Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW7091119_APPROVED PLANS_20191118
STORMWATER DIVISION CODING SHEET POST —CONSTRUCTION PERMITS PERMIT NO. SWU����°l DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ccc❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE�G YYYYMM DD Legend: EXISTING PROPOSED NO POINT SET Q^ GPS CONTROL EIS - EXISTING IRON STAKE ERWM - EXISTING R/W MARKER UTILITY POLE ® WATER METER H WATER VALVE N FIRE HYDRANT $ SEWER CLEANOUT CO* $$ SEWER VALVE CATCH BASIN CB■ DROP INLET ■ DI = OVERHEAD ELECTRIC OHE — - 5 - - —= SANITARY SEWER LINE S — -W- - UO TQWA%-k LINE w = SILT FENCE SF — -FO - - —= UNDERGROUND FIBER OPTIC - - UGT - - TELEPHONE T - -70- - CONTOUR 70 FIRE MAIN / SERVICE F GAS MAIN / SERVICE GAS ROOF DRAIN RD STORM DRAIN TEMPORARY DIVERSION DITCH Too CONDUIT CON COMMUNICATION / TELEPHONE coM LIMIT OF DISTURBANCE SOD DEMO / TO BE REMOVED 0149.94 GROUND ELEVATION X PG 22_00 TOP OF BACK OF CURB X BC 22_00 TOP OF CONCRETE x TC 22_00 TOP OF ASPHALT X TA 22_00 TOP OF SIDEWALK X TW 22_00 ROCK INLET SEDIMENT TRAP TRUNCATED DOMES to SPILL GUTTER CONCRETE WHEEL STOP ROCK CHECK DAM CD PAD led RIP RAP I` N/F \ FRIEDMAN/RAVENWOOD, LLC \ DB 1539, PG 001 N 1726'55" E TAX PIN 5664-75-7998 20.22' (ZONE B2) \ N 17'44'25" E 20.26' EIP EIP N 17'30'48" E 290.04' 1� N�1N EIP¢ 40' INGRESS, EGRESS & REGRESS EASEMENT (DB 1720, PG 632) (PLAT CABINET H, SLIDE 46-10) N/F FRIEDMAN/RAVENWOOD, LLC DB 1539, PG 001 TAX PIN 5664-75-7998 (ZONE B2) CONCRETE FLUME (REFER TO DETAIL) 24"CURB AND GUTTER ON SITE (TYPICAL) I I .-."-----._.._..-:L-..-..-•-----.._.._.._.._.._..-.._.._.._.._.._.._.._.._.._..-.._.._..-.._.. _.._.. _.._.._.._.. _.._.. I / CONCRETE DUMPSTER PAD 12' WIDE LANDSCAPE BUFFER -` I PROPOSED STORMWATER WETLAND WITH OPAQUE ENCLOSURE (REFER TO LANDSCAPE PLAN I (DESIGNED BY OTHERS) TO MATCH BUILDING. FOR PLANTING REQUIREMENTS % \ (REFER TO STORMWATER PERMIT NO SW7091119) (REFER TO ARCHITECTURAL PLANS) /' \ \ - SURVEY CO OL LIGHT DUTY ASPHALT NAIL CAP(BB 28 I do (TYP.) NC GRID I 3 - 2011) E=2568004.44 Z=31 3(NA - GEOIDI2B) CONCRETE \\ SIDEWALK L W I O 18 moo: WHITE PAI WHITE PAINTED 24" CURB AND GUTTER 4' SINGLE Q \\ Z w SOLID DIRECTIONAL ON SITE (TYPICAL) w I NTED ARROW (TYP) v i I STOP SIGN & LINE(S) [TYP) -' . _p + 00 i STOP BAR (TYP) DRIVE THRU LANE HEAW DUTY CONC. f HEAVY DUTY CONCRETE (115PACES) ' :p. " L ji' - D .- HEAW DUTY DUMPSTER PAD PRF1,000GALLONK\\ ANE AN 2 I 4" WIDE WHITE �/ - PAINT STRIPE) "� •:• 0a „ 4"WIDE WHITE PAVEMENT or I �" .D g'� f PAINT STRIPE � D s- rO 6' - PROPOSED MENU AND I _--- '_> '-- CONFIRMATION SIGN OD'.r \ gl8 .° 9d.ry. (FIELD LOCATE WITH 5 TRAILER PARKING CA920 "� PROPOSED `ti OWNER DURING SPACES (10'x50') N F MANGLES' ptih �y . CONSTRUCTION) 7qL \ 1 3,400±S.F. 2 1\ FIFE = 37.50 H/C RAMP (1:12 MAX SLOPE), \ TRANSITION FROM 30" TO 24" CONCRETE CURB AND GUTTER \ OVER 10' SPAN (TYPICAL) � `-SEW SURVEY CONTROL PVCS NAIL & CAP (BB1) ER FORCE MAIN 14' NC GRID (NAD83 - 2011) N=645680.2481 PROPOSED S 26'41'39" W EIP E=2568031.0349 STOP SIGN 20.08' Z=32.04(NAVD88 - GEOIDI2B) 6'X25' TAPER (TYP) Po CONNECT FLUSH TO CURBB &G30" & GUTTER ST R i EXISTING ASPHALT \ 4" WIDE DOUBLE YELLOW \, THERMOPLASTIC LINE A 1S' I 24" WIDE WHITE STOP BAR TRUNCATED DOMES (TYPICAL) 9� o CONCRETE WHEEL H/C SIGN (VAN ACCESSIBLE) 12' WIDE LANDSCAP PS (TYP) (REFER TE BUFFER m' °e - STOO w. - 5 - DETAIL FOR REQUIRED FLUSH CURB 10 (REFER LANDSCAPE PLAN PLACEMENT) 7' RAMP H/C SIGN ' 44 74FOR PLANTING REQUIREMENTS 14' 1 20' 10' 10' 10' 10' 10' o OR..o - °: - ° __ _ C- � ?'y 26' 20.5' CONCRETE -- - - \�O LIGHT ASPHALT �O. 2 HEAVY DUTY PAVEMENT I d� Ip. $(� Ip. � I----------1 I - ----- I• R3 - ,tD "%. - - ( 12'x4O' I WHITE PAINTED 1 S• 8• 8• 8• r , �® y.,D - I LOADING AREA �I DIRECTIONAL I �_ -.! �� ° 24" CURB AND GUTTER Lf _ _ - _ _ - - J ARROW (TYP) III_ ON SITE (TYPICAL) 4" WIDE WHITE BACK o o_ PAINTSTRIPE �, 40'FRONTYAR� 4' I �� S' �� HEAVY DUTY B' 24" CURB AND GUTTER PAVEMENT 4" DOUBLE YELLOW a� 4" SINGLE SOLID WHITE ON SITE (TYPICAL) q�,, H SOLID STRIPES - PAINTED UNE(S) (TYPICAL) I 1't Ot OS' FREESTANDING SIGN in in TRANSITION FROM 30" TO 24" CONCRETE CURB AND GUTTER OVER 10' SPAN (TYPICAL)- 30" CONCRETE CURB C1 AND GUTTER WITHIN w R/W (TYPICAL) LIGHT DUTY ASPHALT 24" CURB AND GUTTER "= PROPOSED � 30" NCDOT STD. (TYP.) ON SITE (TYPICAL) CURB &GUTTER STOP SIGN TURN DOWN CURB OVER 2' TURN DOWN CURB (TYP) OVER 2' (TYP) 6'X25'TAPER (TYP) 6'X25' TAPER P 29' N URB AND GUTTER ON SITE (TYPICAL) LIGHTDUTY TY ASPHALT (TYP) CONCRETE TRANSFORMER PAD (REFER TO ELECT. PLANS) aN SITION FROM 30" TO 24" CONCRETE CURB AND GUTTER OVER 10' SPAN (TYPICAL) 30" NCDOT STD. CURB & GUTTER TURN DOWN CURB OVER 2' /o `(TYP) WHITE PAINTED DIRECTIONAL ARROW (TYP) 4' D CONNECT FLUSH TO EXISTING ASPHALT - Vicinity Map •0 N W 9V m c�0 ��7_1: � CL Z rn PF c0 > •0 O N 11 �� -A * ar Z < to iflN��P * •.='C rn � Q TAPER (TYP) (TY) 2 WI E WHITE CONNECT FLUSH TO STOP BAR EXISTING ASPHALT 94'cam- - - --- -\ CONNECT FLUSH TO - 4"WIDE WHITE THERMOPLASTIC WHITE _ BRAGAW EXISTING ASPHALT MINI-SKIP THERMOPLASTIC - THERMOPLASTIC �- - -__ - __ LANE ��� LINES\,\ \ PAINT ARROW (D.B. 1570 PG, 617 \ \ \ \�,_ INSTALL NEW THERMOPLASTIC , 1`,.. 4" WIDE SOLID WHITES ) (120 r R/W) DOUBLE YELOW PAINT STRIPING ' _ THERMOPLASTIC TURN -LANE LINE r (COORDINAY: WITH NCD aT PRIOR Owner / Developer _ \�" (44'.5 EOP/Epp) TO PERFOIMING ANY WORK General Notes: INSTALL NEW THERMOPLASTIC STRIPING FOR -WITHIN THE RIGHT-OF-WAY) TURN LANE (COORDINATE WITH NCDOT PRIOR 1. NCDOT DRIVEWAY APPROVAL IS REQUIRED THROUGH THE NCDOT DISTRICT OFFICE. TO PERFORMING ANY WORK WITHIN THE 2. CONTACT NORTH CAROLINA ONE -CALL CENTER, INC. (NC ONE -CALL) AT 811 TO HAVE ALL UNDERGROUND RIGHT-OF-WAY) UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 3. ALL REQUIRED IMPROVEMENTS SHALL CONFORM TO THE LATEST EDITION OF THE TOWN OF CHOCOWINITY, - - - - - - - - - - - - -- LOCAL UTILITY COMPANY, AND NCDOT STANDARDS AND REGULATIONS. 4. CONTRACTOR SHALL CONTACT THE TOWN OF CHOCOWINITY PUBLIC WORKS DEPARTMENT PRIOR TO CONSTRUCTION TO SCHEDULE AN ON -SITE MEETING WITH A REPRESENTATIVE OF THE TOWN TO DISCUSS WATER AND SEWER SERVICE CONNECTIONS AND INSPECTION REQUIREMENTS FOR THE PROPOSED STEP TANK. 5. NO PORTIONS OF THIS PROPERTY ARE LOCATED IN A FLOOD ZONE (AREA DETERMINED TO BE OUTSIDE THE 0 2%ANNUAL CHANCE FLOOD PLAIN) AS SHOWN ON THE FEMA FLOOD INSURANCE RATE MAP NUMBER EIP WHITE PAINTED \ DIRECTIONAL ARROWS (TYP) t REDCO PROPERTIES, LLC - - 335 N. QUEEN STREET KINSTON, NC 28502 CONTACT: BRAD MERCER PHONE: (252) 522-0191 -------------- `' I ------------ Zoning Note:- Civil Engineer - - - VARIANCE REQUEST WAS APPROVED BY THE TOWN OF CHOCOWINITY BOARD OF 3720566400J, EFFECTIVE MAY 15, 2003. Parking Requirements: 6. ELECTRIC AND TELEPHONE UTILITIES SHALL BE INSTALLED UNDERGROUND. y�• PARKING REQUIRED: RESTAURANT- 7. PAVEMENT SECTIONS ARE AS INDICATED ON THE DETAIL SHEETS. �� 30 SPACES+ 8. PROVIDE ALL NECESSARY SIGNAGE FOR HANDICAP PARKING. W 1 SPACE PER 3 SEATS+ 1 SPACE PER 3 EMPLOYEES 9. PARKING LOT SHALL BE STRIPED IN ACCORDANCE WITH PLAN. Q 1 SPACES x 77 SEATS/3 + 1 SPACE x 12 EMPLOYEES/3 60 SPACES 10 REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS. v A, TOTAL RE UIRED PARKING 60 SPACES Q 11. REFER TO M.E.P. PLANS FOR COORDINATION OF BUILDING UTILITY SERVICES. �Q REQUIRED HANDICAP PARKING: 3 SPACES 12. CONTRACTOR SHALL STOCKPILE TOPSOIL FOR USE IN LANDSCAPE AREAS. N i 13. STORMWATER MANAGEMENT FOR THIS SITE IS REQUIRED. Regulatory Agencies: 14. THIS PROJECT DISTURBS MORE THAN 1 ACRE. EROSION CONTROL PLAN APPROVAL IS REQUIRED. Planning & Zoning NCDOT 15. REFUSE COLLECTION SHALL BE PROVIDED BY PRIVATE SERVICE. 16. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. THE MID -EAST COMMISSION NCDOT HIGHWAY DIV. 2, DISTRICT 1 1502 N. MARKET STREET 1701 WEST. 5TH STREET 17. A REDUCED PRESSURE PRINCIPAL BACKFLOW DEVICE IS REQUIRED ON THE DOMESTIC WATER SERVICE. WASHINGTON, NC 27889 WASHINGTON, NC 27889 CONTACT NOLA ROBERTS CONTACT GENE PITTMAN 18. SITE SHALL MEET ALL RELATED ACCESSIBILITY CODE REQUIREMENTS. 19. CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH THE NCDOT STANDARDS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, ROADS, HIGHWAYS, ETC. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND COORDINATE WITH THE LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT, AND LIMITATIONS ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. 20. LIGHTPOLES ARE SHOWN FOR REFERENCE AND COORDINATION WITH UTILITIES AND LANDSCAPING. LOCATIONS SHOWN ARE APPROXIMATE. REFER TO ARCHITECTURAL DRAWINGS FOR SITE LIGHTING AND ELECTRICAL PLANS FOR DESIGN AND EXACT LOCATIONS. PHONE: (252) 974-1829 PHONE: (252) 623-5300 Erosion Control Stormwater NCDEQ WASHINGTON REGIONAL OFFICE NCDEQ WASHINGTON REGIONAL OFFICE 943 WASHINGTON SQUARE MALL 943 WASHINGTON SQUARE MALL WASHINGTON, NC 27889 WASHINGTON, NC 27889 CONTACT: J. RANDALL JONES CONTACT: CARL DUNN PHONE: (252) 948-3857 PHONE: (252) 948-3959 Pavement Legend: HEAVY DUTY CONCRETE CONCRETE SIDEWALK "D 6- HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT ADJUSTMENTS ON OCTOBER 29TH TO ALLOW PARKING TO BE INSTALLED IN THE ARK CONSULTING GROUP, PLLC. FIRST 15 FEET OF THE FRONT PROPERTY LINE SETBACK. 