Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW6090701_NOV_20110816
NC®ENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor CERTIFIED MAIL: 7009 0820 0000 2473 8305 RETURN RECEIPT REQUESTED Cumberland County Schools Attn: Wilson Lacy 2465 Gillespie Street Fayetteville, NC 28306 Division of Water Quality Coleen H. Sullins Director August 16, 2011 Subject: NOTICE OF VIOLATION (NOV-201 1 -PC-0461) State Stormwater Management Permit SW6090701 Grays Creek Middle School Cumberland County Dear Mr. Lacy: Dee Freeman Secretary On August 9, 2011, I, Michael Lawyer from the Fayetteville Regional Office of the Division of Water Quality, along with Robert Patterson and Brian Lowther with the Stormwater Permitting Unit, conducted a Compliance Evaluation Inspection at the Grays Creek Middle School facility located in Cumberland County, North Carolina. The purpose of the inspection was to ensure compliance with State Stormwater Management Permit SW6090701 that was issued on July 8, 2009. A copy of the Compliance Inspection Report is enclosed for your review. As a result of the inspection and subsequent file review, it has been determined that the facility is Not Compliant. The required actions that are necessary to bring this site into compliance are noted under the Inspection Summary and Comments sections of the report. You are asked to provide this office a written/typed response within 30 calendar days from receipt of this letter. Your response should specify actions that will be undertaken and the time frame that will be required to correct the deficiencies. Failure to properly resolve the violation(s) may constitute the assessment of a civil penalty of up to $25,000 per day, per violation. If you have any questions or this office can be of any assistance, please contact me at (910) 433-3329 or by e-mail at mike.lawyer@ncdenr.gov Sincerely, Belinda S. Henson Regional Supervisor Surface Water Protection Section BSH: ML/ml cc: David Kiker, PE-W.K. Dickson & Co., Inc., 3101 John Humphries Wynd, Raleigh, NC 27612 Stormwater Permitting Unit FRO -Surface Water Protection Location: 225 Green Street, Suite 714, Fayetteville: North Carolina 28301 Phone, 910-433-33001 FAX: 910-086-07071 Customer Service: 1-877-623-6748 Internet: http://ponatncdenr.orglweb/wq An Ep0e1 Opportunity l ANnrative Aeon Employer One NorthCarolina Naturally U.S. Postal Service.., CERTIFIED MAILTtr RECEIPT (Domestic Mail Only; No Insurance Coverage Provided) For delivery Information visit our website at www.usps.como fTl Ii..-. a r,• .r. w:v, u—uv-- wr o7v M1 S Postage $ ru Denllled Fee O O Return Reoe4A Fee Postmark p (Endomement Requimd) Hem O Restrbled Delivery Fee (Endomement Required) O ru M Totel Po9lepe 8 Fees O PS Form 9600, Aueu.t 2006 • See Revers. for Instructions Compliance Inspection Report Permit: SVV6090701 Effective: 07/08/09 Expiration: 07/07/19 Owner: Cumberland County Board of Education Project: Grays Creek Middle School County: Cumberland Celebration Dr Region: Fayetteville Hope Mills NC 28348 Contact Person: Tim Kinlaw Title: Associate Superintendent Phone: 910-678-2305 Directions to Project: Type of Project: State Stormwater - HD - Detention Pond Drain Areas: On -Site Representative(s): Related Permits: Inspection Date: 08/0912011 Entry Time: 01:10 PM Exit Time: 0145 PM Primary Inspector: Mike Lawyer je� G� Phone: 910-433-3300 Secondary Inspector(s): E 33Z`I Robert D Patterson����� Phone: rrfiwti+rr Belinda S Henson N� Phone: 910-433-3300 Exy7-26 Brian Lowther Phone: .33ZC,, Reason for Inspection: Routine Permit Inspection Type: State Stormwater Facility