HomeMy WebLinkAboutSW3170701_APPROVED PLANS_20170829STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW 517z% 7d DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑. COMPLIANCE EVALUATION INSPECTION DOC DATE�17Q��� YYYYMMDD PROJECT INFORMATION ENGINEERED KELLY HEFNER 714 115 9'43 MANAGER: KELLY HEFNER@ADS-PIPECOM KEITH COEN ADS SALES REP: 704466-0135 KEITH. COEN @ADS -PIPE COM PROJECT NO: IY7632 ADVANCED DRAINAGE SYSTEMS, INC. SMG PROPERTIES STATESVILLE, NC STORMWATER CHAMBER SPECIFICATIONS IMPORTANT - NOTES FOR THE BIDDING AND INSTALLATION OF THE SC-3101SC-740 SYSTEM 1. CHAMBERS SHALL BE STORMTECH SC-740. SC-310, OR APPROVED EQUAL. 1. STORMTECH SC 310 & SC-740 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A PRE -CONSTRUCTION MEETING WITH THE INS I ALLERS. 2, CHAMBERS SHALL BE MANUFACTURED FROM VIRGIN POLYPROPYLENE OR POLYETHYLENE RESINS. 2, STOFU,iTECH SC-310 & SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE'STORMTECH SC-3101SG740/SC-789 CONSTRUCTION 3. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT PANELS THAT GUIDE". WOULD IMPEDE FLOW OR Uh11T ACCESS FOR INSPECTION. 3, CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR AN EXCAVATOR SITUATED OVER THE CHAMBERS. 4. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE STORMTECH RECOMMENDS 3 BACKFILL METHODS: THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO _RFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: t) STONESHOOTER LOCATED OFF THE CHAMBER BED. LONG -DURATION DEAD LOADS AND 2) SHORT -DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION ' BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE. FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. ' BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR. 5. CHAMBERS SHALL MEET ASTM F2922 (POLYETHYLENE) OR ASTM F2418-16 (POLYPROPYLENE). "STANDARD SPECIFICATION FOR 4. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS. THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 5. JOINTS BETWEENCHAMBERS PROPERLYSEATED PRIOR TO PLACING STONE, 6 .,NA i8ER5 SHALL BE DE_.CNE., AND LOADS _ # R PR DESIGNED m . 6: S DETERMINED D ! WITH hST C99 PRACTICE O E _.. NINE_.NACCORD W.TO .M. T ACCORDANCE _.87 S ANDA..D..A. CE C F OR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". C _ 6. iNAiNTAiiJ MINIMUM-6" ISO mm SPACING BETWEEN THE CHAMBER ROW-. ( ) J 7. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. THE CHAMBER MANUFACTURER SHALL 7. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE 314-2' 120-50 mm) SUBMIT THE FOLLOWING UPON REQUEST TO THE SITE DESIGN ENGINEER FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE: 8. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE SITE DESIGN ENGINEER. a. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1,95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM ADSR RECOMMENDS g ADS RECOMMENDS THE USE OF'FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE SUBSURFACE F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE. MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF. 8. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE LOAD NOTES FOR CONSTRUCTION EQUIPMENT FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET. THE 50 YEAR CREEP MODULUS DATA SPECIFIED IN ASTM F2418 OR ASTM F2922 MUST BE USED AS PART OF THE AASHTO STRUCTURAL EVALUATION 1. STORMTECH SC-310 & SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-3101SC-7401DC-780 CONSTRUCTION TO VERIFY LONG-TERM PERFORMANCE. GUIDE". c. STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL EVALUATION IS BASED. 2. THE USE OF CONSTRUCTION EQUIPMENT OVER SC-310 & SC-740 CHAMBERS IS LIMITED: NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS. S. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY. NO RUBBER TIRED LOADERS, DUMP TRUCKS, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH SC-3101SC-740/DC-780 CONSTRUCTION GUIDE". • WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH SC-3101SC-740/DC-780 CONSTRUCTION GUIDE". 3. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING. USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO THE CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY THE "DUMP AND PUSH- METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY. AIR P CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT ABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS AASHTO MATERIAL COMPACTION / DENSITY MATERIAL LOCATION DESCRIPTION CLASSIFICATIONS REQUIREMENT Q FINAL FILL: FILL MATERIAL FOR LAYERED' STARTS 'FRONT THE TOP OF THE C LAYER TO THE BOTTOM ANY SORJROCK »ATERiALS. NATIVE SOILS. OR PER PREPARE PER SITE DESIGN ENGINEERS PLANS. D OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED ENGINEER'S PLANS. CHECK P FOR PAVEMENT C K PLANS O N/A PAVED INSTALLATIONS MAY HAVE STRINGENT GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE SUBGRADE REQUIREMENTS. MATERIAL AND PREPARATION REQUIREMENTS. MAY BE PART OF THE'D' LAYER BEGIN COMPACTIONS AFTER 12" (300 mm) OF AASHTO M145' MATERIAL OVER THE CHAMBERS IS REACHED. INITIAL FILL FILL MATERIAL FOR LAYER'C' GRANULAR WELL -GRADED SOIL/AGGREGATE MIXTURES <35°'o A-2-4 A-1, , A-3 COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX STARTS FROM THE TOP OF THE EMBEDMENT FINES OR PROCESSED AGGREGATE. LIFTS TO A MIN. 95%PROCTOR DENSITY FOR C STONE ('8' LAYER) TO 18" (450 mm) ABOVE THE OR WELL GRADED MATERIAL AND 95% RELATIVE TOP OF THE CHAMBER. NOTE THAT PAVEMENT MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU AASHTO M DENSITY FOR PROCESSED AGGREGATE SUBBASE MAY BE A PART OF THE'C' LAYER. OF THIS LAYER. 3, 357. 4. 467, 5, 56, 57, 6, 67,7, 68, 7, 78, 8, 89, MATERIALS. ROLLER GROSS VEHICLE WEIGHT 9, 10 NOT TO EXCEED 12,000 Ibs (53 IIN. DYNAMIC FORCE NOT TO EXCEED 20,0001Us (89 kN). EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS r FOUNDATION STONE(A CLtgN .:RvHFD A.,ULRSTONE AASH?D M43` NO CC �ES;CTION REQUIREL'. L0.YER) TO THE'C'LAYER ABOVE C' LAY 3.357,4,467,5,56, 57 EA FOUNDATION STONE: FILL BELOW CHAMBERSAASHTO TO M43' PLATE COMPACT OR ROLL TO ACHIEVE A FLAT FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) CLEAN, CRUSHED, ANGULAR STONE 3, 357, 4, 5, 56, 57 SURFACE - PLEASE PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY, THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: 'CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FORA' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE ALL AROUND CLEAN CRUSHED ANGULAR STONE IN A & B LAYERS PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) AL PERIMETER STONE D / 'rCUTCM OFFLEXIBLE PAVEMENT . FcZ UNPAVED 8' (BEE NOTE 6) INTPL ONY WHERE RUTTING ROM VEH LE5 MAY CENE 18,• 1 G. \ rtIRF0.,= c011H N,G, r,Y.rm, 12.4 m) (450 mm) Ni MAX 6" (150 mm) MIN EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) si';3 i I I'�i "' ® e ( l; I J760 Ruin) 1 n Syr , NV i ad xa ' A) �L DEPTH OF STONE TO BE DETERMINED SC-740 6" 8Y SITE DESIGN ENGINEER G" (150 mm) MIN 12" (300 ni MIN END CAP SUBGRADE SOILS (150 m) MIN 51" (1295 in 12' (300 mm) TYP NOTES: SEE NOTE 4, 1. SC-740 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 *STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS-. OR ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2. SO-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3. "ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT. AND FILL MATERIALS. 4. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 5, PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 6, ONCE LAYER'C' IS PLACED, ANY SOILIMATERIAL CAN BE PLACED IN LAYERED' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER'C' OR'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. � x J - LL= U' W C) )- Z LU J W LU Z tt o w T C, J G• /0- V Z N 0) ] W p w �� wo z8 R 'O rwip wu �o 3 <H °a - e m Ii - �e ° E $ y w h ac O� or N hi fD� O_w Q z wO aN Ef p °F J ei sEz - m� Ao o a'6 3 SHEET 6 of PROPOSED LAYOUT 60 STORMTECH SC-740 CHAMBERS NOTES MANIFOLD SIZE TO BEDETERMINED Y B SITE DESIG N ENGINEER. SEE TEC H SHEET #7 FOR MANIFOLD 10 STORMTECH SG740 END GAPSOLD SIZING GUIDANCE. 6 STONE ABOVE (in) DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAYBE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLD COMPONENTS IN THE FIELD. 8 STONE rarLOW' ('m, _. - RING & COVER 49 %STONERI)( ELEy. - 878.50� 5181 INSTALLEDD SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED) 2,519 SYSTEM AREA Ft') 246 SYSTEM PERIMETER (ft) PROPOSED ELEVATIONS 6' DIA PRECAST CONCRETE CONE MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED): B80.24 - 6' DIA PRECAST MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC): 874.24 - : CATCH BASIN MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC): 873.74 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT): 873.74 _ /\ MINIMUM ALLOWABLE GRACE (TOP OF RIGID PAVEMENT): 873.74 vau TOP OF STONE 872.74 .. ., =.r _��.�.�.� .-i'"-�.�^,-..'�[u ��\a TOP OF SC-740 CHAMBER: _ 872,24 6 °IA PRECAST CONCRETE ' , w aw G rs. CATCH BASIN - 12" BOi. CON. 12 TOP MANIFOLD INVERT 870.78 INV, 869,84 12" BOTTOM CONNECTION INVERT 869,84 - 6" BAFFLE WALL CONCRETE BA 24" ISOLATOR ROW INVERT 869,75 CON ( SEE ONCIRET TBA SHEfT BOTTOM OF SC 740 CHAMBER. 869.74 BOTTOM OF STONE: 86924 FLO O - 12" ADS N-12 - INV IN - 869,74 �. -. =Pl FLO r SLOPE BOTTOM W/ GROUT -- - 18' RCP Jr /�� 'N�v9OUT +-�.J-i-� t0 SECTION THROUGH BAFFLE WALL vlIT.LET COrI T Q()! STRv ?-.I IQF NOT TO SCALE 1, I,V II�VL .� II\ 97,46' 87.01' 24" PREFABRICATED END CAP, PART# SC740EPE24B n PROPOSED 30" NYLOPLAST TYP OF ALL SC-740 24' CONNECTIONS AND ISOLATOR V PROPOSED 30" NYLOPLAST MAXIMUM INLET FLOW 4.2 MAXIMUM INLET FLOW 6.2 CPS (24" SUMP MIN)IN) ROWS INSPECTION PORT 1 (24' SUM MIN) FROM J6-10 _ MY = 872.74 - ISOLATOR ROW �yg. FROM JB-11 INV = 87P.74 PIS � i I INVERT 12.5" AB .,-. _. 