HomeMy WebLinkAboutNC0027103_Inspection_20110121A'irA NCDENR North Carolina Department of "Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue - Coleen H. Sullins Dee Freeman Governor Director Secretary January 21, 2011 Mr. McDuffie Cummings, Town Manager Town of Pembroke P.O. Box 866 Pembroke, NC 28372 Subject: COMPLIANCE EVALUATION INSPECTION (CEI) Town of Pembroke Wastewater Treatment Plant NPDES Permit No. NC0027103 Robeson County Dear Mr. Cummings: Enclosed you will find a copy of the Compliance Evaluation Inspection (CEI) report for the routine annual inspection that I performed on January 19, 2011 at the Town of Pembroke Wastewater Treatment Plant, accompanied by Rhonda Locklear (ORC, WWTP), Jerry Brooks (Back -Up ORC), and Branyun Bullard (WWTP Operator). - As part of the inspection, a tour. of the Wastewater Treatment Plant was conducted. All observations are in Section D. Summary of Findings/Comments of this inspection report. On the day of my inspection, the wastewater treatment plant appeared to be very well operated and maintained, and it appeared to be in compliance with the NPDES permit. I appreciate the time and professional courtesy that was extended by your staff during the inspection. No additional response is necessary from your office to the DWQ-Fayetteville Regional Office concerning this CEI report. Please contact me at (910) 433-3312 if you have any questions or comments. Sincerely, Dale Lopez Environmental Specialist /dl Enclosures: EPA Water Compliance Inspection Report Facility Site Review (checklist) Regional Field Inspectors Check List for Field Parameters Aerial view of the Town of Pembroke Wastewater Treatment Plant Town of Pembroke Process Flow Diagram cc: Rhonda Locklear, Town of Pembroke, (ORC WWTP) f FRO Files (Mark Brantley)? 225 Green St, Suite 714, Fayette`riille; NC'28301:5043 Phone: 910-433-33001 FAX: 910-486-07071 Customer Service: 1-877-623-6748 One Internet: www.ncwaterquality.org NOrthCarohna An Equal Opportunity l Affirmative Action Employer N a i /Irak United States Environmental Protection Agency Washington, D.C. 20460 EPA Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I NI 2 151 31 NC0027103 111 121 11/01/19 117 Type Inspector Fac Type 18I CI 19I SI 20I II Li 6e 1111 1111 1 1 1 1 111 Remarks 211111 1111111111111111 11111111 1111 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----Reserved--------- 67I 2.0 169 701 4 I 711 I 72I N I 731 1 174 751 1 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Pembroke WWTP NCSR 1339 Pembroke NC 28372 Entry Time/Date 10:45 AM 11/01/19 Permit Effective Date 09/10/01 Exit Time/Date 02:15 PM 11/01/19 Permit Expiration Date 14/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Rhonda Hagan Locklear/ORC/910-521-2989/ Other Facility Data Name, Address of Responsible OfficiaUTitle/Phone and Fax Number McDuffiue Cummings,PO Box 866 Pembroke NC Contacted 283720866//910-521-9758/9105210472 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement • Operations & Maintenance Records/Reports Self -Monitoring Program • Sludge Handling Disposal • Facility Site Review • Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and ature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date I Dale Lopez FRO WQ//910-433-3300 Ext.712/ 1 RIbit r Signature of Management''Q A eviewer Agency/Office/Phone and Fax Numbers Date ket ileD46/nAg-tirI/02 2 A i EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES NC0027103 111 121 yr/mo/day 11/01/19 117 Inspection Type 18I C I (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) • - Enclosed you will find a copy of the Compliance Evaluation Inspection (CEI) report -for the routine annual inspection that I performed on January 19, 2011 at the Town of Pembroke Wastewater Treatment Plant, accompanied by Rhonda Locklear (ORC, WWTP), Jerry Brooks (Back -Up ORC),. and Branyun Bullard (WWTP Operator). As part of the inspection, a tour of the Wastewater Treatment Plant was conducted. All observations are in Section D. Summary of Findings/Comments of this inspection report. On the day of my inspection, the wastewater treatment plant appeared to be very well operated and maintained, and it appeared to be in compliance with the NPDES permit. I appreciate the time and professional