2755-B CHARLES BLVD. GREENVILLE, NC 27858 Survey Note: CONTACT: BRIAN O'KANE, PE PHONE: (252) 565-1026 BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED Surveyor BY BARROW AND BARROW, P.A., AS SHOWN CN DRAWING ENTITLED EXISTING CONDITIONS AND TOPOGRAPHIC SURVEY, PROPOSED BOJANGLES' RESTAURANT, BARROW & BARROW, P.A. CHOCOWINITY, DATED OCTOBER 15, 2019, AT -ACHED TO THIS DRAWING SET FOR 115 HERITAGE CROSSING SNOW HILL, NC 28580 REFERENCE. CONTACT: DARRYL BARROW, PLS SHEET INDEX PHONE: (252) 747-5790 Site Data: TOTAL ACREAGE IN SITE: 1.86± AC. GPIN: 5664-85-0949 CURRENT ZONING: B-2 GROSS FLOOR AREA: 3,400 S.F BUILDING LOT COVERAGE: 0% EXIST., 4.2% PROPOSED BUILDING HEIGHT IN FT. & STORIES: 22'-5 Z' (1 STORY) TOTAL NO. OF PARKING SPACES REQUIRED: 60 SPACES (INCL 3 HC) TOTAL NO. OF PROPOSED PARKING SPACES: 67 SPACES (INCL. 3 HC) TOTAL SQ. FEET OF EXIST. IMPERVIOUS AREA: 0 SF PROPOSED IMPERVIOUS (TRANSPORTATION): 44,610 SF PROPOSED IMPERVIOUS (BUILDING): 3,416 SF TOTAL PROPOSED IMPERVIOUS: 48,026 SF DISTURBED ACREAGE: 2.50 AC. REFERENCES: DEED BOOK 1270, PAGE 434 ADDRESS: BRAGAW LANE Architect Sheet No. C-1 Site Plar DUNN & DALTON ARCHITECTS Sheet No. C-2 Demolition and Erosion Control Plan 401 NORTH HERRITAGE STREET Sheet No. C-3 Utility Pion 1 KINSTON, NC 28501 Sheet No. C-4 Gradin and Drainage Pla CONTACT:AMYPERRY g g ;tECEI VEt� kid 1 2 19 PHONE: (252) 527-1523 Sheet No. C-5 Landscaping Plan Contractor Sheet No. C-6 Erosion Control Details Sheet No. C-7 Erosion Control Details Sheet No. C-8 Details Sheet No. C-9 Details Survey 1 Sheet (BARROW AND BARROW, P.A. - Surveyor) BoBUILDERS, LLC 335 N. QUEEN STREET KINSTON, NC 28502 CONTACT: TILLMAN CARTER PHONE: (252) 208-2223 20' 0 10, 20' SCALE 1 inch = 20 ft v (� Z � 0 cc V ■ Z Z O W Z 7 V J 0 IL = O S '�^w Co W � J 0 O Z Q �1••• O O r. im F SEAL 2 037468 ��r�nnnrnl"� o IIIIJ12019 m D d Z UD Z = Jag tea; Z ZOw u 0 z u�W DO .600 Ln >C c r, a+ V H Z Do c M 0 D 9 O U v Y m>U) 1na�i�,3 '^ w in 3 NL7�3 Project Manager. BTO Drawn By: EW Checked By: STA Project Number: 19041 Drawing Number. D-1183 C-1 Date: 11-01-2019 c a 2' (-------- -I 12'x4O' ' LOADING AREA a_ 24" CURB AND GUTTER L�- - - - - - - J ON SITE (TYPICAL) BACK - =FRONT YARD �� HEAVY DUTY 24" CURB AND GUTTER PAVEMENT ON SITE (TYPICAL) q3, y Oti Vicinity Map -0 a W rA ��Q� 0 s� $i2'6 t�-0 LT X,if OZ -c. P_ 1, rn" �1T c^ A s 1� 0 NN N I � O 12' WIDE LANDSCAPE BUFFER \ 10 (REFER TO LANDSCAPE PLAN FOR PLANTING REQUIREMENTS 0 26' 20.5' 10' 10' O 10, 10' 10' 1s N � ;cti TRANSITION FROM 30" TO 24" CONCRETE CURB AND GUTTER OVER 10' SPAN (TYPICAL) 30" CONCRETE CURB C1 AND GUTTER WITHIN w R/W (TYPICAL)-� LIGHT DUY ASPHALT 24" CURB AND GUTTER - 'N"- IPA (TYP.) ON SITE (TYPICAL) PROPOSED STOP SIGN TURN DOWN CURB OVER 2' (TYP) 6'X25' TAPER (TYP) 2W 17. A REDUCED PRESSURE PRINCIPAL BACKFLOW DEVICE IS REQUIRED ON THE DOMESTIC WATER SERVICE. WASHINGTON, NC 27889 WASHINGTON, INC 27889 BUILDING HEIGHT IN FT. &STORIES: 22'-51" (15TORY) 1 Sheet No. C-7 Erosion Details 18. SITE SHALL MEET ALL RELATED ACCESSIBILITY CODE REQUIREMENTS. CONTACT: NOLA ROBERTS PHONE: (252) 974-1829 CONTACT: GENE PITTMAN PHONE: (252) 623-5300 TOTAL NO. OF PARKING SPACES REQUIRED: 60 SPACES (INCL 3 HC) Sheet No. C-8 ..ontrol Details TOTAL NO. OF PROPOSED PARKING SPACES: 67 SPACES (INCL 3 HC) 19. CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH THE Erosion Control Stormwater TOTALSE FEET OF EXIST. : Sheet No. C-9 Details NCDOT STANDARDS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, RANSP RTATION)OUS PROPOSED IMPERVIOUS (TRANSPORTATION): 44,610 SF 44, ROADS, HIGHWAYS, ETC. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND NCDEQ WASHINGTON REGIONAL OFFICE NCDEQ WASHINGTON REGIONAL OFFICE PROPOSED IMPERVIOUS (BUILDING): 3,416 SF COORDINATE WITH THE LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT, AND LIMITATIONS 943 WASHINGTON SQUARE MALL 943 WASHINGTON SQUARE MALL TOTAL PROPOSED IMPERVIOUS: 48,026 SF Survey 1 Sheet ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. WASHINGTON, NC 27889 WASHINGTON, NC 27889 DISTURBED ACREAGE: 2.50 AC. 20. LIGHTPOLES ARE SHOWN FOR REFERENCE AND COORDINATION WITH UTILITIES AND LANDSCAPING. CONTACT: J. RANDALLJONES CONTACT: CARL DUNN REFERENCES: DEED BOOK 1270, PAGE 434 (BARROW AND BARROW, P.A. - Sirveyor) LOCATIONS SHOWN ARE APPROXIMATE. REFER TO ARCHITECTURAL DRAWINGS FOR SITE LIGHTING AND PHONE: (252) 948-3857 PHONE: (252) 948-3959 ADDRESS: BRAGAW LANE ELECTRICAL PLANS FOR DESIGN AND EXACT LOCATIONS. Legend: EXISTING PROPOSED NO POINT SET QGPS CONTROL EIS - EXISTING IRON STAKE ERWM - EXISTING R/W MARKER UTILITY POLE ® WATER METER H WATER VALVE N FIRE HYDRANT ♦' $ SEWER CLEANOUT COS $$ SEWER VALVE CATCH BASIN CBS DROP INLET ■ DI = OVERHEAD ELECTRIC axe - - S - - -= SANITARY SEWER LINE 5 - - W - - NOT Q LINE W = SILT FENCE 5F - -FO - - -= UNDERGROUND FIBER OPTIC - - UCT - - TELEPHONE T - -70- - CONTOUR 70 FIRE MAIN / SERVICE F GAS MAIN / SERVICE GAS ROOF DRAIN RD = STORM DRAIN TEMPORARY DIVERSION DITCH TOD CONDUIT CON COMMUNICATION / TELEPHONE cam LIMIT OF DISTURBANCE LOD DEMO / TO BE REMOVED 0149.es GROUND ELEVATION X PG 22_00 TOP OF BACK OF CURB X BC 22_00 TOP OF CONCRETE X TC 22_00 TOP OF ASPHALT X TA 22_DO TOP OF SIDEWALK X TW 22_00 ROCK INLET SEDIMENT TRAP TRUNCATED DOMES I SPILL GUTTER CONCRETE WHEEL STOP ROCK CHECK DAM CD RIP RAP PAD N 17'26'55" E 20.22' N 1744'25' E N/F FRIEDMAN/RAVENWOOD, LLC DB 1539, PG 001 TAX PIN 5664-75-7998 (ZONE B2) 20.26 EIP EIP N 17'30'48" E 290.04' m NTH EIP---- 40' INGRESS, EGRESS & REGRESS EASEMENT (DB 1720, PG 632) (PLAT CABINET H, SLIDE 46-10) N/F FRIEDMAN/RAVENWOOD, LLC DB 1539, PG 001 TAX PIN 5664-75-7998 (ZONE 62) CONCRETE FLUME (REFER TO DETAIL) 24" CURB AND GUTTER ON SITE (TYPICAL) \ TRANSITION FROM 30" TO 24" CONCRETE CURB AND GUTTER O OVER 10' SPAN (TYPICAL) 3" _ R f MA1 NAIL SURVEY CONTROL FV AP ( BI) CSAN•SEWERFO NC GRID (NAD83 - 2011) N� N=645680.2481 PROPOSED S 26'41'39" W E=2568031.0349 STOP SIGN 20.08' Z=32.04(NAVD88 - GEOIDI2B) 6'X25'TAPER (TYP) 'Pao, CONNECT FLUSH TO 30" NCDOT STD. EXISTING ASPHALT CURB&GUTTER \ 4" WIDE DOUBLE YELLOW THERMOPLASTIC LINE T 25' I 14' "/ 4 \l 973 � I I / CONCRETE DUMPSTER PAD 12' WIDE LANDSCAPE BUFFER 1 PROPOSED STORMWATER WETLAND WITH OPAQUE ENCLOSURE (REFER TO LANDSCAPE PLAN7 (DESIGNED BY OTHERS) TO MATCH BUILDING. FOR PLANTING REQUIREMENTS ; \ \ (REFER TO STORMWATER PERMIT NO SW7091119) (REFER TO ARCHITECTURAL l� I PLANS) I �' �..-..-..-..-..-.L----. ..-..-..-..-.._.. / SURVEY L I j CO LIGHT DUTY ASPHALT NAIL do CAP(BB 14C GRID (N q I 28 I (TYP.) AD N=646140.1 2011) E=2566004.44 GEOID728) Q CONCRETE SIDEWALK \ z I N \ Q N w 2 � ITT' 18 'P3, se W IVI N N cc i q , WHITE PAINTED 24" CURB AND GUTTER - m ° 4' SINGLE SOLID - DIRECTIONAL ON SITE (TYPICAL) WHITE PAINTED 2 ARROW (TYP)------ _ - a I STOP SIGN & LINE(S) (tYP) N ♦� ° .' ._ o ' ff STOP BAR (TYP) \ R (11 SPACES) LANE HEAVY DUTY CONCRETE HEAVY DUTY CONC. DRIVE Z 4" WIDE WHITE f�. --�"- T-e�.e o HEAVY DUTY DUMPSTER PAD •a �' F1,000GALLON J d PROPANE TANK I I PAINT STRIPE rQ Z ' oy j -p t'i „ ! �' > _\ . 4" WIDE WHITE PAVEMENT 12' ! r o' PAINTSTRIPE 1 PROPOSED MENU AND - 6 �•z �. -� CONFIRMATION SIGNS •'.r (FIELD LOCATE WITH 5 TRAILER PARKING .r o •. > OWNER DURING SPACES (10'x5O') q20 PROPOSED, _ , h CONSTRUCTION) F Own) MANGLES ro w o. . 3,400±S.F. 2 ' FFE = 37.50 H/C RAMP (1:12 MAX SLOPE) TRUNCATED DOMES (TYPICAL) o CONCRETE WHEEL H/C SIGN (VAN ACCESSIBLE) m ° STOPS (TYP) (REFER TO a ,N • -- DETAIL FOR REQUIRED FLUSH CURB v - - T RAMP !!! -� _42' ~ PLACEMENT) H/C SIGN ' - 44.74' o _ - _ - �. CONCRETE SIDEWALK - O O O O LIGHT DUTY ASPHALT° (TYP.) 92 £- ..,. tia ( ti HEAVY DUTY I � 9s �•rL � �7 PAVEMENT -- --- I?• Ip, $O Ip, a -- I WHITE PAINTED I S' 8• 8• 8' ® 'w.: DIRECTIONAL ARROW (TYP) I I 4" WIDE WHITE PAINT STRIPE Sa 4" DOUBLE YELLOW A -a 4" SINGLE SOLID WHITE SOLID STRIPES PAINTED UNE(S) (TYPICAL) I $t QS FREESTANDING SIGN 30" NCDOT STD. CURB & GUTTER TURN DOWN CURB OVER 2' (TYP) 'L WHITE PAINTED'--_, 6'X25' TAPER (TYP) DIRECTIONAL '------ 24" WIDE WHITE ARROWS (TYP) CONNECT FLUSH TO 31STOP BAR EXISTING ASPHALT 25' --__- 94, i MA ---"WHITE 4" WIDE WHITE THERMOPLASTIC THERMOPLASTIC -___ BRAGA W LANE MINI -SKIP LINES PAINT ARROW �_-- T� pp C_- _ (JJ.JJ. 1570, PG. 617) (120' R/ 4" WIDE SOLID WHITE �b THERMOPLASTIC TURN -LANE LINE ' (44.5' EOP/EOP) General Notes: - INSTALL NEW THERMOPLASTIC STRIPING FOR TURN LANE (COORDINATE WITH PRIOR 1. NCDOT DRIVEWAY APPROVAL IS REQUIRED THROUGH THE NCDOT DISTRICT OFFICE. �. THE TO PERFORMING ANY WORK WITHINHIN THE RIGHT-OF-WAY) f 2. CONTACT NORTH CAROLINA ONE -CALL CENTER, INC. (NC ONE -CALL) AT 811 TO HAVE ALL UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 3. ALL REQUIRED IMPROVEMENTS SHALL CONFORM TO THE LATEST EDITION OF THE TOWN OF CHOCOWINITY, - - - - - - - - - _ _ - LOCAL UTILITY COMPANY, AND NCDOT STANDARDS AND REGULATIONS. 4. CONTRACTOR SHALL CONTACT THE TOWN OF CHOCOWINITY PUBLIC WORKS DEPARTMENT PRIOR TO CONSTRUCTION TO SCHEDULE AN ON -SITE MEETING WITH A REPRESENTATIVE OF THE TOWN TO DISCUSS WATER AND SEWER SERVICE CONNECTIONS AND INSPECTION REQUIREMENTS FOR THE PROPOSED STEP TANK. S. NO PORTIONS OF THIS PROPERTY ARE LOCATED IN A FLOOD ZONE (AREA DETERMINED TO BE OUTSIDE THE AS SHOWN ON THE FEMA FLOOD INSURANCE RATE MAP NUMBER 24 CURBANDGUTIER ON SITE (TYPICAL) LIGHT DUTY ASPHALT [TYP-) \ CONCRETE TRANSFORMER PAD (REFER TO ELECT. PLANS) TRANSITION FROM 30" TO 24" CONCRETE CURB AND GUTTER OVER 10' SPAN (TYPICAL) 30" NCDOT STD. CURB & GUTTER TURN DOWN CURB OVER 2' (TYP) 6'X25' TAPER (TYP) WHITE ----- - E PAINTED DIRECTIONAL ARROW (TYP) CONNECT FLUSH TO EXISTING ASPHALT 24' WIDE WHITE STOP BAR - CONNECTFLUSHTO EXISTING ASPHALT INSTALL NW THERMOPLASTIC � / DOUBLEYEL.OW PAINT NCDSTRIPINGPRIOR Owner / Developer \ \ (COORDINATE WITH NCDOT PRIOR � TO PERFCIMING ANY WORK -WITHIN TIE RIGHT-OF-WAY) REDCO PROPERTIES, LLC - 335 N. QUEEN STREET - - - - - KINSTON, NC 28502 CONTACT: BRAD MERCER - - - - - - PHONE: (252) 522-0191 Zoning Note: - - - - - - - Civil Engineer - - - VARIANCE REQUEST WAS APPROVED BY THE TOWN OF CHOCOWINITY BOARD OF EIP 0.2%ANNUAL CHANCE FLOOD PLAIN), 3720566400J, EFFECTIVE MAY 15, 2003. Parking Requirements: 6. ELECTRIC AND TELEPHONE UTILITIES SHALL BE INSTALLED UNDERGROUND. L PARKING REQUIRED: RESTAURANT- 7. PAVEMENT SECTIONS ARE AS INDICATED ON THE DETAIL SHEETS. w 30 SPACES+ 8. PROVIDE ALL NECESSARY SIGNAGE FOR HANDICAP PARKING. Gi J ti , 1 SPACE PER 3 SEATS + 1 SPACE PER 3 EMPLOYEES 9. PARKING LOT SHALL BE STRIPED IN ACCORDANCE WITH PLAN. � 1 SPACES x 77 SEATS / 3 + 1 SPACE x 12 EMPLOYEES / 3 60 SPACES 10. REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS. 1 ,Q TOTAL REQUIRED PARKING: 60 SPACES 11 REFER TO M E P PLANS FOR COORDINATION OF BUILDING UTILITY SERVICES S ADJUSTMENTS ON OCTOBER 29TH TO ALLOW PARKING TO BE INSTALLED IN THE ARK CONSULTING GROUP, PLLC. FIRST 15 FEET OF THE FRONT PROPERTY LINE SETBACK. 2755-B CHARLES BLVD. GREENVILLE, NC 27858 Survey Note: CONTACT: BRIAN O'KANE, PE PHONE: (252) 565-1026 BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED Surveyor BY BARROW AND BARROW, P.A., AS SHOWN ON DRAWING ENTITLED EXISTING CONDITIONS AND TOPOGRAPHIC SURVEY, PROPOSED BOJANGLES' RESTAURANT, BARROW & BARROW, P.A. CHOCOWINITY, DATED OCTOBER 15, 2019, ATTACHED TO THIS DRAWING SET FOR 115 HERITAGE CROSSING SNOW HILL, NC 28580 REFERENCE. CONTACT: DARRYL BARROW, PLS SHEET INDEX PHONE: (252) 747-5790 Architect & REQUIRED HANDICAP PARKING: 3 SPACES Sheet No. C-J. Site Plan 12. CONTRACTOR SHALL STOCKPILE TOPSOIL FOR USE IN LANDSCAPE AREAS. 