ROY COOPER Water Resources ENVIRONMENTAL QUALITY June 9, 2017 Tyler W Thomas Town of Pembroke 100 Union Chapel Rd Pembroke, NC 28372 SUBJECT: 5/11/2017 Compliance Sampling Inspection Town of Pembroke Pembroke WWTP Permit No: NC0027103 Robeson County Dear Mr Thomas: Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Enclosed please find a copy of the Compliance Sampling Inspection form from the inspection conducted on 5/11/2017. The Compliance Sampling Inspection was conducted by Mark Brantley of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0027103. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. • Maintenance and ORC logs were up to date. Bench sheets for the months of October 2016 and January 2017 were compared to the monthly eDMR's and no transcription errors were found . • As part of the inspection, samples were taken and sent to the NC Division of Water Resources Laboratory for testing. The samples were collected using the facility's composite sampler. Results for these samples are listed below: Parameter Results BOD 5.4 mg/L Coliform, MF Fecal 25 CFU/100 NH3 as N 0.05 mg/L Total suspended solids 6.2 mg/L • The bar screen was working but the braking controls that controlled the rake when descending was not. If you have not already done so, please repair this unit so it can" be maintained in working order. •,: "Nothinr� Cotpares...t..._ State of North Carolina.] Water Resources I Regional Operations Section I Fayetteville Regional Office 225 Green Street, Suite 714 I Fayetteville, North Carolina 28301 910 433 3300 I Fax 910 486 1010 I www.ncwater.org/pws/ Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3320. Sincerely, xi/ 4-4" Mark Brantley Environmental Program Consultant Division of Water Resources Water Quality Regional Operations Section cc: Tony Earl Baldwin, ORC Central Files Fayetteville Files , United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I 2I 2[ I 31 NC0027103 -111 121 17/05/11 117 Type 18. I s I• IIII111 Inspector 19 i Fac Type s i 201 21111111III1111IIIII11111IIIIII[I 11II (66 ` Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA 67 I I 70 13 . 1 71 I„ I 72 I„ i �J Reserved 73 I I �74 75� I I I 1 1 1 1 1 1 180: Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Pembroke WWTP NCSR 1339 - Pembroke NC 28372 Entry Time/Date 09:30AM 17/05/11 Permit Effective Date 16/08/01 Exit Time/Date 12:30PM 17/05/11 Permit Expiration Date 19/07/31 Name(s) of Onsite Representative(s)/Tities(s)/Phone and Fax Number(s) /// Tony Earl Baldwin/ORC/910-385-1429/ Other Facility Data Name,.Address of Responsible Official/Title/Phone and Fax Number • Contacted Tyler W Thomas,100 Union Chapel Rd Pembroke NC 28372/Town Manager/910-521-9758/9105210492 No . Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement � Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext727/ ;-l7 , Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Trent Allen FRO WQ//910 433 3300/ 02 /7 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES NC0027103 I11 121 yr/mo/day 17/05/11 17 Inspection Type 18[j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments Facility was dean and neat in appearance at the time of the inspection. Maintenance and ORC logs were up to date. Bench sheets for the months of October 2016 and January 2017 were compared to the