12 X 12 ADS N i2 TOP MAMANIFOLD, , 12' X i, ADS N-12 TOP MANIFOLD i� V '\ � - O E CHAMBER BASE � r I INVERT 12.5"ABOVE CHAMBER BASE N � (SEE NOTES) N _ � (SEE NOTES} N 12" ADS N-12 BOTTOM CONNECTION I INVERT 1.2" ABOVE CHAMBER BASE (SEE NOTES) ' PROPOSED OUTLET CONTROL STRUCTURE MAXIMUM OUTLET FLOW 4A ORB ^ SEE DETAIL ABOVE l _3\ 1 V PLACE MINIMUM 12.S OF. ADS GEOSYNTHFTICS 315W'TK WOVEN GEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS COVER ENTIRE ISOLATOR ROW WITH ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE 8'(2.4 m) MIN WIDE s- SC-740 CHAMBER STORMTECH HIGHLY RECOMMENDS FLEXSTORM PURE INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATESY., r ry CATCH BASIN II+14 OR I MANHOLE I aa, E I41 1� I I I Ahm I "I, I I SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24' (E00 mml MIN RECOMMENDED) I- (600 HOPE ACCESS PIPE REQUIRED USE FACTORY RY PRE -FABRICATED END CAP --- --"--- -. PART #: SC740EPE24B SMG PROPERTIES SC-740 ISOLATOR ROW DETAIL NITS INSPECTION & MAINTENANCE STEP 1) INSPECT ISOLATOR ROW FOR SEDIMENT A. INSPECTION PORTS (IF PRESENT) ESENT) A. 1, REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED A.3. USING AFLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.A. LOWER,1 CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDINENT IS AT OR ABOVE 3" 80 mm PROCEED T STEP ( } OCE D O S E 2 IF NOT, PROCEED TO STEP 3, 8. ALL ISOLATOR ROWS C 6.7. REMOVE AVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW B.Z. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY it) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3. IF SEDINENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2, IF NOT, PROCEED TO STEP 3, STEP 2) CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS A. A FIXED CULJERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45' (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS, RECORD OBSERVATIONS AND ACTIONS. STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTES 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. W ' AELL io n H Z Z z Y W J Q W Q > a U Wn AU CL H AU C C N G Cn Fn a cR F A 8 U e -'a �/+� _w G� 3 Ova o S O 8 Eo G o' b a� mo Z v Q x w0 0 tY F E U.o. _ o "- vx N 4 ao SHEET OF v (. ..T� < W 4 WZ ~ Z z r INSPECTION PORT UJ ? U W J < r J I" JJ� O G o c CL n �Jl -OLLIJ 7N c N g In o V) u r i- SC-740 END CAP w r w o a x 3 o III - IL N 0 6 O° r O wO wE y RE TWO LAYERS OF ADS GEOSYNTHETICS 315WTK WOVEN >f GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS BITS m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS o - CONCRETE COLLAF PAVEMENT CONCRETE SLAB 8' (200 mm) MIN THICKNESS FLEXSTORM CATCH II PART# 6212NYF) WITH USE OF OPEN GRATE 6" (150 mm) INSERTA TEE PART# 6P26FBSTIP' INSERTA TEE TO BE CENTEREC ON CORRUGATION CREST ij�G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NO 28625-8506 PHONE 704.872.2411 FAx 704.872.8281 EMAIL Lwild@glwilson.com Commercial and Industrial Construction Since 1945 `\\\1 \IIIIIIII" CA oRPORq JQ%OFE s C, TF = a = F 0267 0 " - SEAL 17365 - i GHQ 1996 \�' �on,.a• Tti CARC '',, MARK nn„' 'lll/III IIIU\\\\ 8/21 /17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT2017 ISSUED DATE : 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 F? v a NORM WATER Np P A-` �� V DETAILS 20 0 10 20 40 60 Y� V �g o5x a3 > �I - z m s TH CONCRETE COLLAR NOT REQUIRED ° 48 FOR UNPAVED APPLICATIONS12" g % s i ° (300 mm) NYLOPLAST INLINE E a DR DRAIN BODY W(SOLID HINGED COVER OR GRATE PART# 27.2AGe1P` 4 S ' S H COVER: "99CGC• - GRATE: 1299CGS E A 6" (150 mm) SDR35 PIPE o 'RE N M1Y mFU o� o - Q x i Ed SC-740 CHAMBER Fit! G c of THE PART# 2712AG61PKIT CAN BE USED TO ORDER ALL NECESSARY COMPONENTS FOR A SOLID LID SE INSPECTION PORT INSTALLATION a ° A In SC-740 6" INSPECTION PORT DETAIL NITS SHEET 4 OF 6 C401 , I y 0 1 4 I I CB - CATCH BASIN CMP - CORRUGATED METAL PIPE CO - CLEAN OUT DB - DEED BOOK DI - DROP INLET ECM - EXISTING CONCRETE MONUMENT EIP - EXISTING IRON PIPE EIR - EXISTING IRON ROD EN - EXISTING NAIL EOG - EDGE OF GRAVEL EOP - EDGE OF PAVEMENT FH - FIRE HYDRANT FP - FLAG POLE FV - FIRE VALVE GM -GAS METER GV - GAS VALVE GW - GUY WIRE HDPE SMOOTH BORE HIGH DENSITY POLYETHYLENE PIPE HVAC - HEATING/COOLING UNIT LPST - LAMP POST (M)-MEASURED NCGS - NORTH CAROLINA GEODETIC SURVEY PBX - POWER BOX PM -POWER METER POB - POINT OF BEGINNING PP -POWER POLE (R) - RECORDED R/W • RIGHT-OF-WAY RCP- REINFORCED CONCRETE PIPE SDMH - STORM DRAIN MANHOLE SSMH - SANITARY SEWER MANHOLE SQ.FT. - SQUARE FEET W V - WATER VALVE LINE: PROPERTY LINE PROPERTY LINE (NOT SURVEYED) EASEMENT SETBACK WATER LINE SANITARY SEWER PIPE STORM DRAIN PIPE FENCE TREE LINE W SS — PROJECT REVISIONS PROJECT TEAM MEMBERS G.L. WILSON BUILDING COMPANY General Contractor & Building Design 190 Wilson Park Road Statesville, North Carolina 28E25 Tel.: (704) 872-2411 Email: mtort@glwilson.com SMG LEASING, LLC Owner 208 Old Mocksville Rd Statesville, North Carolina 28625 Tel.: (704) 924-4283 Email: Lorraine.Lambert@piedmonthea:hcore.com W SS A PROPOSED MEDICAL OFFICE FOR SMG LEASING, LLC REV DATE BY DESCRIPTION SHEET(S) EFFECTED 0 4/19/17 PSB INITIAL SUBMITTAL - COUNTY EROSION CONTROL ALL 1 4/25/17 PSB COUNTY EROSION CONTROL COMMENT RESUBMITTAL C3.0, C3.1, C3.2, C3.3 2 5/2/17 PSB COUNTY EROSION CONTROL APPROVAL C3.0, C3.1, C3.2, C3.3 142 SHERLOCK DRIVE STATESVILLE, NC PARCEL ID: 4755875333 & 4755871399 VICINITY MAP SCALE: NOT TO SCALE I o.0 I RO "AIlk — 0.1-2 ---� _ —_ I REV I DATE I BY I DESCRIPTION I SHEET(S) EFFECTED I r DENR-LAND QUALITY STORMWATER PERMITTING INDEX OF DRAWINGS 00 I o � z Ti D l- n Al-) z „ -00 nl >�� z �J Sheet No. Sheet Title C0.1 COVER C0.2 EXISTING CONDITIONS C0.3 DEMOLITION PLAN C1.0 SITE PLAN - PHASE 1 CIA SITE PLAN - PHASE 2 C2.0 GRADING PLAN - PHASE 1 C2.1 GRADING PLAN - PHASE 2 C3.0 EROSION CONTROL PLAN - P-IASE 1 C3.1 EROSION CONTROL PLAN - PHASE 2 C3.2 EROSION CONTROL DETAILS C3.3 EROSION CONTROL DETAILS C4.0 SITE DETAILS C4.1 ISTORM WATER DETAILS C4.2 ISTORM WATER DETAILS REV I DATE BY DESCRIPTION SHEET(S) EFFECTED G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625-8505 PHONE 704.872.2411 PAX 704.872.8281 EMAIL build@glwilson.c Commercial and Industrial Construction Since 1945 \SON„BUi<o/2 N, CARD J oFtPORq = E S'6 F-0267 SEAL 17365 s G F' *GINEC:�,` 0 1996 ry CARO '%, MARK ZPR.,. 5/2/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 DESIGN NO.: 2016-075 DRAWN BY : PSB ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, INC 28625 COVER SHEET Coo I a � 1 I 4 I 11 878ep A\\ �i --- \ \ — —eas\ \ \ Coo' i1 77 ---897_--� AA,111 \ \ \ it p. FPORCH \ \ N O 1 m \ 1 STORY \ \ \ \ \ \ \ \ \ \ �- I I I I CK DWELLING WE L NG a2 �v ��----- v �' I CONIC1 SLAB' 896.7100' 84')n,no° b / I I ,J r 00.00 / \\- $ N\8o4s11'w I I I/ I i l l l I l l I Il I I �/ 1 V o� I Ali - ,� I I I I Ag2» W a 2 D y F62 28 �C)� I� R'"ERTY LINE -R'r'ERTY LINE (NOT SURVEYED) A� NENT _E3ACK rA"3 LINE SALARY SEWER PIPE S RM DRAIN PIPE `EC- -RE LINE W SSW SS LEGEND OF SYMBOLS AND ABBREVIATIONS XT: CB - CATCH BASIN CUP - CORRUGATED METAL PIPE CO - CLEAN OUT DID - DEED BOOK D. - DROP INLET ECM - EXISTING CONCRETE MONUMENT EP - EXISTING IRON PIPE PROJECT SITE DATA: _IR - EXISTING IRON ROD EN - EXISTING NAIL EGG - EDGE OF GRAVEL Owner: SMG LEASING, LLC EOP - EDGE OF PAVEMENT 208 OLD MOCKSVILLE RD FH - FIRE HYDRANT STATESVILLE, NC 28625 FP - FV -FIRE FAG POLE VALVE Deed Bk. 2462 Pg. 1183, GM - GAS METER Deed Bk. 2158 Pg. 1131 GV - GAS VALVE SW - GUY WIRE - Project Street Address: 212 Old Mocksville Road, Statesville, NC 28625 HDPE - SMOOTH BORE HIGH DENSITY POLYETHYLENE PIPE HVAC - HEATING/COOLING UNIT - Location: Statesville ETJ, Iredell County, North Carolina LPST - LAMP POST - Parcel ID: 4755875333 & 4755871399. (M) - MEASURED - Project Parcel Area: 5.3 ±Ac. NCGS - NORTH CAROLINA GEODETIC SURVEY - Project Parcel Zoned: RA. PBX - PM - POWER BOX POWER METER - Project Site Vegetation: Wooded. Poe - POINT OF BEGINNING - Watershed Data: The project does not lie within a Watershed. (R - -REECCOR POLE P) ORDED - Site Parcel Flood Statement: The subject parcel is not situated within a Special Flood R/W - RIGHT-OF-WAY Hazard Area, Zone X according to Flood Insurance Rate Map - Community Panel No. RCP - REINFORCED CONCRETE PIPE 3710475500E, Effective Date: 3/18/2008. SDMH - STORM DRAIN MANHOLESSMH - SANITARY SEWER MANHOLE - Survey Reference: Topographic Information prepared by G.L. Wilson Building Co. Soar. - SQUARE FEET - Horizontal Control based & Vertical Control based on assumed coordinates. wv - WATER VALVE G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625-8506 PHONE 704.872,2411 Fv 704.872,8281 EMAIL build@glwilson.mm Commercial and Industrial Construction Since 1945 S\`�uiuuvu„ ON B0/4 o,-, ,. CARP''% GFtPOgq G z �FE S" G _ _ TF n ' a� F-0267 " SEAL 1365 N ` 2 P 1 ',`� CINEE:�,` PTh CARGO 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 DESIGN NO.: 2016-075 DRAWN BY : PSB ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 EXISTING CONDITIONS C002 LEEiEND ABBREVIATIONS TEXT: CB - CATCH BASIN CMP-CORRUGATED METAL PIPE CO - CLEAN OUT DB - DEED BOOK DI - DROP INLET ECM - EXISTING CONCRETE MONUMENT EIP - EXISTING IRON PIPE EIR - EXISTING IRON ROD EN - EXISTING NAIL EOG - EDGE OF GRAVEL EDP - EDGE OF PAVEMENT FH - FIRE HYDRANT FP - FLAG POLE FV - FIRE VALVE GM - GAS METER GV - GAS VALVE GW - GUY WIRE HOPE - SMOOTH BORE HIGH DENSITY POLYETHYLENE PIPE HVAC - HEATINGICOOLING UNIT LPST- LAMPPOST (M)-MEASURED NCGS - NORTH CAROLINA GEODETIC SURVEY PBX -POWER BOX PM - POWER METER POB - POINT OF BEGINNING PP - POWER POLE (R)- RECORDED RNV- RIGHT-OF-WAY RCP - REINFORCED CONCRETE PIPE SDMH - STORM DRAIN MANHOLE LINE: PROPERTY LINE PROPERTY LINE (NOT SURVEYED) EASEMENT SETBACK WATER LINE SANITARY SEWER PIPE STORM DRAIN PIPE FENCE FORCEMAIN TREE LINE W SSW SS FM M M FM FlA FN 0 ro BEAVER FARM R0. WN E F 5 0 2' *SITE* o �O g �� gW QP O� SHERLOCK DR INTERSTATE 40 F US HWY 64 VICINITY MAP NOT TO SCALE PLANTING SCHEDULE PHASE 1 SYMBOL QTY. COMMON NAME SCIENTIFIC NAME MIN. SIZE SHADETREES 4 RED MAPLE Acer rubrum 2.5" CAL./8' HT 0 SHUMARD OAK Quercus shumardii 2.5"CAL./8' HT. 0 LITTLELEAF LINDEN Tilia cordata 2.5"CAL./8' HT 4 LACEBARK ELM Ulmus parvifolia 2.5"CAL./8' HT 0 SOUTHERN RED OAK Quercus falcata 2.5"CAL. 8' HT ORNAMENTAL TREES a 4 WASHINGTON HAWTHORN Crataegus phaenopyrum 1.25"CAL./6' HT. /"0 4 EASTERN REDBUD Cercis canadensis 1.25"CAL./6' HT. LARGE SHRUBS 7 JAPANESE ANDROMEDIA Pieris Japonica 3' HT. 7 CHINESE HOLLY Ilex cornuta 3' HT. 7 THUNBERG SPIREA Spirea thunbergii 3' HT. 7 OAKLEAF HYDRANGEA Hydrangea uercifolia 3' HT. 7 SHOWY JASMINE Jaminum floridum 3' HT. 25RADIUS e 6 1/2- 8 RADIUS .I NOT TO SCALE -V VALLEY CURB SECTION 18° 6" 12" d - PAVING j� /� Obi Q° F'00°od \//i O�ooOT000O�e NOT i0 SCALE STANDARD CURB & GUTTER SECTION R20.5' R25.8' I r1O ' ��R4.0' !x!