401 N &DAL ER ARCHITECTS '� � Sheet No. C-2 Demoliton and Erosion Control Plan 401 NORTH HERRITAGE STREET 13. STORMWATER MANAGEMENT FOR THIS SITE IS REQUIRED. Regulatory Agencies: Site Data: KINSTON, NC 28501 14. THIS PROJECT DISTURBS MORE THAN 1ACRE. EROSION CONTROL PLAN APPROVAL IS REQUIRED. Sheet No. C-3 Utility Plan TOTAL ACREAGE IN SITE: 1.86± AC. CONTACT: AMY PERRY Planning & Zoning NCDOT GPIN: 5664-85-0949 Sheet No. C-4 Gradingand Drainage Plan PHONE: (252) 527-1523 15. REFUSE COLLECTION SHALL BE PROVIDED BY PRIVATE SERVICE. THE MID -EAST COMMISSION NCDOT HIGHWAY DIV.2,DISTRICT I CURRENT ZONING: B-2 Sheet No. C-5 Landsca3ing Plan Contractor 16. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 1502 N. MARKET STREET 1701 WEST. STH STREET GROSS FLOOR AREA: 3,400 S.F BUI LDINGLOTCOVERAGE 0%EXIST 42%PROPOSED an No C-6 Erosion Control Details BOBUILDERS,LLC 33S N. QUEEN STREET KINSTON, NC 28502 CONTACT: TILLMAN CARTER PHONE: (252) 208-2223 20' 0 10' 20 SCALE 1 inch = 20 ft ■ � C • q d * n� •u � X � c.1 e � v p w 0 M Z w `} 0 cc Z 0 C O U W Z O V J O � W = Q O a V/ m � W "0 J'w V 0 Z Q 0 n 3 W SEAL = OJ7468 IN m 1111312019 m d Z uw y J L z s tea; �Dcc z ZOw 0 U OWE = VWzW 00 ° .6 Ln m 00 C m N Y n OD U W BD n N O O DO y U- Ln i m C 10 v1wN3 'n d u1 3 N lD N 3 Project Manager. BTO Drawn By: EW Checked By: STA Project Number. 19041 Drawing Number: D-1183 C-1 Date: 11-01-2019 "SITE WASHINGTON N \ Ri�FR \ _J CHOCOWINITY BAY W 33 \ \ NOT TO SCALE INDEX CV-01 COVER SHEET C-01 EXISTING CONDITIONS C-02 OVERALL SITE PLAN C-03 SITE/UTILITY PLAN C-04 GRADING/DRAINAGE PLAN C 05 EROS/ON &SED/MENTAT/ON CONTROL PLAN D-01 UTILITY DETAILS D-02 MISCELLANEOUS DETAILS 1 D-03 MISCELLANEOUS DETAILS 2 D-04 EROSION & SEDIMENTATION CONTROL DETAILS SITE INFORMATION LOCATION: .. . . . . . . . . . . . . . . NW QUADRANT NC 33 & SR 1142 BRAGAW LANE CHOCOWINITY, NC 27817 COUNTY:. . . . . . . . . . . . . . BEAUFORT COUNTY PIN: . . . . . . . . . . . . . . . . . 11015049 GPI N: . . . . . . . . . . . . . . 5664-85-0844 ACCT_N BR : . . . . . . . . . . . . . . . 880777 MAP SHEET . . . . . . . . . . . . . . .566412 DB/PG . . . . . . . . . . . . . . . . .1539/0001 ZONING: . . . . . . . . . . . . . . . . . B-2 ACREAGE . . . . . . . . . . . . . . . .1.86 AC SETBACKS: FRONT YARD . . . . . . . . . . . . . . .40' SIDE YARD . . . . . . . . . . . . . . .15' BUILDING DATA: PROPOSED USE: . . . . . . . . . . . .RESTAURANT TOTAL BUILDING SIZE:. . . . . . . . . .3,847 SQ. FT. BUILDING HEIGHT: . . . . . . . . . . . .20' PARKING PROVI REGULAR 9x19. . . . . . . . . . .63 TRUCK . . . . . . . . . . . . . . . . . 15 H.C. (REGULAR) . . . . . . . . . . . . .2 H.C. (VAN ACCESSIBLE). . . . . . . .1 DRIVE THRU STACKING . . . . . . . .6 LOADING AREA . . . . . . . . . . . . .1 TOTAL: . . . . . . . . . . . . . . . . .71 FLOOD PANEL MAP #. . . . . . . . .3720566400J IMPERVIOUS AREA:. . . . . . . . . . .51,385 S.F./1.18 Ac. (63%) LANDSCAPE / GRASS AREA:. . . . . .29,621 S.F./O.68 Ac. (37%) TOTAL AREA DISTURBED: . . . . . . . .2.15 Ac. Architect: Dunn & Dalton Architects 401 W. Heritage Street Kinston, NC 28501 252.527.1523 (v) 252.527.0049 (f) Contact: Drew Dalton Contractor: BoBUILDERS, LLC 335 N. Queen Street Kinston, INC 28502 252.208.2223 (v) 252.527.9445 (f) Contact: Tillman Carter GOVERNING AGENCIES: NCDOT NCDOT DIV 2, DIST 1 1701 W 5TH STREET WASHINGTON, NC 27889 (252) 946-3689 CONTACT: WOODY JARVIS, PE PI ANNINr/70NINr MID -EAST COMMISSION 1385 JOHN SMALL AVENUE WASHINGTON, NC 27889 (252) 946-8043 (P) (252) 946-5489 (F) CONTACT: BRYANT BUCK EROSION CONTROL: NCDENR REGIONAL OFFICE 943 WASHINGTON SQUARE MALL WASHINGTON, NC 27889 (252) 946-6481 CONTACT: PAT McCLAIN, PE STORMWATER NCDENR REGIONAL OFFICE 943 WASHINGTON SQUARE MALL WASHINGTON, NC 27889 (252) 946-6481 CONTACT: AL HODGE UTILITY AGENCIES: WATER CHOCOWINITY PUBLIC WORKS 3391 HWY 17 SOUTH CHOCOWINITY, NC 27817 (252) 946-6568 CONTACT: JEFF HADDOCK SEWER CHOCOWINITY PUBLIC WORKS 3391 HWY 17 SOUTH CHOCOWINITY, NC 27817 (252) 946-6568 CONTACT: JEFF HADDOCK ELECTRIC PROGRESS ENERGY 103 EXECUTIVE PARKWAY NEW BERN, NC 28562 800 452-2777 0 CONTACT: BRUCE NOBLES kenneth.nobles@pgnmail.com TELEPHONE EMBARQ 3718 HWY 264 EAST WASHINGTON, NC 27889-7234 (252) 946-7131 CONTACT: STEPHEN WOOLARD BOJANGLES' PAVEMENT SECTIONS I HEAVY FLEXIBLE PAVEMENT FLEXIBLE PAVEMENT ,UTY LIGHT •• , UTY NOT TO ALE ASPHALT - ASPHALT : 8" CABC 6" CABC it M--O COMPACTED- COMPACTED- 1 IIF i D (DUMPSTER PAD (SIDEWALKS & H.C. RAMPS) & LOADING AREA) LIGHT DUTY HEAVY DUTY RIGID PAVEMENT RIGID PAVEMENT NOT TO SCALE NOT TO SCALE 4,000 PSI CONC. 3,000 PSI CONC. 0 28 DAYS • • ; ' '::. 0 28 DAYS 6" THICK ^ ..a..,.. . .: , 4° THICK 6" CABC COMPACTSUBGRADED �I COMPACTED -, II� SUBGRADE NOTES: 1. ON HEAVY DUTY RIGID PAVEMENT, STONE MAY BE OMITTED ® THE OWNER'S DISCRETION, PENDING SATISFACTORY SOIL TESTING RESULTS. Owner: REDCO Properties, LLC 335 N. Queen Street Kinston, NC 28502 252.522.0191 (v) Contact: Brad Mercer General Notes: 1. Topographical data performed by Barrow & Barrow. Site Benchmark is a new iron pipe located at (N) 513,090,.2452, (E) 2,644,760.3554, At the (SE) corner of property 654,143,411,200. Reference horizontal datum is NAD 83. Contours shown hereon are from an actual field survey. Boundary information supplied by owner and shown for reference only. Consult PLS for actual boundary data. 2. The contractor shall notify and cooperate with all utility companies or firms having facilities on or adjacent to the site before disturbing, altering, removing, relocating, adjusting or connecting to said facilities. The Owner shall pay all costs in connection with alteration of or relocation of any existing facilities. 3. All excavation is unclassified and shall include all materials encountered. 4. All structural fill material shall be free of all sticks, rocks, and clumps of mud. 5. Unusable excavated materials and all waste resulting from clearing and grubbing shall be disposed of off -site by the contractor in an approved solid waste landfill. 6. The proposed buildings will NOT be sprinkled. 7. There are existing underground gas, water, sewer, electrical, and FIBER OPTIC on -site or within close proximity. CONTRACTORS shall dig with extreme caution. 8. Concrete Sub shall be responsible for all score joints and expansion joints. Should a question arise about the proposed pattern consult with the engineer prior to pouring. 9. Contractor to furnish all pavement markings as shown. 10. Location of underground utilities are approximate and must be field verified. Contact the NC One Call Center at least 48 hours prior to digging ® 1.800.632.4949. Steve Barrow, PLS has only located the utilities that are above ground at the time of field survey. Underground lines shown hereon are approximate or as reported by various responsible parties. The surveyor does not guarantee that any underground structures such as utilities, tanks and pipes are located hereon. 11. All pipe lengths are horizontal distances and are approximate. 12. All work shall comply with all applicable codes, regulations, and/or local standards imposed by local utility and The Town of Chocowinity, and NCDOT. 13. All construction and materials shall meet The Town of Chocowinity Specifications and Standards, latest edition. All work within NCDOT right-of-way shall meet the specifications and standards of NCDOT. 14. All concrete pipe is to be ASTM C-76, Class III with ram-nek. 15. This property is not located in a Flood Hazard Zone per FEMA Map. FEMA Community Map #: 3720566400J , dated May 15, 2003. 16. All lot dimer.s?ons shown are approximate. Consult the boundary survey of actual site -ry it r� ion. 17. Wetlands are esent on site. See C-01 for survey existing wetlands. 18. the Co si e for all work zone tra is co ro in or adjacent to NCDOT right-of-way. All signs, pavement markings and other traffic control devices shall conform to the Manuil on Uniform Traffic Control Devices (MUTCD), latest edition. 19. Prior to placing CABC stone base, the Contractor should notify the Project Engineer to inspect and proof roll the subgrade. Any stone place without prior approval will be the sole responsibility of the Contractor. 20. DESIGN/FIELD CONDITIONS quite easily may vary from that represented in the initial soils report and/or topographical report. Isolated areas may show up weak and adverse soils or groundwater conditions may be discovered that were not revealed during the initial soils investigation. Therefore, the Owner/Client is to be aware that Stocks Engineering, P.A. will not and cannot be held responsible for any failures to either a street or parking lot pavement design unless we can be fully and totally involved in the construction process which may include, but may not necessarily be limited to, testing subgrade and base density, engaging the Design Engineer for the evaluation of the subgrade and for the observation of proof rolling subgrade and base at various steps of construction, opportunity for the Design Engineer to call in a soils engineer for consultation and advice, etc. - steps which taken altogether with the initial design shown on the plans, constitute the complete design of the road, street of parking area (private or public). The Design Engineer must be given the full latitude and opportunity to complete the design by fully participating in the constriction process. Plan design is a small portion of the Design and cannot be separated from the construction process if the Owner's/Client's desire is to have the Design Engineer stond behind the completed designed project. 21. All utility services, (power, telephone, cable, etc.) are proposed to be underground. Do not seed or n : !.:h disturbed areas until all underground utilities have been installed. 22. Site light po,:s are shown for general location only. Actual location, height, and specs to be verified with Ar.:hitectural plans or Lighting consultant. 23. Property is to br, served by the Town of Chocowinity (water & sewer). 