courtesy that was extended by your staff during the inspection. No additional response is necessary from your office to the DWQ-Fayetteville Regional Office concerning this CEI report. Please contact me at (910) 433-3312 if you have any questions or comments. Page # 2 Permit: NC0027103 Owner - Facility: Pembroke VVVVfP Inspection Date: 01/19/2011 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant.generally.clean with acceptable housekeeping? ■ ❑ ❑ n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n ' n ■ ❑ Is the facility as described in the permit? ■ ❑ n n # Are there any special conditions for the permit? ■ n n n Is access to the plant site restricted to the general public? ■ ❑ ❑ n Is the inspector granted access to all areas for inspection? ■ n n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ n n Is all required information readily available, complete and current? ■ n ❑ n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? ■ n ❑ n Is the chain -of -custody complete? ■ n ❑ n Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ n ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ n n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? n n ■ n Is the ORC visitation log available and current? ■ n n ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ n n Is the backup operator certified at one grade less or greater than the facility classification? ■ n n n Is a copy of the current NPDES permit available on site? ■ ❑ n n Page # 3 i Permit: NC0027103 Owner - Facility: Pembroke WWTP Inspection Date: 01/19/2011 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year'sAnnual Report on file for review'? Comment: The Back Up ORCs were Karen Dial, Jerry Brooks, and Gary Harris. Effluent Pipe. Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Influent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Aerobic Digester Is the capacity, adequate? Is the mixing, adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: In order to avoid peak hours of electrical 'usage, a timer turned the aerator on from 12 Midnight to 10 AM. Land application of the sludge was performed by Porter Scientific. The last time that sludge was hauled was during November 2010. Bar Screens Type of bar screen a.Manual b. Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Yes No NA NE ODON Yes No NA NE ■❑❑❑ ■ ❑ ❑. ❑.. ❑ ❑■❑- Yes No NA NE ■ nnn ■ nnn ■ nnn ❑ ❑n■. Yes No NA NE ■ nnn n nn■ ■ nnn ■ nnn ■ nnn Yes No NA NE ■ ■ ■ nnn ■ n❑n. ■ n❑n' ■ nnn. Page # 4 Permit: NC0027103 Owner - Facility: Pembroke WNTP Inspection Date: 01/19/2011 Inspection Type: Compliance Evaluation Bar Screens Comment: Screenings were hauled to Robeson County Landfill. Routinely, a wastewater level sensor activates the mechanical bar screen (with approximately one inch openings) and the screenings conveyor belt. Yes No NA NE Grit Removal Yes No NA NE Type of grit removal a.Manual n b. Mechanical ■ Is the grit free of excessive organic matter? ■ n n n Is the grit free of excessive odor? ■ n n n # Is disposal of grit in compliance? ■ n n n Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • n n n Is the site free of excessive buildup of solids in center well of circular clarifier? ■ n n n Are weirs level? ■ n n n Is the site free of weir blockage? ■ n n n Is the site free of evidence of short-circuiting? ■ n n n Is scum removal adequate? ■ n n n Is the site free of excessive floating sludge? ■ n n n Is the drive unit operational? ■ n n n Is the return rate acceptable (low turbulence)? ■ n n n Is the overflow clear of excessive solids/pin floc? ■ n n n Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth) ■ n n n Comment: There was approximately 1/2 foot of blanket in the clarifiers on the day of this CEI. The scum trough skimmings flow to the aerobic digester. The center well of the two clarifier was free of solids buildup. Oxidation Ditches Yes No NA NE Are the aerators operational? ■ n n n Are the aerators free of excessive solids build up? ■ n n n # Is the foam the proper color for the treatment process? ■ n n n Does the foam cover less than 25% of the basin's surface? ■ n n n Page # 5 Permit: NC0027103 Owner - Facility: Pembroke WNTP Inspection Date: 01/19/2011 Inspection Type: Compliance Evaluation Oxidation Ditches Is the DO level acceptable? Are settleometer results acceptable (> 30 minutes)? Is the DO level acceptable?