�-1 . _1 \'' �- TYPE „A„ LANDSCAPE I 99.37 y x e BUFFERYARD -r- 6" COMPACTED ABC STONE BASE, F _ �, ��1176.19' MCE LJ Mffi GRAVEL PAVING SECTION 25 FRON 1.5" S9.58 - R62.0' 2"-19C OF S9.5B 8" COMPACTED ABC STONE BASE EXISTING WOODLANDS TO SERVE AS TYPE "N' o p� o � TjN�u„ < \ LANDSCAPE BUFFERYARD f 0 00 o0c °o ob o o °oo o } \ HD ASPHALT PAVING SECTION \\ ` V NOT TO SCALE 2" S9.5B 6" COMPACTED ABC STONE BASE \\ 15'.65' SHEET NOTES: \ 0 0°�w�oU °c �� ?o A �� R62.0' 4.0' o) Kam- o�c_ 1. SEE SHEET C2.0 FOR STORM DRAINAGE DATA CHARTS. r 2. SEE SHEET CIA FOR PHASE 2 CONSTRUCTION. � \ 0 3. SEE SHEET M1,1 FOR MECHANICAL EQUIPMENT. 9 4. SEE SHEETS C4.1 AND C4.2 FOR STORMWATER MANAGEMENT I \ DETAILS. 5. DIMENSIONS ARE TO FACE OF CURB UNO. STANDARD ASPHALT PAVING SECTION NOT TO scALE��;� VALLEY CURB, SITE DATA Owner: SMG LEASING ASSOCIATES 208 OLD MOCKSVILLE ROAD STATESVILLE, NO 28625 704-838-8245 Project Address: 142 SHERLOCK DRIVE STATESVILLE, NORTH CAROLINA 28625 Property Information: PIN: 4755-87-5333 & 4755-87-1399 DEED BOOK 1478, PAGE 2186 DEED BOOK 2462, PAGE 1183 TOTAL ACREAGE = 5.3 AC. ZONING: RA SETBACKS: FRONT = 25' REAR = 25' SIDES = 10' MAX. BUILDING HT. = 50' Parking: REQUIRED PARKING (PHASE 1) USING THE CATEGORY OF 'HEALTH/DENTAL PRACTITIONERS OFFICE" FROM THE CITY OF STATESVILLE UNIFIED DEVELOPMENT ORDINANCE. 6.0 SPACES PER 1,000 GFA 5,830/1,000 X 6.0 = 35 SPACES PROVIDED PARKING STANDARD PARKING SPACES (9'X20') = 33 REGULAR HANDICAP SPACES (13'X20') = 1 VAN AC(.F'�';1RIF HANDICAP SPACES (16'X20') Required Landscaping: TYPE "A" LANDSCAPE BUFFER YARD 8' WIDE CONTAINING (PER 100 LINEAR FEET) 2 ORNAMENTAL TREES (12 POINTS @ 6 EACH) 14 MEDIUM SHRUBS (28 POINTS @ 2 EACH) TOTAL POINTS PROVIDED = 40 (REQUIRED) "STREET" BUFFER YARD 8' 'WIDE CONTAINING (PER 100 LINEAR FEET) 3 SHADE TREES (36 POINTS 0 12 EACH) TOTAL POINTS PROVIDED = 36 (REQUIRED) PARKING LOT LANDSCAPE REQUIREMENTS NUMBER OF SPACES 35 REQUIRING - 38 POINTS 4 SHADE TREES - OR- 2 SHADE TREES AND 3 ORNAMENTAL TREES SEE DETAIL THIS SHEET FOR PLANT SCHEDULE, AND SHEET C4.0 FOR TREE PLANTING DETAIL. Survey Information: PLAT AND BOUNDARY SURVEY PREPARED BY OTHERS TOPOGRAPHIC INFORMATION FIELD GATHERED BY G.L. WILSON BUILDING COMPANY ON APRIL 20, 2016. SU M , 1 Q S I ATESVILLE HMA INC. O..•. D.B. 1221, PG. 373 � V PIN 4755777934 tM� y /' N �/ `\ ZONED 0+12 WC <' 7 Y 1 _ SEE PLUMBING w �� EXISTING WOODLANDS TO �y .0 DRAWINGS FOR � � � SERVE AS TYPE "A" PENETRATION LOCATION r !� LANDSCAPE BUFFERYARD t WATER 8c SEWER NOTES: -o -p SANITARY SEWER CO MEo+.°"��5 j SEE CONTINUATION pvG SS�OP HEET P1.2 FOR NEW 2" FORCEMAIN �+ 1 -� 'O LF �pgo)o (� Sap5 ALL EXISTING UTILITIES SHALL BE LOCATED PRIOR TO CONSTRUCTION. g. r� INV.= 876.15 AA 15 gY�25 /> ALL NOTIFY THE ENGINEER OF ANY POTENTIAL CONFLICTS. -n� 0 0 -� .0 �� p�G YT S$ �� N ✓ 2. ALL WATER AND SEWER ITEMS SHALL BE INSTALLED IN COMPLIANCE 6 WITH ALL LOCAL AND STATE REGULATIONS. ALL WATER AND SEWER 6c'o �,.�-/ , l ITEMS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. r 3. CONTRACTOR SHALL COORDINATE ALL UTILITY CONNECTIONS WITH THE LOCAL MUNICIPALITY'S WATER AND SEWER DEPARTMENTS. I\ ✓ 2 y 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING. ALL NEW 5' CONCRETE / C9�d� (� EXISTING UTILITIES. SIDEWALK on /14 "5. INSTALLATION OF WATER METERS &TAPPING OF WATER MAINS SHALL BE INSTALLED / PERFORMED IN ACCORDANCE WITH ALL MUNICIPAL GUIDELINES. CONTRACTOR SHALL COORDINATE INSTALLATION OF THESE ITEMS WITH THE GOVERNING MUNICIPALITY. 6. CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL UTILITIES WTH THE APPROPRIATE UTILITY COMPANY. 7. UPON COMPLETION ALL WATER LINES SHALL BE FLUSHED, PRESSURE TESTED, AND DISINFECTED IN THAT ORDER. 8. SEE BUILDING PLANS FOR EXACT EXIT LOCATION(S) OF UTILITIES FROM THE BUILDING. NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 9_g0 9. ALL PIPE MATERIALS, BACKFLOW PREVENTERS, VAULTS (ABOVE OR BELOW GRADE), WATER METERS, AND SAN. SEWER MANHOLES, WITHIN THE GOVERNING MUNICIPALITY JURISDICTION SHALL BE APPROVED BY THE GOVERNING MUNICIPALITY. TECHNICAL REVIEW COMMITTEE PLAN APPROVAL SIGNATURE BLOCK Planning Director Date Pu61ic VYorks Director Date Electrical Utilities Director Fire Marshal Date Date G.L. WILSON BUILDING COMPANY D WILSON , INC 28625-8506 PHONE04.87224 1R P"0704.872.8281E EIM Ebuid@glwilson..com Commercial and Industrial Construction Since 1945 I \`,Nlnnil�Uiii \\2 eUl4Oti,. .` ��N, CARP �, V POR, o Z��4�oFE 1pti. _ F-0267 - - _ SEAL 7365 799 rN caR° %,, MARK ZPR•° 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUED DATE 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 SITE PLAN PHASE 1 C100 o F BEA VIER FARM RD. WN E � S o *SITE* o QP yrw' SHERLOCK DR INTERSTATE 40 z Q US HWY 64 VICINITY MAP NOT TO SCALE f� LEGEND ABBRE IA TEXT: CB - CATCH BASIN CMP - CORRUGATED METAL PIPE CO - CLEAN OUT DB - DEED BOOK DI-- DROP INLET ECM - EXISTING CONCRETE MONUMENT EIP - EXISTING IRON PIPE EIR - EXISTING IRON ROD EN - EXISTING NAIL EOG-EDGE OF GRAVEL EOP - EDGE OF PAVEMENT FH - FIRE HYDRANT FP - FLAG POLE FV - FIRE VALVE GM - GAS METER GV-GAS VALVE GW - GUY WIRE HDPE - SMOOTH BORE HIGH DENSITY POLYETHYLENE PIPE HVAC - HEATINGICOOLING UNIT LPST- LAMPPOST (M)-MEASURED NCGS - NORTH CAROLINA GEODETIC SURVEY PBX -POWER BOX PM - POWER METER POB - POINT OF BEGINNING PP -POWER POLE (R) - RECORDED RAN - RIGHT-OF-WAY RCP - REINFORCED CONCRETE PIPE SDMH - STORM DRAIN MANHOLE SSMH - SANITARY SEWER MANHOLE SQ.FT. - SQUARE FEET WV - WATER VALVE SITE DATA Owner: SMG LEASING ASSOCIATES 208 OLD MOCKSVILLE ROAD STATESVILLE, NC 28625 704-838-8245 Project Address: 152 SHERLOCK DRIVE STATESVILLE, NORTH CAROLINA 28625 Property Information: PIN: 4755-87-5333 & 4755-87-1399 DEED BOOK 1478, PAGE 2186 DEED BOOK 2462, PAGE 1183 TOTAL ACREAGE = 5.3 AC. ZONING: RA SETBACKS: FRONT = 25 REAR — 25 SIDES = 10' MAX. BUILDING HT. = 50' Parking: REQUIRED PARKING PHASE 2 USING THE CATEGORY OF "HEALTH/DENTAL PRACTITIONERS OFFICE" FROM THE CITY OF STATESVILLE UNIFIED DEVELOPMENT ORDINANCE. 6.0 SPACES PER 1,000 GFA 5,830/1,000 X 6.0 = 35 SPACES PROVIDED PARKING STANDARD PARKING SPACES (9'X20') = 33 REGULAR HANDICAP SPACES (13'X20') = 1 VAN ACCESSIBLE HANDICAP SPACES (16'X20') = 1 THE INTENT OF THIS PLAN IN TO MEET THE REQUIREMENTS OF THE CITY OF STATESVILLE LANDSCAPING ORDINANCE, ADDITIONAL LANDSCAPING (NOT SHOWN ON THIS PLAN) MAY BE PROVIDED BY THE OWNER TO FURTHER ENHANCE THE APPEARANCE OF THE OVERALL SITE / PROJECT. PLANTING SCHEDULE PHASE 2 SYMBOL QTY. COMMON NAME SCIENTIFIC NAME MIN. SIZE SHADE TREES 0 RED MAPLE Acer rubrum 2.5" CAL./8' HT 0 SHUMARD OAK Quercus shumardii 2.5"CAL./8' HT. 0 LITTLELEAF LINDEN Tilia cordata 2.5"CAL./8' HT 4 LACEBARK ELM Ulmus parvifolia 2.5"CAL./8' HT 0 SOUTHERN RED OAK Quercus falcata 2.5"CAL. 8' HT ORNAMENTAL TREES 2 WASHINGTON HAWTHORN Crataegus phaenopyrum 1.25"CAL./6' HT. 2 EASTERN REDBUD Cercis canadensis 1.25"CAL./6' HT. LARGE SHRUBS 0 JAPANESE ANDROMEDIA Pieris Japonica 3' HT. 0 CHINESE HOLLY Ilex cornuta 3' HT. 0 THUNBERG SPIREA Spirea thunbergii 3' HT. 0 OAKLEAF HYDRANGEA Hydrangea uercifolia 3' HT. 0 SHOWYJASMINE Jaminum floridum 3' HT. 2 R20.5' TYPE"A"LANDSCAPE \ _ 2 BUFFERYARD, SEE SHEET C1.0 INSTALLED DURING PHASE 1 ri -a 1. SEE SHEET C4.0 FOR STORM DRAINAGE DATA CHARTS 2. SEE SHEET C1.0 FOR PHASE 1 CONSTRUCTION- o - �v SMG LEASING ASSOCIATES, GP ti �e \- D.B. 1478, PG. 2186 PIN 4755 87 5333 1i .. R4.0' LEGEND OF SYMBOLS LINE: NE PROPERTY LI PROPERTY LINE (NOT SURVEYED) EASEMENT — — — SETBACK — — — — — — — — — — — — — — WATER LINE W W SANITARY SEWER PIPE SS SS STORM DRAIN PIPE FENCE TREE LINE Required Landscaping: TYPE "A" LANDSCAPE BUFFER YARD 8' WIDE CONTAINING (PER 100 LINEAR FEET) 2 ORNAMENTAL TREES (12 POINTS @ 6 EACH) 14 MEDIUM SHRUBS (28 POINTS @ 2 EACH) TOTAL POINTS PROVIDED = 40 (REQUIRED) "STREET" BUFFER YARD 8' WIDE CONTAINING (PER 100 LINEAR FEET) 3 SHADE TREES (36 POINTS 0 12 EACH) TOTAL POINTS PROVIDED = 36 (REQUIRED) PARKING LOT LANDSCAPE REQUIREMENTS NUMBER OF SPACES 35 REQUIRING — 38 POINTS 4 SHADE TREES —OR- 2 SHADE TREES AND 3 ORNAMENTAL TREES SEE DETAIL THIS SHEET FOR TREE PLANTING DETAIL AND PLANT SCHEDULE Survey Information: PLAT AND BOUNDARY SURVEY PREPARED BY OTHERS TOPOGRAPHIC INFORMATION FIELD GATHERED BY G.L. WILSON BUILDING COMPANY ON APRIL 20, 2016. .0' ZONED RA�t �4.0 \ r WPM R4.0' \JL3t8 X.` R62.0' 6� O y R1320 "STREET" LANDSCAPE \ BUFFERYARD SEE SHEET C1.0, \ 6� PHASE 1 CONSTRUCTION \\ yx31 A�ox `� \ R38.0' GRAVEL PAVING SECTION \ \ R62.0' 0 STANDARD ASPHALT PAVING SECTION HD ASPHALT PAVING SECTION \ \NI EXISTING WOODLANDS TO SERVE AS TYPE "A" LANDSCAPE BUFFERYARD. f t j( \ EXISTING WOODLANDS TO SERVE AS TYPE "A" LANDSCAPE BUFFERYARD \ i jC' \ /l \ 20 0 10 20 40 60 TECHNICAL REVIEW COMMITTEE PLAN APPROVAL SIGNATURE BLOCK Planning Director Date Public Works Director Date Electrical Utilities Director Date Fue Marshal Date G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NO 28625-8506 a"o"E 704.872.2411 r. 704.872.8281 EMAIL build@gWlson.com Commercial and Industrial Construction Since 1945 BU/�oi2; CAR0 \�SpN io ?•°�i SPO=pA °S(t F-0267 T � =- _ :171 CC/AiL On 1996 rH CA?,° 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 �.,...-o,., vrwvvry at : raa ISSUED DATE : 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 SITE PLAN PHASE2 (FUTURE) C 1 0 1 + \ + + + + + + + + + + + + + + + j 13 PAC + + + + + +:r-.