Loading...
HomeMy WebLinkAboutSW7070226_APPROVED PLANS_20070301STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW �D �DiD DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD I N VEYERHAUSER 00 M.9.1A P.151 0.8.110 P.403 CA DITCH wlLlos PROPERTIES D.B.362 P.306 ASPHALT LEGEND: = LIGHT DUTY ASPHALT = HEAVY DUTY ASPHALT I - " .,., A 6" CONCRETE I, JOHN L. PIERCE, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED REFERENCES SHOWN HEREON); THAT THE BOUNDARIES NOT, W E CLEARLY INDICATED; THAT THE RAT1l"i y. AS CALCULATED IS 1:10,000+; roJCIUAl CIPMATliOc uccutl lRC- . 20Qi "u Slf y' TO ORANTSBORO N.C. HWY. 66 z r VICINITY MAP - NOT TO SCALE EIS - EXISTING IRON STAKE EIP - EXISTING IRON PIPE ECM EXISTING CONCRETE MONUMENT TB = TELEPHONE BOX SIS - SET IRON STAKE SCM = SET CONCRETE MONUMENT SPK = SET P.K. NAIL RCP = REINFORCED CONCRETE PIPE WM = WATER METER WV WATER VALVE MH = MANHOLE SP = SERVICE POLE PP POWER POLE SL SECURITY LIGHT CA CENTERLINE R/W RIGHT-OF-WAY N/F NOW OR FORMERLY FH = FIRE HYDRANT INV = INVERT GW = GUY WARE TP TRAFFIC LIGHT POLE -E- POWER LINE TRAFFIC DIRECTION ® = STOP SIGN DA:UE - DRAINAGE & UTILITY ESMT. 11 - HANDICAP RAMP G.V. - GATE VALVE - HANDICAP SPACE APPARENT APPARENT ��'�•��. — — — am — — — — p — — — — — BENT E _ _ N W' W$6' W 160.00' _ CAS '% — - -. N 6694'65 WT220.00' & RiC C� CA DITCH PREENTER W GRAVEL DRIVE 146, Z 30' 20'-4 TELEPHONE LINES ^ DRIVE B DRIVE A SPK r TURN LANE = TAPER APPROVED 5� — IV.I.i. fllVrlYY/1I � ��VV /11 °,)FTr =}F� NTE0 AOSION"ai. BENEATH HWY 1234.33'Ta C OF c� ; MFN!O 1 c VV i;Qtf 1 '$ION p b S'�ON Of WATEk Ol!AUTY NCSR 1241 - ---- 07 �e ..Wr .vcter Perot Nv�� �O%G Z z6 E E E CONTACT PERSONS: 1- WATER: PAMLICO COUNTY, LEE TILLMAN. 252-745-5453 2- POWER: PROGRESS ENERGY: BRUCE NOBLE, 252-636-1328 3- TELEPHONE: EMBARO: 1-800-842-5400 4- NORTH CAROLINA DEPT. OF TRANSPORTATION: Aaron Everett , 252-514-4716 5- SEWER: BAY RIVER SEWER CO., JIM KRAUSE, 252-745-4812 REF: PORTION OF D.B. 312, P. 141 PORTION OF D.B. 382 P. 306 PORTION OF M.B. IA, P. 151 TRACT III, PLAT CAB A, SLIDE 99-2 N.C.G.S. MON. 'ALLIANCE' N-613,031.4043 E-2.656,006.341 HAD e3 DEVELOPER: E.J. POPE do SON, INC. P.O. BOX 649 MOUNT OLIVE NC 28365 PHONE 919-658-6566 N.C.G.S. MON. 'LIaIOR' N-514,706.7396 E-2.660,966.332 CF-M999673765 HAD 63 TRACT DATA WATER- PAMLICO COUNTY SEWER- BAY RIVER SEWER CO. NO ZONING TOTAL AREA 77,949.13 sq.ft. 1.79 acres 2.2 AC. DISTURBED 27 PARKING SPACE W/2 H/C SITEIUTIL/TY PLAN FEB z :'1 2007 OF HANDY MART#169 PREPARED FOR E.J. POPE & SON, INC. NO. 3 TOWNSHIP, PAMLICO COUNTY, INC PREPARED BY JOHN L. PIERCE & ASSOCIATES, P.A. 409 JOHNSON BLVD. JACKSONVILLE, INC 28540 PHONE: 910-346-9800 DATE: 2-14-07 SCALE: 1 "= 30' F.B. 750 , PG. 47+ JOB #268605 FILE NAME: PAMLIICO.ASC REV:2-20-07 GRAPHIC SCALE ( IN FELPT ) 1 inch - 30 fL SHEET 1 OF 4 CONSTRUCTION NOTES: 1. LOCATION OF EXISTING WATER AND SEWER MAINS TO BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. WATER AND SEWER SERVICES PROVIDED BY THE SITE CONTRACTOR. 3. ALL INSTALLATION OF WATER AND SEWER MATERIALS AND PRACTICES SHALL MEET NTH PAMLICO COUNTY SPECIFICATIONS. 4. CONTRACTOR TO PROVIDE POSITIVE GRADES FROM BUILDING TO WALKS AND USE FILL AS REQUIRED. 