Loading...
HomeMy WebLinkAboutSW6100103_COMPLIANCE_20121003STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW l tl2o Z223 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE �2 YYYYMMDD ®ENR—FRO Noah Woods, Chairman Tom Taylor, Vice -Chairman County Attorney J. Ilal Kinlaw, Jr. September 21, 2012 ROBESON COUNTY Board of Commissioners Commissioners Raymond Cummings Lance Herndon David Edge Roger Oxendine Ricky Harris, County Manager NCDENR ATTN: Belinda S. Henson 225 Green Street, Suite 714 Fayetteville, NC 28301 Deputy Clerk to the Board Hope Bra) boy RE: Notice of Violation (NOV-2012-13CO295) Robeson County DSS Facility Dear Ms. I -Jenson: OCT 0 3 2012 M Hubert Staley Jerry Stephens Clerk to the Board Tammy S. Freeman Robeson County is in receipt of the Notice of Violation (NOV-2012-PCO295) dated August 28, 2012. We are aware of the fact that the Gate Valve at the Wet Detention Pond is not properly maintaining a seal, thus allowing water to escape from the pond. Robeson County and our Maintenance Department understand that this gate valve is only to be used in the case of an emergency or to perform maintenance on the pond or its structures. Currently we are working with the Engineer of Record and the contractors responsible for the gate valves installation to correct this issue. With regard to the areas of the pond which need to be replanted/re-vegetated, this would be a warranty issue since the groundcover was not established in the allowed grow -in period. We have contacted the responsible landscaping company and will ensure that this area is brought into compliance. We anticipate that the corrective measures required will be complete by the end of November 2012. 701 North Elm Street ♦ Lumberton, North Carolina 28358 ♦ Phone (910) 671-3022 ♦ Fax Number: (910) 671-3010 ivww. co. robeson. ne. us U.S. Postal Services/ CERTIFIED MAIL,, RECEIPT (Domestic Mail Only; No Insurance Coverage Provided) -' delivery Information www.usps.coma For visit our website at ru F— f� S Postage 9 , N O Cenlfled Fee ' P oStolatir 0 Return Receipt Fee Here C3 (Endomement Required) ffi ' C3 Restricted Delivery Fee (Endorsement Required) ))) fU Total Postage a 8 Fees / O Er p r.. Sent To ro or PO Box Avo. /.�// l J ' C/y, State, Z%h4 ._.. - PS :,, August,, V r6e-e Reverse for Instructions ■ complete Items 1, 2, and 3. Also complete Item 4 if Restricted Delivery Is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the Tailpiece, . or on the front if space permits. 1. Article Addressed to: 2. Article Number- j (transfer from service WW Ps Form 3811, February 2004 A. /)6 _u!,_ _47--'0 Agent — G. Date of Delivery Received by (printed Name)l I— D. Is delivery address different from item t 7 ❑ Yes If YES, enter delivery address below: 0 No 3. Service lype sNged Mall ❑Express Mall ❑ Registered Return Receipt for Merchandise ❑ Insured Mall ❑ C.O.D. 4, Restricted Dellvery'I (Even Fee) ❑ Yes 1',7009 0820 0000 Domestic Saturn Receipt or NC®ENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor CERTIFIED MAIL: 7009 0820 0000 2474 1855 RETURN RECEIPT REQUESTED County of Robeson Attn: Ricky Harris, County Manager 701 North Elm Street Lumberton, NC 28358 Division of Water Quality Charles Wakild, PE Director August 28, 2012 Subject: NOTICE OF VIOLATION (NOV-2012-PC-0295) Stormwater Management Permit SW6100103 Robeson County DSS Facility Robeson County Dear Mr. Harris: Dee Freeman Secretary On August 21, 2012, Michael Lawyer, Environmental Specialist from the Fayetteville Regional Office of the Division of Water Quality conducted a Compliance Evaluation Inspection at the Robeson County DSS Facility located at 120 Glen Cowan Road in Lumberton, Robeson County, North Carolina. The purpose of the inspection was to ensure compliance with Stormwater Management Permit SW6100103 that was issued on February 15, 2010. A copy of the Compliance Inspection Report is enclosed for your review. As a result of the inspection and subsequent file review, it has been determined that the facility is Not Compliant. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. The required actions that are necessary to bring this site into compliance are noted under the Inspection Summary and Comments sections of the report. You are asked to provide this office a written/typed response within 30 calendar days from receipt of this letter. Your response should specify actions that will be undertaken and the time frame that will be required to correct the deficiencies as well as copies of any maintenance records as required by Section II, Item 4 of the permit. Failure to properly resolve the violation(s) may constitute the assessment of a civil penalty of up to $25,000 per day, per violation. If you have any questions or this office can be of any assistance, please contact Mr. Lawyer at (910) 433-3329 or by e-mail at mike.lawyer@ncdenr.gov Sincerely, i4j,0C) J. iwx�� Belinda S. Henson Regional Supervisor Surface Water Protection Section BSH: ML/ml Enclosure cc: Samuel J. Powers, PE - Anderson Engineering & Associates, PA (via e-mail) FRO - Surface Water Protection Section - Location: 225 Green Street. Suite 714, Fayetteville, North Carolina 28301 Phone: 91 OA33-33001 FAX: 910486-07071 Customer Service: 1-877-623-6748 Internet: httpalportal.ncdenr.orglwetilwq An Equal Opportunity'. Affirmative Action Employer NorthCarolina Naturally Compliance Inspection Report Permit: SW6100103 Effective: 02/15/10 Expiration: 12/29/21 Owner: County of Robeson Project: Robeson County DSS Facility (SSW) County: Robeson 120 Glen Cowan Rd SO 547 Region: Fayetteville Lumberton INC 28360 Contact Person: Sam Isham Title: Phone: 910-521-8013 Directions to Project: Take Exit 17 from 1-95, head west on INC Hwy 711 for approx. 0.78 mi, turn right on SR 1547 (Glen Cowan Rd). Proposed main entrance for development will be approx. 450 feet north of the NC Hwy 711-SR 1547 intersection on left. Type of Project: State Stormwater - HD - Detention Pond Drain Areas: 1 - (LUMBER RIVER) (03-07-51) ( WS-IV,B;Sw,HQW) On -Site Representative(s): Related Permits: Inspection Date: 08/21/2012 Entry Time: 12,43 P Exit Time: 01:10 PM Primary Inspector: Mike Lawyer �Phone: 910-433-3300 Secondary Inspector(s) : ExLY2g- 33Z9 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ■ Not Compliant Question Areas: State Stormwater (See attachment summary) Page:1 Permit: SW6100103 Owner - Project: County of Robeson Inspection Date: 08/21/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted to ensure compliance with the conditions of Stormwater Management Permit SW6100103. Proposed built -upon area, drainage system, and wet detention pond appeared to be installed per the approved plans. Pond was discharging at the time of inspection through open gate valve at the bottom of the outlet structure instead of the approved drawdown devices. This does not allow the pond to reach its designed and approved permanent pool. Certain areas of the vegetative shelf and side slopes appeared to be in need of re-planting/re-vegetation. Page: 2 Permit: SW6100103 Owner - Project: County of Robeson Inspection Date: 08/21/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine File Review Yes No NA NE Is the permit active? ■ 0 0 0 Signed copy of the Engineer's certification is in the file? Signed copy of the Operation & Maintenance Agreement is in the file? Copy of the recorded deed restrictions is in the file? Comment: Built Upon Area Is the site BUA constructed as per the permit and approval plans? Is the drainage area as per the permit and approved plans? Is the BUA (as permitted) graded such that the runoff drains to the system? Comment: SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: ■000 ■nnn 00■0 Yes No NA NE ■nnn ■000 ■000 Yes No NA NE ■000 ■nnn ■nnn Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? 0 ■ ❑ 0 Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ 0 D D ■ upon request? Comment: At -the time of inspection, pond was discharging through open gate valve at bottom of outlet structure instead of approved drawdown devices. Sections of the vegetative shelf appeared to need re -planting and several areas including, but not limited to the back side slope and adjacent to the fire lane also need to be re -vegetated. Other Permit Conditions Yes No NA NE Is the site compliant with other conditions of the permit? ■ 0 ❑ Comment: Other WQ Issues Yes No NA NE Is the site compliant with other water quality issues as noted during the