HomeMy WebLinkAboutSW7100904_APPROVED PLANS_20110131STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE &o l 3 YYYYM M D D m SITE PLAN OF PIN: 6992-00-12-3838 GREATER WELCH'S TOWNSHIP 2, MIDDLE 1. THE ONSITE PAVEMENT DESIGN SHALL BE: 2.0" SP 9.5 BITUMINOUS CONCRETE 7" ABC STONE (COMPACTED TO 98% PROCTOR) COMPACTED SUBGRADE PARKING LOT SUBGRADE SHALL BE COMPACTED TO ASTM-D 698 AND PROOF ROLLED TO DETERMINE STABILITY. IF PUMPING OCCURS, SUBGRADE TO BE EXCAVATED AND BACKFILLED WITH SELECT FILL (MINIMUM CBR 20). SPECIAL NOTES: 1. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL UTILITY RELOCATIONS. 2. ALL PRIVATE UTILITY (IE. GAS, ELEC., COMM.) SERVICES SHALL BE INSTALLED UNDERGROUND. 3. THE WATER CONNECTION TAP AND METER INSTALLATION WILL BE PERFORMED BY THE COUNTY OF CHOWAN AT THE OWNERS/DEVELOPERS EXPENSE. COST FOR THIS WORK WILL BE PAID TO THE COUNTY OF CHOWAN. THIS MUST BE COORDINATED WITH THE UTILITIES DEPARTMENT. 4. SEPARATE PERMITS ARE REQUIRED FOR FENCES, SIGNS, AND FLAGPOLES. ■ CHAPEL BAPTIST CHURCH 3250 VIRGINIA ROAD CHOWAN COUNTY, NORTH CAROLINA NOTES AND SPECIFICATIONS GENERAL NOTES 1. ALL CONSTRUCTION, INSTALLATION, MATERIALS AND METHODS OF PRACTICE SHALL CONFORM WITH THE CURRENT SPECIFICATIONS AND STANDARDS OF THE DEPARTMENT OF PUBLIC WORKS, COUNTY OF CHOWAN, NORTH CAROLINA AND NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. COUNTY CONSTRUCTION STANDARDS AND TECHNICAL SPECIFICATIONS ARE SET FORTH IN THE PUBLIC FACILITIES MANUAL. A COPY OF EACH MUST BE ON SITE AT ALL TIMES. 2. ELEVATIONS AS SHOWN HEREON ARE BASED UPON COUNTY OF CHOWAN DATUM (NAVD 88). 3. PRIOR TO CONSTRUCTION OR EXCAVATION, THE CONTRACTOR SHALL ASSUME THE RESPONSIBILITY OF LOCATING ANY UNDERGROUND UTILITIES (PUBLIC OR PRIVATE) THAT MAY EXIST AND CROSS THROUGH THE AREA OF CONSTRUCTION THAT ARE NOT SHOWN ON THESE PLANS. UTILITY COMPANIES SHALL BE NOTIFIED 48 HOURS IN ADVANCE OF ANY EXCAVATION IN THE PROXIMITY OF THEIR UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS EXPENSE, ANY UTILITIES DAMAGED DURING CONSTRUCTION, PRIOR TO EXCAVATION, CALL ULOCO TO LOCATE UTILITIES AT 800-632-4949. 4. THIS PLAN DOES NOT GUARANTEE THE EXISTENCE, NON-EXISTENCE, SIZE, TYPE, LOCATION, ALIGNMENT OR DEPTH OF ANY OR ALL UNDERGROUND UTILITIES OR OTHER FACILITIES. WHERE SURFACE FEATURES (MANHOLES, CATCH BASINS, VALVES, ETC.) ARE UNAVAILABLE OR INCONCLUSIVE, INFORMATION SHOWN MAY BE FROM UTILITY OWNER'S RECORDS AND/OR ELECTRONIC LINE TRACING, THE RELIABILITY OF WHICH IS UNCERTAIN. THE CONTRACTOR SHALL PERFORM WHATEVER TEST EXCAVATION OR OTHER INVESTIGATIONS NECESSARY TO VERIFY TIE-IN INVERTS, LOCATIONS AND CLEARANCES, AND SHALL REPORT IMMEDIATELY ANY DISCREPANCIES, 5. PRIOR TO CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS FROM THE COUNTY OF CHOWAN. 6. TEMPORARY DRAINAGE DURING CONSTRUCTION TO BE PROVIDED BY THE CONTRACTOR TO RELIEVE AREAS THAT MAY CAUSE DAMAGE TO ROADWAYS, AS DIRECTED BY THE DEPARTMENT OF PUBLIC WORKS, COUNTY OF CHOWAN. 7. ALL CONCRETE TO BE CLASS "AY AIR ENTRAINED 000 PSI). (3, S ). 8. ALL STORM SEWER PIPES SHALL BE CONCRETE. PIPES NOT SUBJECT TO TRAFFIC LOADING MAY BE NON -REINFORCED PIPE AND SHALL CONFORM TO THE SPECIFICATIONS FOR CONCRETE SEWER PIPE ASTM C14, CLASS II. PIPES SUBJECT TO TRAFFIC LOADING SHALL BE REINFORCED PIPE AND SHALL CONFORM TO THE SPECIFICATIONS FOR CONCRETE SEWER PIPE ASTM C76, CLASS III. THE MINIMUM COVER OVER DRIVEWAY SHALL BE 0.75' (9"). 9. WHEN MATERIALS ARE UNSUITABLE FOR SUBGRADE OR OTHER ROADWAY PURPOSES WITHIN THE LIMITS OF STREET CONSTRUCTION, THE CONTRACTOR SHALL BE REQUIRED TO EXCAVATE SUCH MATERIAL BELOW THE GRADE ON THE PLANS, AND THE AREAS SO EXCAVATED SHALL BE BACKFILLED WITH APPROVED SUITABLE MATERIALS. THE EXTENT OF UNDERCUTTING AND BACKFILLING TO BE DETERMINED BY THE DEPARTMENT OF PUBLIC WORKS. 10. CURBS AND GUTTERS SHALL BE CONSTRUCTED IN SECTIONS OF UNIFORM LENGTHS, APPROXIMATELY 10 FEET, AS NECESSARY TO FORM CLOSURES. PRIOR TO INSTALLATION, ALL ROUGH GRADING MUST BE COMPLETED IN THE RIGHT-OF-WAY. 11. ALL STORM SEWER PIPE, DROP INLETS, AND CURB INLETS SHALL BE CLEANED OF DEBRIS AND ERODED MATERIAL AT LAST STAGES OF CONSTRUCTION. 