Status: f3 Compliant ■ Not Compliant Question Areas: ■ State Stormwater (See attachment summary) Inspection Type: Compliance Evaluation Page: 1 Permit: SW6090701 Owner- Project: Cumberland County Board of Education Inspection Date: 08/09/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted to ensure compliance with Stormwater Management Permit and associated plans. Erosion observed in areas around inlets and along slopes. Re -vegetation needed. Additional inlet pipe entering main pond that was not on the approved plans and head -cutting has occurred under the pipe. Flow should be redirected to the forebay and revised plans submitted for review and approval. Outlet structure does not meet approved design and configuration. Two cut-outs were observed within the riser barrel that are lower than shown on the approved plans. This is not allowing for temporary storage and should be fixed to meet approved design specs. Page:2 Permit: SW6090701 Owner - Project: Cumberland County Board of Education Inspection Date: 08/09/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine File Review Yes No NA NE Is the permit active? - Signed copy of the Engineer's certification is in the file? Signed copy of the Operation & Maintenance Agreement is in the file? Copy of the recorded deed restrictions is in the file? Comment: Built Upon Area Is the site BUA constructed as per the permit and approval plans? Is the drainage area as per the permit and approved plans? Is the BUA (as permitted) graded such that the runoff drains to the system? Comment: SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: Additional inlet pipe observed going directly into main pond. Outlet structure has two cut-outs in riser barrel, which are lower than what is shown on the approved plans and reducing temporary storage. Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? Yes No NA NE ■nnn ■ ❑ ❑ ❑ ■nnn Yes No NA NE n■nn n■nn ■nnn Yes Nn NA NF Are the SW BMP inspection and maintenance records complete and available for review or provided to DWO ❑ ❑ ❑ ■ upon request? Comment: Erosion observed along slopes and around rip -rap at inlets. Head -cutting below and underneath flared -end section of additional inlet pipe going into main pond. Re -vegetation needed in some areas including establishment of appropriate plantings along vegetative shelf. Other Permit Conditions Yes No NA NE Is the site compliant with other conditions of the permit? ■ ❑ ❑ ❑ Comment: Other WQ Issues. Yes No NA NE Is the site compliant with other water quality issues as noted during the inspection? ■ n ❑ n Comment: No obvious water quality impacts observed at the time of inspection. Page: 3 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES FAt'p �'Q'� NCDENR 225 GREEN STREET - SUITE 714 O 'goes FAYETTEVILLE, NC 28301-5043 [�j� � �j PiNCY BOWpF:Sp ©Y®II �;b�—��® 02 1M � (Do -440 0004258230 AUG17 2011 rMAILED FROM ZIPCODE 28301 cc w ®'> O RECEIVE. DAVID KIKER, PE-W.K. DICKSON & CO., INC. iA2 4 2011 3101 JOHN h RALEIGH, NC NIXIE �N2 7sE�1•seEiEGI0NAL0FPoo oai22i11 �ERETURN TO SENDER NOT DELIVERABLE AS ADDRESSED UNABLE TO FORWARD DC: 20301SO4.599 �20S4-17105-10-3S 2L-7F % 2L� ls'nsmlca.so4s L161L11,1111JI 1I11I1,111,111,,,L LI,LLL,LI„1L,11 \ Pn. -ten... \\ .. / ` � 1'. ail �1 i1,� � i � � � NC®ENR North Carolina. Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue - Coleen H. Sullins Governor - Director August 16, 2011 CERTIFIED MAIL: 7009 0820 0000 2473 8305 RETURN RECEIPT REQUESTED Cumberland County Schools Attn: Wilson Lacy 2465 Gillespie Street Fayetteville, NC 28306 Subject: NOTICE OF VIOLATION (NOV-2011-PC-0461) State Stormwater Management Permit SW6090701 Grays Creek Middle School Cumberland County Dear Mr. Lacy: Dee'Freeman Secretary On August 9, 2011, I, Michael Lawyer from the Fayetteville Regional Office of the Division of Water Quality, along with Robert Patterson and Brian Lowther with the Stormwater Permitting Unit, conducted a Compliance Evaluation Inspection at the Grays Creek Middle School facility located in Cumberland County, North Carolina. The purpose of the inspection was to ensure compliance with State Stormwater Management Permit SW6090701 that was issued on July'8, 2009. A copy of the Compliance Inspection Report is enclosed for your review. As a result of the inspection and subsequent file review, it has been determined that the facility is Not Compliant. The required actions that are necessary to bring this site into compliance are noted under the Inspection Summary and Comments sections of the report. You are asked to provide this office a written/typed response within 30 calendar days from receipt of this letter. Your response should specify actions that will be undertaken and the time frame that will be required to correct the deficiencies. Failure to properly resolve the violation(s) may constitute the assessment of a civil penalty of up to $25,000 per day, per violation. If you have any questions or this office can be of any assistance, please contact me at (910) 433-3329 or by e-mail at mike.lawyer@ncdenr.gov Sincerely, Belinda S. Henson Regional Supervisor Surface Water Protection Section BSH: ML/ml cc: David Kiker, PE-W.K. Dickson & Co., Inc., Stormwater Permitting Unit FRO -Surface Water Protection Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301 Phone: 910-433-33001 FAX: 91 DA86-07071 Customer Service: 1-877-623-6748 Internet: httpJ1ponal.nodenr.orglweb1wq An Equal Opponumly� Aflumabre Action Employer One NorthCarolina Naturally Compliance Inspection Report Permit: SVV6090701 County: Cumberland Region: Fayetteville Effective: 07/08/09 Expiration: 07/07/19 Owner: Cumberland County Board of Education Project: Grays Creek Middle School Celebration Dr Contact Person: Tim Kinlaw Directions to Project: Hope Mills NC 28348 Title: Associate Superintendent Phone: 910-678-2305 Type of Project: State Stormwater - HD - Detention Pond Drain Areas: On -Site Representative(s): Related Permits: Inspection Date: 08/09/2011 Entry Time: 011::10 PM Exit Time: 01:45 PM Primary Inspector: Mike Lawyer��/�G--tom G� Secondary Inspector(s): Robert D Patterson �rr�w'Gr. Belinda S Henson Brian Lowther Reason for Inspection: Routine Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ■ Not Compliant Question Areas: E State Stormwater (See attachment summary) Phone: 910-433-3300 E57,29" Phone: Phone: 910-433-3300 Exy7.26 Phone: 332rp Inspection Type: Compliance Evaluation Page: 1 Permit: SW6090701 Owner - Project: Cumberland County Board of Education Inspection Date: 08/09/2011 Inspection Type: Compliance Evaluation _ Reason for Visit: Routine Inspection summary: % Inspection conducted to ensure compliance with Stormwater Management Permit and associated plans. Erosion observed in areas around inlets and along slopes. Re -vegetation needed. Additional inlet pipe entering main pond that was not on the approved plans and head -cutting has occurred under the pipe. Flow shouldbe redirected to the forebay and revised plans submitted for review and approval. Outlet structure does not meet approved design and configuration. Two cut-outs were observed within the riser barrel that are lower than shown on the approved plans. This is not