Loading...
HomeMy WebLinkAboutSW7100908_APPROVED PLANS_20100930STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW���(��. DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE�j��� Q, YYYYM M D D OWNER: EASTERN PRIDE, INC. GENERAL CONTRACTOR - STOCKS AND TAYLOR CONSTRUCTION, INC PROPERTY SIZE 1.09 AC - THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE MAP 3720567500J, DATED MAY 15, 2003 AND IS LOCATED IN A SPECIAL FLOOD HAZARD AREA (LOCATED IN SHADED ZONE AE); SUMMARY OF SITE: GENERAL BUILDING INFORMATION BUILDING USE: COMMERCIAL - RETAIL BUILDING SIZE: 9100 SF BUILDING INF0:8498SF RETAIL 602 SF STORAGE LOT SIZE 1.09 AC. ZONING INFORMATION: ZONING: 0&1 SETBACKS: MINIMUM BUILDING SETBACKS (UNLESS NOTED) FRONT:30 FEET SIDE: 8 FEET SIDE CORNER: 15 FEET REAR: 15 FEET UTILITIES: WATER LINE - CITY OF WASHINGTON WASTEWATER - CITY OF WASHINGTON WASTEWATER SERVICE: 4" GRAVITY SERVICE WATER SERVICE: 1" SERVICE LINE ELECTRIC SERVICE- CITY OF WASHINGTON NATURAL GAS - PIEDMONT NATURAL GAS: 1: SERVICE ALL NEW SERVICES SHALL MEET ALL NC BUILDING CODE REQUIREMENTS ALL EXISTING UTILITIES ARE SHOWN BASED ON FIELD EVIDENCE PRIOR TO ANY DIGGING NC ONE CALL SHALL BE CALLED AND CONFIRM LOCATION AND SIZE OF ALL EXISTING UTILITIES. LANDSCAPING AND VEGETATION BUFFER YARDS A - & BUFFER YARD ALONG PERIMETER OF SITE B- 6' BUFFER YARD ALONG EASTERN MOST PROPERTY LINE D- 10' BUFFER YARD WITH 6' WOODEN FENCE ALONG RESIDENTIAL SIDE BUFFER YARD A REQUIREMENTS 374 LF 20 SHRUBS / 100LF BUFFER YARD B REQUIREMENTS 346 LF 3 EVERGREEN TREES / 100BF ! 100 LF BUFFER YARD D REQUIREMENTS 350 LF YOUMETRE'OF 5 SMALL TREES / I GO LF 16 EVERGREEN SHRUBS / 10OLF LANDSCAPE MAY BE REDUCED BY 50% IF FENCE IS INSTALLED PARKING REQUIREMENTS PARKING SPACES TO BE TYPICAL (9 FEET X 18 FEET) UNLESS OTHERWISE NOTED PARKING SPACES REQUIRED: 43 PARKING BUILDING CODE REQUIREMENTS: (1 SPACE PER 20D SF RETAIL) PARKING PROVIDED TOTAL - 46 HANDICAPPED ACCESSIBLE - 2 HANDICAPPED ACCESSIBLE PARKING TO BE (2 EQUAL SPACES) PER LOCAL CODE PLANTING REQUIREMENTS: O 75 SHRUBS BUFFER YARD A 10 EVERGREEN SHRUBS + O 10 SMALL TREES BUFFER YARD B 7 LARGE TREES O 11 SMALL TREES + 28 SHRUBS FOR BUFFER YARD D WITH A 6' WOODEN FENCE A. LARGE TREE CATEGORY B. SMALL TREE CATEGORY CREPE MYRnE C. EVERGREEN SHRUB CATEGORY JAPANESE PRIVETTE EAsdng Ferxwlg. When there la an existing fence which creates a complete visual screen for at Waist five (5) feet In height or an adioining property owners yard, and that fence extends along a minimum of fifty (50) percent of the abutting yard In question as determined by the Director of planning and Development then the developer may elect to use one