inspection? ■ 0 ❑ ❑ Comment: Page:3 Lawyer, Mike From: Sam Powers [sampowers@bellsouth.net] Sent: Wednesday, February 10, 2010 1:20 PM To: Lawyer, Mike Cc: 'Larry W. Anderson'; 'Wesley Anderson'; 'Eric Schoenagel'; 'Sam' Subject: DSS SW Permit Attachments: DSS - SW Permit App - Revised Page 3 (2-10-2010).pdf; DSS - REVISED Wet Detention Basin Supplement (02-10-2010).pdf; DSS Retention REVISED 2010-02-10.pdf Mike, Please find attached the revised documentation on the DSS project as we discussed on the phone. I am sending the revised page 3 of the permit application, the revised wet detention basin supplement form, and the revised supporting calculations. I have changed all these documents to reflect 30 acres as the project area and total build -out of 21 acres, which will be the maximum allowed impervious area since there can be no more than 70% of the site covered by impervious area due to the fact that it is located in a water supply watershed (WS-IV). Please note that the plans and the wet detention basin layout as previously submitted to you have NOT changed as a result of these revisions. Should you require any additional information, please do not hesitate to contact me. Thanks! Samuel J. Powers, PE ANDERSON ENGINEERING & ASSOCIATES, PA 305 N. Chippewa Street Lumberton, NC 28358 Bus: (910) 671-9530 Fax: (910) 618.0838 4. Local jurisdiction for building permits: City of Lumberton Planning & Inspections Department Point of Contact:Brandon Love, Director IV. PROJECT INFORMATION Phone #: (910 ) 671 3976 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: El Valid Building Permit Issued Date: ❑ Other: Date: b. identify the regulation(s) the rol'ect has been designed in accordance with: ❑ Coastal SW -1995 Ph II - Post Construction 3. Stormwater runoff from this project drains to the Lumber River basin. 4. Total Property Area: 30.0 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area': 30.0 acres Total project area shall be calculated to exclude the following: the normal pool of imppounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NHW) line or Mean High Water (MHW) line, and coastal roetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (BUA). Non -coastal roetlands landward of the NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 9. How many drainage areas does the project have?1 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. ;Basirfdn ormation ^ ;;;?fig F .:':_ . Drainage -Area 1; Brainag e Area :_l 0raina e'Area' °�s Draina e'Area Receiving Stream Name Lumber River Stream Class " WS-IV,B; Sw,H W Stream Index Number • 14-(7) Total Drainage Area (sf) 1,306,800 On -site Drainage Area (sf) 1,306,800 Off -site Drainage Area (s 0 Proposed Impervious Area" (sf) 914,760 Impervious Area" (total) 70.0 ;Im ivi6us".SurfaceiArea• ', �i rDraina e Areal. :Drain` e=Area t' 'Drama e,Area._a1 ;Drain e Area On -site Buildings/Lots (so 52,707.6 On -site Streets (so 0 On -site Parking (sf) 248,727.6 On -site Sidewalks (sf) 14,810.4 Other on -site (sf) 0 Future (sf) 598,514.4 Off -site (sf) 0 Existing BUA*" (sf) 0 Total (sf): 914,760 " Stream Class and Index Number can be determined at: http://h2o.enr.state.nc.uslbittis/reportslreportsWB.Iitnd Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-I01 Version 07July2009 Page 3 of 6 Permit No5e�l ec 3 to, be provOea by DWOJ OF W A TFH NCDENR o�z STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form must be filled out, printed and submitted. The Required Items Checklist (Part III) must be printed, filled out and submitted along with all of the required information. L"PROJECTANFORMATI0N .9rat 'r"'-'nc ,.itlF'. x,'tt racy T. :. s „R, zJ�x, nr..ra. =ot, 3 a,�°�„� .?Y .%r,,ta ,✓> .:��.1�`,..,..,„. ,'„ h"3,. 'a -: s1Yr Project name Robeson County DSS Facility Contact person Sam Powers, PE Phone number 910.671.9530 Date 2/10I2010 Drainage area number 1 IWDESIGN She Characteristics Drainage area 1,306,800 ft2 Impervious area, post -development 914,760 it %impervious 70.00 % Design rainfall depth 1.0 in StorageVolume: Non-SAWaters Minimum volume required 74,052 ft3 OK Volume provided 152,733 fta OK, volume provided is equal to or in excess of volume required. Storage Volume: SA Waters 1.5' runoff volume ft3 Pre -development 1-yr. 24-hr ranch ft3 Post -development 1-yr, 24-hr runoff ft3 Minimum volume required its Volume provided It Peak Flow Calculations Is the pre/post control of the lyr 24hr storm peak flow required? N (Y or N) ��� H R p 1-yr, 24-hr rainfall depth in -? ��P.