5. THIS SITE IS SUBJECT TO SELECT CLEARING AND NO CLEARING WALL BE DONE WITHOUT THE OWNER OR HIS REPRESENTATIVE'S APPROVAL 6. SITE SUBGRADING: TOPSOIL AND UNSUITABLE MATERIAL REMOVAL AND DISPOSAL ARE REQUIRED TO BE DONE PRIOR TO PLACING THE SELECT BACKFILL MATERIALS. 7. ALL STORM WATER HANDLING FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH N.C.D.N.R. STANDARDS AND SPECIFICATIONS. 8. SITE ACCESS: ACCESS SHALL BE LIMITED TO THREE DRIVEWAYS AS SHOWN ON THIS PLAN AND SHALL HAVE A CONSTRUCTION ENTRANCES AS SHOWN ON THIS PLAN. 9. ALL PAVEMENT AND STONE BASE SHALL BE INSTALLED AS PER STANDARDS AND SPECIFICATIONS AS SHOWN IN DETAILS. 10. SUBJECT TO CONFIRMATION OF WATER METER SIZE ADEQUACY. 11. MAXIMUM BUILDING HEIGHT IS LESS THAN 60' 12. AS THIS SITE IS DEVELOPED, ALL ENVIRONMENTAL REQUIREMENTS SHALL BE MET. 13. ALL POWER POLES, POWER LINES, ETC. ARE TO BE RELOCATED TO ACCOMMODATE PROPOSED CONSTRUCTION. 14. CONTRACTOR TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. 15. DEVELOPER TO INSTALL STOP SIGNS AS SHOWN. 16. HANDICAP PARKING SIGNS ARE TO BE ABOVE GROUND AND BE EITHER R-7 OR 12-8 SIGN. 17. ALL DRAINAGE SHALL BE SHEET DRAINAGE OR WITH SURFACE DRAINAGE (AS SHOWN). 18. ALL CLEAN -OUTS TO BE IN VALVE BOXES IN PAVED AREAS. 19. THIS PROPERTY IS NOT LOCATED IN A FLOOD PLAIN ACCORDING TO F.E.M.A. MAP 3720656000J ANY RESIDENTIAL LOTS OR ROADWAY TRAFFIC. 20. ALL EXTERIOR LIGHTS WALL BE LOCATED AND POSITIONED SO NOT TO ADVERSELY AFFECT DATED JULY 2, 2004. 21. EXISTING DROP INLETS AFFECTED BY CONSTRUCTION TO BE PROTECTED PER DETAIL 22. PROPOSED ROOF TO BE PIPED INTO PROPOSED DRAINAGE NETWORK. 23. ALL DISTURBED AREAS WALL BE STABILIZED WITHIN 15 WORKING DAYS OF THE COMPLETION OF ANY PHASE OF GRADING. 24. ALL CURB AND GUTTER TO BE STANDARD TYPE 24•CURB k GUTTER (UNLESS OTHERWISE SHOWN). 25. A WET TAP BY A PROPERLY LICENSED PUBLIC UTILITIES CONTRACTOR WALL BE REQUIRED FOR THE SERVICE INSTALLATION. ASPHALT LEGEND: = LIGHT DUTY ASPHALT -HEAVY DUTY ASPHALT 6" CONCRETE WLKES PROPERTIES, WIC. 0.8.352 P.306 NO WETLANDS ONSITE 94V-9.79 �9.70 PR 20'NTAaE EASEMENT +13.30 �4 1 " I +12.30 +12.44 12.10 +12.13 N/F r TRACT II WILKES COMMERCIAL CENTER PLAT CAB. AV SLIDE 99-2 13.19 +13.12 +13.23 +13.20 CB TOP-14.1 INV-11.51 13. Y. 6'RIP-RAP N NICK W/9Eo-TE)M E ,�1N/F ERLAw'fENT AIELISER CO M.9.1A P.151 13.87 D.&110 P.403 CA 9.65 1325 63 --- 2-, 2 + 12 12.85 1�g 13.17 {a 12.79 \ (j ABANDONED NORFOLK-SOUTHERN RAILROAD - 100' R/W - } - DEEDED TO WILKES PROPERTIES, INC. IN D.B.382 P.306 I +13.1s O } s 14.46 4H, ,cj pj 1 {3• ' +13.45 i9 5 NDETENTION SF SF13.79 11+13.15 POND 1 41 +13.35 15 S.Y. 6•RIP-RAP Zw 12,moL W/GEO-TEXTILE MV-10.45 UNDERLAYMENT 13.07 FORMER R/W +13.25 3� FENCEOR NNYL 't COATED OW/ Is- G^ J.o \ou' \ +12.85 GRADING CONTRACTOR RESPONSIBLE FOR PER NIO k ESTABLISHING STANDARD GROUND COVER PER SEEDING & R STANDARDS c �n � +13.55 IV-10.85 12 2 +12.88 -" +13.35 � �m ar '.' +13.18 / 169 14. 14. I C-STORE SEOL-15 / FF 4 +13.19 x9 / HTr 14.5 h �1 <�I t 2• f1 < nE3 • a •, 14. a, <� `,a -P13.49r-y 4 , 14.2 ,� ` ` < 2-RCVS OF 6'PVC •< 13.9 ` FOR CANQPYf GRANTS .f of < ,•, r 4 f, FIT 4 14. , k. 