monthly eDMR As part of the inspection, samples were taken and sent to the NC Division of Water Resources Laboratory for testing. The samples were collected using the facility Parameter Results BOD 5.4 mg/L Coliform, MF Fecal 25 CFU/100 NH3 as N 0.05 mg/L Total Suspended Solids 6.2 mg/L Page# 2 Permit: NC0027103 Owner -Facility: Pembroke WWrP Inspection Date: 05/11/2017 Inspection Type: Compliance Sampling Operations & Maintenance Is the plant generally clean withiacceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable • Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? `Comment: The current permit expires July 31, 2019. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are•analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling . Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete:rdo.they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24R with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑. Yes No NA •NE ❑ ❑111❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ■ ❑ ❑ ❑ II ❑ ❑ ❑ II ❑ ❑ ❑ ■ ❑ ❑ ❑ • • II ❑ ❑ ❑ ▪ ❑ ❑ ❑ Cl ❑ IN ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 3 Permit NC0027103 Inspection Date: 05/11/2017 Owner - Facility: Pembroke WVVTP Inspection Type: Compliance Sampling Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is -the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Flow meter was last calibrated in January 2017 by Delta Systems. Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Yes No NA NE • ❑ ❑ ❑ Yes No NA NE 11 ❑ Cl ❑ IN ❑ ❑ ❑ ❑ ❑ 1 ❑ Yes No NA NE II ❑ ❑ ❑ ❑ ❑ ❑ II ❑ ❑ ❑ ❑ ❑ 11 ❑ Yes No NA NE . ❑ ❑ ❑ ■❑❑❑ • ❑ ❑ ❑ 11 ❑ ❑ ❑ • ❑ ❑ ❑. ❑ ❑ ❑ • ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 4 Permit: NC0027103 Inspection Date: 05/11/2017 Owner -Facility: Pembroke WWTP Inspection Type: Compliance Sampling Bar Screens Is the unit in good condition? 111 Yes No. NA NE ❑ ❑ ❑ Comment: The bar screen was working but the braking controls that controlled the rake when descending was not. If you have not already done so please repair this unit so it can be maintained in working order. Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor?. # Is disposal of grit in compliance? Comment: Secondary Clarifier • Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately of the sidewall depth) Yes No NA NE 0 • • ❑ ❑ ❑ • ❑ ❑ ❑ • 0 ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ MI ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ IN ❑ ❑ -❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ 1 ❑ ❑ ❑ NI ❑ ❑ ❑ Comment: One clarifer was in operation and the other was not in service at the time of the inspection. Oxidation Ditches Are the aerators operational? Are the aerators free of excessive solids build up? # Is the foam the proper color for the treatment process'? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ MI ❑ ❑ ❑ • ❑ ❑ ❑ Page# 5 Permit: NC00271 03 Owner - Facility: Pembroke WWTP Inspection Date: 05/11/2017 Inspection Type: Compliance Sampling Oxidation Ditches Are settleometer results acceptable (> 30 minutes)? Is the DO level acceptable?(1.0 to 3.0 mg/I) Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) Comment: Aerators are rotated from hi to low as needed. Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to 'de -chlorination? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ IN ❑ ❑ ❑ II ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ 0 ❑ ❑ IN ❑ ❑ ❑ II ❑ Comment: Both sides of the contact chamber were in operation. No sludge blanket was present at the time of the inspection. A sludge judge was used to verify this. De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Influent S.amplinq # Is composite sampling" flow proportional? Is sample collected above side streams? Yes No NA NE • Gas • ❑ ❑ ❑ II ❑ ❑ ❑ II ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE ❑ IN ❑ ❑ • ❑ ❑ ❑ Page# 6 Permit NC0027103 Inspection Date: 05/11/2017 Owner - Facility: Pembroke VWVTP Inspection Type: Compliance Sampling Influent Sampling Yes No NA NE Is proper volume collected? •❑ ❑ ❑ Is the tubing clean? # Is proper temperature set for sample storage (kept at Tess than or equal to 6.0 degrees • ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? • 0 ❑ ❑ Comment: Effluent Samplinq Yes No NA NE Is composite sampling flow proportional? •❑ 0 0 Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? •❑ ❑ 0 Is the tubing clean? •❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Roo ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ 0 ❑ representative)? Comment: Upstream / Downstream Sampling Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: Yes No NA NE ❑ ❑ ❑ Page# 7 AC38661 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: PEMBROKE WWTP Effluent County: ROBESON Collector. , M BRANTHEY VisitlD Region: - FRO Report To FRO Location ID: FRO_NLC River Basin Lumber Collect Date: 05/11/2017 Priority COMPLIANCE Emergency Collect Time: • 10_45 , Sample Matrix: WASTEWATER COC Yes/No Sample Depth - Loc. Type: Effluent Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Sample ID: AC38661 PO Number # Date Received: 05/12/2017 Time Received: 08_15_ Labworks LoginlD TASCENZOI Delivery Method NC Courier Final Report Date: 5/24/17 Report Print Date: 05/24/2017 CAS # Analyte-Name Sample temperature at receipt by lab Result/ PQL Qualifier LAB 2.1 Units °C Method Analysis Reference _ Date Validated by 5/12/17 CGREEN BOD, 5-Day in liquid 2.0 MIC 5.4 mg/ SM 5210 B-2001 5/12/17 ESTAFFORDI Coliform, MF Fecal in liquid 1 25 Q1 CFU/100m1 SM 9222 D-1997 5/12/17 ESTAFFORD1 NH3 as N in liquid NUT 0.02 0.05 mg/L as N EPA 350.1 REV 2 5/12/17 CGREEN Residue_Suspended in liquid 6.2 WET 6.2 U mg/L SM 2540 D-1997 5/16/17 CGREEN NoO2//o3 WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 1 of 1 e -1r /I 4: on - far• screen ,f o% ak Dlc.ohhooi C.IPCs olt, — 2o4sna.�/s 1 cj i,rc r — / c'air "s /'t/HAof , k.r I s C/a , n fir l '.;e, - con'iacf C4a4er - lfvq s,Ve, �! cf so, s ,s f I `/%/"Ar Ga �i dro - In JYf�f o 1C, Pact//4. uses e ��odiL IS 9 O u ex/3;re/ ate 1 o — 0 K, La� H "iJ er ALc u I'it-t ectl;LruLe Tern erµjure From IM Mel 1i/ l a -11i'a.-'/G Gla✓T /Ya. 1-4', 4 lo., Gi e/ec /lc .2 o Cti` rd.., HI e.w4s / C.►! ru % /'v GP 4,c• 7Yi� toxcs 34'17 . f, 2d /q tr7 coy 4I ,•s- kLe eae k-•70 sizir olat /%+Ca 4, N��ti t2/?2 O0 ..7s^ 23 (-© so '7 S e, 1 r o 1321 36 0 ,-.79 Son- /'7 (evro„t1 Ao esisedtop YST 60_ Do �QG� Fir .� s Sep dmp• Teel - North Carolina Division of Water Resources Water Sample Collection & Submittal Form Central Laboratory (Water Sciences Section) Y'jb ,= f��{�§ s�opteorlai k i �• : � v 9 Ib i ab U e j� f t r ---=-- ----__---- . CdBtiratS►p LoCert,ori DeSCr ption ^ Latit) t)e ,gc ''Cr Paie hece ed a coun rectori9fPriority rt7 - r� (r .,.. •-:r { Jrc e:,..? Y �x* Water, Ottnta ��a.uY..u�...e, .a....