+ + \ + + + + + + + + + + + + + + +++ 0 c 0. s a8 -- CD CD +, c- /C/ i \+ + + + + + I FG 895.D2 - G 8 " 1,71 + \ + + + + < u� )_ l +\ �+ + + + + + D 1` SPA,S \+O + + + + + �y5 ° 9ne Z I SMG LEASING ASSOCIATES, LLC r {- \ + + + -.+ c; 8 _ L' O I I D.B. 4755 7 399 + + 1 � E �y _ _ PIN 4�55 87 1399 +\ + + D \+� + + F,: 8 9.18 NE RA 1I + + + + + + ++ +++ + Fc 9O +Q+ � + - + + + + + +\ + F \ J + + + + + + + + + + + + + + + + D \ n + z \ + I + + + + + + + + o O _co 00M _ _ - \ 1 + + + + + + + + Ppl� ram... _ SMG LEASING ASSOCIATES, GP C UNITS�a -J + + + + �+ + + + + + \ oo _- - D.B. 1478, Pc. 2186 f + I � . + + + + + + + PIN 4755 87 5333 ._\_ '..+ + + + ... + +:. + + ++ \ - CDZONED RA ---- - \I- n +1D+ �� " + + + + + NECK ITS --12" PVC YI \ JJ + I + -♦- +yj + + ' + + + + + " + + + + + - - -- PROPOSED PS - � TOP EL.= 681.25 .� -�` + I + + .. + + + + + + \ -. ;. / - _. _. _ _._. - _. _.. __ - __ _ - •o� INV IN"= 875. + 1+ _+ + + + + + + + + + + + + + + + + ST4IESVILLE HMA INC. + I + + + + r + + + + + y D.B. 1221. PG. 373 + + + + + + + + + + PIN 4755777934 + + + + + + + r91d� ar I + + \ + ZONED o+Iz + + I + ++ + + + + + - + + + + I + + + + + + + + + + + + ++ +++++++ +++++++ \ + I + ... + + + + + 1 + + + + + + + + \ d6 + + + + + + + +t + + + + +. + + +_ + + + ++ + + SHEET NOTES: 1. SEE SHEETS C4.1 AND C4.2 FOR STORMWATER MANAGEMENT + +�\\�- -\. �\ /j �� -- _ DETAILS. 2. SPOT ELEVATIONS ARE TO TOP OF CURB UNO. + - _ h\��� =� j + En En --- - - t _ + \ + + + + + + $ - - --- - +' } + + + + + + -+ + + + + + + + +- + �--,1 \ + \ + + + + + + + + + + +" + + \\ + + + + -} + \+ +' - + + + + + + + + + + + + 4 R + + + + + + + + + + + +, + + + + + �+��+` - \+ + + + + + + + + + + + + + + + + + + �! + + + + +- + + + + + + + + + + + + + + + + + + + -F + + + + + + 4- + + + + + + + + + + + - + + + + + + + + + + + + - + _..+ + + + + + +. + ...+ + ...+ + + -+. + + + + +-+... NAME ON Sewer Network Table STRUCTURE UP STRUCTURE DOWN INVERT FT UP INVERT FT LENGTH FT SLOPE 9 MATERIAL SHAPE SIZE IN WIDTH IN MANNING'S N P6 CB-3 CB-2 882.87 883.35 24.00 2.011 Concrete Circular 15.0 0.0 0.0130 P7 CB-4 CB-3 874.67 882.67 126.90 6.304 Concrete Circular 15.0 0.0 0.0130 P13 is-10 CB-4 873.18 874.47 29.01 4.447 Concrete Circular 15.0 0.0 0.0130 P12 JB-10 CB-1 873.13 874.06 53.49 1.730 Concrete Circular 18.0 0.0 0.0130 P17 JB-13 JB-10 872.74 872.93 19.03 1.000 Concrete Circular 18.0 0.0 0.0130 P4 CB-7 CB-8 883.42 884.70 63.97 2.001 Concrete Circular 15.0 0.0 0.0130 P3 CB-5 CB-7 874.60 883.17 99.16 8.638 Concrete Circular 18.0 0.0 0.0130 P14 JB-11 CB-6 873.23 874.66 48.47 2.943 Concrete Circular 15.0 0.0 0.0130 P15 JB-11 CB-5 873.23 874.35 13.25 8.488 Concrete Circular 18.0 0.0 0.0130 P16 JB-12 JB-11 872.74 872.98 13.28 1.808 Concrete Circular 18.0 0.0 0.0130 P18 18" FES OCS 868.95 869.50 155.13 1.00 Concrete Circular 18.0 0.0 0.0130 Sewer Network Table Sewer Network Table NAME NORTHING EASTING RIM ELEV FT BASE ELEV FT INVERT -IN ELEV FT INVERT -OUT ELEV FT TYPE STRUCTURE ID INLET ID CB-1 757295.77 1458374.09 877.76 874.06 N/A 874.06 Box Structu a Box2 Drop Inlet CB-2 757146.02 1458232.61 887.35 883.35 N/A 883.35 Box Structu a Box2 Catch Basin CB-3 757166.75 1458244.72 886.94 882.67 882.87 882.67 Box Structu a Box2 Catch Basin CB-4 757240.95 14 88347.66 878.47 874.47 874.72 874.47 Box Structu a Box2 Drop Inlet JB-10 757264.49 1458330.70 878.93 872.93 873.18 872.93 Box Structu a Box Ring & Cover JB-13 757282.70 1458325.17 878.87 872.54 872.74 870.74 sum 30" N o las MH1 Rinq & Cover CB-6 757380.71 1458360.54 879.08 874.66 N/A 874.66 Box Structu a Box2 Drop Inlet CB-8 757407.00 1458153.48 888.66 884.70 N/A 884.70 Box Structu a Box2 Catch Basin CB-7 757418.34 1458216.43 888.70 883.1 883.42 883.17 Box Structu a7 Box2 Catch Basin CB-5 757402.06 1458314.24 880.03 874.35 874.60 874.35 Box Structu e Box2 Drop Inlet JB-11 757388.89 1458312.76 880.38 1872.98 873.23 872.98 Box Structu e Box2 Ring & Cover JB-12 757375.81 1458-110.52 880.19 1872.54 879.74 870.74 s -mn, Ring & Cover G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NO 28625-8506 PHONE 704.872.2411 FAx 704.872.8281 EMAIL build@gWilson.com Commercial and Industrial Construction Since 1945 `„Iluinuili CARS G�FtPORgT �� ?� �aFE 14 F o'__ �y F-0267 SEAL Iy cnRo 0,; 4ARK 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 GRADING & DRAINAGE PLAN PHASE 1 + \ + + + + + t T + I + + + + + + + + + -r / / Q� \ � J..-.- `\ - \+ + + + + + + + + + + + + + + 13 SPAC + + yj V + \\+ + + + + + + + + + + + + + + +___ + + + _+ + + + + + j + + + + + + + + ++++++++ �e - � + \+ + + + + + + + + � + \ + + + + + + + + + + + + + \ + + + + + + + 4\ �+ + + + + + \+o+++++ \°m+ + +++- + vv + + 01) � 0 +\}+++ Q -- O - - - - FA � ese o ' o o SMG LEASING ASSOCIATES, GP - �- x .-< D.B. 4755 E� unlTs CO PIN 4755 87 533J 333 - V C ZONED RA - -- C \ Y = o r - --_i i �q- � FC F's8025. \\ / .'.. d ..*. 88OROPOSED PS 0 - TOP EL _ 4. ' 8911.2 N / IN - r - �r w I V 875-69 \ y -- - 17 5P ES SHEET NOTES: 1. SPOT ELEVATIONS ARE TO TOP OF CURB UN0. 2. THE FOLLOWING STRUCTURES ARE TO BE CONVERTED FROM DROP INLETS TO CATCH BASINS: CB-1, CB-4, CB-5, AND CB-6. \\ �/ 71 + ---e ;aye — ii + + TI - \ +� +\ + + T -ass _ = + + 4- + + T + + _ _ _-f� + + + + + + + + - + + + + + + + - +-- + + + + + \+ - + + + + + + + + + + +\ + 4- + + + + + + + + + + + + + + + + + + ` + + + + + + + _ + + + + + + + + + + \ + + + + + + + + + + + + + + + + + + 20 0 10 20 40 60 + + + + + + + + + + + + \+ + + + + + + + + + + + + + + +\ + + + + + + + + + + + + + + + I � I / -E9400n 7 0 v o o � I I 1 + + �-. + + j I + + + - + + 40 + + + + - - + + + + + + + + + + + + + + + + + + S+MG+ L�41I G+A�SMATFS- LLC B. 24 2, P01183 + I + V + + + PIN 4T55 87t39� + + + + - + + + +ZONEDFRA + I + + + + + + + + + I0+ + + + + + + + + + + + + + + I-� + + + + + + + + + +I + + + + + + + + /I+ + + + + + + + + _ +I + + + + + + + + + I+ + + + + + + + + r +I + + + + + + + + + .+J + + + + + + + + + --- ��� + I + + + + + + + + + + + + + + + + + + - STATESVILLE HMA INC. / + + + ' + + + + + + D.B. 1221, PG. 373 + +. + + + + + + + + + PIN 4755777934 + + I + + +- + + + + — t ZONED 0+12 + __+ + + -+ + + + + + + + + + I + + + + + + + �� lu + + + + + + + + — + / I + + + + + + + + + + + + + + + + + + + + + + + + + + + + + I+ + + + + + + + 41 + + + + + + + + + I+ + + + + + + + I + + + + + + + + + + + + + + + + + + I + + + + + + + + + I + + + + + + + +I t + I + + + + + I + + + + G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 2862"506 PHONE 704.872.2411 FAX 704.872.8281 EMAIL build@glwilson.com Commercial and Industrial Construction Since 1945 \\\unllUq °SpN Bu/� ''•, �\� CARP `.�\, RPOR Oi,Gc;•/ \�Ot�,�oEE / , F-0267 7365 SEAL 1\0 O � y caR° ",, MARK ZP ����lllll 111\\\\\ 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUED DATE : 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 GRADING PLAN PHASE 2 (FUTURE) � C201 � 12" FILTREX SILTSOXX DOUBLE STACKED INSTALL IN ACCORDANCE TU IRS APPROVED BY IREDELL COUNTY / ���— \ ` „� RECOMM ND TI NS. DEVELOPMENT SERVICES— PLANNING DIVISION �S ass ASS ��`= — EROSION CONTROL SECTION MAY 22 2017, 1 ) PREOJECT ID IREDE-2017-078 I BAFFLES SKIMMER BASIN C3.3 ' � j t �. ,I LEGEND OF S I �®L� I C3.3 S III AND ABBREVIATIONS TEXT: k.x� CB - CATCH BASIN CMP- CORRUGATED METAL PIPE CO- CLEAN OUT \ FENCE C3.2 \ DB - DEED BOOK DI - DROP INLET ECM - EXISTING CONCRETE MONUMENT EIP- EXISTING IRON PIPE ON ROD EN- EXISTING NAIL EOG - EDGE OF GRAVEL EDP -EDGE OF PAVEMENT FH - FIRE HYDRANT - - - �\ \ FP - FLAG POLE FV-FIREVALVE GM - GAS METER GV - GAS VALVE - ` - \\ • -� �� GW- GUY WIRE I - •,�n'C \V ` O _ HOPE - SMOOTH BORE HIGH DENSITY POLYETHYLENE PIPE- HVAC- HEATING/COOLING UNIT LPST- LAMPPOST SKIMMER BASIN (M)-MEASURED - - - NCGS - NORTH CAROLINA GEODETIC SURVEY OUTLET STRUCTURE ,, ��m :XY`i 12 PBX - POWER BOX I-'1--�.—� l� C3.2 North Carolina One —Call Center MOO T. Ne.drsvi,. Ro.d, S.ile M7 Greensboro NortL Carolina 27407 (010) 65 -5760 o2 DAYS KFIX DIOUNG IN NORM CWOUNR CALL 1-800-632-4949 UNDERGROUND LOCATORS. CONTRACTOR SHALL CONTACT THE UNDERGROUNU LOCATORS EVERY 10 DAYS FOR AN UPDATE TO UTILITY LOCATIONS. Call BEFORE you DIG! 11It's The Law" GENERAL NOTES 1. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH NCDENR'S DESIGN MANUAL AND PRACTICES AND SHALL BE INSPECTED AND MAINTAINED ON A MONTHLY BASIS AND AS NEEDED FOLLOWING PEAK RAINFALL EVENTS. 2. THE SOIL TYPES ARE CmD2 (CECIL SANDY LOAM 10-15%) AND CsE2 (CECIL SOILS, 15-25%) 3. THE SUBJECT PROJECT IS NOT LOCATED IN A PROTECTED WATERSHED DISTRICT. 4. TOPOGRAPHIC DATA WAS FIELD GATHERED BY G.L. WILSON BUILDING COMPANY ON APRIL 20, 2016. 5. EROSION CONTROL MEASURES ARE TO BE IN PLACE BEFORE LAND DISTURBING ACTIVITIE COMMENCE. E SEED ALL EXPOSED AREAS PER THE STABILIZATION TIMEFRAME TABLE AS SHOWN ON SHEET C3.2. 1Q 7. CONCERNS WITH EROSION CONTROL ISSUES DURING CONSTRUCTION ARE TO BE DIRECTED TO: D. MARK TART, PE G. L. WILSON BUILDING CO. 190 WILSON K ROAD PM- POWER METER POB- POINT OF BEGINNING PHONE: V704 87222411 EXT. 247 \ \ \ PP -POWER POLE - -- �` _. -, � �\ Y - / T R/W-RIcoRDED I �X Asa\/' , - 8. STORM WATER FLOWS OFF THE SMG LEASING SITE ON THE EAST SIDE. THE STORMWATER THAT RNV-RIGHTOR WAY ]- -- \ FLOWS TOWARD THE EAST SHEET FLOWS TO AN EXISTING WET WEATHER DRAIN FLOWING TO THE RCP -REINFORCED CONCRETE PIPE SILT FENCE � � � _ - C3.2 i \ ` ' ; � / ` NORTH. THIS CHANNEL CARRIES STORMWATER FROM INTERSTATE 40. SDMH -STORM DRAIN MANHOLE SSMH- SANITARY SEWER MANHOLE> - SOFT. - SQUARE FEET WV- WATER VALVE N T TI LEGEND SYMBOLSI - � 7 v COS RUC ON SEQUENCE I SILT FENCE - - -- AO / C3.2 i -" ` 1. CC\TACT IREDELL COUNTY EROSION CONTROL INSPECTOR RANDALL MOORE LINE: I / / _ / o \ v (-=4)832-2352 FOR AN ONSITE PRE -CONSTRUCTION MEETING. PROPERTY LINE 2 C LAR SITE AS NECESSARY 10 INSTALL PHASE 1 EROSION CONTROL MEASURES. r 3. LC ATE LIMITS OF CONSTRUCTION. PROPERTY LINE (NOT SURVEYED) _ I � � � � V � EASEMENT - - 4 INSTALL CONSTRUCTION ENTRANCE AND SILT FENCE AS SHOWN ON PLAN. SETBACK - - - - - - - - - - - - - _ j _ \ 5 INSTALL SKIMMER BASIN, OUTLET STRUCTURE; TEMPORARILY SEED ALL NEW DISTURBED WATERLINE W W \._____ �.