of the applicable aftemative buHeryards. (1) Bufferyard D - mk*num width - ten (f0) feet; required pant materials per one hundred (100) feet - two (2) large trees (minimum 70 percent evergreen); three (3) small trees; and twenty-five (25) evergreen shrubs; PROPOSED 1" WATER METER_ W/BACKFLOW PREVENTER AND 1" IRRIGATION TAP W/ METER O Z w w w 0 3 _ to Z > h= Oul Zy x O w COD a Vl PROPOSED 1" GAS 4" SEWER SERVICE SERVICE BUFFER YARD D 10' PROP. 6' WOODEN - PRIVACY FENCE EXIST. MICHAEL A. SIMONE IDB. 1518, P. 0664 ZONING RHD t -------------------------- i tt� tO_;W_-- A . A 14 �— v-r- "' BUFFER YARD B V " HOUSE OF PRAYER DELIVERANCE MINISTRY DB. 1726, P. 0831 I ZONING O & I 0 rn SITE PLAN D N SCALE: V =20' N61' 57' 00.39"W VICINITY MAP Minimum Plant Size. Unless otherwise indicated elsewhere in this Section, all plant materials shall meet the following minimum size standards at the time of planting: Planting Material Type Minimum Planting Size Large Tree Single -Stem 1 1/2 inch caliper Multi -Stem Clump 6 feet in height Small Tree 4 feet in height Evergreen Shrubs 1foot In height (d) Spacing In Bufferyards C, D, E, and F. Bufferyards C, D, E, and F are intended to create a complete visual screening year round. Therefore, proposed and existing vegetation should be spaced to accomplish this purpose. No more than two (2) continuous feet of horizontal plane, as measured and viewed perpendicular from the property line, may be void of vegetation at least six (6) feet in height within ten (10) years of plantinG 7 0 am PPE TO 1 rau SHRUB PLANTING NOT 10 go" TREE PLANTING NAIL WMW E APPROVED ', > . "i-''AROLINA ENVIRONMENTAL VANAC! EMENTCOMMISSION !L S!')N OF WATER QUALITY s0_L— EXPRESS SEP 21 201(l! NC DENR 0 0 0 O) 01 0 CIC I a_ a a z w w c CL 3 v Q O O a a Z ~ O �Z >0 a >� L6 (n Q 0 Q 0 Z w O 42 Z ri a 3 OFESSIONAL SEAL ARp1 •, SEAL 20212 PAUU00 ENGINEERING SERVICES, LICENSE NO. P-0530 PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 27889 252-945-2983 pespllc@embargma0.com m a 0 10008 1"=20' No. CM001 , I DRAINAGE NOTES 0 0 a r r r N N N 0) 00) I ,. t 4 TOTAL SITE AREA DISTURBED =1.09AC TOTAL DRAINAGE AREA = 1.14AC TOTAL IMPERVIOUS AREA = 0.76 AC % IMPERVIOUS = 66% THERE IS OFFSITE WATER DRAINING ACROSS THIS PROPERTY. SEE DETAIL SHEET FOR CROSS SECTION OF THE BID RETENTION POND PRIOR TO FINAL CONSTRUCTION OF THE BID RETENTION POND ALL DISTURBED AREAS NEED TO BE STABILIZED. THERE ARE NO WETLANDS ON THIS PROPERTY. EROS 1. OBTAIN AND POST COPY OF CERTIFICATE OF EROSION CONTROL PLAN APPROVAL. 2. CLEAR SITE ONLY AS NECESSARY TO INSTALL EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS OR SPECIFIED IN THE SPECIFICATIONS. 