12. ALL UNDERGROUND WORK SHOULD BE COMPLETED PRIOR TO PAVING. 13. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL SIGNS, MARKINGS AND ROADWAY LIGHTING. 14. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTIFICATION TO ALL OWNERS AND RESIDENTS OF PROPERTY ADJACENT TO A DEVELOPMENT OR OFFSITE IMPROVEMENTS, 30 DAYS PRIOR TO THE COMMENCEMENT OF WORK UNLESS OTHERWISE DIRECTED BY THE COUNTY. CONSTRUCTION WITHIN EASEMENTS OR ON PUBLIC RIGHT-OF-WAY NECESSITATES NOTICE WHETHER ADJACENT TO OR LOCATED ON THE ADJOINING PROPERTY. FAILURE TO PROVIDE THE MINIMUM NOTIFICATION TIME WILL RESULT IN A SUSPENSION OF WORK. 15. ALL EXISTING ON -SITE UTILITIES ARE PRIVATE, NOT COUNTY MAINTAINED. UTILITY EASEMENT TREES, SHRUBS, LANDSCAPE BERMS, ETC. MAY NOT BE PLACED WITHIN THE UTILITY EASEMENT SANITARY NOTES 1. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH THE COUNTY OF CHOWAN REQUIREMENTS. LINE CROSSINGS MUST BE IN ACCORDANCE WITH THE PFM MANUAL. 2. PIPE MAY BE ONE OF THE FOLLOWING MATERIALS: A. PIPE OF PVC, SDR-35 (ASTM-3034), PVC C-900, ABS TRUS (ASTM-D-2751) OR DUCTILE IRON SHALL BE USED. B. OTHER MATERIALS AS PERMITTED IN THE PUBLIC FACILITIES MANUAL VOL. III. 3. SEWER TAP TO BE INSTALLED BY THE CONTRACTOR WITH COUNTY INSPECTION. WATER DISTRIBUTION 1. ALL WATER CONSTRUCTION IS TO BE IN STRICT ACCORDANCE WITH THE COUNTY OF CHOWAN SPECIFICATIONS. LINE CROSSINGS MUST BE IN ACCORDANCE WITH THE DENR STANDARDS. 2. MATERIALS FOR WATER SERVICE LINES ON THE COUNTY SIDE OF THE WATER METER SHALL BE COPPER TUBING TYPE "K". WATER MAINS IN THE RIGHT-OF-WAY SHALL BE DUCTILE IRON (AWWA C-151) OR PVC C-900. MATERIALS FOR WATER SERVICE ON THE DEVELOPER'S SIDE OF THE WATER METER MA'i BE COPPER TUBING TYPE "K", PVC C-900 OR DUCTILE IRON. 3. ALL WATER LINES SHALL HAVE A COVER OF THIRTY-SIX (36) INCHES. 4. WATER AND SEWER LINES SHALL BE SEPARATED BY A MINIMUM OF TEN (10) FEET HORIZONTALLY FOR PARALLEL INSTALLATION AND EIGHTEEN (18) INCHES VERTICALLY WITH WATER ABOVE THE SEWER FOR CROSSOVERS. 5. WATER SERVICE MUST BE EQUIPPED WITH AND APPROVED REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER. THE PREVENTER MUST BE INSTALLED ON THE WATER LINE IMMEDIATELY DOWNSTREAM OF THE WATER METER, ON THE CUSTOMER'S PROPERTY OUTSIDE OF ANY EXISTING OR PROPOSED PUBLIC UTILITY EASEMENTS ACCORDING TO MANUFACTURE'S INSTRUCTIONS AND INTERNATIONAL PLUMBING CODE REQUIREMENTS. PREVENTER MUST BE INSTALLED A MIN. 12" ABOVE GRADE IN A STRUCTURE TO PROTECT THE DEVICES FROM WEATHER, SUBMERGENCE, VANDALISM, ETC. AND INSTALLED IN AN EASILY ASSESSABLE LOCATION. PREVENTER MUST BE TESTED BY A CERTIFIED TECHNICIAN AND DOCUMENTATION ONSTRUCTION SEQUENCE 1. INSTALL CONSTRUCTION ENTRANCE 2. INSTALL EROSION PROTECTION MEASURES 3. INSTALL STORM DRAINAGE 4. ROUGH GRADING 5. FINAL GRADING AND INSTALL SIDEWALKS 6. INSTALL LANDSCAPING 7. REMOVE TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES SITE STATISTICS OWNER GREATER WELCH'S BAPTIST CHURCH 3250 VIRGINIA ROAD TYNER, NC 27980 PHONE: 252-221-4058 DEVELOPER: S CONCEPTS C/O HAROLD BARNES P.O. BOX 517 EDENTON, NC 27932 PHONE: 252-267-6134 LEGAL REFERENCE: DBH/126 PIN #: 6992-00-12-3838 SUBJECT PROPERTY IS IN FLOOD ZONE "X" MAP # 3720698200K DATED: JULY 20, 2009 DRAWING INDEX 1. COVER SHEET 2. SEDIMENTATION AND EROSION CONTROL / DEMOLITION PLAN 3. SITE PLAN 4. LANDSCAPE PLAN 5. NOTES AND DETAILS 6. NOTES AND DETAILS LEGEND EXISTING PROPOSED FLOOD ZONE INFORMATION SHOWN HEREON IS SCALED FROM F.I.R.M. (F.I.R.M. MAPS ARE AT APPROXIMATE SCALE) AND DOES NOT IMPLY THAT THE PROPERTY WILL OR WILL NOT BE FREE FROM FLOODING. FOR FURTHER INFORMATION, CONTACT THE COMMUNITY FLOOD OFFICIAL IN THE AREA. CAE, INC., IS NOT RESPONSIBLE FOR DETERMINING THE REQUIREMENTS FOR FLOOD INSURANCE ON THE SAID PROPERTY SHOWN HEREON. PROPOSED BUILDING FOOTPRINT TO BE CONSTRUCTED: 11,498 