allowing for temporary storage and should be fixed to meet approved design specs. r 41 Page:2 J Permit: SVV6090701 Owner- Project: Cumberland County Board of Education Inspection Date: 08/09/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine File Review Yes. No NA .NE' Is the permltactrve?'w _. .r • . . ,. -� fl �',�- .,. Signed copy of theEngineer's certification is in the file? • - �� -" "' "' - " ' � ❑' ❑ ❑ Signed copy of the Operation & Maintenance Agreement is in the file? Copy of the recorded deed restrictions is in the file? Comment: Built Upon Area Is the site BUA constructed as per the permit and approval plans? Is the drainage area as per the permit and approved plans? Is the BUA (as permitted) graded such that the runoff drains to the system? Comment: SW Measures Are the SW measures constructed as per the approved plans? - Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: Additional inlet pipe observed going directly into main pond. Outlet structure has two cut-outs in riser barrel, which are lower than what is shown on the approved plans and reducing temporary storage. Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? ■ ❑ 0 0 ❑❑■❑ Yes No NA NE ■❑❑❑ ■ ❑ ❑ ❑ ■❑❑❑ Yes No NA NE ❑■❑❑ ❑■❑❑ e❑❑❑ Yes No NA NE ❑ ■ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ ❑ 0 ❑ ■ upon request? Comment: Erosion observed along slopes and around rip -rap at inlets. Head -cutting below and underneath flared -end section of additional inlet pipe going into main pond. Re -vegetation needed in some areas including establishment of appropriate plantings along vegetative shelf. Other Permit Conditions Yes No NA NE Is the site compliant with other conditions of the permit? ■ ❑ ❑ ❑ Comment: Other WQ Issues Yes No NA NE Is the site compliant with other water quality issues as noted during the inspection? ■ ❑ ❑ ❑ Comment: No obvious water quality impacts observed at the time of inspection. Page: 3 i L,, ®I I tIMIT OF WORK •I, I MA-MT-M EMEROEN 8INLLBE BEEDEp ANp MIILCFIEp 1 r SEEM CN NFE1B 36�)M3&4 e 111 � ° RElk 6. ST BEEM)jA EA: D mw ° ,4, 1.12 AC i Mpg ; �� l`i .!°i l_.l ii_ :.cI wf 1- I-" / i _ All N. NAAA ,�, — A 2DAREA:5; ZEA 2B fST ED AREA DISTURB AREA i RBED AREA _ i :4� W, C .AC 72 AG o ° ='.M A ' m rmao ° s 0.50' ABOVE NORMAL POOL ELEV NORMAL POOL ELEV, =157.9 ,•.•.•. 0°o°0°0"o"o"o"o"o"o"o" o" CLASSIRIP RAP 0 0 0 0 0 0 0 0 0 0 0 0 00000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 000000000000000000000000000 o°o°o°o°o°o°0°0°0°0°0°0°0 o°o°o°o°o°o°o°o°o°o°oo oOT. ELEV.= 153.00 �M J °p°p°p°a ,L) o000000 LADE 2-0 SECTION N.T.S TOP ELEV. 6" ABOVE NORMAL POOL 0-0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000000000000000000000000000 0°0°0°0°-°^O,°n°o°o°o°o°o°0°0°0°0°0 0°o � 0„000„0„0_0 ELEVATION FOREBAY BAFFLE N.T.S. LEGEND WET POND PLANTS QTY. 68 Q PICKEREL WEED - (SPACING I' O/C) QTY. 58 G MARSH MALLOW . (SPACING I' O/C) QTY. 62 ® SOFTSTEM BULRUSH - (SPACING 2' O/C) WELDED TO CMP RISER EL. 160.78 - 25-YR 24 HOUR STORAGE ELEVATION - TOP OF OUTLET BOX EL. 159.99 - 10-YR 24 HOUR STORAGE ELEVATION - - - - - - - - - - - - - - - - - - - - - - - - - EL. 159.29 - 5-YR 24 HOUR STORAGE ELEVATION - - - - - - - - - - - - - - - - - - - - - - - - - EL. 18.27 1-YR 24 HOUR STORAGE ELEVATION (3) 12" W x 301 RECTANGULAR OPENING- INV. = 158.07 OPENING EL. I58.07 W.Q. TEMP STORAGE ELEVATION ___1 ------------------------------ 4" DIA. OPENING- INV. = 157.00 OPENING EL. 157.00 PERMANENT POND EL. 157.00 ------------------ POND BOTTOM EL. 153.00 BOTTOM OF RISER PIPE -TOP OF RISER EL 160.50 STEPS /-54" EXISTING CONCRETE DESIGNED AND INSTA CONTRACTOR