3. ONCE EROSION CONTROL DEVICES ARE INSTALLED, BEGIN CONSTRUCTION OPERATIONS. 4. MAINTAIN EROSION CONTROL DEVICES AS NECESSARY DURING CONSTRUCTION. INSPECT DEVICES AFTER EVERY RAINFALL EVENT AND CLEAN OUT RAPS AND /OR CHECK DAMS WHEN HALF FULL, 5. AS CONSTRUCTION PROGRESSES, INSTALL ADDITIONAL EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, OR AS NEEDED OR DIRECTED BY ENGINEER. 6. SEED AND MULCH DISTURBED AREAS WITHIN FIFTEEN (15) WORKING DAYS: A. UPON COMPLETION OF ANY PHASE OF CONSTRUCTION B. WHEN WORK WILL NOT PROCEED IN AN AREA WITHIN THE ABOVE TIME FRAME. 7. AFTER SITE IS STABILIZED, REQUEST AN INSPECTION BY HE ENGINEER. UPON APPROVAL OF SITE STABILIZATION, REMOVE TEMPORARY EROSION DEVICES, DRESS OUT AREA AND SEED AND MUCH. PERMANENT EROSION CONTROL DEVICES SHALL BE INSTALLED AND APPROVED BY ENGINEER. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 4INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF APPLICABLE. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM. REASONABLY UNIFORM SEEDBED 1S PREPARED 4 TO 6 INCHES DEEP. SEED ON FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDING WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISHED FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. NOTE: CONTRACTOR SHALL PROVIDE A PERMANENT SEED COVER ON ALL AREAS DISTURBED DURING CONSTRUCTION OPERATIONS, INCLUDING ANY DISTURBANCE TO THOSE AREAS THAT WERE SEEDED DURING PREVIOUS WORK. - THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE MAP 3720567500J, DATED MAY 15, 2003 AND IS LOCATED IN A SPECIAL FLOOD HAZARD AREA (LOCATED IN SHADED ZONE AE); ALL SPOT ELEVATIONS ARE OF TOP OF CURB UNLESS OTHERWISE NOTED CONTOURS ARE SHOWN IN V INCREMENTS BIO RETENTION SCHEDULE AREA NUMBER 1 DISTURBED AREA AC 1.09 IMPERVIOUS AREA 0.76 TOTAL DRAINAGE AREA 1.14 OFF SITE DRAINAGE AREA .05 1" ELEVATION VOL 50 . EMERGENCY SPILLWAY ELE 6.38 �— VOLUME 1 YR 24 HR EVENT 4911 CF WATER QUALITY VOLUME 3997 BIO RETENTION SURFACE AREA AVG 4630 SF ►V RIM = 7.96 i INV OUT = 6.67 W/ INLET PROTECTION r. DA =0.21 AC r •. I O l 1. Temporary Seeft Dec. 1 -Apr. 15 Rye (Grain) 120 Kobe Lespedeza 50 Apr. 15 - Aug. 15 Getman~ 40 Aug.15. Dec. 1 Rye (Grain) 120 Lime 3,000 FartM¢x 10.10.10 am Mulch Strew 4,00D 2. Permanent Seedng P gain i10esifi.Lm Pouts/Am Sept. 1 - Oct 31 Tall Fescue 200 Rye (grain) 25 L"ane 4,000 Fertpiier 10-10-10 1.000 Mulch Straw 4,000 US 264 / V CLASS B 1 1----- -------------------- -------- 1 MICHAEL A. SIMONE o0 1 DB. 1518, P. 0664 j � \ �— — — .