24. The building ettack lines shown on this plat are for the Engineer's use in establishing minimum lot :rontages at the setback line and for reserving sufficient building area. Building Contr::: tors are to verify lot line setbacks before setting forms or digging footings. 25. Regulatory signs, :tops signs and street name signs shall be manufactured from high intensity renect:ve. .materials. 26. All excess ;, nFoi' and unclassified excavation is to be hauled off -site, unless otherwise directed b,, ",;. owner. 27. All site cnstruction must be inspected by The Project Engineer at the following stages: A. Completion of grading subgrade prior to placing Stone Base. B. Completion of Stone placement prior to paving. C. Final inspection when all work is complete. 28. The surveyor did not visibly see any cemeteries in any open areas unless otherwise noted. 29. This property does not depict encumbrances that are found during a thorough title search. 30. Concrete Sub shall be responsible for all score joints and expansion joints. 31. All HVAC units for the proposed building will be located on the roof. 32. All curb and titter to be 24" standard curb and gutter. All curb and Gutter within NCDOT or Town of C6ocowinty R/W shall be 30" standard. 33. All curb and gutter and sidewalk concrete is to be minimum 3,000 psi at 28 days, air entrained. 34. All dimensio- are to face of curb unless indicated otherwise. 35. Provide handicap signs, marking and ramps as shown. 36. Handicap ramps are to meet "ADA Accessibility Guidelines for Buildings and Facilities" as detailed in the Federal Register, Volume 56, Number 144 dated July 26, 1991, rules and regulations activated January 26, 1992. For additional information, refer to the NC State Building Code Volume 1-C, "Making Buildings and Facilities Accessible to the Useable by the Physically Handicapped", 1991 edition. All street returns to have H.C. Ramps. 37. Contractor SHALL NOT POUR any concrete before forms are inspected by the Project Engineer and/or Owner. Any concrete that has not been approved by the Engineer and/or Owner will be the responsibility of the contractor. 38. All areas not covered by building or parking shall be covered with 4" minimum of topsoil, free of root matter and rocks and grassed. 39. Contractor sholl sow -cut to provide smooth transitions where existing asphalt and/or curb and gutter is to be removed. 40. The Contractor' shall provide all the material and appurtenances necessary for the complete installation of the utilities. All pipe and fittings shall be inspected prior to being covered. 41. All handicap spaces are to receive a handicap sign and handicap symbol painted on the asphalt. Note stalls to receive 'van accessible' signage. 42. The Contractor shall refer to the architectural plans for exact locations and dimensions of precise building dimensions and exact utility entrance points. 43. Information concerning underground utilities was obtained from available records and field conditions r;hen possible, but the contractor must determine the exact location and elevation of all existing utilities by digging test pits by hand at all utility crossings well in advance of trenching. If the clearances are less than specified on the plans or 12 inches, which ever is less, contact the Project Engineer prior to proceeding with construction. 44. The Contractor shall include in his contract price the removal and disposal of any excess topsoil he determines is not required to perform the final grading and landscaping operation. 45. The Contractor is responsible for the design and implementation of all required/necessary sheeting, sh:;ring, and special excavation measures required on the project to meet OSHA, Federal, State and Local regulations pursuant to the installation of the work indicated on the drawings. Redco Properties, The Town of Chocowinty & Stocks Engineering, P.A. accept no responsibility for the design to install said items. Surveying: Barrow & Barrow, P.A. 115 Heritage Crossing Snowhill, NC 28580 252.747.5790 (v) 252.747.5111 (f) Contact: Steve Barrow, PLS Civil Engineering: Stocks Engineering, P.A. 3344 Hillsborough Street, Suite 250 Raleigh, NC 27607 919.821.2440 (v) 919.821.2210 (f) email: dcurry@stocksengineering.com Contact: Don Curry, PE Project Engineer 46. The Contractor shall include in the contract price daily record keeping of the as -built condition of all of the underground utilities, construction stakeout associated with the project. 47. All water line and sewer line installation shall conform to the standards and details of the State of North Carolina Department of Health Construction Permit. 48. The Land Disturbance Permit must be kept on the work site and shown upon request. 49. The Contractor shall include in the contract price all material and labor associated with the testing of the water and sewer lines required by the State of North Carolina Department of Health. 50. The Contractor shall include in the contract price any de -watering necessary to construct the project as shown on the plans. 51. Natural Gas service is not available at this time. 52. TESTING BY CONTRACTOR: Contractor shall employ at his expense on outside independent Soil Testing Service (approved by the Architect) to perform soil testing and inspection service for quality control testing during earthwork operations. Copies of results of tests shall be submitted by the Testing Service directly to the Contractor, the Architect, and the Structural Engineer. --The Testing 'Service will classify proposed on -site and borrow soils to verify that soils comply with specified requirements and to perform required field and laboratory testing. (Minimum required soil bearing capacity is noted on the structural drawings). --In paved and building slab areas, the Testing Service shall make at least one field density test for each 2000 square feet of fill in each compacted fill layer. If a test should fail to meet required density, the Contractor shall re -compact that layer. The Soil Testing Service shall perform additional tests at the Contractor's expense to show that the failed layer has reached the required compaction. --In foundation wall areas, the Testing Service shall make at least one field density test for each 100 feet or less of wall length of fill in each compacted fill layer, with no less than two tests along a wall face. If a test should fail to meet required density, the Contractor shall re - compact that layer. The Soil Testing Service shall perform additional tests at the Contractor's expense to show that the failed layer has reached the required compaction. 53. COMPACTION: Compact each layer of backfill and fill soil materials and the top 12" of subgrade in cut areas to 98% of mc;ximum density as determined by ASTM D698 for structures, slabs, and pavements and 90% of maximum density for lawns or unpaved areas. 54. The building contractor and the site work contractor to coordinate the installation of a drainage pipes around the building structure. 55. Any relocation of existing utilities will be at the cost of the developer/owner. The Town will not accept responsibility for damages to curb and gutter or street improvements installed prior to underground services, nor will the Town absorb the cost for borings to install underground service, pavement patching or damage to landscaping. These will be the responsibility of the developer/owner. 56. Fire department vehicular access to all structures under construction shall be provided at all times. In areas where ground surfaces are soft or likely to become soft, hard all weather surface roads shall be provided and maintained. 57. Address Numbers, both Commercial and Residential, must be posted on the front of the structure nearest to the main entrance in a position to be plainly legible, visible, and unobstructed from the street or road fronting the property. 58. Disturbed area is in excess of 1 acre and formal Sedimentation & Erosion Control plan approval was required as a condition of construction plan approval. A copy of the approved erosion control plan must be kept on site at all times. The approved Sedimentation & Erosion Control Plan should be regarded as minimum requirements; 9 additional measures shall be put in place as needed to ensure that no sediment is released from the site. 59. Copies of all permits and approved plans must be kept on site in a permit box that is conspicuously located and easily accessible during construction. This includes approved P Y Y 9 PP construction plans, approved erosion control plans, encroachment agreements, driveway permits, water/sewer permits, etc. BEFORE YOU DIG CALL TOLL FREE 1 800 632 4949 NORTH CAROLINA ONE -CALL CENTER yj 1' q 4 IAL "Y • _�aY\U0.V�Y _ ' �N. CARO7i 026970 V03 CUR�p��-11 / 17/09 Z ZI r, ro Q 0 �m�� • ,°a'a0o N V wvJ z V o¢o Z d w 0 w co W Z U wZ �w W N J J Zoa Z (H� V o W co NO� Z N O NNE W Ni. mmrn V) w�J Z �x0 U N 0 1 0 r o � N � LA L m U / J if1 = N = �wW CV=01 CHOCOW_INIiY / Z ro lb T S ci p N w LIFE, INC. / / HARRIETT HARDING DB 04E-PG 241 w P 01M C) \ \ �� <b/ c�� o ftftft -ftnuft BONNIE RAY QDB 819-PG 183 / PARCEL PLOTTED OP Q N\ V 1 PROPOSED 10' I � � I \ � V � � , A � � �± ► _ D AINAGEjZSEMENT PATRICIA & JOHN JONES � — — — Lu FJIu \ DB 1114-PG 482 � i DANIECO L & ELJZABETH BYRUM I� / . �� DB 1580-PG 151 PROPOSED 40' INGRESS, (GRESS, & w I /LINE I \ \ \ REGRESS — 20' (ACH SIDE I� '\ OF PROPERTY LLINE INE \w n W Q v� / m204021.5115 Sq. Feet±l 6o �V A ' I �u \ 4.684 Acres± c EXCLUDING RAW PyROPO ED SITE BY COMPUTER \� 1.8 AC � 32 5 \ f'd 7�4� ays wmn�a � \ � � v v uvoEe¢aod 3 •'y ¢7zsaeZ-m V V A urwxn.unJ'A- a� n 00 ,� m AA �� \V_ �� J• °k' micro — - A o� VD y,"a pm 3. 3,6 _ �. _—3"� 36� �w z X zm \ w F \ i a \ E so 3� - _ z R �oLj v z a _�.0 - 36, 5 _ 1I 1 � `� 6 LPS SUMEY I LC-071' b N 616135. )O50 7 (. 15Be O9.T11 L p 3 t m IJ6.91 0 Q co DB�1670PG�73 r �'� —� I SEAN & STEP -PG MELLOTT W DB 1668-PG 252 rn00 AN ONY ZITO � m� DB 7108-PG 260 z p10 < SO U a �. C A R0/ i Eg 0000000 lljl \6\ of N aoa I t 026970 = JO BARROW & BARROW, P.A. �vQP� I =N= x Q. ��/�hlu�l►UJ, 115 HERITAGE CROSS I N6, SNOW HILL, NC 28580 4\ _P SCALE: 1" = 40' %� Phone: 252-747-5790 fax: 252-747-5111m 0 40 80 100 120 C'o1 C. G S. 77-5 CJ / v+ . FES 3 \ — \l PATRICIA & JOHN JONES LINE PROPERTY \ LINE (1vrP.) � � I I � � DB 1 1 14—PG 482 ', % I \ (✓ DUMPSTER W/HOT k COLD ♦ \ \ \ jUl + WASHDOWN 8'-4 \ © / ` ` FES 1 BLOCK &BRICK \ \ 1 _ \ Si10REM�WAND R t{" HIGH SCREENING \ II TO MATCH Bi W 24" STD. �� I I FES 2 DRAIN CdeG 5 INV.