Loading...
HomeMy WebLinkAboutSW6110806_COMPLIANCE_20111028STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW ��Dr�DiQ DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD I Patterson, Robert From: Patterson, Robert Sent: Friday, October 28, 2011 6:51 AM To: 'Tom Goodwin' Subject: SW6110806 - Wedgefield Apartments - Add. Info. Req'st Tom, I received the add. info on 10/27/11. 1 noted that you said you are waiting for the owner to sign the O&Ms. With the change in BMPs and DAs, SWU-101 also needs to be revised and submitted. Please submit this with the original 0&Ms. Thanks. Robert D. Patterson, PE Environmental Engineer NCDRNR I DWQ I Stormwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, Raleigh, NC 27604 1 9ch Floor Location & Parcels (919) 807-6375 Phone 1 (919) 807-6494 Fa I Robert. Pattersonancdenr.eov EtnniI I http://portal. nedenr.org/web/wa/ws/su Website rA Berne printing this email, please consider your budget and the environment. E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute c r other regulation. J October 17, 2011 NCDENR — DWQ Stormwater Permitting Unit 512 N. Salisbury St. Raleigh, NC 27699-1617 Attn: Robert D. Patterson, PE Re: Wedgefield Apartments HUA Job #HC1108 Dear Mr. Patterson, 90 Hobbs Upchurch Associates eriginaenny I plarmung 1 �urveying Q���aec o OCT 2 7 2011WATR D klAA1 AM, S NTERITY BRANCH In reference to your emailed comments from August 30, 2011, the following are the responses to those comments made by your office for the above named project and our responses are as follows: 1. Please provide the original signed O&M Agreements; only copies were provided. Waiting for the signed forms from the owner, will provide when received.. 2. Any wetlands and surface waters must be shown; or provided a note on the plans that non exist, if that is the case. Note included on Sheet C-4. 3. Is the pipe from 0#8 labeled correctly as being 58"? Size has been corrected. 4. Please provide the HGL information for the 48" pipe that the 3 bioretention cells (cells) will be discharging to. Please demonstrate that there will not be backwater issues for the cells. Invert of 4" PVC underdrain is above the top of the existing 42" pipe which was sized for the 100 yr storm. 5. For all 3 cells, the required 2' separation from the SHWT has not been provided as required. The separation is measured from the bottom of the stone/underdrain elevation down to the SHWT elevations provided in the soils report. Two of the bioretention cells have been eliminated. The remaining cell has 1.84' of clearance from the bottom of the gravel layer and the SHWT. There has been a wetlands area incorporated into the design better utilizing the elevation of the SHWT. 6. Please verify and revise as needed the elevations for cell #3 and associated riser. The elevations are not consistent between the supplement form and sheets C-3 and D-10. Revised and corrected. 7. On sheet D-10: a. The schedule shows grassed cells, but also shows 4" of mulch. There should not be a mulch layer in grassed cells. Removed the detail to show grass and no mulch. Grass cells must be sodded. Please specify that sod be used in the detail, along with the species of grass. Added note to specify sod. T: 910.692.5616 I F: 910.6921342 1 300 SW BROAD STREET I SOUTHERN PINES, NC 28388 I WWW.HOBBSUPCHURCH.COM SUPERIOR PERFORMANCE THROUGH INNOVATIVE DESIGN Page 2 of 2 c. The bottom of cell values in the schedule do not account for the stone and underdrain layer depth. Please revise. Made appropriate revisions to the schedule. d. Please provide details for the riser structures. Added a yard inlet detail to be used as the riser. e. The cell detail needs to be more site specific than the generic detail from the BMP Manual. It should state the site and cell specific depths of the different layers, ponding depth, whether filter fabric or choke stone will be used, underdrain specifics, etc. Changed to a site specific detail. If you should have any questions or concerns during your review, please do not hesitate to contact this office. Sincerely, HOBBS, UPCHURCH & ASSOCIATES, P.A. 'e ;4' Thomas K. Goodwin, P.E. Division Manager Transportation and Site Development Division Patterson, Robert From: Patterson, Robert' Sent: Tuesday, October04, 2011 8:53 AM To: 'Tom Goodwin' Cc: Frank Wanko Subject: RE: Wedgefield Apartment Storm Water Plan Tom, That sounds fine. Please submit the requested additional information no later than October 24, 2011. Thanks. Robert D. Patterson, PE Environmental Engineer NCDF,NR I DWQ I Stormwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, Raleigh, NC 27604 1 9t" Floor Location &. ParCCIS (919) 807-6375 Phone 1 (919) 807-6494 Fax I Roberr.Patterso oncdenegov Email I http://portal.ncdenr.org/web/wa/ws/su Website .A Before printing this email, please consider your budget and the environment. E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Tom Goodwin f mailto:TGoodwin(@hobbsupchurch.coml Sent: Tuesday, October 04, 2011 8:50 AM To: Patterson, Robert Cc: Frank Wanko Subject: Wedgefield Apartment Storm Water Plan Mr. Patterson — As you are aware, Hobbs Upchurch has been investigating alternative designs for the storm water ponds submitted for review due to the high Seasonal High Water table. As such, we are requesting an additional three weeks extension for the period set for us to resubmit the plan to DWQ. If you have any questions, concerns, or comments, please let me know. Tom Goodwin, P.E. Division Manager, Transportation & Site Development Division Hobbs Upchurch & Associates 300 SW Broad Street / PO Box 1737 / Southern Pines, NC 28388 Phone (910) 692-5616 / Fax (910) 692-7342 / Cell (910) 585-2489 m. _=.-._lam � � -�� •� _� � �� WEDGE REI-D.J I .. _PHASE 3 11 � US HWr am 1�► T - g 3 L 0'T-7 )zA UOT5 3-71 W." or -