— — — — — — — — — — — — — — — — — — — — — — — — —— — — — — — — — — — HOUSE OF PRAYER DELIVERANCE -MINISTRY IDB. 1726, P. 0831 - THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE MAP 3720567500J, DATED MAY 15, 2003 AND IS LOCATED IN A SPECIAL FLOOD HAZARD AREA (LOCATED IN SHADED ZONE AE); GRADING PLAN SCALE: 1" =ZY / 7_52 FLUME CONCRETE FLUME Z / OPENING W/ / RIP RAP OUTLET PROTECTION L= 5' DA= 0.39 AC W= 5' 010=3.31CFS CLASS B 06 w w / ,C� W W Q F=— p W " I LU p a a W Lu.f T O J U C m C, J z G O TEMP ROCK CHECK DAM Z Q _J S� MP. SEDIMENT TRAP t=0.9AC TEMPORARY DIVERSION 10 = CFS 75' TEMPORARY CHECK DAM 3' :36 SILT FENCE CI INLET PROTECTION OUTLET PROTECTION �� BIO RETENTION AREA 10'OVERFLOWWEIR CONSTRUCTION ENTRANCE ELEVATION 6.39 N61. 5t 000.39"W OWNER: EASTERN PRIDE, INC. GENERAL CONTRACTOR - STOCKS AND TAYLOR CONSTRUCTION, INC N 3 r'rw7� KA 0 W W 0- W Q N W g 0 z w O Z a 3 PROFESSIONAL SEAL SEAL 20212 F� ...... ,, ",' MPHLE �''4u.nuT PAMLICO ENGINEERING SERVICES, PLLC LICENSE NO. P-0530 PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 27889 252-945-2983 pespllc@embargmai.com 10008 1 a = 20r Sheet No. CiiiiiiiieO02 , ll:1 � �:.._L!. !i _: �."�. _,.•.,.1 :_ �:.�: _.�-_. ,.'- ._ul _... �..i.. i. ..l.�,, 1110"LAdIL4j" !:_`t __1 NIX OF C-6' IRON TIP OF SLOPE OR PROPERTY _INC —, EXTEND TO PRMERTY LINE WHIC EVER FINISHED GRADE IS GREATER, 24' MIN. FROM THE F WTTOI R DITCH -I CIPPER SERVICE TUBING LENGTH AS REVS BITCH L NETER METER STOP / B4 R[PfE�Hi1PpDRTS MWSE SERVICE BY OTFERS \_KEEP LOW SLAP( METER NX TO BE FURNISHED AND INSTALLED BY UTILITY O CONTRACTOR SERVICE SADDLES SHALL BE USED M may, ALL WATER LINES 4'AND SMALLER. SERVICE SADDLES SHAD. ALSO BE USED ON 6' AND LANCER SERVICE SADDLE PVC WATER MANS WHICH W NDT MEET THE REOWRIONENTS OF AWWA C-900, MASS 151 If N1HUk COVER OVER SERVICE LINE SHALL BE 24'. "ATER NAN MIER BOR SH NOT BE MSTA LED IN SLOPE OF DITCH. 1 3 4" - 1" WATER SERVICE DETAIL -Scale'. To Scale: 810K ILTEt aF 1 =AWL P1ACm AOANaI' PE11C•p WAi FANKIlim 8'-0- MAX 8'-0" MAX 1r-r Ball I13 + BAO" . Moll r x r aim Pasts MQM A PasTa W AT DOMM of r WaN N MM sAOM L a. ANCVMO M a r Is r AM Fat W 10 K 1001/ACM C. PPWAf OM U AM %V0 AHM OF SILT FMM TO ACT AS A 0. R.MITY MUWMA Y UK MA1RT6 & OR VMW IM01F APPWVAL Ffat 6 SILT FENCE Scale: Not To Scale: � 1 • yiyA,�-yip«=/ A'af:• Al _ + ��''i���' s I1.5' MIN. 9 TYP. DRAINAGE SWALE Scale- Not To Scale: TOP ELEV OF STORMWATER 1• FLOOD STORAGE ZONE FS WASHED 5' SEDIMENT STORAGE ZONE (TOTAL BASIN CAPACITY) I 1•-D" MAX SEDIMENT DEPTH • :••'i r 5. "B" • -11= 11-�u-u�11=u.=u.=a^n�=1�--n--11�—u- • • • - f.