Loading...
HomeMy WebLinkAboutSW6100602_COMPLIANCE_20120504STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SWIW" - DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD I North Carolina Beverly Eaves Perdue Governor Directorate of Public Works Attn: Gregory G. Bean 2175 Reilly Road, Stop A Fort Bragg, NC 28310-5000 NC®ENR Department of Environment and Division of Water Quality Charles Wakild, PE Director May 4, 2012 Subject: Compliance Evaluation Inspection State Stormwater Management Permit SW6100602 SOF TUAV Hangar Facility Cumberland County Dear Mr. Bean: Natural Resources Dee Freeman Secretary On May 2, 2012, I, Michael Lawyer from the Fayetteville Regional Office of the Division of Water Quality conducted a Compliance Evaluation Inspection at the SOF TUAV Hangar Facility located at the intersection of Yadkin Road and Canopy Lane, Fort Bragg, Cumberland County, North Carolina. The purpose of the inspection was to ensure compliance with State Stormwater Management Permit SW6100602, which was issued on June 30, 2010. A copy of the Compliance Inspection Report is enclosed for your review. As a result of the inspection and file review, it has been determined that the facility is in compliance with the subject permit and approved plans. However, a signed Designer's Certification has not been received by this office and needs to be submitted. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. If you have any questions or this office can be of any assistance, please contact me all (910) 433-3329 or by e-mail at mike.lawyer@ncdenr.gov Sincere) , Michael/ Lawyer, CPSWQ Environmental Specialist Enclosure _Water Maragement Branch (via a -mail) Stormwater Permitting Unit FRO -Surface Water Protection Location. 225 Green Street, Suite 714, Fayetteville, North Carolina 28301 Phone: 910A33-33001 FAX 910486-07071 Customer Service. 1-877-623-6748 Internet: httpalportal.ncdenr.orglweblwq An Equal Oppo trinity 1 Affirmative Action Employer One NorthCarolina Naturally Compliance Inspection Report Permit: SW6100602 Effective: 06/30/10 Expiration: 12/31/21 Owner: Directorate of Public Works Ft Bragg Project: SOF TUAV Hanger Facility County: Cumberland Yadkin Rd Region: Fayetteville - Contact Person: Craig Lantz Title: Directions to Project: Intersection of Yadkin Road & Canopy Lane Type of Project: State Stormwater - HD - Sand filters Drain Areas: 001 - (Stewarts Creek)(03-06-15)( C) On -Site Representative(s): Related Permits: Fort Bragg NC 28310 Phone: 916-396-2301 Inspection Date: 05/02/2012 En/try Time: 01:15 P Exit Time: 02:00 PM Primary Inspector: Mike Lawyer �h//� Phone: 910-433-3300 Secondary Inspector(s): ( E4129 4. 331M Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: State Stormwater Facility Status: ■ Compliant Q Not Compliant Question Areas: E State Stormwater (See attachment summary) Page: 1 Permit: SW6100602 Owner - Project: Directorate of Public Works Ft Bragg Inspection Date: 05/02/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Observations were made of the built -upon area, drainage pattern and sand filter system. All appeared to be constructed per the approved plans and permit. Upon subsequent file review, a signed Designer's Certification has not been received by the regional office, which should have been submitted upon completion of construction and prior to operation of the BMP. File Review Yes No NA NE Is the permit active? ■ ❑ ❑ ❑ Signed copy of the Engineer's certification is in the file? ❑ ■ ❑ ❑ Signed copy of the Operation & Maintenance Agreement is in the file? ■ ❑ ❑ ❑ Copy of the recorded deed restrictions is in the file? ❑ ❑ ■ ❑ Comment: A signed copy of the Designer's Certification is not in the file and needs to be submitted. Built Upon Area Yes No NA NE Is the site BUA constructed as per the permit and approval plans? ■ ❑ ❑ ❑ Is the drainage area as per the permit and approved plans? ■ ❑ ❑ ❑ Is the BUA (as permitted) graded such that the runoff drains to the system? ■ ❑ ❑ ❑ Comment: SW Measures Yes No NA NE Are the SW measures constructed as per the approved plans? ■ ❑ ❑ ❑ Are the inlets located per the approved plans? ■ ❑ ❑ ❑ Are the outlet structures located per the approved plans? ■ ❑ ❑ ❑ Comment: Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ■ ❑ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to DWO ❑ ❑ ❑ ■ upon request? Comment: ---- OtherPermitConditions - -- Yes No NA NE Is the site compliant with other conditions of the permit? ■ ❑ ❑ ❑ Comment: Other WQ Issues Yes No NA NE Is the site compliant with other water quality issues as noted during the inspection? ■ ❑ ❑ ❑ Comment: Page: 2 Patterson, Robert From: Patterson, Robert DE['�V�' ��� Sent: Wednesday, June 23, 2010 1:01 PM y To: jzamudio@fsb-ae.com Subject: SW6100602 - SOF TUAV Hangar Facility - Additional Information Request JUL 33 0 1U10 Juan, ®o Q I spoke to Fred a few minutes ago about these items. I didn't have his email address with me at the moment, so I'm sending this to you. Please note that the project number has changed. You only need to submit items that have changed (2 copie< of plans that change, talcs that change, supplement forms that change, etc.) The Division of Water Quality Central Office received a Stormwater Management Permit Application for the subject project on June 15, 2010. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. The concrete level spreader at the entrance to the forebay does not need to be 10-feet wide for DWQ requirements. It can be reduced to the width of a curb. Chapter 8 of the BMP Manual has examples of typical level spreaders,. 2. Clean outs need to be provided for the sand filter underdrains. 3. The sod and topsoil should be removed from the surface of the sand media. This will potentially reduce infiltration rates and increase clogging. Having exposed sand will make future maintenance easier as well. Surge stone or similar is allowed on the top of the sand if you so choose. 4. The 6-inch pipe from the trench drain should discharge into the forebay, instead of directly to the sand chamber. 5. The sand filter profile on sheet C-506 shows 1' to 6" of sand media depth. A minimum of 18" of sand media total depth is required, with at least 12" above the underdrains. 6. Storage for the adjusted water quality volume (2,378 cf) must be provided between the sediment chamber and above the sand media in the sand chamber. Based on the overflow weir elevation (364') from the sand chamber, there is no storage above the sand media. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to July 23, 2010, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail, fax, or email your request for a time extension to the Division at the address and fax number at the bottom of this email. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. 1 Please reference the State assigned project number SW6100602 on all correspondence. If you have any questions concerning this matter please feel free to call me at (919) 807-6375. Robert D. Patterson, PE Environmental Engineer NCDENR I DWQ I Stormwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 (Mail) 512 N. Salisbury St, Raleigh, NC 27604 (Location & Parcels) (919) 807-6375 Phone 1 (919) 807-6494 Fax Email: robert.pattersonpncdenr.Rov Website: http://portal.ncdenr.org/web/wq/ws/su Before printing this email, please consider your budget and the environment. E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 2