=33. \ 1 tt I SHARED ACCESS DRIVE Y, A \ FOR FUTURE I / DEVELOPMENT 4 0 N 21�S9AOCE3 \ AEA LIGHTio, �1.000 / \ SINGLE HEAD 23' PROPANE �I SEE NOTE 2 20'R \ A \ 25 `4- WHITE 2.5'R `5•R PAINT (TYP.) 11iRD PVC- N DUMPSTER \ C \ f` HEAVY DUTY 2" WATER w WHITE PAINT STRIPE ° �( FLEXIBLE SERVICE INSTALL ON HD FLEX. SS POWER DE GAS PAVEMENT SPILL PVMT. AT INTERFACE G LINE BY PROPANE \ LIP (TYPJ PEDESTRUIN RAMP 3 R W/GONG: PVMT. k SUPPLIER \. / Y NOTE: 1.THE BACKFLOW PREVENTOR SHALL BE WILKINS MODEL #950, 2" AND 1" FOR DOMESTIC AND IRRIGATION LINES RESPECTIVELY, OR APPROVED EQUAL. 2. INSTALL 1,000 GALLON PROPANE TANK UNDERGROUND WITH 8" MANHOLE RING AND 4-5' RISER. FIRMLY ANCHOR IN GROUND TO PREVENT BUOYANT RISE. l jMENU BOARD J 5 \, CdcG S1 D.� 20' — - l HEAVY DUTY 2 fr _ PLANTER FLEXIBLE / \ CONFIRMATION PAVEMENT w -� �• i co 4' CONIC 3TR l4 STD. ALL HVAC TO BE LOCATED C&G U'\ \ \ FLUME (TYP.) ( ON ROOF TOP i ARCH. PLANS FOR ACTUAL BLDG D MENSIONS)�'\Yp {� > PROP. PROPERTY 5'R F / LINE (TYi PROP. INV.=32.10 � BOJANGLES� INv.=3a.25 PUNTER Uc�orn CONC.SIDEWALK 3,84% SF H/C SIGNS 500 GALLONFFE=37 00 H/C, VAN GREASE / 3 PLANTER/ _ BLDG. HEIGHT = 20' ACCES. ERCEPTOR \ \ \ 25' AREA LIG 24` 5TD.AREA PE PLANTER 010'x50s SPAC ' / I W/2' DW POLE CgG' J � INV.=32.00 4 WHITE�� BASE 400W DAL - \ TYP )� / HEAD METAL HALIDE FLAG I II�IIR I� PAINT ( \ (TYP:a POLE MP 75•R y \ Si H/�G RA ti (NOTE: ALL CO's ON / LIP TYP. �� 12,SPACES THIS PROJECT SHALLI --- \ _ .-- b 9.0 \ -- - ... - / LNEP(TYP.; Tl FOW7 1 ) (H ELSTO BE TRAFFIC RATED � 20'R C - I ) LOAD i i' UN(>ERGROUND�TELEPHON �i GPS SURVEY CON " ` )U J17 \ - / 2 WATER EA 600-AMPELEC -- — ,,,„ N = 645683 2165 SERVICE WR =o® �, L 'SERVICE J� E = 256803C.-4991 Sg s� CONC. EX. PROPE y C� -_ _ ._ _ �� 1 TRANSFORMER R7y Z=3237 - AFtvtAd ; 0 �, HEAVY DUTY ( d `� ' V HEAVY DUTY PARK " ". ° n FLEXIBLE PAD LINE \ (TYP.) - -,� LAT-35'30',�2.&296� t.jt:C`,',.J111•.I(7 FiBL,`i 0101C A �. 9 N \ , 'n w 5'o 2 BACKFLOW PREVENTOR � ...... ,.,.,, -` PAVEMENT MENT SEE NOTE #1) (TYP.) ° INSTALL c�1RB l PAVEM� \ ' \ �O / k^ rt- �i — _ 40' FRONT YARD FLUSH W/PVMT CONDUIT 5'R l I/ IRRIGATION BACKFLOW SETBACK �. / PREVENTOR SEE NOTE 1 l \\ i �1 ' 25' 15'R _�-' ` R21 4" WHITE 5`R - � _ _ 5 ti 24" STD.__... _. _.a_ ��� \ 2 D 4 ` _ SKIP LINES 10' TAPER OM 22 Si1 -' CkG \ CFO—— �� ACES i , 0 A 24" STD. 30 3 10 9 V TO 24" CkG � � ® � I _ - B I 2. 2" FORCE SEE SHEET D SEPTIC500 GAL 03 FOR _ \, r m " 9,.✓, 1 MAIN EX. FIBER-OPTIC 10: TAPER FROM, e e FES 4 30 STD. _ yr ` ^ MORE IN iORMATION ON �- 0 TO 24 CdtG' C&G-M - - _ STEP SS SYSTEM 3 I a ' /f 16' HIGH - _• - - - - - - ,_ _. _• \ � �-- - _ __ LINE *USE CARES � � _..... PYLON SIGN 25' AREA LIGHT '30 STD ' " W/2' D41 POLE -_' �YF FES 6 _- - CdcG TAPE METER \\ - g x25'. 30 R -.._. BASE 40OW DBL R� \\ IRRIGATION._ _; +` ---_. _..___. -- - - i,3, ! - / TAPER " - .,_ __ _ - _ _ --- F(a .....__ `a --- -- ._..._,._HEAD_ METAL fNALIDE., _ .__ _ _ -; ': ,�, ��// - - " METER 2 CHECK __._ -- - -j .S ... (TYP.) - -... _ VALVE...._.. _ _ 1 `FES 5 _ .?� TIE TO r ,/ 9?' \ 30 SAD. 20 R 20' `TIE TO -_ 2" SERVICE _ _ _ - _ .-,._ . -- WHITE / " 30 STD R EX, c _ 24_ EX.TAP OdcG----- �.,_ _ STOP BAR-_ — >. 3j..._,.' TIE TO - - . - .... 4" DOUBLE YELLOW'THERM.OPLASTI `� ..r , ,, " D(•_.- - -- - _ \ 1 DBL 4LLOW - TIE TO MINI -SKIP LINES _.. <. (I - - - �' 35 y ~f > SOLID ST IPS 4 - _ c c- EX. Y y - _ --.._ EX.- `^ WHITE THERMOPLASTIC'" Q MINI -SKIP LINES__ ov �- - - - _ o 'x25' TAPER -- - - _ENTRANC S)-- F.`,,,^ .,,�* .__.. ___. ro. \ � 3 ------___ _ ` c'\ o r ERADICATE EX. ISLAND GROS HATCH ERADICATE EX. ISLAND/6ROSSHATCH c = PAINT. — --- — — — B RAGAW LAIC E, _ - _ -- 6 o PAINT. INSTALL ARCED MAR I_NG TO \ __..._.._ - SIR - .. +'� /� `""..... - o POINT 2 WHITE THERMOPLASTIC V R I 'T �. # SOLID TURN -LANE LINE GPS SURVEY CONTROL _-t _-120 R/VVa — 8 _. 557050 N - 64 117 7711 6.8 PMC, ''IN(,' DBL 1 670= PG`8,73 i BEFORE YOU DIG CALL TOLL FREE 494E �Nn r)NIV ZITO NORTH CAROLINA j DE 1 li_)8-PG 262 ONE -CALL CENTER LONE-- -7'rJ5'26.3236" AROC7,'���. SEAN & STEPHANIE MELLOTT -" •Q q DB 1688—PG 252 s 026970 e o2 •.%`'};C I NEED:;: y ��`�. un►R11/17/09 SCALE: 1" = 20' 6 20 40 50 60 ' 1p rn ro Q � � M N� N � N z J Z �I 0xQo z wm � N Q N W ZU w Z �J W a = Z O Q I..� .- Z V 0 0 m Z � N O NNN W w N Nam. z IV. TxEn U 0 a�:2 N 0 L) 0 0 O a^ N '/, mof//�� U VV �' JOZ N =N0 �ww a�J M�Q MNK C=02 C. _G S• 77- / U NCDOT 840.14 PRECAST CONC. DI W/ TRASH RACK y ) TOP = 34.75 V� / TOP OF DAM 2 .ORIFICE INV. IN = 32.75 TOP OF DAM DRAINAGE LEGEND �� / 3x6 ORIFICE INV. IN = 33.80 \ m PROPOSED STORM/DRAIN LINE\ / (J0� / 34.75 12" RCP INV. OUT = 32.75 \ v ^1.5" O 33.75 34.75 F PROPOSED CU� INLET (CI) 2" ORIFICE ti J H nninn •��_ / V PERM. POOL ELEV. O 32.75 3 \.- z v o `, .a• N w N �� PROPOSED 2'x3• INLET C3 / Q / � z� FLOWABLE CONC. FILL NOTE: UTILIZE EXISTING EXCAVATED SOILS N 0 of � 02 PROPOSE FLARED END U V 2.000 PSI MIN. ; s 0 SECTION/(FES) / BOTTOM of POND 3z.z5 FROM ON -SITE SOURCES TO \ -182-- - EXI G CONTOUR / / ESTABLISH A CLAY LINER IN THE \ 178 PROPOSED CONTOUR / / BOTTOM UCTURE = 30.00 "DEEP POOL" PORTIONS OF THE WETLAND - THE FOREBAY INLET AND zaso PROPOSED SPOT MICROPOOL� FOREBAY 0 30.50 MICROPOOL AT THE OUTLET, THIS /ELEVATION / 10 WIDE 030.00 1 STORMWATER WETLAND PROFILE \ PATRICIA & JOHN JONES o LINER SHALL HAVE A MINIMUM � � SPILL LIP / CLASS A RIPRAP INFILTRATION RATE OF 0.011N/HR. DB 1 1 14-PG 482 0 EMERGENCY SPILLWAY INSTALL A MIN. 4 OF TOPSOIL ON \ / MAX. C/L ELEV. 34.7s SCALE:N.T.S. 1 8 8 / C-O3 TOP OF AREAS WITH THE CLAY LINER. \ N 34.75 3 .7 i o 0 - - z -3435 -- -- -- - - -- -- -- -- It 36 -- � E a V-DITCH BOTTOM 60 LF 25 33 \ ELEV 36.50 f / FES 3 12" RCP 32 0 0.26% 31 32.25 25 LF 323\ 30 6 30.5 12" RCP 4 ! INV3260 FES 2 / =.32 2S STORMWATER ® 0.30% FES 1 32.5 31 4:1 ` T DITCH /TO � 3132 WETLAND ; 32 � ti DIVERT OFF -SITE 33 DRAINAGE � 33 34 � `t 1 34 � t / 37.07 36 36 ' .0 35. 36.55 6.0 3 ti JR 36.77 �� 6.5 _ - 6.63 4 135 LFCA 6.91 �12" RCP 5 ®.30% 5 56 LF 36.41 �', RDL - - 64 12 135 LF 6" \6 0.26% " RCP �w PVC / 12" RCP 36.'�� 1111 36.83 1 ® 0.30% r Q 6. 5 35.60 35.82 36. 5 / 36.45 - - f-CL � 204021 .51 1 5 Sq. E eet± ss 3s.63 ss , ; 4.684 Acres 0 x EXCLUDING R/V�' I 35.76 Lw 3 .47 �i `L� 6.7 � 5.71 BY COMPUTER a coNc� X / Q FLUME ( ) 36.96 ALL HVAC TO BE LOCATED 6. 5 I ON ROOF TOP 36.95 (SEE ARCH. PLANS FOR 36.98 37.2 egg. j ACTUAL BLDG DIMENSIONS) PROP. { M75_�\- BOJANGLES' l 3 �" 3ss6� 3,847 SF 6. 2 36.3 36.9 FFE=37.00 BLDG. HEIGHT = 20' 439.901 6. 0 / 3 .56 6. 0 ', co \ 36.80 V� 3 .53 I 38.50 36.75 ' / 6.� 36. 0 SPILL � .90 0 ` \ �' 36. 36.401 220' LF 12" RCP' ® 0.26% 4:1 V-DITCH TO DIVERT O. F'_ SITE DRAINAGE Q uir 6 / V i a P01NT# 1 �� �� LI TYP. � �_�; � 8 +.. 6 ,ARrG: �` 36.75 ( }z ,. ' \ GPS SURVEY CONTROL - � 36.84 � � � � i EL£PKONE , N = 645683:27G5 E = 266.8030.9991 � 3 � � UNDERGROUND T �yAY,k _ 8" � _ 6 36.3 5032RRN UPDEGROUND FIiEfi OPTICCE35 0528.220N7LAT8f • ,.� INSTALL CURB t1' \ / l S '� FLUSH PVMT 36.6 6.44 36.54 - TER k.. ` 36.82 - .49 _ C 0R2, WA ED 1 36- �_ _ 7 35.55 o 36. 9 EOF Pcf an _ 36--"' 35 36� 5 36.5FO �I GE ' �9' /FES 7 FES,4 a '5 34 INV= 1.55 FES 6 Y E 6 35 INV=33.60 \ m o •� 1■ , _ 3) \\ 4.00 INV=31.8-.___._ _ - .._ . - .. _ - - - - - ----- 72 LF �- - 12" SDR21 WATER LINE 15" RCP N .. lL 1 fit -L- -- - -, t' N 0 0.50% V \.i 0 X m 1-6" R P 30 -- 33.25 --_ _-.. a 6 RAGAW LANE , - ., W SR 1142 Zz f \ E\\E ._ . PO ---_- _� UCONTROL S- z E6461557050 = 2568178.7711 0 0 Z=36°6 NCm y LA7=3530'3Z4, N o LONyYTO�'26.3236" N N ro -- -- W OXm ul PMC, IN �, - y .ap1O1'►�a� DB 1 670--PG 873 ,� - °`o���FE ARO�,'%,� SEAN 8c STEPHANIE MELLOTT 0 -- � 1 - / 3' --- -- - - I :�.Q,�° �'� DB 1 688-PG 252 (fi 0oz y1�Q / c 026970 \N -IONY ZITO M=a D� 1 i 08-PG 26(L. �q�V 9,,%%%11/17/09 SCALE: 1" - 20' 0 20 40 50 60 C=OVQ i t 66.25 DC. — / G i - EROS—I�Nt G8-NTRQ- LE6END LIMITS OF DISTURBED AREA / CONSTRUCTION ENTRANC\�O / �--�-- SILT FENCE ROCK/CHECK DAM / BLOCK & GRAVEL INLET PROTECTION I / / I FES 3 f I I l / / 1 1 �11 I / J. 1� Sri ► =i l J , / ROCK CHECK DAM (TYP.) ' I / POINTi 1 OO 7 � CPS SURVEY NTROL I N = 6456832165 E = 2568030.9991 �N Z=32 37-7 WARNING I . N W \ i O z \ J 41 O V 00,00 5 = \, PATNIOIA JONN JONES 0 N DB 1 1 14--PG 4-82 N N O z r� a 36 0 —32.5 32 \ FES 2 t 31 -3 32 36 - CAV ftftj INEZ I J t 2 w uu — Z oldWARNING: �IIDERGROUND TELEPNON\ LAT-35 30 "32.8298 �' V UNDERGROUND F1BER OPTIC i 'co �\ ON=77.05 28.2208'� ■ �� 6' i \ 7 �7 �- BLOCK &GRAVEL CONSTRUCTION -INLET-PROTECTION—\�\ ENTRANCE I .(TYP') \\ DAM TYP. FENC 'ROCK- ; ( 6 o CHECK ES 3 _ 0 v 6 36 �I. 5 � PVC" FO��EO FES 7 34 -; am _ ..„ .. ..... a .. _ i _ _ .. 34 1 P _ _ 35 �� —_ _.." _._._ _ FES 5 - — FES 6 _ _ w �� _. _ . - 12" SDR2am 1 WATER 1.1NE _ f' '— / _ -- j 7� / - / A BRAGAW LANEfn SR 1142 f:_ —- w z z O POI 7f` 2 o < Y W f 1 CPS SURVEY CONTROL H z / N 646155.7050 E = 2568118.7711 / 'ter m m 11 165'26.3236" N` \\ �� Lu Nam. oao _- v m. O S PMC, INC. 670—PG" 873 2�y �j .� �� '� 1 ����o•..•••••� Si AN & STEPHANIE M�-LLOTT �oz -- DB, 1 ; m / -- --- -- a'�Q�EES' 9: DB 1 688—PG 252 AL a - � Q• F = 026970 � mm� aN HONY ZITO ' / DE 1 08—PG 26C ,���'i��N L CUR�.``I1/17/Os SCALE: 1" = 20' /� 0 20 40 50 60 3( 3- 32— �36 \ 4 l ALL HVAC TO BE LOCATED ON ROOF TOP & SCREENED FROM PUBLIC RIGHT OF WAY (SEE ARCH. PLANS FOR ` ACTUAL BLDG DIMENSIONS) PROP. BOJANGLES' 3,847 SF FFE=37.00 BLDG. HEIGHT = 20' 30 : 32.5 3 STORMWATER 31 MANAGEMENT 6 J t w wz Z w TEE A B C 8'XB'X6' -2'0 - I'D' I'D' 8'X8'X8' 2'4' t' ' 116' 12'X12'X6' 2'4' -I'0' 1'6- 12'Xl2'X8' 2'6' 110, 1.6- 12'X 2'%t ' 1'6' ' 0' % •X . 16'XI6'Xl2' 16'X16*X '10' 2U'X X6' TOP WITH READER LID i RIGHT OF WAY VARIES I IP/FLARED CONNECTOR NO 15425 7 4' T R CONNECTOR PLAN VIEW (TOP REMOVED) r� i I OR APPROVED EQUAL P THRUST COLLAR R I ICOM 5/16' 7 I 8' 5/16' I 1 METER FROM CITY ONLY 1 5 16' I I 11 x( I N 5' MIN 5' MIN ^j I I my m I FINISHED GRADE I _ kIV 1 1/8' (U C---- _3 VATER ♦_� i 1 s `� I III 4 5/8II 7/16' I I '--I F---CONCRETE THRUST BLOCK 7/16'--i I -- FA I I METER BOX III I I AT ALL 45 DEG. BENDS 24'x 36' POLYMER CONCRETE o TOP WITH SKID RESISTANT 6' iv 3/4' THREADED 1 1/2' OR 2' TYPE K SOFT COPPER SURFACE, STAINLESS STEEL BRASS CLAMPING DEVICE- N USE LIFT PINS, & SELF CLOSING INCLUDED IN METER BOX ASSEMBLY. 