=,,I1:g.Il ;;,N.;,.11; i1=,.Ilgfl:�ll';, If.;,.lf.;—.IC�ii:�ll - • • ,. ,, :_ ,, : • 10 ®` TOP OF POND DITCH AND BURY FILTER FABRIC FILTER FABRIC EDGE WEIR LENGTH - 12' (MIN. 12" OF FABRIC) 3 OVERFLOW WEIR DETAIL Scale: Not To Scale: INSTALLATION OF NETTING AND MATTING PRODUCTS DESIGNED TO CONTROL EROSION SHOULD BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ANY MAT OR BLANKETTYPE PRODUCT USED AS PROTECTIVE MULCH SHOULD PROVIDE COVER OF AT LEAST 30 % OF THE SURFACE WHERE IT IS APPLIED. INSTALLATION IS ILLUSTRATED BELOW. 1.APPLY LIME, FERTILIZER AND SEED BEFORE LAYING THE NET OR MAT. IF OPENWEAVENETTING IS USED, LIME MAYBE INCORPORATED BEFORE INSTALLING THE NET AND FERTILIZER AND SEED SPRAYED ON AFTERWARD. 2. START LAYING THE NET FROM THE TOP OF THE CHANNEL OR SLOPE AND UNROLL IT DOWN THE GRADE. ALLOW NETTING TO LAY LOOSELY ON THE SOIL BUT WITHOUT WRINKLES -DO NOT STRETCH. 3. TO SECURE THE NET, BURY THE UPSLOPE END IN A SLOT OR TRENCH NO LESS THAN 6 INCHES DEEP, COVER WITH SOIL, AND TAMP FIRMLY. STAPLE THE NET EVERY 12 INCHES ACROSS THE TOP END AND EVERY 3 FT AROUND THE EDGES AND BOTTOM. WHERE 2 STRIPS OF NET ARE LAID SIDE BY SIDE, THE ADJACENT EDGES SHOULD BE OVERLAPPED 31NCHES AND STAPLED TOGETHER. EACH STRIP OF NETTING SHOULD ALSO BE STAPLED DOWN THE CENTER, EVERY 3 FT. DO NOT STRETCH THE NET WHEN APPLYING STAPLES. 4. TO JOIN TWO STRIPS, CUT A TRENCH TO ANCHOR THE END OF THE NEW NET. OVERLAP THE END OF THE PREVIOUS ROLL 18 INCHES, AND SAMPLE EVERY 12 INCHES JUST BELOW THE ANCHOR SLOT. MAINTENANCE INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK FOR RILL EROSION, DISLOCATION, OR FAILURE. WHERE EROSION IS OBSERVED, APPLY ADDITIONAL MULCH. IF WASHOUT OCCURS, REPAIR THE SLOPE GRADE, RESEED, AND REINSTALL MULCH. CONTINUE INSPECTIONS UNTIL VEGETATION IS FIRMLY ESTABLISHED. SHOWN ON PLANS y 4--1' MIN SECTION THRU BASIN & FILTER TOTAL BASIN CAPACITY CLEAN BASIN WHEN MAXIMUM LEVEL OF SEDIMENT IS REACHED. IN CHANNELS, ROLL OUT STRIPS OF NETTING PARALLEL TO THE DIRECTION OF FLOW AND OVER THE PROCTECTIVE MULCH. r OA IP ANCHOR NETTING 6-NCH THE CH.tN AAND OVERLAPPING. IN STRIPS BY NCHORING TEMP. DITCH LINER Scale: Not To Scale: 2' MIN. CAF" PSI RAP UP BANK , (� N0. 5 WASHED STONE F. .7 iP NA -=AL -FFADE ll ili _wE CLASS B RIP RAP - WITH FILTER FABRIC 6" MIN. �i' FREEBOARC (MIN.) t DEPTH OF DITCH 14 Check Dam Detail Scale: Not To Scale: 1� #57 WASHED STONE PLACED TO A HEIGHT OF 12"-18" MIN. ABOVE TOP OF BOX 4 DROP INLET PROTECTION Scale: Not To Scale- al"D.A P \ - Z f "-dnV+.M lepk'. "aRR �`� x Rnxes t .w+ aax•c^. � o- s 3• IM ,T V, $t-il Ski 59 a- vev Tv£R w a �y A -•v 4J-iT t5 - �.N 91 !W WtCI R Nta1Y '. 1 £ ♦ tlNd t:r. a ty wxA W-¢`TS N.eT a✓ tSN I u+! u D 9` } a. aFtia F�tYr's R`t3BER .• .,r apA. r �JA 4� YiVf �WE55� �;,;y ti5. $ CATCH BASIN DETAIL Scale: Not To Scale: ! ., 14- , a vt'T 3------- bedal side sloies.