-..—___- - _. / SANITARY SEWER PIPE SS SS _ /- - - / �-------- \ � �\ \ A -.=AS FROM THE INSTALLATION OF NEWLY INSTALLED EROSION CONTROL MEASURES. STORM DRAIN PIPE EEEI�r -EMENEI (CV ACT IREDELL COUNTY EROSION CONTROL INSPECTOR RANDALL MOORE �a 6. C T FENCE ,----� �In 704 832-2352 TO INSPECT APPROVE MEASURES. - Q' I ) TREE LINE — - Q - - _ \ V 7. ---EAR AN �� ` _ \ 8 A D GRUB E THE REMAINDER OF THE SITE, INCLUDING REMOVAL OF TREES, � NY EXISTING DEBRIS AND ALL WOODY OR VEGETATIVE MATERIAL ENCOUNTERED ON J HE SITE. � I } �� \ I _ � \ TRIP TOPSOIL AND ANY UNDESIRABLE SOIL ENCOUNTERED FROM THE CONSTRUCTION -1 ~' ~ \ \ \ N -REAS OF THE SITE. TOPSOIL AND ANY UNDESIRABLE SOIL TO BE USED IN - - - \ON -STRUCTURAL AREAS OF THE PROJECT SITE IF EXCESS MATERIAL REMAINS ONCE SMG LEASING ASSOCIATES, GP — - \ \ �` I \ � 1NAL GRADES ARE ACHIEVED. D.B. 1478, PG 2186 - - . - - �� \J 9. GRADE THE SITE, STATESVILLE HMA INC. I PIN 4755 87 5333 e�N - 10 OR FILL SLOPES GREATER THAN 7', CONTRACTOR SHALL MAINTAIN DIVERSIONS ALONG � \ I D.B. 1221, PG. 373 _ ZONED RA _ A e T -E TOP OF THE FILL SLOPE AND SLOPE DRAINS DURING THE FILL PLACEMENT STABILIZED IS - P- CESS. DIVERSIONS AND SLOPE DRAINS SHALL REMAIN IN PLACE UNTIL THE FILL CONSTRUCTION 6 / -- PIN 4755777934 / ZONED 0+12 r \ � � \ � T ENTRANCE C3.2 �_ / M� ES HAVE BEEN ADEQUATELY STABILIZED NTH ESTABLISHED VEGETATION. I - � \ 11 Mr `TAIN SILT FENCE, CONSTRUCTION ENTRANCE AND ALL SUCH OTHER SEDIMENTATION A CCU-ROL DEVICES AS MAY BE USED ON THE SITE. \ 12. SE=: ALL EXPOSED AREAS PER THE STABILIZATION TIMEFRAME TABLE AS SHOWN ON /� \\ z aHL T C3.2, 3 INS -'_L STONE BASE IN BUILDING AND PARKING AREA SUB -GRADES. BEGIN FACILITY f _ �\ \ ON -RUCTION. 000 0 ----- _ - A '4. BEG `, PHASE 2 EROSION CONTROL PLAN. iCj �� se I i�- \ A \ \ - U Q OO O 4\ EROSION CONTROL TROL SYM BO LS°000 0O°II � Oan -LIMITS CLEARING °O -0 O ° CO O 0°° -oy O TD-—TD-TEMPORARY DIVERSION ° �P OO ro0Ln I /� 0 ° x824.15 -SPOT ELEVATION OO °" -FLOW DIRECTION INDICATOROO SMG LEA NO ASSOS, LLC°O „� O O SB. zasz, Pc. 118 J PIN 4755 87 139 ERR -RIP RAP CHANNEL \... \ r ZONED RA BSZtj 0GL -GRASS LINED CHANNEL CO ° v �� }�,� \ r7TSD -TEMPORARY SLOPE DRAIN CD 0 I G1V ® CATCH BASIN - _. - ._ - -- - - - - -' � - - SF -SILT FENCE - - - - - - - - - - -� AV -OUTLET PROTECTION - - - - - - - - - - � -INLET PROTECTION . a$' Chi � � °� � t� ��� � \ � • � �, � � ��.'�\� -V � V' i � I N - - - - - - - - - - - - -FLARED END SECTION NOb813S _LNObJ .SZ - c( CA C2 - -PERMANENT SEEDING a00 -N- I TEMPORARY SEEDING O SEE CONSTRUCTION SEQUENCE FOR TEMPORARY SEEDING I V \ REQUIREMENTS - SLOPE PROTECTION - MATTING C/z E G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625-8506 PHONE 704.872.2411 Pox 704.872.8281 EMAIL build@gI%sAh I.GOrn Commercial and Industrial Construction Since 1945 5pN BU/"'''' CARP F-0267 SEAL :17/365 rh cAR° 799 MARK \1\0' 5/2/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 DESIGN NO.: 2016-075 DRAWN BY ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 EROSION CONTROL PLAN PHASE 1 C300 , 1 ® T T T t 7 1- ":. + + i-. + + + + + + + '+ + + + + + + + + + + + + 1 + `ate• + + + - +. _+ + + + + + + + -+ + + + +` + + + + +. + + + + + + + + + +. + + + + + + + + .. + + + + + + + + + + + + + + + + + + + + + + +I + J + + + + + + + + + + + + +' + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ + + + + + + + + + + + + + + + + + + + + + + + . +- + -+ + + + + + + + + + + + + + + + +' + +,+. +I, + + + + + + +- + + + + + + + 1 a + +,'k + +/� + + + + +, + + + + + + + + + + + + + + 12" FILTREX SILTSOXX \ DOUBLE STACKED + + + + + + + + + INSTALL IN ACCORDANCE + +' + + + + + + + + + + + + + \ + + + + + WITH MANUFACTURERS �` _ + + + + + + + + + RECOMMENDATIONS. F + + + + + + + + + + + + + + + �} l / + +�� + / + + + + + .. + + + + + + \ + + + + ` + + + + + + + + + + + + +\ + I + -ds pass 4s � + +� 1 + - + +,+ + + _+ + + + + + + LIMITS OF CLEARING + + + + + + + \ AREA = 2.18 ACRES + + 1 -+ + APPROVED BY IREDELL COUNTY + + + + + + + +_+ + + + + +'+ + + + + +_ + + + + + + +7+ t + t +\+ + DEVELOPMENT SERVICES— PLANNING DIVISION + + + + + + + 1 + + + + + 4- + + SILT FENCE C32 + \� r + + + — EROSION CONTROL SECTION MAY 2, 2017, + + \ PREOJECT ID IREDE-2017-078 + + + + + + + + + + + + + 11 \ < < + + + 1 P ` ` \\ z + \+ \ < _ + LIEEiEND OF SYMBOLS + + + AND ABBREVIATIONS TEXT: CB -CATCH BASIN + + + `ny- COP CLEAN OUTTED METAL PIPE + +.. DB - DEED BOOK DI - DROP INLET + + 1 �`1\���\"`\\\�\`T\\\C'`•�"J ./ d� _. \�\'�\\\ �� ECM - EXISTING CONCRETE MONUMENT - EIP - EXISTING IRON PIPE + +_ EIR- EXIBTING IRON ROD + +- EN - EXISTING NAIL + +-.-_ + EOG - EDGE OF GRAVEL _ - -- - - - - - _ EOP - EDGE OF PAVEMENT + + < - TYP FH - FIRE HYDRANT + -. +. - -+ >�< - :C33_2 -- FP - FLAGPOLE - - � � FV -FIRE VALVE + + + - GM -GAS METER I //7�� t .\. _- - GV - GAS VALVE - + + + c-(-` _ r+ < }` x .. GW -GUY WIRE % + + + + U HDPE- SMOOTH BORE HIGH DENSITY POLYETH SILT FENCE HVAC- HEATING/COOLING UNIT + +- LPST- LAMPPOST + + --. + + < . / , I PST - - _PS NCGMEASURED I < - 1 NCGS -NORTH CAROLINA GEODETIC SURVEY + -}- -{- �!- -}� _ --- - - PBX -POWER BOX + +_ -+ I + v ' ./ - _ - PM-POWERMETER - ... /,� - _ _ _ POB- POINT OF BEGINNING -+ + + VAC` - �l 7 PP- POWER POLE l+Qk — SILT FENCE --- (R)-RECORDED i- + - + I � A p16i 1 .:, �"�". � � •. _. - - C3.2 - R!W - RIGHT-OF-WAY - + + + I+ RCP- REINFORCED CONCRETE PIPE - SDMH - STORM DRAIN MANHOLE i- + + 1 + SSMH - SANITARY SEWER MANHOLE- SQ.FT. - SQUARE FEET + - .+ +- WV -WATER VALVE LEGEND O SY19iI OLS �. -I- + + + +I LINE: I- + + PROPERTY LINE + . + +Q l / IA OAd 21, PROPERTY LINE (NOT SURVEYED) - - - --- EASEMENT __-------_—_—_ + + +Wi Z c�c, Sllf _ WATERLINE W W SANITARY SEWER PIPE SS SS + + -� _ _ _ _ -. -' _ -_ - _ -. - --. < - - STORM DRAIN PIPE �- --- + _ - + +� + _- PENCETREELINE - _ x - + + o- \IN 'HO3 SMG LEASING ASSOCIATES,. CP - m + + + D_ __ -_ - D.B. 1478, PG. 2186 r w�.N _. _ -- - - --------- STABILIZED — -- PIN 4755 87 5333 - � z,n o _ + + � C; m m M __- S CONSTRUCTION _6 STATESVILLE HMA 1INC + t + J \ ZONED RA _ � _ \ C32 D.B.�1221, PG. 373 I / _ - O ENTRANCE + + + r�47s5 7934+ + + �- � + + + ZONED 0+4- + + � S � �.. _ - - - - - - --O___:� Y + + + + _ P S -- / --- S+ — — z LIMITS OF CLEARING AREA = 2,18 ACRES GENERAL or ASor N TES 1. ALL EROSION CONTROL MEURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH NCDENR'S DESIGN MANUAL AND PRACTICES AND SHALL BE INSPECTED AND MAINTAINED ON A MONTHLY BASIS AND AS NEEDED FOLLOWING PEAK RAINFALL EVENTS. 2. THE SOIL TYPES ARE CmD2 (CECIL SANDY LOAM, 10-15%) AND CsE2 (CECIL SOILS, 15-25%) 3. THE SUBJECT PROJECT IS NOT LOCATED IN A PROTECTED WATERSHED DISTRICT. 4. TOPOGRAPHIC DATA WAS FIELD GATHERED BY G.L. WILSON BUILDING COMPANY ON APRIL 20, 2016, 5. EROSION CONTROL MEASURES ARE TO BE IN PLACE BEFORE LAND DISTURBING ACTIVITIES COMMENCE. 6. SEED ALL EXPOSED AREAS PER THE STABILIZATION TIMEFRAME TABLE BELOW. 7. CONCERNS WITH EROSION CONTROL ISSUES DURING CONSTRUCTION ARE TO BE DIRECTED TO: D. MARK TART, PE G. L. WILSON BUILDING CO. 190 WILSON PARK ROAD STATESVILLE INC 28677 PHONE: 704 872 2411 EXT. 247 + + + � s —+ + + v� I / — o + \+ ,. .• •- F • Y Q O QP U (Sr 0 0 - 1 O q o O o o f ��� TYP G\ +++ + O+\ ✓ / 11� 0000 O 0 0 0 q0 Q0 ! _ sF 00 00 000. 0 1 2 S KdS ;l > + + + + (p \+ sF / 00 '000000 0 1 -- - / / / + + + + + o+\ 00 00. 00 v,� + + + + + +r \} 0 0 0 ° 0 0 0 0 , ' 0 O �- �i9:°' — I - - Off' + + + + + + + \ + + + + + + + + +\ 4 0 0 0 � L__, _ .- I ;-: _ _- � sMc LE D6�246ASSOC 83TEs, cLe � + + +_ + + + + + \+ EROSION CONTROL SYMBOLS PIN 475E 6I 13 9 + + + + _+ + + + \ ZONED RA - � G4. _ I ' + + + + + + + + + +\ + TD -- STD -TEMPORARY DIVERSION n. / / r + + + + + + + + + + 0Ilk\ �bd £� „824.15 -SPOT ELEVATION + + + + + + + + + + \ + -FLOW DIRECTION INDICATOR + + + + +- _ +_ + + + + + + +\ + ORR -RIP RAP CHANNEL GL -GRASS LINED CHANNEL o \ + + ...+ + + + + + + + + + + + + + t \ �TSD -TEMPORARY SLOPE DRAIN + + + + + + + \ Hill -CATCH BASIN ' �kC I.. + + + + = + H- SF— -SILT FENCE < / + + + + + + + + + + +1 Z ++ F + + T -OUTLET PROTECTION + + +- - + + + + + + + -INLET PROTEC ON I I _ + u + -FLARED END SECTION . r r, + CONSTRUCTION SEQUENCE 1. MAINTAIN SILT FENCE, CONSTRUCTION ENTRANCE AND ALL SUCH OTHER SEDIMENTATI CONTROL DEVICES AS MAY BE USED ON THE SITE. 2. BEGIN CONSTRUCTION OF UNDERGROUND DETENTION SYSTEM AND STORM DRAINAGE SYSTEM. 3. INSTALL INLET PROTECTION AS STORM DRAINAGE STRUCTURES ARE COMPLETED, 4. CONSTRUCT CURB & GUTTER, SIDEWALK, AND OTHER HARDSCAPE. REPLACE HARDWAR CLOTH & GRAVEL INLET PROTECTION WITH STANDARD INLET SEDIMENTATION CONTROL DEVICES. 