7-6 /4' 1/4' STEEL PLATE STEEL RODS SECTION A -A HOLE EACHOEND 6' x 9' READER LID 3/4' OR t' TYPE K, COPPER 0� SERVICE PIPE PER ASTM B-88 GRAIN HOLES NOTE, ROD REQUIREMENTS 2' IRON BODY, BRONZE MOUNTED • 11' 1. VALVE BOX SHALL BE TELESCOPIC ,y. .a GATE VALVE WITH BOX & SHOULDER CURB STOP-INCL. IN WITH SCREW TYPE ADJUSTMENT. SLAB PER STD. NO. 5.9 METER SO ASSENBLT APPROX. l CU FT. CRUSHED SIZE OF 45 DEG. BEND STATIC THRUST IN POUNDS NUMBER OF RODS REQUIRED STOVE AROUND BASE t----- 2. VALVE BOX SHALL BE CAST FROM 30, IN. ASTM A-48, CLASS 30 IRON & SHALL 6' 4,328 2 N BE FULLY BITUMINOUS COATED FOR TAPPING SADDLE PER T-14.15.4 Nam. DIRECT BURIAL, 12' 17,312 2 NOTEsI 6'MIN. 1. METER BOXES ARE TO PLACED IN TURFED AREAS. 3. VALVE BOX SHALL BE VBX-TE-3B AS 16, 30,779 4 #57 STONE 2' TYPE K SOFT COPPER CORP. STOP BY MUELLER 2. ALL METERS SHALL READ IN CUBIC FEET. MANUFACTURED BY DEWEY BROTHERS, 20' 48,091 6 NO. H-15175 OR HAYES 5040 3. METERS SHALL BE PURCHASED FROM CITY OF ROCKY MOUNT ONLY. 3/8, 1 [U INC. OF GOLDSBORO, NC OR APPROVED 24' 69,252 8 NOTES BY-PASS WITH LOCKABLE BALL VALVE 4. ALL CORPORATION STOPS, CURB STOPS, END CONNECTORS, ETC, SHALL EQUAL. 1 BE SOLID BRASS MANUFACTURED IN ACCORDANCE WITH AWWA C800. 3. METER SETTER SHALL BE MANUFACTURED BY FORD METER CO. DIRECT TAP ON 4- DIAMETER OR 5. STANDING IN STREET FACING HOUSE, WATER METERS r 11' 4. FOR INSTALLATION DETAILS, SEE 1. ONCE INSTALLED AND TIGHT, THE STEEL RODS AND BOLTS SHALL BE - - - OR AN APROVED EQUAL AND SHALL BE AS FOLLOWS LARGER DIP OR CIP MAINS ONLY. ARE TO BE LOCATED 3' RIGHT OF SEWER STACK, STD. NO. 5.10. COATED WITH 2 COATS OF BITUMINOUS BASE PAINT. 2. VAULT TOP & FRAME SHALL BE MADE OF 11,000 PSI ALL OTHER TAPS SHALL BE MADE FIBER & POLYMER REINFORCED CONCRETE. VAULT METER SIZE METER TYPE SETTER MODEL NO. VITH SOLID BRASS, TWO OR THREE 6. METER BOX SHALL BE FORD CRESCENT BOX (MODEL CB111-233 FOR PIECE SERVICE SADDLES COMPLYING 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL SHALL RAVE MIN. DIMENSIONS OF 24' WIDE X 36' 1 1/2' DISK VV76-IOD-11-66 5/8' X 3/4' OR FOR I') AS MANUFACTURED BY FORD METER I---6 7/8'---I JOINT BENDS. LONG X 30' DEEP & SHALL BE MODEL # WAOO-2436-30C 2' DISK VV77-ISB-ll-77 WITH AWWA C800 BOX CO. OR AN APPPROPRO VEED EQUAL MODEL. BY CDR SYSTEMS CORP., QMOOED # BH30 BY STRONG WELL, INC,, OR AN AN APPROVED EQUAL. STANDARD VALVE BOX STANDARD VERTICAL BEND 5/8" x 3/4" & 1" WATER SERVICE REVISIONS APPROVED S D. NO. REVISIONS APPROVEDSTD.NO. STANDARD WATER METER VAULT (1 1/2" & Z") REVISIONS APPROVED STD. NO. DATE REVISION 5.1 I R PH MN��d 5.771 DATE REVISION 04-07-00 - DATE Is N 2-19-01 5.5 04-07-00 DATE REVISION 04-03-03 APPROVED METHOD FOR EXTENSION STANDARD VALVE BOX GRADE 3'6' MIN. NOTE, MECHANICAL JOINT TAPPING SLEEVES SHALL HAVE A WORKING OF VALVE BOX TOP SECTION ABOVE TOP OF PRESSURE OF NOT LESS THAN 200 PSI HAVING RIGID CAST DUCTILE OVER UNDERGROUND CLAMPS AS PIPE IRON BODY SUITABLE FOR INSTALLATION ON BOTH DUCTILE IRON PIPE MANUFACTURED BY STELLAR CORP. OR EQUAL SIZED CAST IRON PIPE WITH OUTLET FLANGES PER ANSI/AWWA CIIO/A21.10 - - - APPROPRIATE TO VALVE. SPECIFICATIONS. THE VALVE SHALL BE MANUFACTURED TO AWWA CLAMPS BOLTED TO STEEL SPECIFICATION CLASS 350, OPEN LEFT. RODS. LUSE 5' HEAVY WEIGHT PAVEMENT CAST IRON SOIL PIPE 1 °*,,AND STANDARD STAB -IN SOIL FOR EXTENSIONS A VE BO% 3" PIPE CASKET V 1 SOLID CONCRETE OR BRICK VALVE BOX PVC PIPE PVC PIPE ---- '1 BLOCKING SHALL BE USED BOTTOM SECTION 1 AS FOOTING FOR DUCTILE NOTE, EXTENSION OF VALVE BOX USING STRAIGHT PIPE O �a t` IRON PIPE SHALL ONLY BE PERMITTED TO A DEPTH OF SIX (6') FEET. VALVE FOR DEEPER VALVE INSTALLATIONS, STEM AND OPERATING BOX ' •' NUT EXTENSIONS MUST ALSO BE PROVIDED. 3/4' THREADED STEEL .I. A RODS \ PLAN OUTSIDE PAVEMENT INSTALLATION TAMPED HACKFILL� CLASS A TAPPING v v v v CONCREUSE TE PSI S'�CTI❑N CONCRETE -O - VALVE BO% NOT ° v' ° TO CONTACT FOOTINGS \ / SLEEVE 6' MIN. - v .w °-v' _ MAIN NOR VALVE / VALVE THICKNESS 3 NOTES ° A 1: CONCRETE SHALL NOT CONTACT BOLTS'_:,. .° 2 OR ENDS OF MECHANICAL JOINT FITTINGS. a L .. �'--�--i 2. SEE STANDARD THRUST BLOCK TABLES, 4 v v v. v� r FOR AREA OF CONCRETE REQUIRED. ' 1 1\ , o I IN PAVEMENT INSTALLATION S. 3' 3- 5' L RODS SHOULD EXTEND TO TOP OF PIPE CROWN. 3. COAT EXPOSED STEEL RODS 3. 2500 PSI CONCRETE CLASS B REQUIRED. r: EXITING O O I ) °o - W. MAIN - VALVE W MAIN 2. X x Y MUST EQUAL THE SQUARE FOOTAGE OF AND CLAMPS WITH 4. TAPPING SLEEVE & VALVE SHALL BE BOLTED ' 4 MAIN `✓ WATER .o v 2' .. THE AREA AS SHOWN IN THE TABLE BELOW, BITUMINOUS BASE PAINT. IN PLACE & PRESSURE TESTED PRIOR TO .�. I '. v.- v v vv '° BEARING SURFACE AREA FOR VALVE FOOTINGS TAPPING OF EXISTING MAIN. 4 ° v .V. v..v ' 2500 P.S:L CONCRETE NOTE: 12M I CLASS B SHOULDER SLAB COMPACTED SUBGRADE� THIS STANDARD IS I T USED FOR PVC SEWER REQUIRED 'D CE M INS OR PRIVATE TER SERVICE A PLAN r R A WA ONLY. TAPPING SLEEVE & VALVE VALVE BOX INSTALLATION DETAILS VALVE FOOTING BEND & BLOCKING OF 45- BENDS nFRr.RTPTTnNR VISIONS A _ ED _NO PAT9 DESCRIPTION REVISIONS APPROVED STD.NO. NIT hATF15.12 REVISIONS APPROVED STD.NO. R VISIONS APPflOVED STD. NO. DATEEVISON 5.10 - 5.14 5.22 04-04-06 DATE REVISION ATE REVISION DATE REVISION 04-07-00 04-07-00 07-13-01 TO ABOVE TOP OF MIN. NOTES - GRADE •� ----- GENERAL NOTES: PIPE 1. MIN. GRADE FOR 4' SEWER ,p _ r I- 1. REINFORCED CONCRETE SECTIONS SHALL BE MANUFACTURED IN ACCORDANCE WITH ACT 318. LATEST EDITION SERVICE SHALL BE 1.0 Y. (1/8' AND BRAD., HAVE 80 EST MIN. TENSILE STRENGTH REINFORCING STEEL AND 4.000 PSI MIN. COMPRESSIVE STRENGTH CONCRETE. PER FT.) RECOMMENDED MIN, • GRADE SHALL BE 2.0 x 1 I I I 2. ALL PRECAST CONCRETE MANHOLES SHALL BE MANUFACTURED IN ACCORDANCE WITH AC 478. LATEST STR ET O I I EDITION. 2. DEPTH OF SERVICE AT C/L R/W II = 3. ALL PRECAST CONCRETE VAULTS SHALL HB MANUFACTURED IN ACCORDANCE WITH ASf1I C 857. LATEST PROPERTY LINE MUST BE VARIES <_ _ _ _ _ JI LI _ _ _ J EDITION. SUFFICIENT TO PROVIDE AT LEAST MIN. GRADE TO A 4. ALL MANHOLES, VAULTS. AND CASTINGS EXPOSED TO VEHICULAR TRAFFIC SHALL BE DESIGNED TO WITUSTAND BUSINESS OR DWELLING AND l2' MIN. H.---� L- -1 L AASHTO H-20 LOADINGS. 18' MAX s' I s I I I 12' MIN. COVER OVER SERVICE. -_ - - -_ x 1 i� U 2 EA. C.I. FRAME & COVER PER STD. 6' 4'-3' 6' 4'-3' 6' 5. JOINTS BETWEEN PRECAST CONCRETE SECTIONS SHALL BE SEALED WATERTIGHT USING EITHER 0-RING 3. FOR NEW SUBDIVISIONS, I q~q ' + z DWG. NO. 4.6 SECURED WITH MORTAR GASKETS CONFORMING TO ASTM C 443 OR BUTYL RESIN CONFORMING WITH AASRTO M 198. E� ,�° // _ w CLEANDUT STACKS SHALL BE ^ + I N >r 6. A MINIMUM OF SIX (8") INCHES OF CLEAN, WASHED, GRADED STONE MIX SUCH #57 OR #87 SHALL BE PLACED 3' TO THE LEFT OF I $ C '1 B ~ PROVIDED FOR SETTING AND LEVELING PRECAST SECTIONS. THE WATER METER WHEN I w 4 LOOKING FROM THE ROADWAY i 7. ALL COMMERCIALFOOD HANDLING ESTABLISHMENTS SHALT. BE REQUIRED TO HAVE AN OH. 4' 1/4 OR 1/8 BEND MONOLITHIC 'Y' W/ /GREASE OR SEWER MAIN. I c v{d=sca =a.^; INTERCEPTOR ON SITE. THE INTERCEPTOR 9HATL NOT BE PLACED WITHIN PUBLIC RIGHTS OF WAY OR I/4 BEND FITTING PASEYENT'S. PLAN FLOW 12' MIN 4. ALL SERVICES SHALL HAVE A 8. THE REQUIRED CAPACITY FOR OIL/GREASE INTERCEPTORS SHALL BE BASED ON TWENTY GALLONS PER CLEANDUT PLACED AT THE EASEMENT SECTION RESTAURANT SEAT. BUT SHALL NOT BE LESS THAN A MINIMUM OF FIVE HUNDRED (500) GALLONS. WHERE OR RIGHT OF WAY LINE, ALL CLEANOUTS \ (I •6,: p ON -SITE FOOD PR1' STUB W/PLUG EPARATION OR DISH WASHING OCCUR. A MINIMUM OF ONE THOUSAND (1000) GALLONS OF SHALL BE CAST IRON WITH BRASS CAPACITY SHALL BE PROVIDED. ADDITIONAL FLOW AND STORAGE CAPACITY MAY BE REQUIRED WHERE A PLUGS CAST IRON DOUBLE -HUB SUBSTANTIAL PORTION OF THE FOOD PREPARED IS NOT CONSUMED ON SITE (LE.: 'DRIVE -THROUGH,' CONNECTORS (30' MIN.) MAY BE USED TO C 1 C\/ n T T n N I ': S TAXE-OUT." OR DELIVERY SERVICES.I 2500 P,S,I. CONCRETE CLASS B REQUIRED NOMINAL DIAMETER A B C TRENCH WIDTH 6' 1'4' 1'0' 1'2' 2'6' 8' 1'6' 1'0' 1'4' 2'8' 12' 2'2' 1'0" 2'2' 3'0' 16, 3'0' 1'O' 2'8' 3'4' 20' 4'0' F6_ _3'0' 3'8' 24' 5'0' _2'0' 3'6' 4'0' 30' 6'6' 2'6' 4'2' 4'6' nn>4i wry FROM PVC SERVICE v 4' MIN. :', RCE PIPE. 4' CAST IRON ILL PIPE OR 4' DUCTILE IRON 5. ALL PVC FITTINGS SHALL BE OF /TI 4' PVC (SDR 23.5 OR SDR 26) N MONOLITHIC 'Y' W/ °t HEAVY WALL CONSTRUCTION (115 PSI a 12 12 MIN. PIPE STIFFNESS.) ;;?'., 1/4 BEND FITTING NOTE, FOR GENERAL CONSTRUCTION NOTES, 6. ALL PIPE WITHIN RIGHTS OF WAY HAND SHAPED, STABLE SUBGRADE REFER TO STD. NO. 4.18. SHALL HAVE PUSH -ON JOINTS WITH SEWER MAIN EXCAVATED TO CONFORM TO PIPE ELASTOMERIC GASKET SEALS. AND BELLS OR HAND PLACED CLEAN, WASHED STONE (2-3' OF NCDOT #67> 6' MIN. CLEAN WASHED 7. SIX INCH AND LARGER SERVICES WELL COMPACTED SUBGRADE STONE BEDDING SHALL CONNECT AT MANHOLES. (95X MIN. STAND PROCTOR) (NCDOT #57 OR EQUAL) OIL/GREASE INTERCEPTER (1000 GALLON & LARGER CAPACITY) NOTES FOR OIL/GREASE INTERCEPTORS STANDARD 4" SERVICE LATERAL TRENCHING & BLOCKING OF TEES REVISION APP D STD. NO. REVISIONS APP OVED STD.NO. REVISIONS APPROVEDNO. R VISIONS APPROVED STD,N . - 4117 4'18 4.12 5.24 DATE REVISION NEVIS ON DATE REVISION DATE RE ISION O1-30-03 - 01-31-03 - 04-06-04 - 07-13-01 - TEE A I B C 24'X24'X6' 2'6' 118' 2'6' 4' ( 4' ( 2' --I.8• 2'6' 4 X V 2 24'XI 9' '0' '0 2' 30'X3O'X6' L161 1'8' TV 30'X30'X8' 216' Ile. V 30'X30'XI2' 2'10' 118' 3'4' ' O'XI6' 3'6' I'l0' 31w O'X30'X '0' 30' . S'c ceLt 026970 (� �0, .F,yCINEE(;:'•�p•,` D L. 11/17/09 rn rn Q � I W � ■ (V? N w�Lj z V =XO Z aW� Z� w W Z U Z W W <J W J Z O E Irnl z V Z Na� INo "N00 I W (p W - mNrom /V^ mom w Z J O j�CO U =QO aW� N 0 � o 1 0 Ir` o Of N 'FI w U Q Z JL0 _ = N S U .}WW Q = J N)DQ ,7NK D=01 _ % wT_'T'TT.-•-- I(T )� )iR+ i r.1. I MOUND AND CONCRETE (TYP.) w wo 6'-0" PLAN 2-18" #5 DOWEL ANCHORS IN ASPHALT SECTION WHEEL STOP SCALE: N.T.S. 1/2" TOOLED EDGES 3/4' 1 VARIES 1/4"/FT. & VARIES 3000 PSI CONC. EXP. JOINT FILLER 4" 3000 PSI. W/ SEALANT CONCRETE SIDEWALK EXPANSION JOINT (30' SPACING MAX.) NOTES: 1. CONCRETE SHALL BE 3,000 P.S.I. 2. CONTRACTION JOINTS SHALL BE SPACED AT 5' INTERVALS. 3. FINISH ALL CONCRETE WITH CURING COMPOUND. 4. INSTALL 1/2" JOINT FILLER AND SEALANT WHERE CONCRETE SIDEWALK ABUTS TO 24" CONC. CURB & GUTTER. 