•'SS• Rational C, predevelopmenl (unilless) Rational C, post -development hss) _ Rainfall intensity:: 1-y4 24-hr storm in/h intr 6 9 Pre -development 1-yr, 24-hr peak flow fts/sec Post -development l-yr, 24-hr peak flow ftt/sec ciyG Q;'•C Pre/Post 1-yr, 24-hr peak flow control ftslsec Elevations Temporary pool elevation Permanem pod elevation 136.00 fmsl 133.50 fmsl SH WT elevation (approx. at the perm. pool elevation) 134.00 fatal Top of loft vegetated shelf elevation 134.00 fmsl Bottom of 10ft vegetated shelf elevation 133.00 find Sediment deanout, top elevation (bottom of pond) 130.00 fmsl Sediment deanout bottom eleval'lon 129.00 fmsl Sediment storage provided 1.00 ft Is there additional volume stored above the state -required temp. pool? Y (Y or N) Elevation of the top of the additional volume 136.0 fmsl OK Form SW401-Wet Detention Bask-Rev.8-9/17109 Parts I. a II. Design Summary. Page 1 of Permit No4/W 16" 163 (to De PmvNea DY DWD) IIi DESIGN INFORMATION+1 .v...tli',-,v,J° aj?FF ",ro.v:,`$)i.'a Surface Areas Area, temporary pool 73,066 ft' Area REQUIRED, permanent pod 52,272 ft SA/DA ratio 4.00 (unities) Area PROVIDED, permanent pod, Ap,,,,_,� 54,899 112 OK Area, bottom of ?Oft vegetated shelf, A, ,MI 46,166 W Area, sediment deanout, top elevation (bottom of pond), A . 35,231 it Volumes Volume, lempomry pool 152.733 ft' OK Volume, permanent pool, Vy. 164,792 fls Volume, forebay (sum of fombays if more than one forebay) 34,W4 ft' Forebay % of permanent pool volume 20.6% % OK SAIDA Table Data Design TSS removal 90 % Coastal SAIDA Table Used? N (Y or N) Mountain/Piedmont SAIDA Table Used? Y (Y or N) SAIDA ratio 4.00 (unit ess) Average depth (used in SAIDA fade): Calculation option 1 used? (See Figure 10-2b) N (Y or N) Volume, permanent pod, Vp,,,,_,, 164,792 ft' Area provided, permanent pool, A� 54,899 ft Average depth calculated 3.DO It OK Average depth used in SAIDA, d,,, (Round to nearest 0.5ft) 3.0 It OK Calculation option 2 used? (See Figure 10-2b) Y (Y or N) Area provided, permanent pod, A,_,. 54.899 ft Area, bottom of 1 Oft vegetated shelf, A., 46,166 fit` Area, sediment deanouL top elevation (bottom of pond), A,,„ 35,231 rye 'Depth' (distance b/w bottom of 10ft shell and top of sediment) 3.00 ft Average depth calculated 3.10 ft OK Average depth used in SAIDA, d„, (Round to nearest 0.5ft) 3.0 ft OK Drawdown Calculations Drawdown through office? Diameter of office (d circdar) Area of orifice (if-wncircular) Coefficient of discharge (Cu) Diving head (Ha) Drawdown through weir? Weir type Coefficient of discharge (Q,) Length of weir (L) Driving head (H) Pre -development 1-yr, 24-hr peak flax Post -development 1-yr, 24-hr peak flow Storage volume discharge rate (through discharge orifice or weir) Storage volume drawdaxm time Additional Information Vegetated side slopes Vegetated shell dope Vegetated shelf width Length of flowperh to width ratio Length to width ratio Trash rack for overflow & orifice? Freeboard provided Vegetated filter provided? Recorded drainage easemed provided? Capures all mnoft at ultimate build -out? Drain mechanism for maintenance or emergencies is: Y (Y or N) 4.00 in In 0.60 (unilless) 0.83 It N (Y or N) (unilless) it It ft'/sec ft'Isec 0.77 ft'/sec Storage volume discharge rate greater than pm-dev. lyr24hr. 2.30 days OK, draws down in 2-5 days. 3:1 OK 10 :1 OK 10.0 it OK 3:1 OK 6.0 :1 OK Y (Y or N) OK 1.Oft OK N (Y or N) OK Y (Y or N) OK Y (Y or N) OK Gravity drain, B' Waterman CL-16 Canal 'Sluice' Gate Faro SW401-Wet Detention Basin-Rev.8-9119N9 Pans I. & II. Design Summary, Page 2 012 STORMWATER RETENTION CALCULATIONS Project: Robeson County DSS Facility By: Sip Date: 2/10/10 (Rev.) Job #: 60-1214 O; STAGE -STORAGE FUNCTION (ABOVE PERMANENT POOL) S Z 133.50 0 0 0.0 134.00 63756.65 15939 15939 0.5 9,6765 -0.6931 0.49 135.00 68383.00 66070 82009 1.5 11.3146 0.4055 1.60 136.00 73065.84 70724 152733 2.5 11.9364 0.9163 2.50 137.00 77805.80 75436 228169 3.5 12.3378 