5. BACKFILL CURB & GUTTER 6. PERMANENT SEED AREAS PER STABILIZATION TIMEFRAME TABLE SHEET C3.2 7. REMOVE SILT FENCES AND OTHER SEDIMENTATION CONTROL DEVICES WHEN ALL DISTURBED AREAS OF THE SITE HAVE BEEN STABILIZED. G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625-8506 PHONE 704.872.2411 PAX 704.872.8281 ...L build@giwilwn.com Commercial and Industrial Construction Since 1945 `",nuilufif�. CARp'% /o. VT�_ = = �`4�D N 17365 :1Q A�ARK�P`i'\` llllllll,,,, 5/2/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUES/REVISIONS REV DATE DESCRIPTION BY 1 4/25/17 BASIN SIZE, ADD TSD @ TOE PSB ADD SILTSOXX 2 5/2117 APPROVED, IREDE-2017-078 PSB DESIGN NO.: 2016-075 DRAWN BY: PSB ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 EROSION CONTROL PLAN PHASE2 C301 c,ir y,T'-r. '? f 1 1 11 1 "I I 1 - -- - NEW STAMItZATI Nt TIUEFRAPAES Site Area Description Stabilisation Tlmetrar a Exceptions OPerimeter dikes, swales, ditches and slopes 7 days None Cw High Quality Water (HOW) Zones 7 days None L� Slopes steeper than 31 7 days If slopes are I V or less in length and are not steeper than 2.1, 14 days are allowed. p Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length. v All other areas with slopes flatter than 4:1 /4 days None, except for perimeters and HOW Zones. APPROVED BY IREDELL COUNTY 0 DEVELOPMENT SERVICES- PLANNING DIVISION - EROSION CONTROL SECTION MAY 2, 2017, PREOJECT ID IREDE-2017-078 OUTLET PROTECTION Q SEE EROSION CONTROL PLAN FOR LOCATION(S) 3do DIAMETER OF PIPE - do 2 DETAIL INFORMATION TAKEN FROM THE NORTH CAROLINA "EROSION AND SE C.4.0 CONTROL PLANNINGIMENT AND M COX FILTER Section A -A Hortn OR APPROVED EQUAL OUTLET ID. LENGTH (Ed) PIPE DI(ddoo)ER THICKNE SS (d) WIDTH AT OUTLa )(3 x WIDTH AT END (do + La) STONE REQDUIRE 18" FES 10 1.50 1.13 4.5000 11'-6" CLASS II ALL UNITS ARE IN FEET UNLESS OTHERWISE NOTED A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. PIPE OUTLET TO A FLAT AREA (NO WELL-DEFINED CHANNEL) SEEDING SPECIFICATIONS SEEDING INSTRUCTIONS rs TEMPORARY SEEDING 3:1 SLOPES OR FLATTER SEEDING MIXTURE: 1. APPLY AGRICULTURAL LIME AT THE RATE OF 90 lbs./1,000 S.F. SPECIES RATE (Ib\acre) 2. APPLY 10-10-10 COMMERCIAL FERTILIZER AT THE RATE OF 20 lbs./1,000 S.F. TALL FESCUE 60 LBS./AC. OR 1.5 LBS./1,000 S.F. 3. SEED IN ACCORDANCE WITH THE FOLLOWNG SCHEDULE AND APPLICATION RATES: BROWNTOP MILLET OR 35 LBS./AC. OR 3/4 LB./1,000 S.F. SORGHUM SUDAN HYBRIDS 30 LBS./AC. OR 3/4 LB./1,000 S.F. DATE TYPE PLANTING RATE SOIL AMENDMENTS: AUG. 15 - NOV. 1 TALL FESCUE 300 lbs./AC. OR 7 lbs./1,000 S.F. *NOV. 1 MARCH 1 TALL FESCUE 300 lbs./AC. OR 7 lbs./1,000 S.F. APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 Ib\acre GROUND AGRICULTURE LIMESTONE AND 1,000 Ib\acre ABRUZZI RYE 25 lbs./AC. OR .5 Ibs./1,000 S.F. 10-10-10 FERTILIZER. MARCH 1 - APRIL 15 TALL FESCUE 300 Ibs./AC. OR 7 lbs./1,000 S.F. MULCH: APRIL 15 - JULY 30 HULLED COMMON 30 Ibs./AC. OR 1 Ib./1,000 S.F. BERMUDA GRASS APPLY 4,000-5,000 Ib\acre GRAIN STRAW, OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR MULCH BY JULY 15 - AUGUST 15 TALL FESCUE AND 300 Ibs./AC. OR 7 Ibs./1,000 S.F. TACKING WITH ASPHALT, ROVING, OR NETTING. NETTING IS THE BROWNTOP MILLET 35 Ibs./AC. OR 7/8 Ib./1,000 S.F. PREFERRED ANCHORING METHOD ON STEEP SLOPES. OR SORGHUM SUDAN 30 Ibs./AC. OR 3/4 Ib./1,000 S.F. HYBRIDS 4. MULCH WITH STRAW APPLIED AT THE RATE OF 1.5 BALES/1,000 S.F. J� SEED ALL EXPOSED AREAS PER THE STABILIZATION TIMEFRAME TABLE ON j� THE EROSION CONTROL PLAN. * HEAVILY MULCHED DURING JANUARY-MARCH PERIOD. SLOPES GREATER THAT 3:1 TO 2:1 SLOPES PS PERMANENT SEEDING 1. APPLY AGRICULTURAL LIME AT THE RATE OF 90 Ibs./1,000 S.F. 2. APPLY 10-10-10 COMMERCIAL FERTILIZER AT THE RATE OF 20 Ibs./1,000 S.F. SEEDING MIXTURE: 3. SEED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE AND APPLICATION RATES: SPECIES RATE (Ib\acre) DATE TYPE PLANTING RATE TALL FESCUE 100 MARCH 1 - JUNE 1 SERICEA LESPEDEZA 50 Ibs./AC. OR 1.5 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 Ibs./1,000 S.F. SEEDING NOTES: MARCH - APRIL ADD TALL FESCUE 50 Ibs./AC. OR 3.5 Ibs./1,000 S.F. OR 1. IN EASTERN PIEDMONT ADD 25 Ib\acre PENSACOLA BAHIAGRASS MARCH - JUNE ADD WEEPING LOVEGRASS5 Ibs./AC. OR 1/8 D./1,000 S.F. OR 10 Ib\acre CCMMCN BERMUDAGRASS. USE COMMON BERMUDAGRASS ONLY WHERE IT IS UNLIKELY TO BECOME A PEST. JUNE - SEPTEMBER 1 TALL FESCUE AND 60 Ibs./AC, OR 1.5 Ibs./1,000 S.F. 2. AFTER AUG. 15 USE UNSCARIFIED SERICEA SEED. BROWNTOP MILLET 35 Ibs./AC. OR 3/4 Ibs./1,000 S.F. 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND OR SORGHUM SUDAN 30 Ibs./AC. OR 3/4 Ibs./1,000 S.F. SUBSTITUTE 40 Ib\acre BAHIAGRASS OR 15 Ib\acre BERMUDAGRASS. HYBRIDS 4. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 Ib\acre HULLED BERMUDAGRASS. HOWEVER, IT IS PREFERABLE TO SEED SEPTEMBER - MARCH 1 SERICEA LESPEDEZA 70 Ibs./AC. OR 3/4 Ibs./1,000 S.F. TEMPORARY COVED AND SEED FESCUE IN SEPT. (unhulled - unscarified) TALL FESCUE OR 150 Ibs./AC. OR 3.5 Ibs./1,000 S.F. NURSE PLANTS: MILLET OR SUDAN 20 Ibs./AC. OR 1/2 Ib./1,000 S.F, BETWEEN MAY 1 AND AUG. 15, ADD 10 Ib\acre GERMAN MILLET OR 15 SUDANRYE Ib\acre PRIOR TO MAY 1 OR AFTER AUG. 15, ADD ***TEMPORARY - RESEED SEPTEMBER 1 AT RECOMMENDED RATES. RYE,',RAIN). 40 Ib\acre N). 4. MULCH WITH 3" STRAW APPLIED AT THE RATE OF 50-90 Ibs./1,000 S,F, AND ANCHOR WITH SEEDING DATES: ASPHALT EMULSION TACK COAT APPLIED AT THE RATE OF 14-28 gals./1,000 S.F. OR 800-1200 gals./AC. BEST POSSIBLE FALL AUG. 25 - SEPT. 15 AUG. 20 - OCT. 25 SEED BED PREPARATION NOTES: LATE WINTER FEB. 15 - MAR. 21 FEB.1 - APR. 15 1. SURFACE WATER CONTOL MEASURES TO BE INSTALLED ACCORDING TO PLAN. FALL IS BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. DEEP. OVERSEEDING OF KOBE LESPEDEZA OVER FALL -SEEDED TALL FESCUE 2. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH AVAILABLE TOPSOIL 3" S VERY EFFECTIVE. USE UNHULLED BERMUDAGRASS SEED IN FALL. TOTAL SEEDBED PREPARATION DEPTH SHALL BE 4" TO 6" DEEP. SOIL AMENDMENTS: 3. LOOSE ROCKS, ROOTS, AND OTHER OBSTRUCTIONS SHALL BE REMOVED FROM THE SURFACE SO THAT THEY WILL NOT INTERFERE WITH ESTABLISHMENT AND MAINTENANCE OF VEGETATION. APPLY LIME AND FERTI_ ZER ACCORDING TO SOIL TESTS, OR APPLY SURFACE FOR FINAL SEEDBED PREPARATION, AT FINISH GRADES SHOWN, SHALL BE REASONABLY 4,000 Ib\acre GROUND AGRICULTURE LIMESTONE AND 1,000 Ib\acre SMOOTH AND UNIFORM. 10-10-10 FERTILIZER. 4. IF NO SOIL TEST IS TAKEN, FERTILIZE AND LIME TO BE ACCORDING TO SEEDING MULCH: SPECIFICATIONS ABOVE, IN ADDITION, PROVIDE 15 Ibs./1,000 S.F. OF SUPERPHOSPHATE. APPLY IE`. GRAIN STRAW, OR EQUIVALENT COVER 5. IF SOIL TEST IS TAKEN, PROVIDE LIME AND FERTILIZER ACCORDING TO SOIL TEST REPORT. UL OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR MULCH BY OTHER SUITABLE TACKING WITH ASPHAL`, ROVING, OR NETTING. NETTING IS THE 6. LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING PREFERRED ANC-ORING METHOD ON STEEP SLOPES. SEEDBED PREPARATION. MAINTENANCE: REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSA=". R=SEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMED'ATEL". WASHED STONE FVO� 31 D3 HARDWARE CLOTH & GRAVEL C3.2- INLET PROTECTION N.T.S. MAXIMUM POST CATCH BASIN SPACING OF 4' r4ow GALAVANIZED HARDWARE WIRE EXTENDS TO TOP OF BOX STANDARD METAL POST 2' IN GROUND #57 WASHED STONE PLACED AT A HEIGHT OF 16" MIN. ABOVE TOP SPACING OF 4' HLAN VILW MAXIMUM CONSTRUCTION SPECIFICATIONS: SECTION A -A 1, UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE - FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM O 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. MAINTENANCE: INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2" OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS 0 PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. \ \ \ o� CLASS B RIP RAP (SEE SECTION THIRD BASIN BELOW) / RIP RAAHEADWALL PIP #57 WASHED STONE. V-0" THICK x 3'-0" HIGH MINIMUM Notes: z! 1. GRAVEL & RIP RAP FILTER BERM BASIN DETAIL IS DESIGNED TO PROTECT EXISTING PIPE INVERTS THAT DRAIN 5 ACRES OR LESS. PFF'SF_= FIVE V EN 2. DIMENSIONS ARE MINIMUM ACCEPTABLE UNLESS / OTHERWISE NOTED. FLOOD STORAGE ZONE RIP RAP FI Olp �7y 3'� HEADWALL f- I I I NATURAL SEDIMENT I PIPE INVERT GROUND STORAGE 20 AREAS TO BE DISTURBED \\ � � (CUT, FILL, ETC.) 1.5 I' ,' - - CLASS 8 RIP -RAP MAXIMUM SEDIMENT DEPTI-- #57 WASHED STONE (CLEAN OUT POINT) T�V THRU sASN, FILTER AHD CU_VER_ PIPE 12 (PIPE INVERTS) C32 GRAVEL & RIP RAP FILTER BERM BASIN 5 STANDARD INLET SEDIMENT CONTROL DEVICE INSTAL_ TION DETAIL DUMP S-RAP 1" REBAR FOR BAG REMOVAL FORV NLE S=JIME N.T.S. DETAIL INFORMATION TAKEN FROM THE NORTH O STRAW WATTLE CHECK DAM CAROLINA "EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL". C3.2 INSTALL EVERY 50' OR AS XECESSARY WOODEN STAKE WITH WATTLE FILTER FABRIC ANCHORED TO THE TOP 1 12" DIAMETER STRAW FILLED WATTLE OR DITCH LINER / 12' DIAMETER STRAW FILLED WATTLE FASTENED TO WOODEN STAKE BY NAIL OR g STAPLE WOODEN STAKE PROFILE VIEW Ir DITCHLINE FILTER FABRIC �V OR DITCH LINER FLOW B" FABRIC STAPLE DUMP !APS 3AG LEIAL DITCHLINE O NOTES: ..' 1. WATTLES SHALL BE FILLED WITH STRAW OR OTHER APPROVED MATERIAL 2. SPACING FOR WATTLES SHALL BE 75' MAXIMUM. 3. WATTLES MAY BE USED FOR PROTECTION OF CATCH BASINS AND DROP INLETS WITH APPROVAL BY THE STORMWATER UTILITY MANAGER OR DESIGNEE. DETAIL INFORMATION TAKEN FROM SEDIMENT (JILT) FENCE __.O THE NORTH CAROLINA "EROSION AND SEDIMENT CONTROL PLANNING SEE EROSION CONTROL PLAN FOR LOCATION c32 AND DESIGN MANUAL". 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE --- 6' MAX. EXTRA STRENGTH UPSLOPE SIDE PLASTIC OR WIRE OF FENCE WIRE FENCE EXTEND FABRIC AND FILTER FABRIC WIRE INTO THE TRENCH 4" STEEL STAKE MIN. COMPACTED�SOIL' SECTION PERSPECTIVE CONSTRUCTION SPECIFICATIONS MATERIALS: 1, USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN THE "SPECIFICATIONS FOR SEDIMENT FENCE FABRIC" TABLE BELOW, SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLENT RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120' F. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.33 LB/LINEAR FT. STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. SPECIFICATIONS FOR SEDIMENT FENCE FABRIC TEMPORARY SILT FENCE MATERIAL PROPERTY REQUIREMENTS TEST MATERIAL UNITS SUPPORTED I UN-SUPPORTEDI TYPE OF GRAB STRENGTH ASTM D 4632 N (LBS.) SILT FENCE SILT FENCE VALUE MACHINE DIRECTION 400 550 MARV (90) (90) X-MACHINE DIRECTION 400 450 MARV (90) (90) PERMITIVITY ASTM D 4491 sec-1 0.05 0.05 MARV APPARENT OPENING SIZE 2 ASTM D 4751 mm 0.60 0.60 MAX. ARV 3 (US SIEVE #) (30) (30) ULTRAVIOLENT STABILITY ASTM D 4355 % RETAINED STRENWJ AFTER 500h OF70% AFTER 500h OF TYPICAL EXPOSURE EXPOSURE i SILT FENCE SUPPORT SHALL CONSIST OF 14 GAGE STEEL WIRE WTH A MESH SPACING OF 150 mm (6 INCHES), OR PREFABRICATED POLYMER MESH OF EQUIVALENT STRENGTH. 