6 CONCRETE SIDEWALK D-02 SCALE: N.T.S. 6 CONCRETE TO BE 6 CONCRETE TO BE AIR —ENTRAINED AIR —ENTRAINED LOW SUMP 3,000 LOW SUMP 3,000 g" PSI ® 28 DAYS 6^ PSI ® 28 DAYS 0 12 12,------------ 5.. 5.. 30" 24" 30" SPILL LIP 24" SPILL LIP NOT TO SCALE NOT TO SCALE 8'-4" HIGH ?LOCK & BRICK SCREEN WALL (SEE ARCH PLANS) d 6,"°°' BOLLARD ° `DRAIN > s STORAGE 0 a A V P; BUILDING a O ¢ I , .. n d ♦ <. a w.. ;. ° d d , e' d a 4 ° 35' 4 a i s 4 a 4 ° . • d' a a n d o at 4 ° °. d d d. , a4:4A4 °a d a d vi, <N .. , 4♦ - n. 9 •d ,d a. • , d n i d a a • 4, 4' � Q• -4 d -4 m DUMPSTER PAD SCALE: N.T.S. 6 ONCRETE TO BE 6 CONCRETE TO BE AIR —ENTRAINED AIR —ENTRAINED I� LOW SUMP 3,000 LOW SUMP 3,000 E6" PSI ®28 DAYS 6" PSI ® 28 DAYS 12 7.. 12 7.. ". 30" 24" 30" C&G 24" C&G NOT TO SCALE NOT TO SCALE NOTE: USE 30" C&G WITHIN NCDOT RIGHT—OF—WAY 6" THICK CONC. DUMPSTER PAD — 4000 PSI CONC. ® 28 DAYS 4" WHI STRIPE 2 D-02 CURB AND GUTTER SCALE: N.T.S. L CONCRETE SIDEWALK ? 12" WHITE STRIPE o J TE (TYP.) o� 9'-0" 9'-0" 8'-01, 8'-0" ~�� VAN �T� ��� VAN PAINTED H/C ACCESS STALLS 4" WHITE STRIPE 7 90 HANDICAP STALLS — TYPICAL D-02 SCALE: N.T.S. PAINT 12" R7-8 or R7-8a RESERVED PARKING GREEN 0 GREEN `O 6" DIA. STEEL PIPE BLUE00 z FILL W/3000 PSI WHITE SYMBOL CONCRETE. V) WHITE BACKGROUND Lu CONCRETE ISLAND MAXIMUM R7-8D o> PENALTY 1625o VAN —ACCESSIBLE SIGN AT VAN o SPACE ONLY s VAN N �� ACCESSIBLE NOTE: HC SIGNS TO BE MOUNTED ON BLDG 24" DIA. CONC. AT LOCATIONS SHOWN ON PLANS. ENCASEMENT (3000 PSI) 3 R7-8 HANDICAP SIGN 4 BOLLARD D-02 SCALE: N.T.S. 1,,DD102 SCALE: N.T.S. ASPHALT CONCRETE PAVEMENT SLAB v0 0 00°0 Q0, .c oo no. n op n c 4 ° O O O000 QOg 00 QOg 00O Oo OQO°_..�I— o - 11 0 o 0 0 0 0 p o g o — o 0 0 0 0° 0 o° o o ° ° _ ° ° ° 8 0 0 $ o _ J o goo g`o o co 0 0°o'°ov000 °o °oa o°e o ° ° % .o =Q' o 00 0 °00 ° o vo - 0 o o Qo °o o °o o G o °Q _ -� 11 I, .III 111_ 12" 4" 12" COMPACTED � � 4" CRUSHED AGGREGATE SUBGRADE COMPACTED BA:c COURSE SUBGRADE 8 6" CONCRETE/BITUMINOUS PAVEMENT INTERFACE D-02 )SCALE: N.T.S. = CONC. CURB It 1�GUTTER 1/2" EXPANSION JOINT 5'-0"� SECTION A —A A 1 2" EXP. JOINT A L AROUND o a I T II A 24" CURB & 5' 5' 5' GUTTER NOTES: 1. THE WALKING SURFACE SHALL BE SLIP RESISTANT AND A CONTRASTING COLOR TO THE SIDEWALK. 2. WHEELCHAIR RAMPS SHALL BE PROVIDED AT LOCATIONS AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. 3. CONCRETE SHALL HAVE A SIDEWALK FINISH IN ORDER TO OBTAIN A ROUGH NON—SKID TYPE SURFACE. 4. A 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE CONCRETE WHEELCHAIR RAMP JOINS THE CURB AND AS SHOWN ON THE DETAIL, THIS SHEET. 5 WHEELCHAIR RAMP D-02 SCALE: N.T.S. INLET # CATCH BASIN TYPE GRATE TYPE ROADWAY RIM ELEV (EOP) PIPE SIZE (in) & INV. IN PIPE SIZE (in) & INV. OUT 1 NCDOT STD. 840.02 TYPE 'E' BOJANGLES 35.13 N/A N/A 12 33.08 2 NCDOT STD. 840.02 TYPE 'E' BOJANGLES 34.72 12 32.51 12 32.51 3 NCDOT STD. 840.02 TYPE 'E' ACCESS RDWY. 35.95 N/A N/A 12 33.70 4 NCDOT STD. 840.02 TYPE 'E' BOJANGLES 35.63 12 33.30 12 33.30 5 1 NCDOT STD. 840.02 TYPE 'E' BOJANGLES 35.63 12 32.89 12 32.89 10 D-02 DRAINAGE TABULATIONS SCALE: N.T.S. N lam"--JtHL �VE• 026970 O0 *.FNGINEE(;:'���•�: 11/17/09 Wco r Q co ymw li Llj =J Z V �XO Z a�� 1-4 l Q W Z V Z W w Nw J Z oQ Z V `� o Z NO NN°° W '0� pN— ,m rn ul w J Z �x0 U a.�M 0" O o 0 o x N m V V� JOZ N =N= ,r ww aPJ D-02 CONTROL PANEL MOUNTING PLATE FOR CORD FITTINGS ACCESS HATCH MOUNTING PEDESTAL —,TOP RAIL SUPPORT (DIRECT MOUNT PANEL) SST rJUNCTION BOX I (REMOTE PANEL) SEAL Y OTHERS) VALVE EXTENSION HANDLE 1 1/4' ANTI -SIPHON VALVE, PVC (AS REQ'D) O GUIDE RAILS, 1" PIPE, 4" INLET PIPE SCH. 10 OR 40 (BY OTHERS) INVERT ELEV.=32.00 DISCHARGE LEVEL ATER "ALARM" ELEV.=31.50 -' UFTOUT CHAIN, 1/4" ,G PUMP "ON" ELEV.=31.25 ' LIFT BAIL, SST (AS REQ'D) PUMP "ON" ELEV.-31.00 ' 1 1/4" DISCHARGE PIPE, PVC -- — -.- - -- ^ SCH.80 (BY OTHERS) CONCRETE WETWELL� MEYERS WGL20 MYERS 5RA-125-CV" UFTOUT 2HP GRINDER PUMP (W/CHECK VALVE) BOTTOM OF MH ELEV.=29.00 �t 1 PUMP STATION DETAILS D-03 SCALE: N.T.S. HIGH MARSH Botanical Name Common Name PERMANENT POOL Botanical Name Common Name Herbaceous Plants Asclepias incarnate Swamp Milkweed Floating Aquatic Plants Lemna spp. Duckweed Carex spp. Sedges Nuphar polysepalum Spatterdock Chelone glabra White Turtlehead Potamogeton spp. Pondweed Crinum americanum American crinum lily Spirodela polyrhiza Duckmeat Crinum erubescens Swamp lily Wolffiella lingulata Bog mat Dichromena latifolia White Star Grass Eupatorium coelestinum Wild Ageratum Submerged Aquatic Plants Eleocharis acicularis Spikerush Eupatorium dubium Dwarf Joe Pye Weed Elodea spp. Waterweed Eupatorium fistulosum Joe Pye Weed Isoetes spp. Quillwort Eupatorium moculatum Lilaeopsis occidentalis Lilaeopsis Eupatorium purpureum Najas spp. Naiad Helianthus angustifolius Swamp sunflower Zannichellia palustris Horned pondweed Helianthus verticillatus Hibiscus aculeatus Pinelands mallow LOW MARSH Botanical Name Common Name Hibiscus coccinea Scarlet rose mallow Emergent Plants Alisma spp. Water plantain Hibiscus dasycalyx Neches River mallow Acorus spp. Sweet flag Hibiscus grandiflorus Velvet mallow Alopercurus howellii Foxtail Hibiscus moscheutus Rose mallow Canna lily 'Bengal Tiger' canna Hymenocallis eulae Spider lily Cladium jamaicense Sawgrass Hymenocallis liriosme Spring marsh spider lily Cyperus aristatus Flat sedge Hymenocallis pygmaea Dwarf Spider Lily Iris hexagona Hexagonal iris Hymenocallis traubii Traub's Spider Lily Iris nelsonii Nelson's Iris Kosteletskya virginica Seashore Mallow Iris prismatica Slender Blue Iris Lobelia cardinalis Cardinal flower Iris virginica Blue Flag Iris Lobelia siphilitica, elongata, Iris versicolor Blue Flag Iris and allies (Blue Lobelia) Iris fulva Copper Iris Saccharum giganteum Juncus effuses Softrush and allies (Plumegrasses) Leptochloa fasicularis Salt —meadow grass Zephyranthes atamasco Atomasco Lily Ludwigia spp. Primrose willow Oryza sativa Rice Shrubs Alnus serulata Hazel alder Peltandra virginica Arrow Arum Aronia arbutifolia Red Chokeberry Plantago major Common Plantain Cepholanthus occidentalis Common Buttonbush Pontederia cordata Pickerelweed Clethro alnifolia Summersweet Sagittaria latifolia Duck Potato Corpus amomum Silky Dogwood Sagittaria lancifolia Bulltongue Cyrilla racemiflora American Cyrilla Sagittaria longiloba Arrowhead Gordonia lasianthus Labially Bay Saururus cernuus Lizard Tail Hypericum densiflorum Dense Hypericum Schoenoplectus tabernaemontani Hypericum prolificum Shrubby St.Johnswort Scirpus americanus Three —square bulrush Ilex decidua Possumhaw Zizania aquatica Wild rice Ilex glabra Inkberry Zizaneopsis miliacea Water millet Ilex verticillato Winterberry Itea virginica Sweetspire Kalmia angustifolia Lambkill Kalmia Magnolia virginica Sweetbay Magnolia Rosa palustris Swamp Rose Sambucus conadensis Vaccinium crassifolium Elderberry Creeping Blueberry Viburnum nudum Possumhaw Notes: Trees Asimina triloba Common Pawpaw Wetland shall contain the following minimum quantities and plant sizes Betula nigra River birch (plants ® 50 per 200 SF, shrubs ® 8 per 200 SF): Carpinus caroliniona Ironwood • herbaceous plants of at least 4—inch container => QTY = 600 Diospyros virginica Common persimmon • shrubs/small trees of at least 1—gallon container => QTY = 96 Franklinia alatamaha Franklinia • tree of at least 1.5" dbh bare —root or balled and burlapped => QTY = 0 Nyssa biflora Swamp blackgum Wateratica (B&B) material Taxodiuso mudist chum Baldcyp cypress 2 D-03 WETLAND PLANT LIST SCALE: NTS T 2. , 3. •. ••' •''' •''' •. 3 D-03 STORMWATER WETLAND AREAS SCALE: N.T.S. PVC W TYPE SUNC X 2 I.G. t STUD �'D. TYPICAL INSTALLATION 48" DUPLEX 2HP GRINDER PUMP PACKAGE W/ SRA-125-CV LIFTOUT CONCRETE BASIN PUMP MODEL: WGL20 ULe1WI67 LEGEND H10H MARSH LOWMARSH 0 00 sf / , 'I.I.■I.■I.■■" ' 11/17/09 w Z g V �w � N Z J tO Q Cn =O Za V O W � z Q LJ ,j W O ca 00 Q N � � N N .Ni W vJ z 0xQo z u WM a� W Z Z WZ W 0J 0> Z 8Q V o � z N on W N O NNM N i. (,A1 rnmrn V/ W � J Z p X V =Q0 0� o 1 N L m U JO Z = N � � W W sh~J M N D-03 EROSION AND SEDIMENTATION CONTROL NARRATIVE PROJECT DESCRIPTION The purpose of this project is for construction of streets and utilities for Bojongles Site Development The project Is owned by Redco Properties, LLC. The site is currently undeveloped. Approximately 2.15 acres will be disturbed during construction. The maximum fill will be 2-3 feet. The project is scheduled to begin construction in Spring 2010 with project completion and final stabiliza-tion by Summer 2010. The erosion and sediment control program for this project will include the installation of a suitable construction entrance, silt fence, outlet protection, inlet protection, check dams, and sediment basins with temporary seeding of the site. ADJACENT PROPERTY See Existing Conditions plan, sheet C-01, for adjacent property owners. SOILS The soil at this site is a sandy clay. EROSION AND SEDIMENT CONTROL MEASURES All vegetative and structural erosion and sediment control practices shall be constructed and maintained by the contractor according to these plans and specifications and the minimum standards of the NC Dept. of Environmental Management, Land Quality Section. The contractor shall also follow any additional requirements as outlined by the Project Engineer. Structural Practices 1. Vehicle wheels shall be clean when leaving the site to prevent the tracking of mud on paved roads. 2. Construction Road Stabilization: Construction traffic shall be limited to stabilized areas. At a minimum, a temporary gravel construction entrance shall be provided as shown on this drawing. 3. Silt Fence: Silt fences shall be provided where shown and as needed on the site plan. These barriers shall be used to contain sediment. 4. Rip Rap/Gravel Filter Sediment Basins: Construct basin to the shape and dimensions shown in the details. The basin is to be placed below the existing ditch flow line by 2' with the berm built above as dimensioned. Vegetative Practices Temporary Seeding: All denuded area or areas to be grade within 15 calendar days shall receive temporary seeding within 15 days of completing initial earthwork. Temporary seeding shall also be used to stabilize finished grade areas if the time of year is outside the specified permanent seeding periods. Temporary seeding shall be in accordance with temporary seeding specifications. Management Strategies 1. Perimeter measures are to be installed prior to grubbing or grading. 