1.2528 3.35 Constant (y-Intercept) 10.66931 Ks = 43015 Slope (X Coefficient) 1.37567 b = 1.38000 Standard Error of Coefficient 0.07825 RZ = 0.99703 STAGE -STORAGE FUNCTION log -log plot 1---14:0000 I 12:0000� - i - 000 8:0000 y y = 1.3757x + 10.669 I - 0 Seriesl c ' 6:0000 Rz=0.997 -Linear (Seriesl) -40000 20000 �0:0000 -1.0000-0.5000 0.0000 0.5000 1.0000 1,5000 In Z Future Impervious Area= 13.74ac \\\\�N1ICq////// Proposed Asphalt Area = 5.71 ac S Proposed Building Area (Roof) = 1.21 aczz _. Proposed Concrete Area = 0.34 ac a Treated Pervious, Prop. Medians = 1.47 ac _= 3 •w� a Treated Pervious Area, Lawn = 2.95 ac J • FN Q , Untreated Pervious Area, Woods = 2.79 ac IN i���UF Pond Area = 1.79 ac td t P0�\\�� Total Drainage Area = 30.00 ac qy / 1 0 l Zo,o (VXV) STORMWATER RETENTION CALCULATIONS Project: Robeson County DSS Facility By: Sip Date: 2/10/10 (Rev.) Job #: 60-1214 Runoff Coefficient, C: Pre -Development ID Area (ac) C` C x A Unimproved cleared area 27.21 0.35 9.52 Wooded, Sparse Ground Litter 2.79 0.20 0.56 Total 30.00 10.08 C,, = 0.34 Post -Development UNTREATED RUNOFF (PERVIOUS AREAS ONLY) ID Area (ac) C. C x A Wooded, Sparse Ground Litter 2.79 0.20 0.56 Lawn, dense soil, flat 2% 0.00 0.17 0.00 Future Impervious Area 0.00 0.85 0.00 Total 2.79 0.56 C� = 0.20 TREATED RUNOFF ID Area (ac) C. C x A Roof, inclined 1.21 1.00 1.21 Street, driveway, sidewalk 6.05 0.95 5.75 Lawn, dense soil, flat 2% 4.42 0.17 0.75 Pond Area 1.79 1.00 1.79 Future Impervious Area 13.74 0.95 13.05 Total 27.21 22.55 C� = 0.83 'Source: Elements of Urban Stormwater Design by H. Rooney Malcolm, P.E. - Exhibit 1 Storm Intensit L = 1500 ft �' H = 10.5 ft T� = 14.72 min Ly) T,. = 128 Say 15 min Design Storn 10 year Location: Lumberton, NC Duration Intensity [min] [in/hr] 10 6.48 15 110 15 5.46 So, 110 = 5.46 UNTREATED Qp = C x Ito x A = 3.05 cfs TREATED Qp = C x I10 x A = 123.31 cfs STORMWATER RETENTION CALCULATIONS ". Project: Robeson County DSS Facility By: Sip Date: 2/10110 (Rev.) Job #: 60-1214 / Estimate Volume of Runoff. V P1,10 = 2.58 in Storm: 1-hr 10 yr Location: Lumberton, NC SCS CURVE NUMBER: Soil Type: Goldsboro Hydrologic Soil Group: B 32% Faceville B 24% Lynchburg C 14% Rains B/D 16% Lakeland A 13% Wagram A 1% ID Area (ac) CN' CN x A Impervious - Roof 1.21 98 118.58 Impervious - Parking lot, Sidewalk 6.05 98 592.90 Pond Area 1.79 98 175.42 Woods, Fair 2.79 60 167.40 Lawn, Good condition 4.42 61 269.62 Future Impervious Area 13.74 98 1346.52 Total 30.00 2670.44 CNarf= 89 `Source: NC Erosion and Sediment Control Planning and Design Manual - Tables 8.03(e) - (g) S= -10 1000 (P- 0.2 Sy' Q - CN P+0.8 S S = 1.24 in Q. = 1.52 in V=Q*xA= 150618 cf ID Area (ac) Imperviousnp. Area (ac) Impervious - Roof 1.21 100% 1.21 Impervious - Parking lot, Sidewalk 6.05 100% 6.05 Pond Area 1.79 0% 0.00 Wooded, Sparse Ground Litter 2.79 0% 0.00 Lawn, Grass Medians 4.42 0% 0.00 Future Impervious Area 13.74 100% 13.74 Total 30.00 21_00 Time to Peak. T.,: T � 139 Q v SIMPLE METHOD Rp = 1.0 in RV.=0.05+0.9*IA IA= 70% V=3630*Ru *RV *A Rv= 0.68 in/in V = 74052 cf Tp = 14.6 min STORMWATER RETENTION CALCULATIONS Project: Robeson County DSS Facility By: Sip Date: 2/10/10 (Rev.) Job #: 60-1214 Allowable Discharge (Pre -development Conditions): Qall = Qpre = Cpre x 110 x A CPRE = 0.34 I10 = 5.46 cfs A = 30.00 ac Qa11 = Qpre = 55.69 cfs Peak Inflow* = 121.96 cfs Peak Unrestricted Outflow = 3.05 cfs Peak Pond Outflow* = 1.27 cfs Peak Elevation* = 135.97 ft Top of Pond El. [ft] = 137.00 Peak Storage* = 149732 cf Storage Avail.[cf] = 152733 Actual Allowed cfs cfs 4.32 < 55.69 OK! `See Storm Routing on Next Page OK! OK! STORM ROUTING Pipe (Orifice): V-Notch: Input Data: N 2 Q = C[tan(0/2)]H112 Qp 123.31 cfs Cd 0.6 C = 2.5 Tp 15 min D 4 0 = 0 degrees AT 2 min Zi 133.50 0 = 0.0000 radians Weir: Invert = 134.00 feet Ks 43015 Cw 3.0 b 1.38000 L 12.0 ft Zcr 136.00 ft TIME INFLOW STORAGE STAGE ORIFICE V-NOTCH WEIR OUTFLOW [min] [cfs] [ft3] IN [cfs] [cfs] [cfs] [cfs] 0 0.00 0 133.50 0 0.00 0.00 0.00 2 5.33 0 133.50 0.00 0.00 0.00 0.00 4 20.40 640 133.55 0.02 0.00 0.00 0.02 6 42.60 3085 133.65 0.10 0.00 0.00 0.10 8 68.10 8186 133.80 0.29 0.00 0.00 0.29 10 92.48 16322 134.00 0.48 0.00 0.00 0.48 12 111.54 27362 134.22 0.62 