'WD 'FWIA tA2 14.5"7 t6 , 14.3rj 14.2 `� 1 `, `f, a aaT � < a �• +13.45 ETr/xp. -ems b 13.37 +13.05 O�! 14. +13.55 N. N CB TOP-14.0 NV-11.02 }13.95 13.44 d O +13.05 14. DBL +13.35 +13.30 +13.55 ce 7 TOP-14.0 INV-11.29 +13.35 -1 J 14, 2 DBL 13.14 h O +13.55 I, JOHN L PIERCE, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED REFERENCES SHOWN HEREON); THAT THE BOUNDARIES NOT l� D ARE CLEARLY INDICATED; THAT THE RAT(0 �N AS CALCULATED IS 1:10,000+; ORIGIN6SIGNATURE, LI ERE VA :'c 'VA THIS 4� DAY OF kL JOHN L. PIERC P.L.S. L-2596.IANVI L. T-f2wJ96 Ord jF�<GEND:GEND: EIS = EXISTING IRON STAKE EIP EXISTING IRON PIPE ECM = EXISTING CONCRETE MONUMENT TB = TELEPHONE BOX SIS = SET IRON STAKE SCM SET CONCRETE MONUMENT SPK SET P.K. NAIL RCP = REINFORCED CONCRETE PIPE WM = WATER METER WV = WATER VALVE MH MANHOLE SP PP = SERVICE POLE POWER POLE SL = SECURITY LIGHT CA CENTERLINE = RIGHT-OF-WAY N/W = NOW OR FORMERLY FH FIRE HYDRANT INV = INVERT GW = GUY WIRE TP TRAFFIC LIGHT POLE -E- = POWER LINE = TRAFFIC DIRECTION = STOP SIGN D&UE - DRAINAGE do UTILITY ESMT. A- HANDICAP RAMP G.V. - GATE VALVE = HANDICAP SPACE = DOUBLE CONC. BLOCK FILTER AlYNCH, 46 - ROCK CHECK DAM DANIEL 111 D.8.446 P.793 GRADING LIMITS = RIP -RAP APRON -SF- - SILT FENCE + 18.20- SPOT ELEVATION PROPOSED ELEVATION = DIRECTION OF FLOW INV. - INVERT . C ""'•.. CB = CATCH BASIN DI DROP INLET "�o VA ®= RIP -RAP INLET PROTECTION L �ZU ce .,3�. i1 ce a a a TOP- N +13.55 14.1 TOP-1x9 :, / 14.5 INV-11.9 <a �< ' •a a • MV-11. 1 T tiECM 14.0 Xii - yam{} * N- 514,792.052 GAS �T 12.80 TR NE 1 l ..� 140 11.7 APPARENT E- 2680729.688 13.33 14. 13.32 13.03 142 ;,�� �t 14. 14.iT 12.68 .B �'i S 1x .-. r. 4. ECM 13.75 13.70 CAS LINE N 1 46 1234 13.44 NV-12.a 1&0 ENTRANCE 0-03 13,INV-11. 4 LF 18'RCP 0O.51G _ 11.84 _�-12-- ,At.6d'�12 15'RCP OOS%�: �5 - M 10.51 11.59 CA DITCH 55 LF -- •+ .-. - 12.27 4 11 = +10.49 t- + +. r• -�-- _- 12 L7`l3 � , 12 +12.77 12- --lT'T 1.3� _- 11.73 -12- 12' 12.47 IN S ^', 12 13.1 + 133 1xS �i 1297 13 +2.63 .1� - 1x3 •� ere 1S155""w..,*r+'v +r� r-*y7 •+, e� �s...*.s^++ .I. 1+„39p�e`-sm"., ^ +m wnv m. w asnl+w*"w+s !era t51i3 ww*a+wr.r*a ..me! NO R*!*�t*� mTp!� � .�Zr4399 t 3fi - Nee ` TELEPHONE -14� ` +13.80 +13.86 +13.92 -14.00 +14_11 14.20 SPK 4-5TE.PTH +14.26 14.33 - f11 Vfl YY /'1 I� ��VV/YY 1234.3ST000F -14 -_--�-�<- 13.17 13.21 13.40 13.40 NCSR 1241 I 1396 13 23 13�- 13.23 ' 13.45 13.60 13.58 13.69 13.76 \ 84 12-5� T 13. 12.95 .�. / LOCATIONAPPROX •13.46 >_ WV FORCED SYSTEM APPROX. LOCATION 6'SEWFR FORCE SEVER VALVE 13.90 MANHOLE 12.48 < 12.84$ INVERT NOT G'WATERLINE (PER MAIN, *35'DEEPDAY RIVER 14.20 13.76 14 St ACCESSIBLE PAMLICO COUNT1� � 00.) 3'-4`0EPTH I' 14.21 E E E -� � E E E E -� �C - "-E -�E E E E E---k--�- i�-�_ bE.�e6- E- 12.27 � PP 2.73 CONTACT PERSONS: S 1- WATER: PAMLICO COUNTY, LEE TILLMAN, 252-745-5453 N.C.C.S, NON. 