SQ.FT. (0.26 ACRE) SUBJECT AND ADJACENT PROPERTY ZONED: R-6 (TO BE REZONED 1-2) PLANNING DEPARTMENT REFERENCE USE: CHURCH ZONED: Al SITE AREA: 172,688 SQ.FT. / 3.96 ACRES EXISTING IMPERVIOUS AREA: 10,592 SQ.FT. (0.24 ACRE) EXISTING BUILDING FOOTPRINT: 7,839 SQ.FT. (0.18 ACRE) EXISTING CONCRETE AREA: 2,753 SQ.FT. (0.06 ACRE) 1Qp 103 *a `,r I y r t 7 o VICINITY MAP - SCALE 1"=3000' BITUMINOUS CONCRETE PAVEMENT OR CONCRETE PAVEMENT SPOT ELEVATION CONCRETE CURB STORM DRAIN POWER POLE SILT FENCE DIVERSION DIKE TEMPORARY CONSTRUCTION ENTRANCE COURTESY: USGS Owl* INLET PROTECTION V_ /� f.t awe 10A, j cla SEDIMENT TRAP is dt A+ : e+ GA a I t SEDIMENT BASIN i �I PERMANENT SEEDING G $4 • w w jk Co. TREE PROTECTION EROSION CONTROL IMPERVIOUS AREA PROPOSED: 77,128 SQ.FT. (1.77 ACRES) CONSTRUCTION PLAN ASSIGNMENT TOTAL PROPOSED BUILDING FOOTPRINT: 18,054 SQ.FT. (0.41 ACRE) RE: SITE PLAN FOR GREATER WELCH'S CHAPEL BAPTIST CHURCH PROPOSED CONCRETE WALK: 5,509 SQ.FT. (0.13 ACRE) PROPOSED ASPHALT PAVEMENT: 53,565 SQ.FT. (1.23 ACRES) THE UNDERSIGNED ENGINEER/FIRM AGREES THAT THE COUNTY OF CHOWAN AND/OR TOTAL LOT COVERAGE: 44.67% STATE OF NORTH CAROLINA SHALL HAVE THE RIGHT TO USE THESE PLANS TO COMPLETE THE PERMANENT PHYSICAL IMPROVEMENTS IN THE EVENT THAT THE DEVELOPER DEFAULTS PERVIOUS AREA PROPOSED: 95,560 SOFT. (2.19 ACRES) IN HIS OBLIGATIONS TO COMPLETE THESE FACILITIES AS REQUIRED BY THE COUNTY CODE. IMPERVIOUS AREA PROPOSED: 77,128 SOFT. (1.77 ACRES) THE UNDERSIGNED ENGINEER ALSO AGREES THAT THE COUNTY MAY USE THESE PLANS FOR TOTAL DISTURBED AREA: 105,974 SQ.FT. (2.43 ACRES) 'AS -BUILT" RECORDS AS NECESSARY. THE ENGINEER/FIRM FURTHER AGREES THAT THESE RIGHTS TO USE THE PLANS SHALL BE PROVIDED WITHOUT COST TO THE COUNTY. BUILDING HEIGHT: 35' MAX. (PER CHOWAN COUNTY ZONING SECTION 6.01) NAME: HOLLIS D. ELLIS, P.E. BUILDING CONSTRUCTION: NC BUILDING CODE (TYPE III) PARKING REQUIRED:,/;, ONE SPACE PER EVERY FOUR SEATS IN MAIN CHAPEL SIGNATURE: �'LSWV� �G DATE: 12$ tl 398 FIXED SEATS HOLLIS D. ELLIS, P.E. = 100 PARKING SPACES 1 SPACE PER 4 SEATS PARKING PROVIDED: TOTAL NUMBER OF EXISTING PARKING SPACES: 0 TOTAL NUMBER OF PARKING SPACES: 103 NUMBER OF REGULAR PARKING SPACES: 98 NUMBER OF HANDICAP PARKING SPACES: 5 BUILDING WILL NOT BE EQUIPPED WITH SPRINKLER SYSTEM FIRE ALARM TO BE INSTALLED DOMESTIC WATER DEMAND: COMBINED FIXTURE VALUE = 160 (USING AWWA) DEMAND = 55 GPM. USE 2" DOMESTIC METER STORMWATER RUNOFF (Q10 VALUES) PRE -DEVELOPED FLOW = 5.66 CFS (CN 71; 55.8 MIN TC) POST -DEVELOPED FLOW = 0.27 CFS (CN 84, 20.0 MIN TC) _1AN 2 5 ?011 A r NORTH CAO A F y'Rt N"EN s,, MAMA: ;;:1h" SSION VrA i ER QUALITY CALL ULOCO TO LOCATE UTILITIES BEFORE YOU DIG 1-800-632-4949 zzz w w 0 0 0 0 w 0 n - m o U) Z O V) Z w O O 7 Ld Z Z Z a a a mw ' 0 x 5. X Q L� o x M � O O T C° � O N N I rn W d y z LJ F N I- (,4 o • Q � w x (-� C Z N In Lli j.�♦ W - O z U)LLI � v Y o Q CT 7 O w (� U N O w Q Q Lo W Ld w w Y mL0 I m 3 z as N e o Z O Cr 7 llj Z W �> O W ¢ Ld o U x U M� W Inn U z E a W c co E.I mcc Wr�l o cat V W Ft4O O W V 1 Q O a O N W SHEET 1 OF 6 N/F JAMES ROBERT HENDRDI 34 6 0 -315 D.B. 1 PG. 4 ' _ PARCEL ID: 6992-00-14-7654- 33.77 ZONED: Al 30 25 34 60 3413 \ ------34- - - - - -- ^� V4o-BSL 35•Cf7/ 97 34.32 343 4 I 1 N/F JOSEPH H. WARD D.B. 192 PG. 224 PARCEL ID: 6992-00-42-3489 ZONED: Al 37 - 341 _ 3333 -_ - - - 7 Q _ 32t5 �� jkl �33�"_- 3Z,3 33' 33--_. SF -32-__ ��1.45 3 -3L'�4 -<3�3 9 41 1 33. ------- PD ---� Bt 97 32. 32j � SF - - - - - - - - - - - - - - - - - - - - - - - - _ f �\ - - - - - - - - PD \\ \ 4\q� \ 3 2 I \35 \ 3339 �/ / \\` `\\ �\ \33.0 \ 32. 9 /��� \ \ \1.0 32 33y4 ' / / �9'0 300 \\ 2�� 28.0 \\ \\ \ •/ 1 PD sF 35.20 , p /\R,`\ \\ 33 \\SF I \ 50 f \ 34.9() \ I SF PD I If \ r ) 35,26 s 35 62 35.58 \4 3-734.46 I 351,56 65 I VIRGINIA ELECTRIC POWER COMPANY �I 35 69 I I \ -. 