�,...:� ❑ Surface Ground❑ ❑ Waste ❑Blank ❑ Solution fit�M + ,= Ltican° Yl,pe -F �� u.. e ._�4. .....,: Fr....i.J ....ivF...l.. ❑River/Stream ❑ Lake Estuary ❑Canal ❑Stormwater Monitoring ❑WaterSupply Effluent Influent ❑Trp Blank.. ❑Other: ,(Iv J: Ti,neREteho, l '•i J' DWR Reg on , ,i. > 1 DW ? O Ce (oragettsYniiie), ❑Ambient ❑ Routine Compliance❑ ❑ COC Emer enc g ❑QA ': Retelvell,By t Ritte:,if, Basra .�k. ... ii ,...:.f z Data r , y UStateCourier i�,ellvasytiVie, o❑Hand Delivery rt Other: ❑ Motes.Me ' „ , > , r ❑ Chlorinated De -chlorinated in Field . oinpl)nr FJ , Rr❑Composite : i' od'AYF.f/ ❑ Filtered in Field Dissolved analysis: Enter "DIS" in check -boxes for parameters x 3, a Repehr) 4j100)4`Camn# M:AiHiIiticr0bicil0BYie000i0t0r$VMUlagigilM;.ti.r t v:,a i>., MBAS (surfactants) mg/L . e 5 , MetaaslfliWrneterS�`t n ,, r 7 ..(Sn) u, :�'; ,1:: Tin L pg/ Acidity, as CaCO3, to pH 4.5/8.3 mg/L Oil and Grease, HEM, Total -Recoverable mg/L Aluminum (Al) pg/L Titanium (TO. pg/L Alkalinity, as CaCO3,to pH 4.5/8.3 mg/L Phenols, Total Recoverable pg/L Antimony (Sb) , pg/L Vanadium (V) pg/L BCD: Biochemical Oxygen Demand, 5-day mg/L Residue: Total. (Total Solids) mg/L Arsenic (As) pg/L Zinc (Zn) pg/L cBOD: Carbonaceous BOD, 5-day mg/L Residue: Volatile/Fixed, Total mg/L Barium (Ba) pg/L Coliform: Fecal MF /100m1 Residue: Suspended (Suspended Solids) mg/L Beryllium (Be) pg/L Boron (B), Total pg/L Coliform: Total MF /10om1 Residue: Volatile/Fixed, Suspended mg/L Cadmium (Cd) pg/L Mercury 1631, low-level ng/L Coliform: Tube Fecal /100m1 TDS - Total Dissolved Solids mg/L Calcium (Ca) mg/L Coliform: Tube Total /100m1 Silica mg/L Chromium (Cr), Total pg/L ;- i Orgahig R3Carflete4ft' fi` >;i ;:- Specific Conductance, at 25 °C umhos/cm Sulfide mg/L Cobalt (Co) pg/L Acid Herbicides TOC - Total Organic Carbon mg/L Tannin & Lignin' mg/L Copper (Cu) pg/L Organochlorine Pesticides Turbidity NTU Iran (Fe) pg/L Organonitrogen Pesticides ,'; .OtherParame ersR;•1 1,r' :,;� ` , ,`,,,,,+'-c,•Ri{ d y,; Lead (Pb) pg/L Organophosphorus Pesticides i Wetcklemisiryparameters .. ,. - .11. 01 <,. ,k, (,F,t0 pH s.u. -Lithium (Li) pg/L PCBs•(po_'(ychlorinated biphenyls) Bromide • mg/L " Hardness, Total as CaCO3 - by titration mg/L Magnesium (Mg) mg/L Mr • ' Chloride mg/L Manganese (Mn) pg/L Semi -Volatile Organics (BNAs) Fluoride mg/L Mercury (Hg) pg/L TPH Diesel Range Sulfate mg/L la.A 9,iitrient :0ara0e00, h,. ,,w.. ,, `;; , v; Molybdenum (Mo) pg/L Chlorophyll a pg/L Ammonia as N (NH3-N) mg/L Nickel (Ni) pg/L Volatile Organics (VOA) Color: ADM] c.u. - Nitrate -Nitrite as N (NO3+NO2-N) mg/L Potassium (K) mg/L Color: Platinum Cobalt c.u. Total Kjeldahl Nitrogen as N (TKN) mg/L Selenium (Se) pg/L TPH Gasoline Range COD: Chemical Oxygen Demand mg/L Total Phosphorus as P (TP) mg/L Silver (Ag) pg/L Cyanide, Total mg/L Nitrite as N (NO2-N) mg/L Sodium (Na) mg/L PI Biological, {,;:. 0... , a; „ Formaldehyde - mg/L Nitrate as N (NO3-N calculated) mg/L Strontium (Sr) pg/L Phytoplankton / Algae Hexavalent Chromium (Cr6+) mg/L • Orthophosphate as P (PO4) mg/L Thallium (TI) - - pg/L LAB COMMENTS : Pa`rameters(oRhanal, Revision: 2/06/2015