'AWANCE' 2- POWER: PROGRESS ENERGY: BRUCE NOBLE, 252-636-1328 N-515,031.4043 E-2,656,006.341 3- TELEPHONE: EMBARQ: 1-800-842-5400 HAD 83 4- NORTH CAROLINA DEPT. OF TRANSPORTATION: Aaron Everett , 252-514-4716 5- SEWER: BAY RIVER SEWER CO., JIM KRAUSE, 252-745-4812 DEVELOPER: REF: PORTION OF D.B. 312. P. 141 E.J. POPE & SON, INC. P.O. BOX 649 PORTION OF D.B. 382 P. 306 MOUNT OLIVE, NC 28365 PORTION OF M.B. iA, P. 151 TRACT III, PLAT CAB A, SLIDE 99-2 PHONE 919- 8-6566 Stormwater Design By. CRYSTAL COAST ENGINEERING, P.A. 3817-6 PREBDOM RAY - HUBERT, N.C. - 28539 Phone (910) 325-0006 Fax (910) $25-0060 www.crywWcoastengineering.com David L Newsom, PE ♦ 13.82 13.97 •► 13.86 13.59 13.7 ' 3.97 GRAVEL DRIVE / �•RlIe1eW \ 4.02 .9eae '-41R11^-'�- V+e !i! AR�AlIIplR�la1 1u11 1P� Rm*Pw,eneAlFlA 14.44 N.C.G.S. MON. '9.I000r N-514,708.7396 E-Z680,968.552 CF-0.999873785 NAD 83 TRACT DATA: E� E WATER- PAMLICO COUNTY SEWER- BAY RIVER SEWER CO. NO ZONING TOTAL AREA 77,949.13 sq.ft. 1.79 acres 2.2 AC. DISTURBED 27 PARKING SPACE W/2 H/C E - GENERAL GRADING DRAINAGE PLAN EROSION CONTROL PLAN STORMWATER PLAN OF HANDY MART#169 PREPARED FOR E.J. POPE & SON, INC. NO. 3 TOWNSHIP, PAMLICO COUNTY, NC PREPARED BY JOHN L. PIERCE & ASSOCIATES, P.A. 409 JOHNSON BLVD. JACKSONVILLE, NC 28540 PHONE: 910-346-9800 DATE: 2-14-07 SCALE: 1"= 30, F.B.750 , PG. 47+ JOB #268605 FILE NAME: PAMLIICO.ASC REV:2-20-07 GRAPHIC SCALE 30 0 15 30 60 ( IN FEET( FEET )) 1 inch - 80 ft. SHEET 2 OF 4 6' I F-6' 840.14 v v m My 1 >C~A• O r-C)-n-4M 1m•1Z--1SD =-n >m Z�=00 A'=O�Z D D D < ca rcal z 0 00 Mp z : M H7 = M H Z N r i v m-1 4 v D O Co m v v 4 h, oZ3E ;v" A Z 17 Z -n v -4 00m o y 1/2' RAD, N •�3' RAD. I �1/8' RAD, O IE 2'-0' N.C,D,O,T, STANDARD 24' CONCRETE CURB & GUTTER SCALE, L' 1'-0' 8" 1'-8- 1/2' RAD. �3RAD. f 1/8' RAD. p r, 1 2- N SPILL TYPE 24" CONCRETE CURB do GUTTER NOT TO SCALE I Y PLAN WITH ORATE 8 FRAME REMOVED SECTION X-X ^." WEEP HOLES CENTIPEDE SOD TO BE INSTALLED TO TOP OF SLOPE OR FAR ENOUGH TO STABILIZE SLOPE (WHICHEVER REQUIRED DITCH DETAIL NO SCALE 3" SF 9.5 B 27 0611950 10 ° 00 99 400 9 °°° $ 6' ABC 499900 190 00 0 00 0° O 0 ° O O 0° LIGHT -DUTY ASPHALT NOT TO SCALE 3" SF 9.5 B ,9 O 0 00 D99 00 0019 M ?O ° 10" ABC 00 p 0O 00 00 0 p 0 7049 00 p °00 000 19 Oy GENERAL NOTES: F } USE CLASS "B" CONCRETE THROUGHOUT. Q Q 2a PROVIDE ALL DROP INLETS OVER 3' S" IN DEPTH WITH STEPS 12" N cc U ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING $40.86. LL O • OPTIONAL CONSTRUCTION - MONOLITHIC FOUR 2" MIRY OR I4 BAR DOWELS AT J I„t O O W S Z 12" CENTERS AS DIRECTED BY THE ENGINEER. CC Z .. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. PS _ QTQ•I IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB Q AS SHOWN ON STD. NO. 840.00. F O W CONSTRUCT WITH PIPE CROWNS HATCHING. cc O O 1-4 INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. Z . ; INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 79M STONE IN A H M POROUS FABRIC GAS OR WRAP, AT EACH WEEP HOLE OR AS DI8ECTED BY THE ENGINEER. La Q CHAMFER ALL EXPOSED CORNERS 1". Q DRAWING NOT TO SCALE. UVINU(1NUlUbMIAL) P ELEVATION 840.16 FRAME LATE I 81jj B 0-7I I I (SEE NOTE) MAX. PIPE THIS SIDE SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BSA W�L HHTTR w t u C.M. R.C. 12" 3'•0" 2'-0" 2'-0' 0.222 0.222 0.592 0.015 0.026 15" 2 -3 0.648 0.023 0.036 is" 2'-8" 0.703 ' 0.033 0.049 24 9 -0' 0.814 1 0.059 0.085 30" 3'-0" 2'-0' 3'-6" 0.222 0.222 0.925 , 0.082 0.127 ----EROION SECTION G-G 21 31/4 n 1 11 21' SECTION H-H 11 N It It . 