70 3 5 74 D.B. 11 PG. 363 411 36 5 90 3 PARCEL ID: 6992-00-13-4029 00 _ ZONED: Al 71 51 EXISTING co / I 35k CHURCH 3a. I 3 74 F F. = 39.53 4� \ I o 07 53 41 I x w 35 9 37.25 I 36- I DENOTES CONCRETE, ' I � � 6` ° EXISTING 35 57 GRAVEL, AND ASPHALT SF CHURCH TO BE REMOVED � FF. 39.15 5 I( \ 36 8 3 5 I 3616 I 1 6 66 /// 30 32 5 2 /) 35 37.6a 36 as / PS 3-716 16 9 7 ' . 3 . 3 C1 IP - 36+- --------- 35:7� 3� / 3g. SF 69 a 35 �M/ EX CHURCH SIGN / z 3 1 (TO BE RE�ICATED) APPROXIMATELY 440' ` ` 36 36 38 o C STATE ROUTE 1305 (RYLAND 6ROAD) - - 6 2 PS -\ B1 6.24 OU 5935 EX 10 cD 7 35� 00 33 71 \ OD \ \ 3404\ NCDOT STD, 840.01 W/O GRATE AND HOOD Qo /INV 26.45 3418 \ -'_-� \ �(\ 3 9 SF 33.2a \ 33 -76 33 / ----- \ �l � � 34,32 / \ , k-7 4 , L0 3313 \� I SF 1 O 00 33.56 32-L. ll.51 3 \ 419� � 2 3474 1 " 33.83 ' 52 3314 32. 6 4 9� 34 g6 33,9_� - 33?1 �15 O I ' e -3 -5 \ 32 p2 I, 3 3 Z \ 6 58S 34.48 33 84 33.55 3 L fi 9gg .. 31. g7 32 IP 33." �, IP I 33. 33 9 O ' O I ' 97 A2 , 34 81 34.34 A4 tt 3 3� 31�.79 III , x 35.32 76 I z' I \ 33.40 I _ Cg ' 34.69 Imo' v' I � � D� I PS II 35?7 / 34 52 ' 35. 0 34.2 0 33 42 I Ts 67J' 33 35.21--\�---------4------ ---------- - - - 50BSL \ \ / 3465-- 336�-� --- \ ' / 3436 \ // I SF 65 i 33. 34 ].63 - - ------'--- 33 g4 35 ° IEAIBAN�, NED) IP 3/4 W 34, 11 34.56 54. 29 638"E PS -34 a0 34 66 - - - - 0 84' as - - - - Ps o - �- - 6 Ex to"W - v 36 73 36 76 365g 36 39 336-Ql 35 �9 35,60 NC STATE ROUTE 32 (60' R/W) GRAPHIC SCALE f 100 N/F JOSEPH H. WARD D.B. 192 PG. 224 PARCEL ID: 6992-00-42-3489 ZONED: Al STORM SEWER SCHEDULE Al B7 Cl NCDOT STD 840.14/840.03 23"X14" FLARED END SECTION NCDOT STD 840.14/840.03 RIM 36.10 INV 35.55 RIM 36.28 INV 32.50 61 - 62: 48'-23"X14"HECP®0.21% INV 35.41 Al - A4: 119'-18"RCP®0.26% Cl -. OUT: 72'-10"PVCOO.10% B2 A2 23"X14" FLARED END SECTION NCDOT STD 840.14/840.03 INV 35.45 OUT(C� RIM 35.74 INV 3 .34 INV 32.55 82 - B3: 143'-DITCH01.36% A2 - A4: 137'-18'RCP®0.26% g FLARED END SECTION A3 INV 33.50 NCDOT STD 840.14/840.03 RIM 36.25 63 - 64: 52'-18"RCPCD0.40% INV 32.59 64 A3 - A4: 91'-12"RCP@0.44% 18"FLARED END SECTION INV 33.30 A4 NCDOT STD 840.14/840.01 64 - 65: 129'-DITCH®0.42% RIM 35.14 INV 32.19 1B8'FLARED END SECTION A4 - A5: 92'-24"RCPC O.17% INV 32.76 A5 NCDOT STD 840.14/840.03 B5 - B6: 56'-18"RCP®0.47% RIM 35.29 INV 32.03 (W) BS'FLARED END SECTION INV 28.08 (E) INV 32.49 A5 - OUT: 56'-27"RCP®0.15% 66 -OUT: 49'-DITCH01.06% OUT27 A END SECTION OVJTW NV 2800 15D RA END SEC110N W/ ( RIP -RAP 3 CY) INV 32.01 INV 30.00 (TEMP) INV 28.00 51 -----� 1 RAR6E6 END SEC110N W/ RIP --RAP (3 CY) INV 32.01 35-46 3535 35.26 .,c A4 w O V w g O U w O U 0 a - N Z 0 W W OU 7 U z cr z z a ° a i ono _:•� - � i w r V' • - X Q L� w o x V) C)7 CD m CD NLli I rn z Ld t N N • z :D (.0 T 1 Q n d w ox J 1= N zQ L0 r - x m 1�1 Fri W U Z Y z who �Q U> O U WU) ��� Q Q LLI LL1 w w Y m m 3 tf) z Q Q N z O (D Lil Z 3 LI_J > O S a- Ld Q J in 0 0 U a V O z x U pE, w co Ch H O A Ua� d w •' Z O Z a c W E-I-I d 0-4 SHEET 2 OF 6 N/F JOSEPH H. WARD D.B. 192 PG. 224 A 1101I cn v (® •42 t333 m 33-6� I I SOIBSL fi.73: 36,�Z3 I I ETC 36.96 g3 �34 68 � l 3- 33.5� 33 94ZZA M ►I 7 / 33 8�33 _ t �R 80 N/F JOSEPH H. WARD D.B. 192 PG. 224 PARCEL ID: 6992-00-42-3489 ZONED: Al STORM SEWER SCHEDULE Al B1 Cl NCDOT ST- 840.14/840.03 23"X14" FLARED END SECTION NCDOT STD 840.14/840.03 RIM 36. o� INV 35.55 RIM 36.28 INV 32.50 B1 - B2: 48'-23"X14"HECP@0.21% INV 35.41 Al - A4: 119'-18"RCP(�0.26% Cl - OUT: 72'-10"PVCOO.10% B2 A2 23"X14" FLARED END SECTION NCDOT STD 840.14/840.03 INV 35.45 OUTCC RIM 35.74 INV .34 INV 32.55 B2 - B3: 143'-DITCHO1.36% A2 - A4: 137'-18"RCPCd0.26% 18 FLARED END SECTION A3 INV 33.50 NCDOT STD 840.14/840.03 RIM 36.25 B3 - B4: 52'-18"RCPOO.40% INV 32.59 B4 A3 - A4: 91'-12"RCP®0.44% 18"FLARED END SECTION INV 33.30 A4 NCDOT STD 840.14/840.01 B4 - B5: 129'-DITCH®0.42% RIM 35.14 NV 32.19 18 FLARED END SECTION A4 - A5: 92'-24"RCPDO.17% INV 32.76 A5 NCDOT STD 840.14/840.03 B5 - B6: 56'-18"RCP®0.47% RIM 35.29 INV 32.03 W) (E) %, FLARED END SECTION INV 28.08 INV 32.49 A5 - OUT: 56'-27"RCPOO.15% B6 -OUT: 49'-DITCH@1.06% 7T(% 2ED END SECTION OUT(B) INV 28.00 15"FFlLAAIEUU END SEC110N W/ RIP -RAP (3 CY) INV 32.01 98 105 FUIRBED END SEC110N W/ RIP -RAP (3 CY) INV 32.01 35 35 35'26 Z O_ cn W X Q w V) rn m o� N N � o+ LLJ y z W N N o • Q Nj o x J (`7 Q W — U Z O v Y � z w 0' rl) U •� Q > > O w U � w Q Q w w w Ld Y Cif m i Z Q Q Ln N _ Oz o` O CDZ of LJ Z W �> O = = N W Ln H o U U aO � � v 1H w c co Fri a O N U W w a c U a 0 cil x � a a c d d w a E SHEET 3 OF 6 0 I 1 I 1 7 3? 