0.00 0.00 0.62 14 121.96 40672 134.46 0.75 0.00 0.00 0.75 16 121.96 55218 134.70 0.85 0.00 0.00 0.85 18 111.54 69751 134.92 0.94 0.00 0.00 0.94 20 94.56 83022 135.11 1.01 0.00 0.00 1.01 22 79.51 94249 135.27 1.06 0.00 0.00 1.06 24 66.86 103663 135.39 1.10 0.00 0.00 1.10 26 56.22 111554 135.49 1.13 0.00 0.00 1.13 28 47.27 118164 135.58 1.16 0.00 0.00 1.16 30 39.75 123697 135.65 1.18 0.00 0.00 1.18 32 33.42 128325 135.71 1.20 0.00 0.00 1.20 34 28.10 132192 135.76 1.21 0.00 0.00 1.21 STORMWATER RETENTION CALCULATIONS Project: Robeson County DSS Facility By: Sip Date: 2/10/10 (Rev.) Job #: 60-1214 36 23.63 135419 135.80 1.22 0.00 0.00 1.22 38 19.87 138108 135.83 1.23 0.00 0.00 1.23 40 16.71 140344 135.86 1.24 0.00 0.00 1.24 42 14.05 142200 135.88 1.25 0.00 0.00 1.25 44 11.81 143737 135.90 1.25 0.00 0.00 1.25 46 9.93 145004 135.91 1.26 0.00 0.00 1.26 48 8.35 146045 135.92 1.26 0.00 0.00 1.26 50 7.02 146896 135.94 1.26 0.00 0.00 1.26 52 5.91 147587 135.94 1.27 0.00 0.00 1.27 54 4.97 148144 135.95 1.27 0.00 0.00 1.27 56 4.18 148588 135.96 1.27 0.00 0.00 1.27 58 3.51 148936 135.96 1.27 0.00 0.00 1.27 60 2.95 149205 135.96 1.27 0.00 0.00 1.27 62 2.48 149407 135.97 1.27 0.00 0.00 1.27 64 2.09 149552 135.97 1.27 0.00 0.00 1.27 66 1.76 149650 135.97 1.27 0.00 0.00 1.27 68 1.48 149708 135.97 1.27 0.00 0.00 1.27 70 1.24 149732 135.97 1.27 0.00 0.00 1.27 72 1.04 149728 135.97 1.27 0.00 0.00 1.27 74 0.88 149701 135.97 1.27 0.00 0.00 1.27 76 0.74 149653 135.97 1.27 0.00 0.00 1.27 78 0.62 149589 135.97 1.27 0.00 0.00 1.27 80 0.52 149511 135.97 1.27 0.00 0.00 1.27 82 0.44 149421 135.97 1.27 0.00 0.00 1.27 84 0.37 149321 135.96 1.27 0.00 0.00 1.27 86 0.31 149212 135.96 1.27 0.00 0.00 1.27 88 0.26 149097 135.96 1.27 0.00 0.00 1.27 90 0.22 148976 135.96 1.27 0.00 0.00 1.27 92 0.18 148850 135.96 1.27 0.00 0.00 1.27 94 0.16 148719 135.96 1.27 0.00 0.00 1.27 96 0.13 148586 135.96 1.27 0.00 0.00 1.27 98 0.11 148449 135.95 1.27 0.00 0.00 1.27 100 0.09 148310 135.95 1.27 0.00 0.00 1.27 102 0.08 148169 135.95 1.27 0.00 0.00 1.27 104 0.07 148026 135.95 1.27 0.00 0.00 1.27 106 0.05 147881 135.95 1.27 0.00 0.00 1.27 108 0.05 147736 135.95 1.27 0.00 0.00 1.27 110 0.04 147590 135.94 1.27 0.00 0.00 1.27 112 0.03 147442 135.94 1.27 0.00 0.00 1.27 114 0.03 147294 135.94 1.27 0.00 0.00 1.27 116 0.02 147146 135.94 1.26 0.00 0.00 1.26 118 0.02 146997 135.94 1.26 0.00 0.00 1.26 120 0.02 146847 135.93 1.26 0.00 0.00 1.26 122 0.01 146698 135.93 1.26 0.00 0.00 1.26 124 0.01 146548 135.93 1.26 0.00 0.00 1.26 126 0.01 146398 135.93 1.26 0.00 0.00 1.26 128 0.01 146247 135.93 1.26 0.00 0.00 1.26 130 0.01 146097 135.93 1.26 0.00 0.00 1.26 132 0.01 145947 135.92 1.26 0.00 0.00 1.26 134 0.00 145796 135.92 1.26 0.00 0.00 1.26 136 0.00 145645 135.92 1.26 0.00 0.00 1.26 138 0.00 145495 135.92 1.26 0.00 0.00 1.26 140 0.00 145344 135.92 1.26 0.00 0.00 1.26 STORMWATER RETENTION CALCULATIONS Project: Robeson County DSS Facility By: Sip Date: 2/10/10 (Rev.) Job #: 60-1214 142 0.00 145193 135.91 1.26 0.00 0.00 1.26 144 0.00 145043 135.91 1.26 0.00 0.00 1.26 146 0.00 144892 135.91 1.26 0.00 0.00 1.26 148 0.00 144741 135.91 1.26 0.00 0.00 1.26 150 0.00 144591 135.91 1.26 0.00 0.00 1.26 152 0.00 144440 135.91 1.26 0.00 0.00 1.26 154 0.00 144290 135.90 1.25 0.00 0.00 1.25 156 0.00 144139 135.90 1.25 0.00 0.00 1.25 158 0.00 143989 135.90 1.25 0.00 0.00 1.25 160 0.00 143838 135.90 1.25 0.00 0.00 1.25 162 0.00 143688 135.90 1.25 0.00 0.00 1.25 164 0.00 143538 135.89 1.25 0.00 0.00 1.25 166 0.00 143388 135.89 1.25 0.00 0.00 1.25 168 0.00 143237 135.89 1.25 0.00 0.00 1.25 170 0.00 143087 135.89 1.25 0.00 0.00 1.25 172 0.00 142937 135.89 1.25 0.00 0.00 1.25 174 0.00 142787 135.89 1.25 0.00 0.00 1.25 176 0.00 142637 135.88 1.25 0.00 0.00 1.25 178 0.00 142487 135.88 1.25 0.00 0.00 1.25 180 0.00 142337 135.88 1.25 0.00 0.00 1.25 182 0.00 142188 135.88 1.25 0.00 0.00 1.25 184 0.00 142038 135.88 1.25 0.00 0.00 1.25 186 0.00 141888 135.87 1.25 0.00 0.00 1.25 188 0.00 141739 135.87 1.25 0.00 0.00 1.25 190 0.00 141589 135.87 1.25 0.00 0.00 1.25 192 0.00 141440 135.87 1.25 0.00 0.00 1.25 194 0.00 141290 135.87 1.24 0.00 0.00 1.24 196 0.00 141141 135.87 1.24 0.00 0.00 1.24 198 0.00 140992 135.86 1.24 0.00 0.00 1.24 200 0.00 140842 135.86 