1tn '\ IT►H T-G o O G 0 o a ■M�■ MWMWW� HN L► H\ L4W 1'•41'Q" T I II 1 _ 11 1 -7% 1 7`% PLAN OF GRATING CAST IRON W4 BAR �E! L DOWEL q rrr F� PLAN OF FRAME CAST IRON 1„ it, irr i,1 3r-3:4" 2r-3�$n �N Oar 2r 4`n I2r 2rrr O O VA 24" -�� 24' O� 3r_1�" N N2r 1rr N N 31-6" SECTION E-E SECTION F-F 0 ~ U.W C9 J N Z MJ 3: a C3 I= 0 CC 0 CO c � W = H w W, _ � N O Z a O W 840.14 z O W My } Qa cc V O O CL S Z a-Q=00•1 F N FEU. OOyQ Z j L U QQ U) T- 0 caIt HO Q LL IC Q It 3 Z p ¢aGo Q W y Z U. U Co H 0 x J O co " Z 2 J M I- M Z d 3 W Q LU 0 co LL 840.161 1840. ; `•t, :•;.. ''.+', t1/2• MESH HARDWARE CLOTH •+" w��•••-• ;. M ,+E� �•\.•,..,N:•A• .«. �• •.1' •\•• �'\; ., .:\•ice : . A. .w 't L 8• X is" : �•;• DONGRE,E BLOB( 00000000000 ::.: tfN 0000aaooaoa .` y4. :...:. CATCH BASIN ' A ' • t' • \ • a WASHED STONE 1 • 'A •• • " ARDWARE CLOTHSTONE I d.. SEEDBED PREPARATION NOTES: 1. SURFACE WATER CONTROL MEASURES TO BE INSTALLED ACCORDING TO PLAN. 2• AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD NTH AVAILABLE 3. LOOSE ROCKS, ROOTS AND OTHER OBS'RUCTIONS SHALL BE REMOVED FROM THE SURFACE SO THAT THEY WALL NOT INTERFERE NTH THE ESTABLISHMENT AND MAINTENANCE OF VEGETATION. SURFACE FOR FINAL SEEDBED PREPARATION, AT FINISH GRADES SHOWN, SHALL BE REASONABLY SMOOTH AND UNIFORM. 4. IF NO SOIL TEST IS TAKEN, FERTILIZER AND LIME TO BE ACCORDING TO SEEDING SPECIFICATIONS ABOVE. IN ADDITION, PROVIDE 15 LBS/1000 S.F. OF SUPER PHOSPHATE. 5. IF SOIL TEST IS TAKEN, PROVIDE LIME AND FERTILIZER ACCORDING TO SOIL TEST REPORT. 6. LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING SEEDBED PREPARATION. MAINTENANCE PLAN 1-ALL EROSION AND SEDIMENT CONTROL PRACTICES WALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF - PRODUCING RAINFALL BUT IN NO CASE LESS MAN ONCE A WEEK. ANY NEEDED REPAIRS WALL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2-SEDIMENT WILL BE REMOVED FROM THE SEDIMENT TRAP AND BLOCK AND GRAVEL INLET PROTECTION DEVICE WHEN STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. GRAVEL WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS 3-SEDIMENT WALL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES ABOUT 0.5 FT DEEP AT THE FENCE. THE SEDIMENT FENCE WALL BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. 4-ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER. 5-AFTER CONSTRUCTION HAS BEEN COMPLETES THE OWNER WALL PERPETUALLY MAINTAIN ALL DEVICES THAT CONVEY STORMgATER AND ALL VEGETATIVE AREAS TO MINIMIZE THE EFFECTS OF EROSION. SEEDING SCHEDULEDNCLUDING POND SIDE ROPES) SPREAD 4' TOPSOIL OVER AREAS TO BE SEEDED M ESTABLISH UNIFORM GRADE PRIOR TO SEEDOM APPLY LAME AND FERIILOIR AND WORK INTO SEED BED, DISTRIBUTE SEED UNIFORMLY AND COVER LIGHTLY. APPLY CLEAN STRAW MULCH OVER SEEDED AREA AND ANCHOR SECURELY WITH STRAIGHT BLADE DISC IN FLAT AREAS AND WIN ASPHALT TALC WHERE SLOPES EXCEED 4% MATERIAL APPUCATKIN RATE LIME CRE 20% SUPERPHOSPHATE 200D P UNDS/ACRE FERTII.RER(10-10-io) 100p POUNDS/ACRE APRIL - JULY FESCUE, KY-31 ACRE BERMUDA (K UM) 0 POUNDS/ACRE JANUARY - MARCH BERtiIUDACRE A (UNHULLED) 20 POUNDS/ACRE RYE (GRAIN) 25 POUNDS/ACRE SEPTEMBER - NOVEMBER FESCUE, KY-31 50 POUNDS/ACRE MULCH 