68 ' 47 t` H) If 37 37 A9 / 3717' APPROXIMATELY 440' TO NC STATE ROUTE 1305 (RYLAND ROAD) 38- 6.% c� i6 35 zKP(`)) 6 35 9 36 53 3675 3636 36 26 33 I 36.16 - ��pp- +5I�J1■_ 59 IO' ROADSIDE BUFFER Y EX 10"W KP(3) 3 IC(37) 36 58 36.15 N/F JOSEPH H. WARD D.B. 192 PG. 224 PARCEL ID: 6992-00-42-3489 ZONED: Al LJ t r.M'f Nl[ 36_91 3579 NC STATE ROUTE 32 (60' R/W) GRAPHIC SCALE ( IN FEET ) 1 inch = 25 ft_ LI(6) 6� 10' ROADSIDE BUFFER YARD 3a36 KP(3) 3625 IC(37)' 35 6C DENOTES AREA OF ENGINEERED FILTER STRIP (SEE FERTILIZER APPLICATION, SHEET 6 OF 6) 35.46 35.35 35.76 PLANT SCHEDULE 00� gyp`, 0�� yyen yen �J� SIZE COMMON NAME BOTANICAL NAME HEIGHT COMMENTS KP 8 2" - 2 1/2" CAL. GOLDENRAINTREE KOELREUTERIA PANICULATA 8' MIN. HT PM #6 & B - 61 O.C. 1 LI 32 1" - 1 1/2" CAL. TUSKEGEE CRAPE MYRTLE LAGERSTROEMIA INDICA 8' MIN. HT BM&�,B ` = s ZS 9 2 1/2" - 3" CAL. GREEN VASE ZELKOVA ZELKOVA SERATA 12' - 14' HT. B & B 'Green Vase' PM # 1 { IC 94 30" - 36" (MIN.) BURFORD CHINESE HOLLY ILEX CORNUTA 36" MIN. HT B & B - 4' O.C. 'Burfordii' 30" SPREAD PM # 2 LJ 47 18" - 24" (MIN.) JAPANESE PRIVET LIGUSTRUM JAPONICUM 36" MIN. HT B & B PM #2 SLF 356 4.5 CF PER CONTAINER SWAMP SUNFLOWER HELIANTHUS ANGUSTIFOLIUS 4.5 CF PER CONTAINER SHALLOW LAND FLOWERS PLANTING AT S O.C. (1 PER 2 SF) SLG SAWGRASS CLADIUM JAMAICENSE PIANTNC AT 3. OC (i PQ2 2NSF) 830 4.5 CF PER CONTAINER SIMTCHGRASS PANICUM VIRGATUM 4.5 CF PER CONTAINER SPEDES SHALL � RANOOiCIIMALY PLAN7B1. WOOL GRASS SCIRPUS CYPERINUS AT 277 UNITS PER SPECIES SWEET FLAG ACORUS AMERICANUS SHALLOW WATER PLANTS :•:• SWP 410 4.5 CF PER CONTAINER ARROW ARUM BULLTONGUE PELTANDRA VIRGINICA SAGITTARIA LANCIFOLIA 4.5 CF PER CONTAINER PLANING AT 4- O.C. (1 PER 4 $F) SOUTHERN BLUE FLAG IRIS IRIS VIRGINICA SPECIES SHALL BE RANDOMLY HAPLANTED WATER MILLET ZIZANIOPSIS MILIACEA AT 82 UNITS PER SPECIES m N/F JOSEPH H. WARD D.B. 192 PG. 224 PARCEL ID: 6992-00-42-3489 ZONED: Al PdL� 0 $ E I�9 .��wee fie® ®��-p----p1p - PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH THE • DO NOT OVERTIGHTEN GUY WIRES. 6 ALLOW SUFFICIENT SLACK PERMIT ® 0 DE E �� g®� 2" LATERAL TRUNK MOVEMENT IN �•u®[ „p� y� ALL DIRECTIONS - )A �A05 J�"-e� STAFINIKE FIRST BRANCHES OR AS NECESSARY FOR DESIRED ! ♦ • RUBBER HOSE SECURED WITH N! i pt��A �® j SUPPORT GAUGE PLIABLE GALVANIZED �a 6 AFTER INSTALLATION. CUT STAKE M WIRE - ®! %0AW0 % SQUARE 3" ABOVE WARE ®Y t fA MINIMUM BRANCH HEIGHT AA.N. STANDARD • HARDWOOD STAKES 2 EVENLY SPACED STAKES (2" X 2") DRIVEN (MIN. 180 FIRMLY 3" MULCH (MINIMUM DEPTH) INTO SUBGRADE PRIOR TO 3ACKFILUNG nR. ENTIRE SAUCER-- (WIIHHOLD 6" FROM TRUNK) • COMPACTED EARTH SAUCEF _FINISHED GRADE • UNAMENDED SOIL - WATER & TAMP TO - PLANTING BACKFILL REMOVE AIR POCKETS ( ) MIN. 12' ALL SIDES • UNDISTURBED EARTH ° CUT & REMOVE TOP 1/3 OF BURLAP, NOTE: LACING AND WERE BASKET AFTER PLANTING PITS IN SUBSTANDARD SOILS PLACEMENT. LEAVE BALANCE INTACT SHALL PROVIDE MINIMUM 2• WIDE BACKFILL OF PREPARED SOIL MIXTURE ON ALL SIDES 2 X BALL DIA OF ROOT BALL TREE PLANTING METHOD (NOT TO SCALE) • PLANT SO THAT TOP OF ROOT WHERE A SHRUB BED OCCURS THE BALL IS EVEN WITH THE ENTIRE BED SHALL BE BACKFILLED FINISHED GRADE t�" WTH REARED SOIL MIXTURE AS SPECIFIED3" MINIMUM DEPTH SHREDDED HARDWOOD MULCH OVER EN71RE BED/SAUCER. WITHHOLD FROM 'O o CROWN FINISHED GRADE o •.f COMPACTED EARTH SAUCER CUT & REMOVE TOP 1/3 OF BURLAP. UNAMENDED SOIL - qNG AND WIRE BASKET AFTER WATER & TAMP TO PLACEMENT. LEAVE BALANCE INTACT REMOVE AIR POCKETS PLANTING BACKFILL -MIN. 2 TO 3 TIMES THE SIZE NOTE OF ROOTBALL, ALL SIDES UNDISTURBED EARTH PLANTING PITS IN SUBSTANDARD SOILS SHALL PROVIDE MINIMUM 18" WADE BACKFILL i 2 X BALL DIA , OOf F ROOTRED SOIL MIXTURE ON ALL SIDES 2 SHRUB PLANTING METHOD (NOT TO SCALE) II �ON ALLOR SIDES — USENGATE ONEFRONTPSIDE II 6"x6"—W1.4xW1.4 WWFJ 6" AGGREGATE BASE 6" CLASS A-3 3000 PSI 8" COMPACTED SUBGRADE APRON DUMPSTER PAD DUMPSTER PAD NOT TO SCALE m n E 0 U x Q LL 41 CDI V / 0) 0 O DO N N LL O 1 N (V o LLB z LJ l C,4 r CA o z \J� Q (n V F-� Z N L Lc) r F� w - cn 7 cn Y Z w [if _ 'd- U W C/, U) N Q Q un W LJY W LMJ °� I i m i L` z Q Q (V 0- O Z CD �l Q (D z LLJ > O CL LLJ a -J W � o in O O x U t�U rl z a pEp.