tis" 13/4 SECTION A -A �H�� /s -►J F CONSTRUCTION PLANS SECTION A -A SHEET 2 OF 2 R O HOOD ELEVATION SECTION - RR $840 �03 TYPE - F F 2TYPE G M 840.113.3 OI � C Ff" � X ' MOSS BUILDINGS �-� 1075 S MAIN ST R31 FILTER BLANKET LOUISBURG, NC 27549 gAPBRc GEMENI' ) SECTION OUTLET Do 3Do La W RIP RAP d 6L FES-19 12" 3' 4' 3' CLASS A R PRAP 9 5 CLASS A 9APFIIGEMENf FES-20 24" 6' 8' 6' R PRAP 9 MOSS RENTALS, LLC FAOOFE RE FES-21 24" 6' 8' 6' CLASS A R PRAP 9 FES-SCM 24" 6' 8' 6' CLASS A 9„ RI PRAP 74 DATE: 03-25-2020 FLARED END SECTION RIPRAP ENERGY DISSIPATOR SCALE: AS SHOWN NO SCALE NO SCALE DESIGNED BY: FLM APPROVED BY: FLM PROJECT NO.: 19060 CALL 48 HOURS BEFORE YOU DIG STORM DRAINAGE DETAILS mb 1s ���nll ALL CONSTRUCTION SHALL BE IN NORTH CAROLINA ACCORDANCE WITH ALL APPLICABLE TOWN ONE -CALL CENTER OF LOUISBURG, NCDOT, AND NCDEQ C�l 6 STANDARDS AND SPECIFICATIONS 1-800-632-4949 SHEET 16 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC. NOTES 1. THIS PLAN IS FOR VERIFICATION OF BUILT UPON AREA (BUA) AND DEPICTION OF THE STORMWATER CONTROL MEASURE (SCM) DRAINAGE AREA ONLY. REFER TO THE REMAINDER OF THE PLAN SET FOR CONSTRUCTION OF THE SITE. o OWNER: SCHAAF ROBERT / EDMUND PIN: 2805-21-2007 ENGINEERING i — EX. 80' TOWN OF — — LOUISBURG BIKE cf) ' / POST OFFICE BOX 91727 TRAIL R/W / / RALEIGH, NORTH CAROLINA 27675 // PHONE:919.610.1051 1� FIRM NC LICENSE NUMBER C-4222 ... , 5 � � — — PROP. POST -DEVELOPMENT � / N / DRAINAGE BOUNDARY TO SCM - ����"�' -- -- .„ / it _ Inn _ 33' ��, "�. . RO�'' w 295w m SE - 0 7 - �� " 'ftiG I N �P '�`4✓ _- o 10 300 _ UB rwrrm" 18� 28 24� 17' 44' or 25' — — / 61 REVISION HISTORY 115 ,� ,, p``� `" � �P„�' / , �A REV 44 DESCRIPTION DATE BY � 41 0 3 _ — — S — m5 - - NCDEQ COMMENTS 12/16/2020 FLM I � 2 NCDEQ COMMENTS 4/9/2021 FLM 120' � - l�, lh' 19 oo 10' 26 3 NCDEQ COMMENTS 8/9/2021 FLM Ifffol° / PROP. 8,400 SF / = r 4 NCDEQ COMMENTS 10/7/2021 FLM J 0' BLDG. 24' FFE = 306.00' 9 PROP. / ili " ; / r `-STORMWATER CONTROL MEASURE 24' �: i�lnullll r J / +�I�i Illlllllll" � '''•s"' p. � �i1111111111114 / AN 26' 6 1 / / o� ell p0 / r154 OWNER: RENTA RENTALS 0C YS / � +m� minim / S 65' // r1197 , ,u��u,�n�miimiY� .. / PIN: 2805-10-9548 m miim m 81 65 / f a amim min mmm� is 6 „ ,mi�imoF 44',mmmm�,... nmmim°ir r 22' am on�nm m _ 61 25' 24, ;:;;,L _ — 305 .mm... ORIGINAL PLAN SIZE: 24" X 36" e — ". -- 31 61 os 90, m / 6' .�� 19' „ ' 30 m o ; mmm � � 52 M 27 25 PROP. 5,400 SF M / 5' BLDG. 10 � � �0 109' 113CD 3os 120 Ip10 `, 26' FFE - 306.00' �m 21 1 g o � 45, 241" / r ' 60, / 70 PROP. 8,400 SF 1000, / c� BLDG. 6 FFE = 306.00' 71' 20' m� m min 305 �" / LEGEND 30 15 0 30 22''01/ SCALE: 1 INCH = 30 FEET E�C�PERT� 19 19, / / L� EX. SUBDIVISION LINE N SCALE ADJUSTMENT a 28 p ' mmm EX. RIGHT-OF-WAY 3 �0 0S _1 / / / THIS BAR IS 1 INCH IN LENGTH 17 78 m 6�100, / �� — — EX. ADJACENT OWNERS ON ORIGINAL DRAWING po i 0 1° -_ 46 15mmm 64 5 304 , // W W EX. WATER LINE 1 I ... -" SS SS EX. SANITARY SEWER IF IT IS NOT 1 INCH ON THIS 18' I --- �V SHEET, ADJUST YOUR SCALE 3 —310~ / SD SD ..� .. min m���> ,,wµ / � � EX STORM SEWER ACCORDINGLY ;. 45' r i \ // �Q' `Q 300 .... EX. MAJOR CONTOUR (5') 84' 4' EX. MINOR CONTOUR (1') � — — — — — — — — — — — PROP. SETBACK LINE CONSTRUCTION PLANS � — — — — — — — — — — — PROP. EASEMENT/BUFFER n27o PROP. CHAINLINK FENCE MOSS BUILDINGS 1075 S MAIN ST 85" / •" ° PROP PJNMRME9�1AALLGUARDRAIL LOUISBURG, NC 27549 PROP. CONCRETE W _ 42' 6 „ — 31 "�" PROP. LIMITS OF W PAVEMENT WITH RANINo - �,� �� w .... PROP. WATER LINE .. _� al MOSS RENTALS, LLC 9 s s°";m PROP. SANITARY SEWER 5 W Z0 uuuuuuuuuuu uuuuuuuuuuuuuui :auuuuuuuuuuuuuui uuuuuuuuuuuuuui :auuuuuuuuuuuuuui : uuuuuuuuuul PROP. STORM SEWER w �0 ;, ............. „ ;,, ;,, . PROP. SWALE 300 PROP. MAJOR CONTOUR (5) DATE: 03-25-2020 SCALE: AS SHOWN SS �- S PROP. MINOR CONTOUR (1') OVA wPROP. CATCH BASIN (CB) DESIGNED BY: FLM S � /�/C ^a °'� APPROVED BY: FLM PROP. YARD INLET (YI) PROP. FLARED END SECTION (FES) PROJECT NO.: 19060 �� Y �� CALL 48 HOURS B FORE �' w�0ry YOU DIG_ SS _ LD LD PROP. LIMIT OF DISTURBANCE PROP. POST DEVELOPMENT BUA VERIFICATION PLAN DRAINAGE BOUNDARY TO SCM i S _— S ALL CONSTRUCTION SHALL BE IN NORTH CAROLINA -- - S ALL WITH ALL APPLICABLE TOWN ONE -CALL CENTER SS OF LOUISBURG, NCDOT, AND NCDEQ C�22 STANDARDS AND SPECIFICATIONS 1-800-632-4949 — ..... SS SHEET 22 OF 22 © 2020 THIS DRAWING SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION OF FLM ENGINEERING, INC.