2 TONS/ACRE ASPHALT TALE 3HM GALLONS/ACRE NOTE OWNER MAY VARY SEEDING TO CONFORM TO LANDSCAPING REOUIRD MS. NOTE: RYE GRASS OR WEEPING LOVE GRASS SHALL NOT BE USED. AS NOTED R.C.P. 7.5' 13' 0 0 0 C)� O O O 7.7' O O � O O� CLASS A RIP -RAP 1' THICK W/ GEOTEXiiLE UNDERLAYMENT RIP -RAP APRON OUTLET PROTECTION (NOT TO SCALE) 12 ONO[ 4•IM• at rW SE M TJJE H= D ONTO PRMII = OUMME S ON METAL POSTS, of FASTENS) TO COM ON MOOD POSTS STAR M& 8 STAR= LLTEAVIILT REM ANT M■IN rmm OR EOWNINT TO MRE WFM METAL CUM RI WIFE AT I. OFF CENMR. MANMIM =D ff STOIIAR ,M. Rel • eMOM MEN TARS LEM M WAD= m AS OMECTED BY CONS ItYATION RAM NATI■N. MADE 111111011111MM1T�County @.�APPPMROXIMATELY 1Y OF FASMD R10 1110106 III��1 SOL AID TNB SACIOII. -CARRY e' aF W2E M10 TMgt METAL 091MA OR eW TREATED MOOD POSTS AT e OW CDMWR MAIIRIM. CM AR AM ROOD POSTS SHOULD TE X DEEP MRMIIL NOTES: 1-GRADING CONTRACTOR IS 100% RESPONSIBLE FOR ESTABLISHING GROUND COVER PER SPECS. 2-FENCE AROUND POND BY GRADING CONTRACTOR. B" FRA MAX New 2' 2' :4' ..dd ' a 4ad e A 4' r 2500/ tbMC. FOOTING CONSTRUCTION SEOUENCE 1. OBTAIN PLAN APPROVAL 2. INSTALL CONSTRUCTION ENTRANCE AND SILT FENCE, THEN INITIATE CLEARING. 3. CONSTRUCT POND AND INSTALL PIPES. 4. MAINTAIN STRUCTURES DURING CONSTRUCTION. 5. STABILIZE SLOPES & DITCHES AS THEY ARE BROUGHT TO GRADE. 6. PAVE DRIVE AND PARKING LOT 7. REMOVE TEMPORARY EROSION CONTROL MEASURES AFTER AREA HAS BEEN STABILIZED. PIPE ID + 2'4• RE -BAR 3' 7 1/2• 8' 12' O.C. EAC 8' D NC 1/4' EXPACOMNSION MATE 14 EXPANSION MATE e• H CONC 1/2 PIPE I.O. GROUTN I av'��FILL d s e e 4+'d F250 GOON C_ - NOTE: COVER TO BE PROVIDED WITH TWO (2) LIFTING HANDLES TYPICAL JUNCTION BOX NOT TO SCALE EXISTING ROAD R/W si V R/W 50' MIN. LENGTH CONSTRUCTION ENTRANCE PROFILE (SEE NOTE) PLAN VIEW Construction Specifications 1. Stone size - Use MSHA size No. 2 (2-1/2" to 1") or AASHTO designation M43, size No. 2 ( 2-1/2" to 1-1/2"). Use crushed stone. 2. Length - As effective, but not less than 50 feet. 3. Thickness - Not less than six (6) Inches. 4. Width - Not lees than full width of all points of Ingress or egress. Minimum of 12'. 5. Washing - When necessary, wheels shall be cleaned to remove sediment prior to entrance onto public right-of- way. When washing is required, it shall be done on an area stabilized with crushed stone which drains Into an approved sediment trap or sediment basin. All sediment shall be prevented from entering any storm drain, ditch, or watercourse through use of sandbags, gravel, boards or other approved methods. 6. Maintenance - The entrance shall be maintained in a condition which will prevent tracking or flowing of sediment onto public rights -of -way. This may require periodic top dressing with additional stone as conditions demand and repair and/or cleonout of any measures used to trap sediment. All sediment, spilled, dropped. washed or tracked onto public rights -of -way must be removed Immediately. STABILIZED CONSTRUCTION ENTRAN NOT TO SCALE N CA �pP�•'Ess � QP . - AL TYPICAL CURB INLET 1 148 CH BIN 2000 NOTTO SCALE O •'F. ,?INEe'S0; K. N Stormwater Design By. CRYSTAL COAST ENGINEERING} P.A. 3817-3 FR136DOM WAY - HUBMT. N.C. - 28539 Phone (910) 325-0006 Fax (910) 325-0060 wwW.olyWtalcoastanglxtearing.com David L Newsom, PE DETAIL SHEET OF HANDY MART#169 PREPARED FOR E.J. POPE & SON, INC. NO. 3 TOWNSHIP, PAMLICO COUNTY, NC PPARBY JOHN L. PIERCERS&EASSOCIATES, P.A. 409 JOHNSON BLVD. JACKSONVILLE, NC 28540 PHONE: 910-346-9800 DATE: 2-14-07 SCALE: N/A F.B.750 , PG. 47+ REV:2-20-07 JOB #268605 FILE NAME: PAMLIICO.ASC SHEET 3 OF 4 EX. DITCH ANTI-: COLLAF N/F WEYERHAEUSER CO M.B.1A P.151 D.BA10 P.403 Treatment Pond - Plan Scale: 1" = 20' SEEDBED PREPARATION NOTES, 1. SURFACE WATER CONTROL MEASURES TO BE INSTALLED ACCORDING TO PLAN. 2. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH AVAILABLE TOPSOIL 3' DEEP. TOTAL SEEDBED PREPARATION DEPTH SHALL BE 4'-6' DEEP. 3. LOOSE ROCKS, ROOTS AND OTHER OBSTRUCTIONS SHALL BE REMOVED FROM THE SURFACE SO THAT THEY WILL NOT INTERFERE WITH THE ESTABLISHMENT AND MAINTENANCE OF VEGETATION. SURFACE FOR FINAL SEEDBED PREPARATION, AT FINISH GRADES SHOWN, SHALL BE REASONABLY SMOOTH AND UNIFORM, 4. IF M] SOIL TEST IS TAKEN, FERTILIZER AND LIME TO BE ACCORDING TO SEEDING SPECIFICATIONS ABOVE. IN ADDITION, PROVIDE 15 LBS/1000 S.F. OF SUPER PHOSPHATE. 5. IF SOIL TEST IS TAKEN, PROVIDE LINE AND FERTILIZER ACCORDING TO SOIL TEST REPORT. & LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED VITH THE SON. DURING SEEDBED PREPARATION, CONTRACTOR SHALL INSTALL STORMWATER POND AND EMERGENCY SPILLWAY CONCURRENI WITH EROSION CONTROL MEASURES AND USE POND FOR TEMPORARY SEDIMENT STORAGE. AFTER PERMANENT GROUNDCOVER IS ESTABLISHED, CONTACTOR SHALL DEWATER POND AND REMOVE ACCUMULATED SEDIMENT AND RESTORE POND TO THE GRADE AND CONTOUR INDICATED BELOW. ALTERNATELY, THE CONTRACTOR MAY 'OVER -EXCAVATE' THE POND DURING INITIAL INSTALLATION TO ALLOW FOR SEDIMENT ACCUMULATION. HOWEVER, AFTER PERMANENT GROUNDCOVER IS ESTABLISHED, THE CONTRACTOR WILL BE REQUIRED TO DEMONSTRATE TO THE ENGINEER THAT THE APPROPRIATE GRADE AND CONTOURS ARE PROVIDED, Ew?Ar ATNnv awP'lA ro 5 H.w.T. = O- .Z 5 n 1 D aN U SDi4 e0/1► SEEDING SCHEDULE NOTE, IDLY AREAS ABOVE PERMANENT POOL SWILL DE SEEDED. VEGETATIVE SHELF SHALL NOT BE SEEDED AND SHALL BE ALLOWED TO GENERATE NATIVE VEGETATION. SPREAD 4' TOPSOIL OVER AREAS TO BE SEEDED AND ESTABLISH UNIFORM GRADE PRIOR TO SEEDING. APPLY LINE AND FERTILIZER AND WORK INTO SEED BED, DISTRIBUTE SEED UNIFORMLY AND COVER LIGHTLY. APPLY CLEAN STRAW MULCH OVER SEEDED AREA AND ANCHOR SECURELY WITH STRAIGHT BLADE DISC IN FLAT AREAS AND WITH ASPHALT TAG( WHERE SLOPES EXCEED 4X. MATERIAL APPLICATION RATE LDIE 2 TORS/ACRE 2OX SUPERPHOSPHATE 600 POUNDS/ACRE FERTD.IZER(IO-10-10) IWO POUNO)S/ACRE APRIL - AXY FESCUE, KY-31 50 POUNDS/ACRE BERMUDA (HULLED) 10 POUNDS/ACRE JANUARY - MARCH FESCUE, KY-31 50 POUNDS/ACRE BERMUDA (INHULLED) 20 PONDS/ACRE RYE (GRAIN) 25 POUNDS/ACRE SEPTEMBER - NOVEMBER FESCUE, KY-31 50 PONDS/ACRE MULCH 2 TONS/ACRE ASPHALT TAG( 300 GALLONS/ACRE MOTE, OWNER MAY VARY SEEDING TO CONFORM TO LANDSCAPING REQUIREMENTS, HOWEVER, WEEPING LOVE GRASS SHALL NOT BE USED. Outlet Structure (See Detail) —\ Elev. 'E' (100 yr storm) v 10, Elev. 'D' (10 yr storm.) v 3' Veg. Shelf Elev, 'C' (1'Deslgn ElevJ v Elev. 