2. Tail Ditches shall be stabilized immediately following their construction. As an alternate, rock check dams may be provided at their outlets and/or the terminal downstream end of disturbance untif ground cover is implemented. 3. Stockpile and/or waste areas must be maintained within the limits of the areas protected b the proposed measures and otherwise temporarily seeded if to be left stockpiled over 15 calendar dyays. 4. Construction shall be planned so that grading operations can begin and end as quickly as possible. 5. Silt Fences shall also be installed prior to or as a first step in construction. 6. The Contractor shall be responsible for the installation and maintenance of all erosion and sediment control practices. Vegetative Ground Cover Immediately following grading, all areas shall receive either permanent or temporary seeding, as applicable, as follows: Feb -May June -Sept Oct -Jan Permanent Seed: K-31 Fescue K-31 Fescue K-31 Fescue ® 5#/1000 SF ® 5#/1000 SF ® 5#/1000 SF Temporary Seed: Rye Grain German Millet Ryye Grain ® 50#/Ac ® 40#/Ac 50#/Ar Fertilizer: 10-10-10 ® 25#/1000 SF Mulch: Straw ® 90#/1000 SF Lime: 100#/1000 SF Tack: 200 gallons/Ac on all '-nulching Maintenance 1. Reseed and mulch bare spots larger than 9 square feet (limited to 5% maximum of site area.) 2. Maintain all seeded areas until uniform stand is acceptable. 3. If growth is not established by final project inspection, continue specified attention until the stand is acceptable. 4. Correct and repair all undue settling and erosion within 1 year after final inspection. 5. Remove from the site, all erosion control structures after complete stabilization at end of construction period. 6. Remove silt from sediment pits and from behind check dams when silt is within half depth of the pit or spillway. Dispose of in an area where silt cannot re-enter pit / trap. Calculations The practice utilized for the proposed site did require formal calculations. Calculations have been provided. OWNER REDCO Properties, LLC 335 N. Queen Street Kinston, NC 28502 TEMP. STONE DITCH CHECK OF PAVEMENT 1' THICK NCDOT #5 OR #57 WASHED STONE FLOW 1 ( F �v() STRUCTURAL STONE/ CLASS 'B' BACK SLOPE ISOMETRIC VIEW BASE OF DITCH SEDIMENT F-12" MIN. 4'-6" OPTIONAL - TYPE 'B' - 12" THICK SEDIMENT SILT BASIN CONTROL STONE CROSS SECTION ELEVATION VIEW TRAPEZOIDAL DITCH CONSTRUCTION SPECIFICATIONS 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLANS ON A FILTER FABRIC FOUNDATION. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES. BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 3. EXTEND STONE AT LEAST 1.5 FT. BEYOND THE DITCH BANKS TO KEEP OVERFLOW WATER FROM UNDERCUTTING THE DAM AS IT RE-ENTERS THE CHANNEL. 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM. 5. PROTECT THE CHANNEL DOWNSTREAM FROM THE LOWEST CHECK DAM, CONSIDERING THAT WATER WILL FLOW OVER AND AROUND THE DAM (PRACTICE 6.41, OUTLET STABILIZATION STRUCTURE). 6. MAKE SURETHAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM IS STABLE. 7. ENSURE THAT CHANNEL APPURTENANCES, SUCH AS CU_VERT ENTRANCES BELOW CHECK DAMS, ARE NOT SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED STONES. (REFERENCE: EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, 6.83) CROSS SECTION VEE DITCH ROCK CHECK DAM SCALE: N.T.S. --WOOD OR METAL POST REINFORCED CONCRETE SILT FENCE PIPE SILT FENCE MIRAFI 100A OR TREVIRA 51115 TEMPORARY PIPE 4 INLET PROTECTION D-04 J-4 kl A. I IMAI ^n^11A1r) 8' MAX. WITH WIRE (6' MAX. WITHOUT WIRE) MIDDLE AND VERTICAL WIRES I SHALL BE 12 1/2 GAUGE MIN. WIRE) ILI FILTER 11i>tl3� SCALE: N.T.S. CONNECT WIRE TO POST WITH PLASTIC OR WIRE TIES FILTER FABRIC�� COMPACTED FILL 18-24" 8', I TOP AND BOTTOM STRAND SHALL BE 10 GAUGE MIN. L "i I TEFL POST- LJ EXTENSION OF FABRIC AND WIRE INTO TRENCH 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A EXTRA STRENGTH SYNTHETIC FILTER FABRICS. MAXIMUM OF 10' APART. SUPPORT POSTS SHOULD BE DRIVEN 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT SECURELY IN TO THE GROUND TO A MINIMUM OF 24". EXCEED 18 ABOVE THE GROUND SURFACE. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 POST SPACING DOES NOT 3. INSTALL THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE REQUIRE WIRE MESH SUPPORT FENCE. STAPLE OR WIRE THE FILTER LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE FABRIC DIRECTLY TO THE POSTS. NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A 7. EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 8" DEEP ALONG SUPPORT POST WITH OVERLAP TO THE NEXT POST. THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH 8. BACKFILL THE TRENCH WITH COMPACTED SOIL OR GRAVEL PLACED FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING OVER THE FILTER FABRIC. HEAVY DUTY WIRE STAPLES AT LEAST 1" LONG, OR TIE WIRES. 9. DO NOT ATTACH THE FILTER FABRIC TO EXISTING TREES. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. 10. LOCATION OF TEMPORARY SEDIMENT FENCE SHOWN ON THE PLANS IS NOT EXACT. CONTRACTOR SHALL FIELD LOCATE TEMP. SEDIMENT FENCE AS CLOSE TO THE DOWNSLOPE EDGE OF THE LIMITS OF CLEARING & Erosion Control Maintenance Plan All erosion and sedimentation control measures shall Block and Gravel Inlet Protection Inspect the barrier after each rain, remove sediment be inspected week) and after each runoff- -producing P Y P g as •iecessary to provide adequate storage volume rainfall event. Structures that shall be inspected include for subsequent rains. Upon stabilization of drainage but are not limited to: area. remove all materials and any unstable Silt Fence and Fabric Inlet Protection soil, either salvage or dispose of properly. Bring disturbed Any fabric which collapses, tears, decomposes, or becomes ineffective disturbed area to proper grade, then smooth and compact shall be replaced immediately. Sediment deposits shall be removed it. Stabilize all bare areas around the inlet. when sediment behind the fence reaches 6". Temporary Gravel Construction Entrance/Exit Seeding, Fertilizing, and Mulching Maintain the gravel pad in a condition to prevent mud Seeded areas shall be inspected for failure and necessary repairs or sediment from leaving the construction site. This may and re -seeding shall be made within the same season. require periodic topdressing with 2-inch stone. After a rainfall, immediately remove all objectionable materials spilled, washed, or tracked onto roadways. Erosion Control Notes: 1. Obtain erosion control plan approval prior to beginning land disturbance. Retain a copy of the approved erosion control plan and permit on site. Call NCDENR @ 252-946-6481 to notify the State Inspector of a start date prior to land disturbance. 2. Clear the area needed to construct the proposed construction entrance. 3. Construct the construction entrance as shown on the plans. Maintain the construction entrance daily to ensure that mud and silt will not be tracked onto the paved surface. If mud is tracked onto the road surface, it is to be removed immediately. 4. Construction entrance location may not vary without prior approval from Engineer and NCDENR. 5. Clear the area needed to construct the perimeter erosion control measures including silt fence and rock check dams. Rock check dams downstream of level spreaders, pipes and ditches shall remain in -place until permanent measures are stabilized. 6. Construct the silt fence. 7. Begin clearing, grubbing, and topsoil stripping for roadway rights -of -way. 8. Rough grade all roadways and parking lots. 9. Construct sanitary sewer system throughout project. 10. Construct the storm sewer system throughout the project. Install inlet protection devices. 11. Construct curb and gutter and CABC on roadway and parking lot. 12. Seed, straw and tack areas behind the curb and gutter that are graded to their final disposition. 13. Upon completion of the project, remove silt fence and rock check dams. 14. Seed, straw and tack any remaining exposed areas. Maintenance Notes: 1. Do not let any area remained exposed for more than 15 calendar days without applying temporary seeding. 2. Maintain all erosion control measures daily and reseed disturbed areas as needed. 3. Inspect all erosion control measures weekly and after each rainfall event. Repair as needed. 4. At the end of each day's storm drainage operation, construct a temporary pipe inlet protection device until the next day's operation continues. EROSION CONTROL MAINTENANCE PLAN SCALE: N.T.S. ULNLKAL NUItS: i.CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING W/2 INCH STONE. CONSTRUCTION ENTRANCE SCALE: N.T.S. CONSTRUCTION SPECIFICATIONS GRUBBING AS SPACE ALLOWS. 5 TEMPORARY SEDIMENT FENCE (SILT FENCE D-04 SCALE: N.T.S. DEWATER 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS _ - A SIDE ON THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE �- FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE °���� BOTTOM ROW OF THE BLOCK AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID 8, o WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE ° 0 o 4 LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2x4 0o a WOOD STUDS THROUGH BLOCK OPENINGS. CAREFULLY FIT 8000 HARDWARE CLOTH OR COMPARABLE yo�n 2. WIRE MESH WITH 1/2-INCH OPENING OVER ALL BLOCK J obo PM OPENING TO HOLD GRAVEL IN PLACE. 3. USE WASHED STONE PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. 4. INSTALL 1/4 IN. WIRE MESH HARDWARE CLOTH, AND METAL POSTS THAT ARE 5 FT. TALL. PLACE THE WIRE MESH A TEMPORARY SEDIMENT MINIMUM OF 3 FT. HIGH, AND THE STONE A MINIMUM OF 1 POOL FT. HIGH. 5. BEFORE COMMENCING CLEARING & GRUBBING OPERATIONS, THE CONTRACTOR SHALL FIELD LOCATE ALL EX. INLETS WITHIN THE OPERATIONS AREA AND INSTALL INLET PROTECTION. 1'MIN. (REFERENCE: EROSION AND SEDIMENT CONTROL PLANNING AND 2'MAX. .... DESIGN MANUAL, 6.52) 111- SEDIMENT BLOCK AND GRAVEL INLET PROTECTION SCALE: N.T.S. NOTE 4 NCRETE BLOCK 2:1 SLOPE, WASHED STONE FILTER WIRE SCREEN �N CARO�i� 026970 ° Vi 001 F,yGINEEf; �%•` 11/17/09 �0 N V N /'1 WSJ z V =XO Z a�am I --I w aM W ZU � z w �w W N J Z oQ z o No� Z �o NNE W N.� l U W�J � z O O a lid 0 o o � N Ul m U J O Z = N = � W W � ~ J ncn � D=04