Loading...
HomeMy WebLinkAboutNCG030166_2021 DMR_20210914NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0166 Person Collecting Samples: Brice Fox Facility Name: Timken Co. Lincolntan Bearing Plant Laboratory Name: Pace Analytical Facility County: Lincoln Laboratory Cert. No.: 5342 Discharge during this period: Yes EINo cif no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Lj Yes allo If so, which Tier (I, ll, or Ill)? A copy of this DMR has been uploaded electronically via https:lLedocs-deg.nc.gov/Forms/SW-DMR + Yes LjNo Date Uploaded: 09/14/2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV N/A Date Sample Collected MM/DD/YYYY 08/15/2021 46529 24-Hour Rainfall in inches 3116" CO530 TSS in mg/L (100 or 50*) < 2.5mgll 00400 pH in standard units 16.0 — 9.0 FW, 6.2 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) < 0.005mgll Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) < 0.005mg11 Zinc, total recoverable in mg/ L 10.125 D1094 FW, 0.095 SW) <0.Oi0mgll Chemical Oxygen Demand (COD) in 00340 mg/L (120) < 25.Omg/l 00552 Non -Polar Oil & Grease in mg/L (15) < &0mgli * outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark T55 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including thepcysibilityof fines and imprisonment for knowing violations." Signature of Perf6ittee or Delegated Authorized Individual marty.hallman@timken.com Email Address 09/1412021 Date 704-736-2854 Phone Number