� d w M co c� QI 1-a G: I tit V W �Or E+ O O :ai 0.W L\2 o A94 a WW O W C'3 E E SHEET 4 OF 6 �P SILT FENCE DROP INLET PROTECTION 2 X 4' WODD FRAME DROP INLET WITH GRATE 1.5' MAX. FRAME 3' MIN. U GATHER U ��ti EXCESS �� AT CORNERS �� /� PERSPECTIVE VIEWS 1' MIN. IIII� ELEVATION OF STAKE AND 1, FABRIC ORIENTATION DETAIL A SPECIFIC APPLICATION THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET BRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE THE INLET SHEET OR OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS. 70' (MIN.) MOUNTABLE EXIST. EXIST. GROUND, 6" (MIN.) -I (OPTIONAL) BERM _ 3 . 5:1 `PAVEMENT FILTER CLOTH) I (SEE NOTE #2) SIDE ELEVATION 12' (MIN., SEE NOTE #1) REINFORCED CONC. 6•_7* WASHRACK 3" (MIN.) II- 3" (MIN.) FILTER CLOTH (SEE NOTE #2) SECTION A -A FILTER CLOTH --'DRAIN SPACE / /�� (SEE NOTE #2)//\//\//\ 70, (MIN.) NOTES: SECTION B-B VDOT #1 COURSE AGGREGATE 1. MUST EXTEND THE FULL WIDTH OF!! 7A INGRESS/EGRESS OPERATIONS I WASHRACK I 2. FILTER CLOTH SHALL BE TREVIVA SPUNBOND 1135, 'O (OPTIONAL) I I z MIRAFI 60OX OR EQUIVALENT. o r I N (M .) rw w z B B I I - POSITIVE DRAINAGE TO I z CONSTRUCTION ENTRANCE DETAIL SEDIMENT TRAPPING DEVICE \ A NOT TO SCALE PLAN VIEW CONSTRUCTION SEQUENCE 1. OBTAIN PLAN APPROVAL & ALL PERMITS 2, HOLD PRE -CONSTRUCTION MEETING ONE WEEK OR MORE PRIOR TO THE START OF CONSTRUCTION. 3. DO NOT BLOCK DRAINAGE. WHEN NECESSARY INSTALL CULVERT IN CONJUNCTION W/ INLET/OUTLET PROTECTION WHILE INSTALLING THE TEMPORARY CONSTRUCTION ENTRANCE. 4. INSTALL SILT FENCING AND TEMPORARY DIVERSION DIKES IN AREAS AS SHOWN ON PLAN, AND OTHER AREAS AS REQUIRED TO PREVENT SEDIMENTATION IN WETLAND AREAS IF ANY. 5. EXCAVATE TEMPORARY SEDIEMENT BASIN TO REQUIRED INVERT AND INSTALL OUTLET RISER AND SKIMMER TO INVERT AND RIM ELEVATIONS AS SHOWN. 6. CLEAR AND GRUB IMPERVIOUS AREAS, REMOVING TREES, VEGETATION, ROOT AND OTHER MATERIAL FLARED END SECTIONS I scum TLC. 1iM PUTS &09-1 THAT MAY AFFECT BUILDING AND/OR PARKING LOT STABILITY. PROJECT NOTES: 7. INSTALL CULVERTS, DROP INLETS (AS REQUIRED),AND CONSTRUCT SWALES & DITCHES. MAINTAIN MINIMUM SIDE SLOPES AS SHOWN IN DETAILS. 1) Owner & Developer: GREATER WELCH'S CHAPEL BAPTIST CHURCH 8. CONSTRUCT STONE SILT (CHECK) DAM AS REQUIRED TO BREAK HIGH VELOCITY FLOWS, PLACE CLASS 3250 VIRGINIA ROAD A STONE RIP -RAP AT ALL CULVERT OUTLETS. PROTECT CULVERT ENDS WITH FILTER CLOTH AS REQUIRED. TYNER, N.C. 27980 PHONE:757-221-4058 9. ALL DISTURBED AREAS MUST HAVE TEMPORARY VEGETATION IN PLACE WITHIN 21 DAYS OF LAND DISTURBANCE. PIN # 6992-00-12-3838 2.) Survey Data provided by BEN PURVIS, PLS 10. CONSTRUCT PARKING LOT AND BUILDING FOUNDATION, UNDERCUTTING AND REPLACING UNSUITABLE SOILS WITH SELECT FILL. 2004 B EAST 3RD STREET (MIN CBR 20) GREENVILLE, NC 27858 Datum: Horizontal- NAD83 11. COMPLETE FINAL GRADING, TOPSOIL CRITICAL AREAS, PERMANENTLY VEGETATE, LANDSCAPE, AND MULCH. Vertical- NAVD88 3. Nearest Receiving Stream: INDIAN CREEK 12, REMOTE AN REMAINING SEDIMENT FROM CULVERTS, STORMWATER STRUCTURES, AND OUTLETS. 4. Soils are Conetoe Loamy Sand, Portsmouth Loam, Tomotley Fine Sandy Loan 5. There are no 404 wetlands on this site. 13. EXCAVATE SEDIMENT BASIN TO AND GRADE TO ESTABLISH TOP OF BANK ELEVATIONS AS SHOWN FOR PERMANENT 6. Watershed Classification: B: NSW STORM 'ATER FACILITY. 