Loading...
HomeMy WebLinkAboutNCG030511_2021 DMR_20210908NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 • Metal Fabrication Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03511 Person Collecting Samples: Johnson, Mark Facility Name: Scott Safety Laboratory Name: Waypoint Analytical Facility County: Union Laboratory Cert. No. 402 Discharge during this period: Q Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Q Yes ❑ No If so, which Tier (1, 11, or III)? Tier I A copy of this DMR has been uploaded electronically via https:Iledocs.deq.nc.gov/Forms/SW-DMR Q Yes ❑ No Date Uploaded: Wednesday, September 8, 2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Code Parameter Outfall Outfall Outfall Outfall Outfall SDO-1 SDO-2 SDO-3 SDO-4 NA NA Receiving Stream Class C C C C NA NA Date Sample Collected MMIDDIYYYY 8/16/2021 8115/2021 8/16/2021 8/16/2021 NA 46529 24-Hour Rainfall in inches 0.40 in. 0.40 in. 0.40 in. 0.40 in. NA in. C0530 TSS in mg1L (100 or 50*) < 2.5 mglL < 2,5 mglL 44.0 mg1L 6.4 mg/L < mg1L 0400 pH in standard units (6.0 — 9.0) 5.99 *** 7.23 *** 6.82 *** 5.77 *** < *** 01119 Copper, total recoverable in mg1L (0.010) < 0,002 mg1L < 0,002 mg1L 0.003 mg1L < 0,002 mg1L < mglL 01051 Lead, total recoverable in mg/ L (0.075) < 0.001 mglL < 0.001 mg1L < 0.001 mglL < 0.001 mg1L < mglL 01094 Zinc, total recoverable in mgl L (0.126) < 0.020 mglL < 0.020 mglL < 0.020 mg/L < 0.020 mg1L < mglL 00340 Chemical Oxygen Demand (COD) in mglL (120) < 50 mg1L < 50 mglL < 50 mglL < 50 mg& < mglL 00552 Non -Polar Oil & Grease in mg/L (15) < 5.6 mg1L < 5.6 mg1L < 5.6 mg1L < 5.4 mg/L < mglL 78141 Total Toxic Organics (ii10) in rnglL (1) < 0.00 mg/L I < 0.00 mg/L 0.00 mg1L < 0.00 mg/L < mg1L * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters jr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mglL Notes INone. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for npwing viQlations." Paul Doron f/�fj�,(;Z-' Wednesday, September 8, 2021 Signature of Permittee or Delegated Authorized Individual Date Email Address paul.doron@mmm.com Phone Number (317) 332-9270