1.24 0.00 0.00 1.24 202 0.00 140693 135.86 1.24 0.00 0.00 1.24 204 0.00 140544 135.86 1.24 0.00 0.00 1.24 206 0.00 140395 135.86 1.24 0.00 0.00 1.24 208 0.00 140246 135.85 1.24 0.00 0.00 1.24 210 0.00 140097 135.85 1.24 0.00 0.00 1.24 212 0.00 139948 135.85 1.24 0.00 0.00 1.24 214 0.00 139799 135.85 1.24 0.00 0.00 1.24 216 0.00 139651 135.85 1.24 0.00 0.00 1.24 218 0.00 139502 135.85 1.24 0.00 0.00 1.24 220 0.00 139353 135.84 1.24 0.00 0.00 1.24 222 0.00 139205 135.84 1.24 0.00 0.00 1.24 224 0.00 139056 135.84 1.24 0.00 0.00 1.24 226 0.00 138908 135.84 1.24 0.00 0.00 1.24 228 0.00 138759 135.84 1.24 0.00 0.00 1.24 230 0.00 138611 135.83 1.24 0.00 0.00 1.24 232 0.00 138463 135.83 1.23 0.00 0.00 1.23 234 0.00 138315 135.83 1.23 0.00 0.00 1.23 236 0.00 138167 135.83 1.23 0.00 0.00 1.23 238 0.00 138018 135.83 1.23 0.00 0.00 1.23 240 0.00 137870 135.83 1.23 0.00 0.00 1.23 U.S. Postal Service iM CERTIFIED Off- 8EGEIPT �Domtlellya MIMoilD�oearu_osuriwrebslCov_ewrawg,ueJsrproscwomaeeaf Ce tewZp� rr - - C3 oslopa s 9. 9• D 9 ra ru Codified Fee Postmark un Return Receipt Fee Here C3 (Endorsement Required) O Restricted Callum Fee �OlieSOn (Endorsement Required) o CC CoUn�j/ rn Total Postage 8 Fees $ r9 ru � r I AF.Nr Io. ...r.,�..5...... '.! .-I '--�0...... I .. %'.. LYa r/YllV C GT O i3 J�8 ■ Complete items 7, 2, and 3. Also complete Item 4 if Restricted Delivery is desired. ■ Print your name and address on the reverse so that we can return the card to you. 'Attach this card to the back of the maiipiece, or on the front if space permits. 1. Article Addressed to: C"I)IiiV l`! r)I' 12C:t31 ;,1'tirN' I�'iR Kf:;� \�'INUi.Ea f'L)I!N'1'1' 1I,lii 1(a;R 'It! Ivr )lilli I:I ai S`fRi:i:'"! LU1. )M N(: S.i?R 2. Article Number (77ansfer from servke fabaq PS Form 3811 Febru A SI ture u ❑ Agent M El. Received by (Printed Name Addressee C. Date of Delivery D. Is delivery addrss different from Hem 1 ? ❑Yes If YES, enter delivery address below: ❑ No 3. Se ce Type Certifed Mail ❑ Express Mall ❑ Registered ❑ Retum Receipt for Merchandise ❑ Insured Mail ❑ C.O.D. 4. Restricted Delivery? (Ew, Fee) ❑ Yes 7006 2150 0005 2109 8419 ary 4." Domestic Return Receipt 102595-02-M-1590 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverlv Eaves Perdue Coleen H. Sullins Governor Director September 8, 2009 CERTIFIED MAIL: 7006 2150 0005 2109 8419 RETURN RECEIPT REQUESTED County of Robeson Attn: Ken Windley, County Manager 701 North Elm Street Lumberton, NC 28358 SUBJECT: Post -Construction Stormwater Notification (HQW/ORW) Robeson County DSS Facility Robeson County Dear Mr. Windley: Dee Freeman Secret=ry Our office has received a copy of the Financial Responsibility/Ownership Form (FR/O) from the Division of Land Resources, Land Quality Section for the Robeson County DSS Facility project to be located in Robeson County. Based on project location information provided on the FR/O, we have determined that the project is subject to a State Stormwater Management Permit for development activities within one mile of and draining to High Quality Waters (HOW). Please be advised that construction of any built -upon areas prior to issuance of a State Stormwater Management Permit will be considered a violation of the NC Administrative Codes and could result in the assessment of civil penalties of up to $25,000 per day, per violation. The State Stormwater Management Permit is in addition to the NPDES Stormwater General Permit (NCG010000) received for construction activities. For more information and to obtain the application and applicable supplement forms, please visit: http://www.ncwaterquality.org/su/state_sw.htm. If you have any questions concerning this matter, please contact me at (910) 433-3329. Sincerely, Michael Lawyer Environmental Specialist Enclosure cc: Robeson County Zoning & Planning Department, PO Box 1284, Lumberton, NC 28359 FRO -Surface Water Protection FRO -Land Quality Location: 225 Green Street. Suite 714, Fayetteville, North Carolina 28301 i''unne. 910-433-33001 FAX: 910-486-07071 Customer Service: 1-877-623-6748 'nternet mvv.ncvraterguality.org One NOrTl iCaroj l ntt Alatlllwlly An NUN O,lporhimd , Anhma[IV n Action Employer FINANCIAL RESPONSIBILITY/OWNERSHIP FORM SEDIMENTATION POLLUTION