7. Total Tract Area = 172,688 sq.ft., 3.96 acres Tt Total Wetlands = ii0 sq.ft., 0.00 acres - ID't bdA 9613 ft 275 11 14 . AFTER SOIL IS STABILIZED, REMOVE TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES. 0 a s ur e rea I sq. . . acres EROSION AND SEDIMENT CONTROL PLAN NOTES PROJECT NARRATIVE: The project is the construction of a residential development containing single family housing Public water is being installed in sections as the real estate is developed and the roads are constructed. Soils in this area have been moped by N.R.C.S. as Conetoe Loamy Sand, Portsmouth Loam, and Tomotley Fine Sandy Loam. SOIL STABILIZATION: All disturbed soils shall be stabilized by seeding and/or sodding within 15 working days or 30 colender days (whichever is shorter) of construction completion or the completion of the land disturbing activity. It is the contractors responsibility to establish a dense ground cover capable of stopping erosion. The Erosion and Sediment Control measures that follow are intended to be minimum standards. When erosion persists other more stringent measures may be necessary to control erosion. Apply fertilizer, and agricultural lime as required by soil test or as a minimum follow this schedule: Apply fertilizer in the amount of 500 pounds per acre of 10-10-10 fertilizer. Apply 2,500 pounds/acre of agricultural limestone. Where possible scarify soil to work the fertilizer and soil into the soil. Mulch the area to be stabilized with wheat straw at the rate of 2 tons/acre. Anchor straw when necessary with netting or asphalt. In some instances it may be necessary to use pre -manufactured erosion control mats like the excelsior mat. Seeding: 1) If Temporary Vegetation is to be established in winter/spring/fall apply 125 pounds/acre of annual rye grain. If Temporary Vegetation is to be established in the summer months apply 25 pounds per acre of Bermuda Grass and 25 pounds per acre of German Millet. 2) Permanent Vegetation shall be established with a mixture of 40 pounds/acre of Bahiagrass, 10 pounds/acre of Bermuda, and 10 pounds/ acre of German Millet. When top seeding over Temporary Vegetation containing a good stand of Bermuda and Millet, only Bahiagrass will be required. 3) Sodding may be required when slope stabilization is difficult to establish. Select a sod species compatible with the application and apply sod strips down the length of the slope. Fasten sod as necessary to prevent slippage. 4) Final slopes in all graded areas shall not exceed a slope of 3:1. 5 Geotextil f should be r e fabrics or special mulch protection ' n such as fiberglass roving or straw and netting sh d provided until vegetation is full P P e tlo 9 9 9 P 9 Y established; this must be used whenever the design velocities exceed 2.0 ft/sec for bare soil conditions. MAINTENANCE: Erosion control devices are to be checked after significant rainfall events but not less than twice monthly. Remove sediment and repair erosion control devices as necessary. Check slopes being stabilized for signs of erosion after all significant rainfall events and repair as necessary. Reseeding and mulching of erosion damaged areas is required. Perform routine maintenance and mowing of stabilized areas, including ditches and swales. Temporary or permanent groundcover shall be provided on all exposed slopes witnin 21 calendar days following completion of any phase of grading; and a permanent groundcover for all disturbed areas within 15 working days or 90 calendar days (whichever is shorter) following completion of construction or development. INTENTION OF THIS EROSION AND SEDIMENT CONTROL PLAN Protect disturbed areas from erosion. Stabilize disturbed areas as soon as possible. Minimize the length of time disturbed soil is exposed. Minimize the velocity of stormwater runoff. Retain sediment on site with silt check dams and silt fencing. SOURCE: VA. DSWC PLATE. 