Loading...
HomeMy WebLinkAboutSW7070408_COMPLIANCE_20100708STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW_ DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE I COMPLIANCE EVALUATION INSPECTION DOC DATEIc�� YYYYMMDD Bevaly Eaves Perdue, Governor Dee Freeman, Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Wata Quality July 08, 2010 Douglas E. Anderson Boddie Noell Enterprises Inc. 1021 Noel[ Lane Rocky Mount, NC 27804 SUBJECT: June 04, 2010 Compliance Evaluation Inspection Hardee's of Bridgeton Permit No: SW707048 Craven County Dear Mr. Anderson: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 04, 2010. Jeffery A Manning of the Washington Regional Office conducted the Compliance Evaluation Inspection. The facility was found to be in Compliance with permit SW707048. However, to avoid further actions by this office you must submit a signed Engineer's Certification (a copy is enclosed) as well as maintenance records for the stormwater BMPs at this facility within thirty (30) days of receipt of this report. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 252-948-3966. Sincerely, YJe#eA./ Manning Environmental Specialist Attachments cc: ,Central Files WaRo Files fan NCDENR 943 Washington Square Mall Washington, NC 27889 (252) 946-6481 Customer Service 1 800 623-7748 State Stormwater Inspection Report General Project Name: Hardee's of Bridgeton Permit No: SW7070408 Expiration Date: Contact Person: Douglas E. Anderson Phone Number: (252) 937-2800 Inspection Type: Compliance Evaluation Inspection Date: 04/12/2010 Time In: 09:30am Time Out: 10:30am Current Weather: Recent Rain (Date)? Rain — in Location Facility Address / Location: U.S. 17 City: Bridgeton I zip: County: Craven Lat: 0 1"N Long: - 0 1"W Permit Information Rule Subject to (circle one): 1988 Coastal Rule 1995 Coastal Rule 2008 Coastal Rule Session Law 2006-246 Goose Creek High Quality Waters Outstanding Resource Waters Density (circle one), High (HD) Low (LD) Stormwater Best Management Practices (BMPs) (insert number of each): Wet Ponds X Infiltration Basins _Infiltration Trenches LD Swales _Stormwater Wetlands _Dry Ponds Bioretention _Permeable Pavement Sand filters (circle one) Open Closed Cistern _Level Spreader/Filter Strip Other (spec): Files Reviaw Yes No N/A N/E I. Is the permit active? X 2. Signed Engineer's Certification on file? X 3. Signed Operation and Maintenance agreement on file? X 4. Recorded Deed Restrictions on file? X Rita Visif- Ridif llnnn Area MIMI Yes No NIA N/E 5. BUA is constructed and consistent with the permit requirements? X 6. BUA (aspermitted) is graded such that the runoff drains to the system? (high density only) X 7. Drainage area is consistent withpermit? i.e. no un ermitted drainage to the SW BMPs X 8. Drainage area is stabilized? (to reduce risk of sedimentation to the SW BMPs) X Site Visit: Stormwater BMPs Yes No NIA N/E 9. Stormwater BMPs are located per the approvedplans? X 10. Stormwater BMPs have dimensions (e . length, width, area) matching the approvedplans? X 11. Stormwater BMPs are constructed per the approvedplans? X Site Visit: Oneration and Maintenance Yes No N/A N/E 12. Access points to the site are clear and well maintained? X 13. Trash has been removed as needed? X 14. Excessive landscape debris (grass clippings, leaves, etc) is controlled? X 15. Stormwater BMPs being operated and maintained as per the permit requirements? X 16. Inspection and Maintenance records are available for inspection? (high density only, 1995 — present only) X Yes issues as noted durine the State Stormwater Inspection Report, Version 3.0_3-09 Pagel of2 State Stormwater Inspection Report The facility was found to be in Compliance with permit SW7070408. However, to avoid further actions by this office you must submit a signed Engineer's Certification (a copy is enclosed) as well as maintenance records within thirty (30) days of receipt of this report. of the See Inserts Compliance Status X Compliant Non -Compliant Letter Sent (circle one): Yes No Letter type: CEI NOV NOVRE Other Date Sent: July 08. 2010 Reference Number: Inspector Name and Signature: Date: July 08, 2010 State Stormwater Inspection Report, Version 3.0 3-09 Page 2 of 2 INFILTRATION BASIN O & M Inspection Report I' Inlets and Phetreatrrient . I . ,` ur' _ _}." " _- , ' >. "`:`,: I 1. Drainage area is managed to reduce the sediment load to the basin: 2. Bypass structure / Vegetated filter is free of erosion and obstructions: ® ❑ ❑ ❑ 3. Inlet device is free of erosion, damage or clogs: ® ❑ ❑ ❑ 4. Pretreatment area free of excessive sediment: ® ❑ ❑ ❑ 5. Pretreatment area is free of erosion: ® ❑ ❑ ❑ 6. Rip rap (if used) is in correctly placed: ® ❑ ❑ ❑ 7. Perimeter of the infiltration basin is free of bare soil or erosion: ® ❑ ❑ ❑ 8. Vegetation around the basin is maintained at —6 inches height: ® ❑ ❑ ❑ 9. Slopes and bottom are free of erosion and woody vegetation (trees or shrubs): ® ❑ ❑ ❑ 'Main Triatih4brit *6 4 1 10. Main treatment area is free of weeds: ® ❑ ❑ ❑ 11. Vegetation in the basin is maintained at —6 inches height: ® ❑ ❑ ❑ 12. Main treatment area is free of excessive sediment: ® ❑ ❑ ❑ 13. Main treatment surface area is free of clogs: ® ❑ ❑ ❑ 14. Basin is drained and it has been more than 5 days since last rain: ❑ ❑ ❑ J. o6uet Device 15. Outlet device is free of erosion, clogs or damage: ® ❑ ❑ ❑ 16. Orifice size matches approved plans: ❑ ❑ ❑ 17. Relative elevations match approved plans: ® ❑ ❑ ❑ 18. Outlet device draining properly — (free of standing water, cattails, etc.): ® ❑ ❑ ❑ V3.3_09 :� f. 9 ol�,- INFILTRATION SITE VISIT REQUEST Name of the Project: Bridgeton Bargain Bin, Bridgeton, NC Location (attach a clear vicinity map): 120 C St., Bridgeton, NC Street address, SR number, community, etc. Directions from the nearest major intersection: site is located between US Hwy 17, D Street (Old US 17), and C Street in Bridgeton. Owner/Applicant Name: Applicant: Boddie Noell Enterprises Inc. Consultant Name: Commercial Site Design, PLLC Consultant Contact Information: Daniel Brown, Proiect Engineer, phone: 919-848-6121, fax: 919-848-3741, email: brown csitedesign.com Phone, tax, email, etc. #1 #2 #3 #4 #5 #6 #7 #8 Existing ground elev. @basin/trench= 7.5 7.5 10.0 SHWT elev.= SHWT plus 2' (max. bottom elev.)= Date/Time of Soils Investigation Summary/Comments: All proposed infiltration areas and existing, active utility lines located within the proposed basin/trench must be marked and flagged. If these areas are not flagged, the Soils Scientist reserves the right to decline to do the investigation. If the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, equipment capable of breaking through the impervious layer must be provided. The soils investigation does not take the place of a soils report prepared by an appropriate professional. The Soils Scientist will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 21-1.1000, and assumes no liability should the system fail.