'B' Vegetated Shelf Plantings (See Planting Scedule) Draw Down Orifice (See Detail) Main Pond RMER R/W CONSTANT POND SURFACE AREA 3,507 S.F. 8 EL= 10.00 1' DESIGN SURFACE AREA = 4,286 S.F. 8 EL= 10.98 APPROX. TOTAL POND VOLUME = 6,415 CF ACTUAL FOREBAY VOLUME = 1,378 CF (21.5 % OF TOTAL VOLUME) PLANTING SCHEDULE PLANTING SCHEALE APPLIES OlY TO VEGETATED SHELF AND VEGETATED FILTER. SPREAD 4' TOPSOIL OVER AREAS TO BE PLANTED AND ESTABLISH UNIFORM GRADE PRIOR TO PLANTING, PLANT ANY TWO 2) OF THE F0.I.OWING SPECIES WITHIN THE LIMITS OT THE DESIGNATED VEGETATED SHELF AT A DENSITY NOT LESS TNAN ONE PLANTING PER SQUARE YARD, cP,_,—.r M93 MW Peltandra vlroM,k COMAILMM Arrow Ar n Arowhead/Duck Potato Broomsedge itL B ass un CnttnR CooMnR Sd Three Square - sw Dudeverd Saururus cernws Lizard Taft HMMscus moscheutos Marsh Hblwcus Pontederh cordata Pkkerelweed Potwwwton Pectlnatus Pond Weed Leersla oryzokles Rice Cutgrass Cam epp. Sedges Sdrpus vaUdus Sofa Stem Bullrush Polygomun spp, Snnrtseed une Jus rffesus Soft Rush NAyhar luteum Spatterdock Pank:um vergatum Swltehprass Acorus calamus Sweet nag Roden canadensls Waterweed Valbnerla anrrlcan* WRd Celery ZNzaMo aquntk:a WRd RIce Treatment Pond - Section Scale: None (Vertically Exaggerated) No 5 Bar 'U' Strap (Coat w/ Bitunastic) 12' No, 57 Stone Embankment shall be constructed of uniform native material (free of excess slit, rock or gravel, debris or vegetative matter) compacted to 95% of maximum dry density In accordance with ASTM D1557 (8'-12' Lifts) Emergency Spillway (100 yr. Flood Elev.) Outlet Pipe (Size and \ Material per Drainage Plan) \-Anti-Seep Collar \-Anil-FLoat Block (See Detail) (60 CF Concrete) y{ BAY JR14/zMAIN a {' loe NORMAL POND / ELEV 10.00 BS.O' I,J_ia& _I w z J aY w z z w U Pond Dimensions & Layout Scale: 1" = 20' TRASH RACK /(SEE DETAIL) 4-3' ALUM ANGLES TOP ELEV 'E' _- PRIMARY WEIR �— ELEV 'C' 2.(2� DIA. CORREGATED ALUM. RISER CONC OUTLET PIPE INV. FILL\ ELEV 'B' Outlet Protection (See Erosion/Sed, Plan) Riser 54' MINIMUM �, Anti -Seep Collar ATE HICK ALUMINUM TRASH RACK ---_� 6'-� RISER (SEE DETAIL) 6' V w z J O' w z z w U WEIR Trash Rack ALUM BAR 2' O.C. 6' DIA. CORR, RISER ALUM. PIPE (SEE DETAIL) OUTLET INVERT DRILL 3/4' HOLE Al IN END CAP - TACK 12, WELD HARDWARE CLOTH_ (; SCREEN OVER ORIFICE 18 MIN' 6' DIA. END CAP Draw Down Orifice Outlet Structure Details FaC�C�� mp oo NOT RELEASED FOR CONSTRUCTION No Scale STORMWATER POND DETAILS HANDY MART#169PREPARED ELEVATIONS SCHEDULE ,:: STORMWATER POND DESIGN BY: FOR LOCATION A-1 DESCRIPTION MAIN POND BOTTOM ELEVATION = ')0 "'''; :.,aUti9. Crystal Coast Engineering, P.A. E.J. POPE &SONS, INC. 5.00 A-2 8 FOREBAY BOTTOM PERMANENT POND 5.DO 10.00 _` - - �' SEAL - Civil and Environmental Consulting Engineers NO. 3 TOWNSHIP, PAMLICO COUNTY, NC C D TEMP. STORAGE 10 YEAR FLOOD 10.95 11.55 = 314g = - David K. Newsom, PE JOHN L. PIERCE PREPARED BY & ASSOCIATES, P.A. E 100 YEAR FLOOD 11.63 �'•. �; ' = 3817-3 FREEDOM WAY, HUBERT, N.C. 28539 409 JOHNSON BLVD. JACKSONVILLE, NC 28540 Ns PHONE: (910) 325-0006 - FAX: (910) 325-0060 PHONE: 910-346-9800 DATE: 2-14-07 SCALE: AS SHOWN F.B. 750 PG. 47+ JOB #268605 FILE NAME: PAMLIICO.ASC REV: 2-20-07 SHEET 4 OF 4