2THESE DEFAULT VALUES ARE BASED ON EMPIRICAL EVIDENCE WITH A VARIETY OF SEDIMENT. FOR ENVIRONMENTALLY SENSITIVE AREAS. A REVIEW OF PERVIOUS EXPERIENCE AND/OR SITE OR REGIONALLY SPECIFIC GEOTEXTILE TESTS IN ACCORDANCE WID TEST METHOD D 5141 SHOULD BE PERFORMED BY THE AGENCY TO CONFIRM SUITABILITY OF THESE REQUIREMENTS, 3A5 MEASURED IN ACCORDANCE NTH TEST METHOD D 4632. CONSTRUCTION: 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOTE EXCEED 24 INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UNSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM OF 50 LBS. TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6, EXTRA STRENGTH FILTER FABRIC W°1TH E =EET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIREC-_Y TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM OF 50 LBS. TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATE'_Y 4 `JCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER, 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9, BACKFILL THE TRENCH NTH SOIL 'LACE- OVER THE FILTER FABRIC AND COMPACT, THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FE%CE PF-ORMANCE. 10. DO NOT ATTACH FILTER FABRIC _J EXIS_NG TREES SEDIMENT (SILT) FENCE ROCK OUTLET c3.2 SEE EROSIC', CCJROL PLAN FOR LOCATION(S) SILT FENCE (BEYOND) 0 0� SECTION A -A A'_ n" nOFKIAI( SILT FENCE SEE DETAIL --\ STONE /- SILT FENCE SEE DFTAI I A --j ` #57 STONE PLACE ROC4 OU =TS IN LOW POINTS ALONG SILT FENCE TO =LEVEK OVER TOPPING OF SILT FENCE. OG AS INDICATED ON PLAN 1 1 10 20 40 .1 G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625A506 PHONE 704.872,2411 FAX 704.872.8281 EMAIL build@gWilson.com Commercial and Industrial Construction Since 1945 \L,1luunru„ CARP'%, Jp,1,. /_ 7.7 F-0267 0 SEAL E AT 1 3365 199 Ty CARD ,,, 4ARK IP�`°` 5/2/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NIC 28625 EROSION CONTROL DETAILS C302� I I SKIMMER BASIN C3.3 SEE EROSION CONTROL PLAN FOR SIZE AND SHAPE DETAIL INFORMATION TAKEN FROM THE NORTH CAROLINA "EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL". NOTE: Plan View THEM JORITY OF SEDIMENT WLL ACCUM JLATE IN THE FIRST BAY, SO THIS B Y SHOULD BE READILY ACCES IBLE FOR MAINTENANCE. Inflow structure i Average __ Area Width W L " Area of basin water surface at top of principal spillway elevation Baffles SEE SEDIMENT BASIN BAFFLES DETAIL 41 EMERGENCY PILL NOT USED. HRO PVC End OF OUTLET S RUC Cap TO SERVE A CY PILL PVC Tee Arm Assembly PERSPECTIVE VIEW PVC Elbow PVC End Cap Schedule 40 PVCPipe PVC Pipe g" Holes in Underside Flexible Hose 1-01 0 "C" Enclosure .. ater Entry Unit PVC Vent pipe Schedule 40 PVC Pipe PVC Tee Orifice Plate WIC Bottom END VIEW FRONT VIEW SKIMMER SHALL BE 2", WITH ORIFICE SIZE OF 1.25" SKIMMER DEWATERING DEVICE Sediment Cross -Section 7OF MERG CY SPILLWAY storage zone OT U ED. THROAT View OU ET STRUCTURE E AS BASIN PLAN AND SECTION EMERGENCY SPILLWAY GENERAL NOTES INSTALL SKIMMER SEDIMENT BASIN BEFORE ANY SITE GRADING TAKES PLACE WITHIN THE SKIMMER SEDIMENT BASIN'S DRAINAGE AREA. REFER TO EROSION CONTROL PLAN(S) FOR LOCATION(S) OF SKIMMER SEDIMENT BASIN(S). BASIN DEWATERING - THE BASIN SHOULD BE PROVIDED WITH A SURFACE OUTLET. A FLOATING SKIMMER SHOULD BE ATTACHED TO A SCHEDULE 40 PVC BARREL PIPE THROUGH THE DAM. THE ORIFICE OF THE SKIMMER WILL CONTROL THE RATE OF DEWATERING. BASIN SPILLWAY - CONSTRUCT THE ENTIRE FLOW AREA OF THE SPILLWAY IN UNDISTURBED SOIL IF POSSIBLE. EMBANKMENT - ENSURE THAT EMBANKMENTS FOR SKIMMER SEDIMENT BASINS DO NOT EXCEED 5 FEET IN HEIGHT (MEASURED AT THE CENTER LINE FROM THE ORIGINAL GROUND SURFACE TO THE TOP OF THE EMBANKMENT). KEEP THE CREST OF THE SPILLWAY OUTLET A MINIMUM OF 1.5 FEET BELOW THE TOP OF THE EMBANKMENT. ADDITIONAL FREEBOARD MAY BE ADDED TO THE EMBANKMENT HEIGHT WHICH ALLOWS FLOW THROUGH A DESIGNED BYPASS LOCATION. CONSTRUCT EMBANKMENTS WITH A MINIMUM TOP WIDTH OF 5 FEET AND SIDE SLOPES OF 2:1 OR FLATTER. MACHINE COMPACT THE EMBANKMENTS. EXCAVATION - WHERE SEDIMENT POOLS ARE FORMED OR ENLARGED BY EXCAVATION KEEP SIDE SLOPES 2:1 OF FLATTER FOR SAFETY. EROSION PROTECTION - STABILIZE ALL AREAS DISTURBED BY CONSTRUCTION (EXCEPT THE LOWER HALF OF THE SEDIMENT POOL) IMMEDIATELY AFTER COMPLETING THE BASIN. USE TEMPORARY SEEDING SPECIFICATIONS. MAINTENANCE INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (ONE-HALF INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY, REMOVE SEDIMENT AND RESTORE THE BASIN TO IT'S ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED, EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION IS GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL CAUSE THE SKIMMER TO BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBERS SNAKE OR BY FLUSHING WITH WATER. BE SURE TO REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. North Carolina One -Call Center 2a69 A. Nead"xviex Road, Suite 229 Greensboro, North Camline 29404 (910) M5-5760 2 LAYS BEFORE GIGGING IN NORRI CAROUNA CALL 1-800-632-4949 UNDERGROUND LOCATORS. CONTRACTOR SHALL CONTACT THE UNDERGROUND LOCATORS EVERY 10 DAYS FOR AN UPDATE TO UTILITY LOCATIONS. Call BEFORE you DIG! "It's The Law" CONSTRUCTION SPECIFICATIONS 1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS (SEE EROSION CONTROL PLAN) PREVENT THE SKIMMER DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY PVC SCHEDULE 40 PIPE) OF A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OF CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4 INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY OF THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTACT WITH IT'S FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS, OR AS DESIGNED. PROVIDE ADEQUATE FLEXIBLE HOSE TO ALLOW THE SKIMMER TO BE PULLED TO THE BANK FOR MAINTENANCE. 6, LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT, BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH 'LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENC-. THE EDGES MAY BE SECURED WITH 8 INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC S INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONS) SHOULD OVERLAP THE LOWER SECTION(S) SO THE WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A -RENCH WITH STAPLES OR PINS. 8. INLETS - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION, USE TEMPORARY S-OPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY. 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SJRFACE WATER FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. S_ABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF "JE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION. '0. INSTALL POROUS BAFFLES AS SPECIFIED (SEE "BAFFLE DETAIL") AFTER ALL THE SEDIMENT -PRODUCING AREA HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND S'ABI_IZE PROPERLY. APPROVED BY IREDELL COUNTY d DEVELOPMENT SERVICES- PLANNING DIVISION - EROSION CONTROL SECTION MAY 21 2017, PROJECT ID IREDE-2017-078 THROAT OF OUTLET STRCCTIRE TO f_ 51 SERVE AS EMERGENCY SP ILW4Y TOP OF DAM ELEV.= 868 50 SEE PLAN FOR POND SHAPE AND SIZE PRO'✓DED) VT WITH Q j////j//; -FAIRCLOTH SKIMMER - SEE EROSION CONTROL PLAN FOR ADDITOINAL INFORMATION " PROVIDED SED. BASIN STORAGE 865.M / < PROTECTION SEE PLAN INSTALL A MINIMUM OF (2) CONCRETE ANTI -SEEP COLLARS ALONG OUTLET PIPE. LOCATE COLLARS SLIGHTLY DOWJSTREAM FROM DAM CENTER -LINE. COLLARS SHALL PROJECT A MINIMUM OF 1.5 AROUND THE PIPE. SKIMMER BASIN SECTION NOT TO SCALE TRASH RACK WALL MOUNTED CLEATS FOR PERSONNEL ACCESS TO STRUCTURE. INSTALL CLEATS AT 12" O.C. TO WITHIN 24" OF STRUCTURE BOTTOM 1� 5" RCP BARREL INV. EL. = 862.90 DETAIL INFORMATION TAKEN FROM THE NORTH CAROLINA "EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL". eBAFFLE DETAIL C3.3 INSTALL IN TEMPORARY SEDIMENT TRAP(S), ROCK DAM(S), SKIMMER BASIN(S), OR SEDIMENT BASIN(S) 2 BAFFLES THAT DIVIDE THE BASIN INTO THIRDS. PLAN VIEW Support rope Support post, to wire to pre- 24"into bottom Stake to support vent sagging or side NOTEr,. z Gm urea Figure 6.65c Example M porous baffle using sat f m wiN slip cut in aeon aftema5ng space OfwaO baoldng fence. (City of High Point, NC tleWilJ CONSTRUCTION SPECIFICATIONS 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FROM FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL POSTS OR SAW HORSES ACROSS THE WIDTH OF THE SEDIMENT TRAP/BASIN. 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED A MAXIMUM OF 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6 INCHES HIGHER THAT THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAT THE TOP OF BERMS, SECTION 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISCHARGE POINT, BASINS LESS THAT 20 FEET IN LENGTH MAY USE 2 BAFFLES. GENERAL NOTES 5. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. 6. WRAP POROUS MATERIAL, UIJKE JUTE BACKED BY COIR MATERIAL, OVER A SAWHORSE OR THE TOP WIRE. HAMMER BAFFLES ARE POROUS BARRIERS INSTALLED INSIDE A TEMPORARY SEDIMENT TRAP, ROCK DAM, SKIMMER BASIN, OR REBAR INTO THE SAWHORSE LEGS FOR ANCHORING. THE FABRIC SHOULD HAVE 5 TO 10 PERCENT OPENINGS IN THE SEDIMENT BASIN TO REDUCE THE VELOCITY AND TURBULENCE OF THE WATER FLOWING THROUGH THE MEASURE. AND WEAVE, ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE OR STAPLES. FACILITATE THE SETTLING OF SEDIMENT FROM THE WATER BEFORE DISCHARGE. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8 INCH EROSION BAFFLES SHOULD BE USED IN ANY TEMPORARY SEDIMENT TRAP, ROCK DAM, SKIMMER BASIN, OR TEMPORARY CONTROL MATTING STAPLES. SEDIMENT BASIN. 8. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN. MAINTENANCE INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN OR TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DJRING CLEAN OUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE AND STABILIZE IT. DETAIL INFORMATION TAKEN FROM THE NORTH CARDLNA "EROSION s TEMPORARY SLOPE DRAIN AND SEDIMENT CONTROL PLANNING C3.3 AND ;--SIGN MANUAL". SEE EROSION CONTROL PLAN LOCATIONS) 41 S A oIONDSSPE�CIQFI RATLO o 1 DIVERSION DIKE 1 AON oPERR IN WELMPACTED FILL BEYOND z AT - CATIONS AND ELEVATION SHOWN ON PLANS. `k HOLD DOWN STAKES -' 2. SLIGHTLY SLOPE THE SECTION OF PIPE UNDER THE DIKE TOWARDS ITS _: 18" CORRUGATED PLASTIC PIPE (CPP) III 7111111,I ,�i (i� OUT-- % . ✓/ %/,/ 4' MIN. LEVEL STABILIZED OUTLET 7 - r- NOTE: IF RAIN IS EXPECTED. PLACE A 1 FT. LAYER OF STONE IN A SEMI -CIRCULAR CONFIGURATION AROUND EACH END OF CPP EXTENSION PIPE TO AID IN FILTRATION OF RUNOFF. C= OF STRUCTURE SASE EL. = 866.00 - 4'r=' PRECAST CONCRETE BASE �I T-611 TALL 4" PVC DRAIN INV. EL. = 863.25 � i - - � B_TTCM OF STRUCTURE SASE EL. = 862.50 BOTTOM OF 6'X WITH CONCRETE V -CONCRETE FOOTINC 1' DEPTH, 5.25' LENGTH, -.25' WUDTH TO CONTAIN 1.25 C.Y. OF \CRMAL WEIGHT CCNCRETE - ANCHOR _TLET STRUCTURE TO FOOTING SEE EROSION CONTROL PLAN FOR SIZE AND QUANTITY OF DRAIN PIPE REQ'D. TOP C- 4' MIN. HAND -COMPACTED SOIL NATURAL GROUND FILL (BLAND) z 1 C 5' MIN. DIVERSION g - - - CHANNEL \ �V�`�VfinV� T- SECTION FITTING CPP EXTENSION SECTION A -A 3. -AND TAMP THE SOIL UNDER AND AROUND THE ENTRANCE SECTION IN LIFTS NOT TO EXCEED 6 INCHES. 