-Rip-roP VdlfisntD. role.. 10 OUTLET PROTECTION Scale: Not To Sole: a-r ����� •im eMFA° °�tuan • tomiW.BBi 1wTAaN POW" am car NAx 11 ItAx \\\\\\ \ \ \ \\\\\ \ SW �a PLAM MM TYPICAL DIVERSION 1 Scale: Not To Scale: 0 0 0 r r r 0 0 0 0 W M d) THE SOIL MEDIA TYPE, 1 CONSTRUCTION SEQUENCING THE SOIL MIX SHOULD BE UNIFORM AND FREE OF STONES, THE DRAINAGE AREA TO THE CELL SHOULD BE STABILIZED STUMPS, ROOTS OR OTHER SIMILAR I MATERIAL GREATER THAN 2 INCHES. IT SHOULD BE A 0- O) BEFORE CELL CONSTRUCTION BEGINS IN ORDER 0_ d TO PREVENT CLOGGING. FOR ROADWAYS DRAINING TO THE HOMOGENOUS SOIL MIX OF 85-88 PERCENT BY VOLUME SAND (USDA SOIL TEXTURAL CLASSIFICATION), 12 � i Z W CELL, THE SUBBASE COURSE (CRUSHER RUN) PERCENT FINES SILT AND CLAY), M p ( AND THE BASE COURSE LAYER OF ASPHALT NEED TO BE IN -0 W AND 3 TO 5 PERCENT ORGANIC MATTER (SUCH AS PEAT MOSS) 0) o PLACE PRIOR TO CELL CONSTRUCTION. IF FINES � W vi GET WASHED INTO THE EXCAVATED CELL, THEY MUST BE SHALL BE USED. ADDITIONALLY, THE PHOSPHORUS CONTENT OF c r Y Q THE SOIL MIX SHOULD BE LOW. SOIL MEDIA SHOULD 7 REMOVED BEFORE BUILDING THE CELL IN 01 y ORDER TO RESTORE THE tNSITU SOILS PERMEABILITY. IT IS BE SENT TO NC DEPARTMENT OF AGRICULTURE INCDA] LABS TO m t RECOMMENDED THE CELL MEDIA BE BE ANALYZED. THE P4NDEX FOR 0 V W I" BIORETENTION SOIL MEDIA SHOULD ALWAYS RANGE BETWEEN W COVERED WITH IMPERMEABLE PLASTIC DURING � CONSTRUCTION. 10 AND 30, REGARDLESS OF THE TARGET Q POLLUTANT (HARDY ET. AL., 2003 AND HUNT ET. AL., 2006). 0 ONCE B10 RETENTION AREA IS BEING CONSTRUCTED THE THE MEDIA SHOULD BE TESTED TO DETERMINE AN ACTUAL CONTRACTOR IS TO CALL THE ENGINEER FOR INSPECTION DRAINAGE RATE AFTER PLACEMENT. THE 24 HOUR NOTICE IS REQUIRED FOR ALL INSPECTIONS. OF THE UNDER DRAIN SYSTEM PRIOR TO BACKFIPERMEABILITY SHOULD FALL BETWEEN 1 AND 6 INCHES PER HOUR, AND 1-2 INCHES PER HOUR IS a PREFERRED. Q Note: Use inlet protection to dissipate energy and remove sediment (forebay, stone/veg. filter strip, reinforced swale, etc.) z Z Grass, SOD W •. Engineered fill media Grassed cells must be sodded and the sod must O O not be grown In soil with an impermeable layer. } 0 o I— N SIDE SLOPE o O U =• NO GREATER THA HGL 1- VOL =5.8a ~ •_!E 3:1 12N i� TOP OF GF2AS3 = 5.00 .. ...... 2' MIN — } BOTTOM OF CELL = 3.00 immi SHWT=0.461 BIO RETENTION DETAIL Scale: Not To Scale: aS.A:L 9rB '/2' A. YiT AWDE raw O Q AO A" t0 �:RIK UAW !' O.EAMNEE � g b J NY PARR' s7wAx APF:1C>t j £ � u P.E NYE Y 1 CR �Hnt41.. t •. 4DP MF F WR3. L NOTED -i'ts. -APPLICATION! ;Ate hAl iNgth Of 'he s.