3.20-1 EXTEND THE APRON FILTER FABRIC TO TOP OF PIPE SECTION C-C SPECIFICATIONS: NCDOT 840.01 W/O 840.03 (TRASH RACK OVER OUTLET) RIM 32.00 INV 26.45 N/ TRASH RACK INV 30.00 i i N� DETENTION BASIN OUTFALL STRUCTURE DETAIL (SEDIMENT BASIN OUTFALL RISER STRUCTURE DETAIL N.T.S. \ptz; SKIMMER SIZE = 2" DIA. \ptz; ORIFICE SIZE = 2" DIA. PVC EN' PVC I1. SET PUPSLOPE ALONG WE LINE OF POSTS. TM POPSTS. TRENCHFENCING TO yrx 12-1/2 GAUGE MIN. EXTENSION OF FABRIC AND MESH SPACING WIRE INTO THE TRENCH. 6 MAX. WIRE FILTER FABRIC GROUND LINE STEEL OR WOOD POST -IMBED 3' 4 3. ATTACH WE FILTER FABRIC TO THE 4. SACKFUL AND COMPACT THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. EXCAVATED SUL SOW, 3' MAX PUNTS 'A" SHOULD BE HIGHER THAN POINT 'W FABRIC HEIGHT LESS DRAINAGEWAY INSTALLATION THAN 36• ABOVE GRADE (FRONT ELEVATION) 1EMPORARY SEOIIAENT FENM (W) NOTE: SILT FENCES ARE UTILIZED IN AREAS WHERE EfG `M (NTH U �Ers� ONLY SHEET OR OVERLAND FLOWS ARE EXPECTED. �,••�� E11,' NOT TO SCALE PEKSPEU I IVE VIEW PVC VENT END VIEW FRONT VIEW SKIMMER NOT TO SCALE ENCLOSURE ENTRY UNIT 40 PIPE TB 36.0 IS WX M 36.0 Itl-10;11FLETARD 9Eif X000T 6QM '/7D MITI RIM 32.00 \�-- - - _ _ _ tOD-YEAR SipRM POOL ELEVAIXYN. ,3N.16' (STORM VOL: 69,589 CF; TOTAL T01: IC6,194 CF Tq; 20.52 9 6IANFACE AREA) INV 26.45 - - - - - - - - - - - - - - - - - - - -YEAR STORM POOL ELEVATI - - TO-rEra SmRu PaOL aEVAnoM: 3j.5S (STORM VOL: s6,si9 CF: TOTAL VOL: 93,124 CF VOL: 19.3n s SURFACE AREA) r - -- - - - - - 2-YEAR STORM POLL EIEVAIONN32.20_(STORM VOL_32,239 CF_TOTAL VOL: 6AeN CF VOL. 17,123 SF SURFACE AREA) r 10-YEAR STORM _ _ _ _ _ _ _ _ _ -WATEA auul Poo E E N 3D77 (S O M MO : 9,]66 U; O A VOL. N6361 T q ; 11,059 SF SURFACE taEA) - - - - J 17'_rDV®Ar PLBIAIEI POOL EL[VIIIOM: 30a ' K16PI ObC70 - - - - - - - - - - L15 90. DWI:FJ2-YEAR STORM POOL ELEVATI ourF°Ljsz - �1L ne xi3ABSFaWXEAEA �1O"" cmA o sn- - - -MAN Patio: PERUAM>rPowEEVAnoN: s - - _ Wwm _� a Zzo� - _ -' ) 3.+ iA¢rArED 30l fl➢a[ (24,&T2 OF VOL 1.615 SF YJFdACE AREA) I L-263 =15 RhALL) _ - WATER QUALITY POOL ELE- _ 1 LTL�' p0 17"- _ ' '- Hv zaoo �WDR arAxuoT DEVAIIDI: z2o' 2 I L- 27" FOREBAY: PERMANET POOL ELEVATION: 30.0' I .sn ° ° �o g N,N_Aa_ M6y I S971--Rf/--Uf-- 2----Wl_- 34-FAa__ JI INV 26U 3 (OUTFALL)' 15% \ (11,773 CF VOL: 3,835 SF SURFACE AREA) 0.1 INV 2F.0 3 BE VE( SECTION A -A (N.T.S.) BETWEE -rT1YV rvn�on, 1 ELEV 30.0 SEDI OUT ELEVATION: 27.0' J NV 28.00 _ 1 CF VOL2,507 SF SURFACE AREA) 2 1 SEDIMENT CLEANOUT ELEVATION: 25.0' (2,218 CF VOL 2,529 SF SURFACE AREA) 1 -- ------------- ----- 3 INV 26.0 3 INV 24.0 SECTION A -A (N.T.S.) CULVERT INLE T SEDIMENT TRAP y CLASS RA HEADWALL I ro YR,.r a WIeaRAAr MNNBIi mu, s1R a mac. aIa a.r./aac vn smAw a SVE) 0 G C.Y.Mtt aIRMZ 1eA55 Ci STpE 10 ttP Cf SIRE E1Y) PERSPECTIVE VIEW NCDOT #3, #357, OR #5COARSE AGGREGATE IIAMY A... ,EI➢RV. SOURCE: NORTH CAROLINA SEDIMENT CONTROL COMMISSION Plate 3.08-1 TB 33.0 TB 33.0 -� TEMPORACDOSAV 0 W/SO 840 033 1(�� W/ SKIMMER (INV 29.05) RIM 32.00 INV 26.45 77 _2�„RCP - _ 10-YEAR STORM SEDIMENT BASIN POOL ELEVATION: 31.43' (17,75' CF VOL: 9_499 SF SURFACE AREA _ (OUTF @ 015q'\, I _ -(� - - - _ - SEDIMENT BASIN TEMPORARY POOL ELEVATION: 29.0' (8,166 CF VOL: SF SURFACE AREA) L` 253 -1(OUTPALL) INV 26.5- INV 28.00 SECTION B-B (N.T.S.) - MAINTENANCE (CULVERT INLET PROTECTION) 1. THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED. 2. AGGREGATE SHALLBE REPLACED OR CLEANED WHEN INSPECTION REVEALS THAT CLOGGED VOIDS ARE CAUSING PONDING PROBLEMS WHICH INTERFERE WITH ON -SITE CONSTRUCTION. 3. SEDIMENT SHALL BE REMOVED AND THE IMPOUNDMENT RESTORED TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE AND CAUSE SEDIMENTATION PROBLEMS. 4. TEMPORARY STRUCTURES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. F F ti c w w 0 w a 0 Tn 0 0 h Z S S 0 _O F n Z Z Z LJJ Z � Z Z K � w x Q w x O m O IN L\I N I o+ LLJ N z W I r- N o z �D T 1 Q u) 't w Z Q m w Y LLJ � Q 0 5; O Wes, co L, Q Q LC) T 1 LLJ W w LLJ , IN m Ym z Q Q N 0 o _ oz` 0 O 0Z Of LLJ Z LLJ > O _ � W a J LLJ 6 � o cn rz 0 U U z W pE w Co co N Co C V 1 P. a0 FIQ C\2 poi tv U o Fy 6 VI w a Fry to Z Z a a a a c PQ a � rn E Ey SHEET 5 OF 6 I, T