CONTROL ACT No person may initiate any land -disturbing activity on one or more acres as covered by the Act before_this"-: -- form and an acceptable erosion and sedimentation control plan have been completed and approved by the Land Quality Section, N.C. Department of Environment and Natural Resources. (Please type or print and, if the question is not applicable or the e-mail and/or fax information unavailable, place N/A in the blank.) Part A. q 1. Project Name Robeson County DSS Facility Vo 2. Location of land -disturbing activity: County Robeson City or Township Lumberton Highway/Street SR 1547 (Glen Cowan Road) Latitude 34.628690 N Longitude 79.06444° W 3. Approximate date land -disturbing activity will commence: January 2010 4. Purpose of development (residential, commercial, industrial, institutional, etc.): Commercial 5. Total acreage disturbed or uncovered (including off -site borrow and waste areas): 30.0 Acres 6. Amount of fee enclosed: $ 1950.00 The application fee of $65.00 per acre (rounded up to the next acre) is assessed without a ceiling amount (Example: a 9-acre application fee is $585). s 'p cc=. 7. Has an erosion and sediment control plan been filed? Yes No Enclosed X 8. Person to contact should erosion and sediment control issues arise during land -disturbing activity: Name Sam Isham E-mail Address sam.isham aa)metconconstruction.net Telephone 910.521.8013 Cell # 910.374.5620 Fax # 910.521-8014 9. Landowner(s) of Record (attach accompanied page to list additional owners): County of Robeson 910.671.3022 910.671.3010 Name Telephone Fax Number 701 North Elm Street 701 North Elm Street Current Mailing Address Current Street Address Lumberton NC 28358 Lumberton NC 28358 City State Zip City State Zip 10. Deed Book No. 1699 Page No. 447 - 450 Provide a copy of the most current deed. Part B. Person(s) or firm(s) who are financially responsible for the land -disturbing activity (Provide a comprehensive list of all responsible parties on an attached sheet): Countv of Robeson Name 701 North Elm Street Current Mailing Address Lumberton NC 28358 City State Zip Telephone 910.671.3022 ken.windlev aaco.robeson.nc.us E-mail Address 701 North Elm Street Current Street Address Lumberton NC 28358 City State Zip Fax Number 910.671.3010 2. (a) If the Financially Responsible Party is not a resident of North Carolina, give name and street address of the designated North Carolina Agent: Name E-mail Address Current Mailing Address Current Street Address fl City State `. Zip. City State Telephone Fax Number (b) If the Financially Responsible Party is a Partnership or other person engaging in business under an assumed name, attach a copy of the Certificate of Assumed Name. If the Financially Responsible Party is a Corporation, give name and street address of the Registered Agent: of Registered Agent E-mail Current Mailing Address Current Street City Slate Zip City State Telephone Fax Number The above information is true and correct to the best of my knowledge and belief and was provided by me under oath (This form must be signed by the Financially Responsible Person if an individual or his attorney -in -fact, or if not an individual, by an officer, director, partner, or registered agent with the authority to execute instruments for the Financially Responsible Person). I agree to provide corrected information should there be any change in the information provided herein. Ken Windley County Manager Type or print name Title or Authority 7- 3 (--09 Signature Q Date I, L I j'a' t I l` AM(% , //a Notary Public of the County of gr�� wz�_= State of North Carolina, hereby certify that appeared personally before me this day and being duly sworn acknowledge that the above form was executed by Witness r"nd and notYfi31 seal, this 3_Lday of 200 1 i pTAt3Y ; s P PUB\-\G a' 402aarny�� O ,+ r, AFC �� • My commission expires 1 1a a, o�Qt 3 i I � t I• Iv qq I as _\r`//111 0 } ` '. ill.:- � rhh . - \ \ \ - i'-•+-.�-Iay! �` sr;`' � �3. -w• - x� '� .. µ., \+ Water Ta 11 sue\ sf �y �`! - ♦� 7-131 s `' ,fir a�a hs s� .�•/ C •.I y- ' ?95Ji JUL gjV$S �� :aA;s vw� YF inaustal Wd$tn Pond McH wn CA J' a .; ..`ram ®9.,• _I,\ j LUMHERTON Cem -p- bt9 '� �\ MUNICIPAL'/AIRPORT �� + \ ( \ I f,oilI f % �