£.1ve frenet ems be „ s • tomPa�. fn •• n € IF ow pip, oid riffioaf to 0. D ee!wem tar Wa FW. aM Rmrgrk bs a t-sDR-; ASTU AVC 0-259e f a_Pe 3. . bM4. Maas. mwmbty ` py ' j YA BlowarolNl Mai! N oecWs4 N ,F57 ,knee •addiag and e o '- e M4r41Ag of ierdos pWe must Aampty .iNf Claw B Y Outo.2 (See Wddbtg 44W for 9ra+k inw q) - '"-oCDG.O �Y' . •w i%"f: A, A. C9W a 14%% eye is: pe<(Wloa Wttome tr,a%R aMy. SP.E SET, 11 SANITARY SEWER SERVICE Scale: Not To Scale: , APMICAME AT ALL FOULS OF IMBIM A ERM OMx. WE tb SftetiaO. FIE4N7R ill = OI NE AB• ➢MELT 36' RCP NAEREB141a MUST BE FINDSOM NOTES - A. NG0.0.T./OOR AWAA®=j H UM PAD M K WL N 20V R•b & itNNE10 RApUB s ro AOCOYWAIE LUMBER 711103 a 10 EE PMVM 0. 00AMMM 9NBut K IOEAIM 10 PRO,CE fOR mia" UERANON BY AL 0061liltw I 11111)(33, D, 41151 BE WNINim N A OOEx11ON NO ILL PRIDW WA M at DOW FIN OF 7WRC WM 3mm PERNEIC 1111, 1:0E9911011N1 am NLL EE IEAm".. MP =11 Ol "a L ANY MAMK WNW ERft MA20E IT 0170 11E ROAD WBT i aWm II•EOAIELY. 16 Construction Entrance Scale: Not To Scale: I.- 2•-e'�BA1N16kPfZER. ContrWiWn lolnrs ShOU. he pleatd at M' int.rYOU. Wh. }pin, ,Paatag of eatah Dwain B.-in sAOB a. 5'. WherA 10, Curb s.Oltw, ale required )a be r Aa, .'finer ramova & replacs the "fire ),Im ar I. sW & doss, A mPdnwm of 5'- of a Yb to M.."t rerawaiv mffort. 2. .toIm tpasing may Us. Rowse if '040114 by t+. city FAQUHtr 3. Canrresti.A to it n be .IR4004 by Me a- at t,mpfoMS W fWANNI by ellier aaprm,e m.fh.A. Where .t.h jairds are e l farmed by bmPjf a, , mfNmwa "aNt of. 1 1y2 ,hail DR .b alAto.. 4 Mt c"ySfn,RUort pint shalt M rifted with joint tifer am has appDyd: jafot ,Rate': See RRseTfcaiians section -0BMO0. 5. £xponsron [aims tHao as spaced at SO' INr.H,, mW adjacem to ail rlow obt.vif. 6 Ca P"'t. I. ba a ,imm.m at SAW -P51 • M days: at, "rr,A d. t. Ste°. jdhia >HtDn li.kfilfiag or pafarmtng a�OR.n! apNatipAf.. 1 TYPICAL CURB AND GUTTER 1 G Sete: Not To Scale: 24 STOP POST O 7'-6„ OD N FENCE TO MEET TOWN STANDARDS O O TT DOUBLE GATE W/ WHEEL SUPPORTS i � I i —6" REINFORCED CONCRETE PAD - 3000 P.S.I. A ASPHALT PAVEMENT PLAN NOTE: 6X6/6-6 STOP POST AND FRONT STEEL MESH BOLLARDS SHALL 6" STEEL PIPE, CONCRETE FILLED. THE EXPOSED �LEI LENGTH SHALL BE 4' ABOVE Co —#6 BAR GROUND WITH A BURY `rl f DEPTH OF 3'. POSTS SHALL • y VERTICALLY LEVEL IN AN 18" DIAMETER HOLE BACK R WITH 3000 PSI CONCRETE. 6" AGGREGATE g° I BASE COURSE SECTION A —A 17 DUMPSTER PAD DETAIL Scale: Not To Scale: w 0 Q =`-SEAL` - 20212 ?= �"'4IPHLO�.��``. �{IBa11/IBt\\\\ 'NV 1�0 =Vr'INFFRrVr RVIC-S, ' 10 lr_FHc Vn, P-C�z(, PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 27889 252-945-2983 pespReCembargmaN.corn N Z 0 Q O 10008 Scale: NTS Sheet No. Ciill,,o0031 -- 1 IT r7I ! Ti,T 1 dT, 1 17 r-- Ir { l II. I I jl ..t i 'N r t ii It ll I.�Ny ,,•il ti