4. `+SURE THAT FILL OVER THE DRAIN AT THE TOP OF THE SLOPE HAS MINi."JM DIMENSIONS OF 1.5 FT. DEPTH, 4 FT. TOP WIDTH, AND 3:1 SIDE SLC=_S. 5. _NSURE THAT ALL DRAIN CONNECTIONS ARE WATERTIGHT. 6. =NSURE THAT ALL FILL MATERIAL IS WELL -COMPACTED. SECURELY FAS-EN THE EXPOSED SECTION OF THE DRAIN WITH GROMMETS OR STAKES SP=LED NO MORE THAN 10 FT. APART. 7. _XTEND THE DRAIN BEYOND THE TOE OF THE SLOPE AND ADEQUATELY PR -ECT THE OUTLET FROM EROSION. 8. MAKE THE SETTLED, COMPACTED DIKE RIDGE NO LESS THAT 1 FT. AS'.'E THE TOP OF THE PIPE AT EVERY POINT. 9. MMEDIATELY STABILIZE ALL DISTURBED AREAS FOLLOWING CC�STRUCTION, MAINTENANCE INSO-CT THE SLOPE DRAIN AND SUPPORTING DIVERSION AFTER EVERY RA'N=ALL AND PROMPTLY MAKE ANY NECESSARY REPAIRS. WHEN THE PR- -CTED AREA HAS BEEN PERMANENTLY STABILIZED, TEMPORARY MPSURES MAY BE REMOVED, MATERIALS DISPOSED OF PROPERLY, AND AL_ DISTURBED AREA STABILIZED APPROPRIATELY. 1.5" X 1.5" WOODEN STAKES PLACED 10' D.C. - 1.5" X 1.5" WOODEN STAKES PLACED 10' O.C. - COMPOST SOCK (9" or 12" TYPICAL) USE 12" DI G.L. WILSON BUILDING COMPANY 190 WILSON PARK ROAD: STATESVILLE, NC 28625-8506 PHONE 764.872.2411 FAX 704.872.8281 EMAIL buiid@glwllson.com Commercial and Industrial Construction Since 1945 �s°N BU14 ', .°�N CARD �i °RPOR,q p C' -= .. oFE S/pl,. - .� ° F-0267 SEAL 17365 L Q "' ftINf.�� 1996 rN cAR,,,MARKUP`,., "1111 n L11 \\" 5/2/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 ISSUES/REVISIONS REV DATE I DESCRIPTION BY 1 4/25/17 ADD SILTSOXX DETAIL PSB 2 5/2/17 APPROVED, IREDE-2017-078 PSB DESIGN NO.: 2016-075 DRAWN BY: PSB ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 EROSION CONTROL DETAILS UNDERDRAIN DETAIL NTS STORMTECH STORMTECH CHAMBER END CAP OUTLET MANIFOLD \\\\ FOUNDATION STONE BENEATH CHAMBERS - ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILO�ECTIONA-A L WALL ..,.... ..t FORATED E STORMTECHERDRAIN END CAPB FOUND"TI7�ABENEATHCHAMBEAADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-1601-P SYSTEMS SECTION B-B 6" (150 mm) TYP FOR SC-740, DC-780, MC-3500 & MC-4500 SYSTEMS SC-740 TECHNICAL SPECIFICATION NTS = LL U) O W U o I-- 90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH. U Z < w t i W "BUILD ROW tN THIS DIRECTION o- � o o O > W r @C�S4!r1T1k,S:9 'I3k)L1iY U) N r-. it �i- i- START END V 1 „ „• :. .. o w a - OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) ACCEPTS 4" (100 mm) SCH 40 PVC PIPE FOR INSPECTION PORT. FOR PIPE SIZES LARGER THAN 4" (100 MM) UP TO 10" (250 mm) USE INSERTA TEE CONNECTION CENTERED o ON A CHAMBER CREST CORRUGATION K i E o w o j o t (744 mm) f (762 mm) z i 12.2" I 51.0" 45c 5 310 +I �-- .9" (1166 mm) --� �--- --� ( MM) (129 5 MM) w I wm NOMINAL CHAMBER SPECIFICATIONS a SIZE (W X H X INSTALLED LENGTH) 51 0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm) ` CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m') v-• MINIMUM INSTALLED STORAGE` 74.9 CUBIC FEET 12.12 m') o z' WEIGHT 75.0 ibs. (33.6 k9) `ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS A A PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH 'T" PRE -CORED END CAPS END WITH "PC" B 1 C PART # STUB A B C SC740EPE06T / SC740EPE06TPC 6" (150 MM) 10.9" (277 mm) 18.5" (470 mm) --- SC740EPE06B I SC740EPE56BPC --- 05' (13 mm) SC740EPE08T ISC740EPEOBTPC 8" 1200 mm) 12.2" (310 mm) 16,5" 1419 mm) -- SC740EPE08B / SC740EPE08BPC --- 0.6" (15 MM) SC740EPEIOT I SC740EPE10TPOBC 10" (250 mm) 13.4" (340 mm) 14.5" (368 mm) --- SC740EPEIOBISC74CEPEtPC -- 0.7"(18 mm) SC740EPEI2T 1 SC740EPE12TPC 12" (300 mm) 14.7" (373 mm) 12.5" (318 mm) --- SC74DEPE12B I SC740EPE12BPC --- 1.2" (3O MM) SC740EPE15T I SC740EPE15TPC 15" (375 mm) 18.4" (467 mm) 9.0" (229 mm) -- SC740EPE15B/SC740EPE15BPC -- 1.3"(33 MM) SC740EPE18T/SC740EPE18TPC 18" (450 mm) i 19.7" (50O mm) 5.0"(127 mm) --- SC740EPE186 (SC740EPE18BPC _ 1.6" (41 mm) SC740EPE24B' 24" (600 mm) 18.5" (470 mm) __ 0.1" (3 mm) ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1-888-892-2694. ' FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm). BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL INTEGRATED DUCTILE IRON FRAME & GRATE/SOLID TO MATCH BASIN O.D. INVERTAC PLANSt VARIOUS TYPES C OUTLET ADAPTER, 4-30"(100- _- _ - _CORRU, WATER (CORRUGATED HI NYLOPLAST DRAIN BASIN NTS 7 mm) flDTH H-20 CONCRETE SLAB mm) MIN THICKNESS L n_AD._& CONCRETE DIMENSIONS GUIDELINE PUPOSES ONLY. CONCRETE SLAB MUST BE D GIVING CONSIDERATION FOR DIL CONDITIONS, TRAFFIC & OTHER APPLICABLE DESIGN i ANGLES VARIABLE 0"-360' ING TO PLANS VARIABLE SUMP DEPTH ACCORDING TO PLANS (6" (152 mm) MIN ON 8-24" (200-600 mm), 10" (254 inni) MIN ON 30" (7 50 mm)] mm) MIN ON 8-24" (200-600 mm) 152 mm) MIN ON 30" (750 mm) MATERIAL BELOW AND TO SIDES :TORE SHALL BE ASTM D2321 .�R II CRUSHED STONE OR GRAVEL AND BE PLACED UNIFORMLY IN 12" (305 mm) LIFTS AND COMPACTED TO MIN OF 90 NOTES 1. B-30" (200-750 mm) GRATESISOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2. 12-30" (300-750 MM) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3. DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS 4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SCR 35 PVC 5. FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM 6. TO ORDER CALL: 800-821-8710 A PART # GRATE/SOLID COVER OPTIONS 8" PEDESTRIAN LIGHT STANDARD LIGHT 2808AG SOLID LIGHT DUTY (200 mmj DUTY DUTY 10" PEDESTRIAN LIGHT STANDARD LIGHT (250 mm) 2810AG DUTY DUTY SOLID LIGHT DUTY 12 2812AG PEDESTRIAN STANDARD AASHTO SOLID (300 MM) AASHTO H-10 H-20 AASHTO H-20 151, 2815AG PEDESTRIAN STANDARD AASHTO SOLID (375 mm) AASHTO H-10 H-20 AASHTO H-20 18" PEDESTRIAN STANDARD AASHTO SOLID (450 mm) 2818AG AASHTO H-10 H-20 AASHTO H-20 24 PEDESTRIAN STANDARD AASHTO SOLID (600 MM) 2824AG AASHTO H-10 H-20 AASHTO H-20 30" PEDESTRIAN STANDARD AASHTO SOI ID (750 mm) I 2830A.G I AASHTO H-20 I H-20 I AASHTO H-20 .. 1 N N Q 0 00 p U o a zy _ a- ro as ow ❑: M o r z Q= 0 F< W °o °LL fQ oz � J V iw qn F Zv wi gc °w z_ 3m �z d E� SHEET 5 of 6 = LL U) Q V W F Q' Lu U 1. LU [L O >,` rY n Q CO i v O <'.n 1 1 10 20 40 61 G.L. WILSON BUILDING COMPANY 606 PHONE 704.87224 1R Fn ROAD:704.872.8281E EML LE build@glwilson.com @glwilson.com Commercial and Industrial Construction Since 1945 \�SON'B'u'/<o �N CARD .•�:17365 E 3i0 - � F-0267 � " _ SEAL 7996 TN CARD 'BARK ZV 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 -- - Y, . 1UL ISSUED DATE : 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 STORM WATER DETAILS C402 It CD �(�O O V V 7 N O V C7 co C�O� (�O 04 . �00 lLn.N N� 00 � + +t o°OD W aW aW W aW ¢W (n Lu r J f0 W to W -- I i fn W F to W CI) ss » ss aD_ aD_ (I EL as IL a. D_a as 7.52% 1 OO.00VC 5.13% 5.13% 155.48VC -8.00% -8.00% 900 - - 329.07SD 125.44SD 41.99K-Val 11.84K-Val 895 CREST STA.3+12.40 —— — — — — — _ CREST ELEV.894.85 _ 51 00 — — — 890 000 ^ 885 ssn 870 0+00 0+20 r to i m LO Lu (o W as 302.40VC 173.98SD 30.00K-Val cn n C) W r- LIJ to W as 302.40VC 473.98SD 30.00K-Val 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+60 2+80 3+00 3+20 3+40 3+60 3+80 4+00 4+20 4+40 4+60 4+80 5+00_ 5+20 5+40 5+60 5+80 6 t0 t0 Oh t0^ 00 NO1 OM N0) OIl, 00 OS O) ao ry moo 00 01 t0 iO 01 r� t0 00 LOW r: N M W) N ^ ^ r• N N ad0 ^m N^ ^M ^gyp NM ^0 t71to t7M to C a�i ao a0 00 0) a0 rn rn rn rn (AM rn 0 w 0) a0 00 0000 r- a0 r ao ao ao 00 00 co 00 ao a0 a0 a0 oo ao ao 00 co ao ao 0o ao OD O a pNj� C'j OON N '* N(D O) )°D 01 Cl) 00W cNi N 00 to �+ + °rD + co CID 00 �(. to Q W (n W (n W V) W (n W N W F- a- s ao_ as D_a amola 2.08% 2.08% 92.43VC 5.16°! 5.168o00Vd% - _ 257.22SD -625.50S) _ 90© 30.00K-Val 3.84K-Val SAG ELEV.878.49 895 890 i / 2Q°I° 516% 885 i M 875 TECHNICAL REVIEW COMMITTEE PLAN APPROVAL SIGNATURE BLOCK Planning Director Date P hlic {songs Director Date Electrical Utilities Director Date Pire Marshal Date - _ 870 60 5+80 6+00 6+20 6+40 6+60 6+80 7+00 7+20 7+40 7+60 7+80 8+00 8+20 8+40 8+60 8+80 9+00 9+20 9+40 9+60 9+80 Cl) Cl) CO LO m LO It .- 1O ao t0 t0 t0 t0 t0 Os Ot a7 N O �O r, M ry ^ 0f t0 ^ tO a0 iO M t0 M Y r` m N C) to m rn in m C6'i n^ n� anoa^o nn nDDo na0 00000 mm "'> M> `i> °D �; Cl) 0000 CD CO GOOD a'1 a0 a0 ao OD 00 a0 00 0000 F w v W J Lu n W F �Lu (n W U) JJ F (n W H Lu (n W 01 W (n W a0a 0-2-5 EL aaa (Laa 5(L 0.40% 40.0)VC -8,00% -8.008600VL08% 99.01SD - -28.85SB 4.761,-Val 0.79K-Val 900 900 0.40%'.. -- — -_ ----- — �--_ --- �------ CREST STA.3+23.26 � CREST ELEV.898.84 -00i 895 - 08% 895 SAG STA.3+95.60 SAG ELEV.894.83 890 - 890 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 i+0u 2+00 2+20 2+40 2+60 2+80 3+00 3+20 3+40 3+60 3+80 4+00 4+20 C cD Ln Ol L'J 1,- r') V 00 r� r C� 0l �D 0b Ll�O 10 "I Oi„1 (b r r M 00n 00 00 000 r-� N 07 00 DO M cc MM DO CC MU) CA 00 M0) cc � mCO M 00 cc cc CO G.L. WILSON l RU ILDING COMPANY !. 190 WILSON PARK ROAD: STATESVILLE, NO 28625-8506 PHONE 7G4.872.2411 FAx 704.872.8281 EMAIL build@glwilson.com Commercial and Industrial Construction Since 1945 S n ON a�i�o',, CARp' , °�PUrcg S� gyp. v ' 'U F-0267 S A I 17365 h1 LFHG1 tF �:• O� 7996 �\� � Q 'fC n��� rti cAR° ',,,MARK ZPR,�'. 4/19/17 THIS DRAWING IS THE PROPERTY OF THE CONTRACTOR. REPRODUCTION OR REUSE IN PART OR IN WHOLE, WITHOUT WRITTEN PERMISSION IS FORBIDDEN. © COPYRIGHT 2017 I ISSUED DATE: 3/27/17 A PROPOSED FACILITY FOR: SMG Leasing, LLC 142 Sherlock Drive Statesville, NC 28625 SITE PLAN PHASE 1 v