(1.0 to 3.0 mg/I) Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) Comment: The MLSS was 2,600 mg/L on the day of this CEI. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? ■ n n ❑ . Are cylinders protected from direct sunlight? ■ n n n Is there adequate reserve supply of disinfectant? ■ n n n Is the level of chlorine residual acceptable? ■ n n n Is the contact chamber free of growth, or sludge buildup? ■ n ❑ n Is there chlorine residual prior to de -chlorination? n n ■ n Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? n n ■ n If yes, then is there a Risk Management Plan on site? n n ■ n If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: One bag of lime was added per day (five days per week) to the splitter box that was located immediately before the oxidation ditch. De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Standby Power Is automatically activated standby power available? Yes No NA NE ■ 000 ■ nnn ■ nnn ■ nnn Yes No NA NE Gas ■ nnn ■ n•nn ■ nnn n n■n n n■n Yes No NA NE ■ nnn Page # 6 Permit: NC0027103 Owner - Facility: Pembroke VVVVTP Inspection Date: 01/19/2011 Inspection Type: Compliance Evaluation Standby Power Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: The generator was routinely operated for approximately 15 minutes once per week. The generator was tested under load approximately once per month. Pumps-RAS-WAS Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? Comment: Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: An IBM computer "Think Pad" was used to record and manage laboratory test data. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Yes No NA NE !.❑❑❑ ■ nnn n n■n ■ nnn ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn n nn■ Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn n nn■ n nn■ Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Page # 7 Regional Field Inspectors Check List for Field Parameters Name of site to be Inspected: Pembroke Date: 01-19-2011 Field certification # (if applicable): 552 NPDES #: NC0027103 Inspector: . Region: FRO I. Circle the parameter or parameters performed at this site. Residual Chlorine , Settleable Solids, pH DO , Conductivity, Temperature II. Instrumentation: A. Does the facility have the equipment necessary to analyze field parameters as circled above? A pH meter 2. A Residual Chlorine meter 3. DO meter 4. A Cone for settleable solids lAccumet XL25 HACH DR2800 HACH 550A fes Yes Yes No No No Yes No 5. A thermometer or meter that measures temperature. fres No HACH 550A1 6. Conductivity meter Yes No III. Calibration/Analysis: 1. Is the pH meter calibrated with 2 buffers and checked with a third buffer each day of use? 2. For Total Residual Chlorine, is a check standard analyzed each day of use? 3. Is the air calibration of the DO meter performed.. each day of use? 4. For Settleable Solids, is 1 liter of sample settled for 1 hour? 5. Is the temperature measuring device calibrated annually against a certified thermometer? 01/06/2011 6. For Conductivity, is a calibration standard analyzed each day of use? 'Yes Yes Yes No Yes No Yes Yes No IV. Documentation: 1. Is the date and time that the sample was collected documented? 2. Is the sample site documented? 3. Is the sample collector documented? 4. Is the analysis date and time documented? 5. Did the analyst sign the documentation? 6. Is record of calibration documented? 7. For Settleable Solids, is sample volume and 1 hour time settling time documented? 8. For Temperature, is the annual calibration of the measuring device documented? Comments: pH 4.0 exp date March 2011 pH 7.0 exp date January 2012 pH 10.0 exp date December 2011 pH millivolt reading of pH 7 buffer = -14 mV 1Yes 1Yes 'Yes 1Yes NYes 1Yes Yes 1Yes No No No No No Please submit a copy of this completed form to the Laboratory Certification Program. DWQ Lab Certification Chemistry Lab Courier # 52-01-01 FIELD INSPECTOR CHECKLIST REV. 04/23/2002 Imagery Cate Jun 18, 2008 Attachment Order 2-b: Town of Pembroke NC0027103 Process Flow Diagram Generator Waste Sludge uuiu�u� riuw .83 MGD Return Activated Sludge • Influent Pump Station Digester Return Line, Chlorine Contact