Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCC214247_MODIFICATION Supporting Doc LOT ADDED_20211005
u 5 DETAIL ® RFFFRFN(:F PLAN KEY NOTES Al 1O C5301 MAINTAIN TEMPORARY SILT FENCE (TYP.) A3 MAINTAIN TEMPORARY SILT FENCE C5301O STONE OUTLET (TYP.) C1 O MAINTAIN/INSTALL CHAIN -LINK C5301 TREE PROTECTION FENCE (TYP.) A5 MAINTAIN SILT BAG - DEWATERING C5301 O DEVICE (TYP.) B3 MAINTAIN STANDARD SILT SACK - INLET C5301O SEDIMENT CONTROL DEVICE (TYP.) B5 O MAINTAIN EROSION CONTROL C5301 MATTING (TYP.) A4 O TEMPORARY CONSTRUCTION ENTRANCE (TYP.) 7C5301 D3 TEMPORARY CONSTRUCTION C5301 O SIGN RAIN GAUGE LOCATION / C4 gO C5301 CONCRETE WASHOUT (TYP.) B4 10 MAINTAIN/INSTALL CHAIN -LINK C5301 FENCE (TYP.) 4 3 2 1 GROUND STABILIZATION REQUIREMENTS SEEDING SCHEDULE EROSION CONTROL NOTES PHASE 2 CONSTRUCTION MANAGEMENT NOTES (PER NPDES CONSTRUCTION STORMWATER GENERAL PERMIT NCGO10000) SEEDBED PREPARATION 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ORANGE COUNTY AND THE TOWN OF CHAPEL HILL 1. CONSTRUCTION SHALL COMPLY WITH THE CHAPEL HILL NOISE ORDINANCE, A2 11 TIRE WASH (TYP.) SITE AREA STABILIZATION STABILIZATION TIME 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER STANDARDS AND SPECIFICATIONS. ARTICLE 3, SECTION 11-40. 5302 ADVERSE SOIL CONDITIONS, IF APPLICABLE. DESCRIPTION TIME FRAME FRAME EXCEPTIONS 2. CONTRACTOR SHALL HAVE NORTH CAROLINA ONE CALL (1-800-632-4949). LOCATE ALL EXISTING UTILITIES 2. CONSTRUCTION HOURS SHALL BE FROM 7:00 AM - 7:00 PM ON WEEKDAYS 2. RIP THE ENTIRE AREA TO 6 INCHES DEEP. PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL VERIFY THE DEPTH AND LOCATION OF ALL EXISTING AND 8:00 AM - 7:00 PM ON WEEKENDS. THERE SHALL BE NO C3 MAINTAIN TEMPORARY INLET 12 •• PERIMETER DIKES, SWALES, 7 NONE UTILITIES AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES ON FEDERAL HOLIDAYS. 5301 PROTECTION (TYP.) DITCHES, AND SLOPES 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING . CONSTRUCTION SURFACE REASONABLY SMOOTH AND UNIFORM. 3. ALL CONSTRUCTION EQUIPMENT SHALL BE OPERATED IN ACCORDANCE WITH 3. THIS PLAN IS DIAGRAMMATIC AND REPRESENTS THE APPROXIMATE LOCATION OF UTILITIES UNLESS THE MANUFACTURER'S SPECIFICATIONS, AND WITH ALL STANDARD B2 i302 13 DIVERSION DITCH #1 •• HIGH QUALITY WATER (HQW) 7 NONE 4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY SPECIFICALLY DIMENSIONED. THE CONTRACTOR SHALL COORDINATE THE ACTUAL LOCATION OF UTILITIES TO EQUIPMENT, AND WITH MANUFACTURER'S MUFFLERS AND NOISE -REDUCING ZONES AND MIX WITH SOIL (SEE BELOW*). AVOID CONFLICTS AND MEET MINIMUM SIZE, SLOPE, AND CODE REQUIREMENTS. EQUIPMENT IN USE, AND IN PROPER OPERATING CONDITION. B2 4. TOTAL DISTURBED AREA: 2.13 AC. THIS INCLUDES ALL DISTURBANCE REQUIRED FOR FULL SITE CONSTRUCTION. 4. NO BLASTING OR BURNING ARE PERMITTED ON SITE. 14 DIVERSION DITCH #2 SLOPES STEEPER THAN 3:1 7 IF SLOPES ARE 10' OR LESS IN 5. CONTINUE TILLAGE UNTIL WELL PULVERIZED, FIRM, REASONABLY UNIFORM PHASE 1 DISTURBED AREA = 1.68 AC. AND PHASE 2 ADDITIONAL DISTURBED AREA = 0.45 AC. 5302 LENGTH AND ARE NOT STEEPER SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 5. A WATER TRUCK SHALL BE USED TO MINIMIZE DUST. Q4 THAN 2:1, 14 DAYS ARE 5. NO BURNING IS PERMITTED. B3 15 SILT FENCE J-HOOK ALLOWED 6. SEED ON FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULT) SEE AFTER SEEDING. 6. CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO PREVENT AND i302 (TYP.) 6. ALL EROSION CONTROL DEVICES, INCLUDING INLET PROTECTION, SHALL BE MAINTAINED AS NEEDED, AT LEAST REMOVE THE DEPOSIT OF SILT ON ADJACENT PAVED ROADWAYS. •• SLOPES 3:1 OR FLATTER 14 7 DAYS FOR SLOPES GREATER 7, MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. ONCE A WEEK AND AFTER EVERY RUNOFF PRODUCING RAINFALL EVENT TO ENSURE DEVICES ARE FUNCTIONING THAN 50 FEET IN LENGTH PROPERLY. 7. CONSTRUCTION WORKERS SHALL PARK WITHIN THE SITE - NO PARKING ON PUBLIC STREETS. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR 7. CONTRACTOR SHALL INSPECT THE EROSION AND SEDIMENT CONTROL DEVICES DAILY, MAKE ANY NECESSARY RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. iF STAND REPAIRS OR ADJUSTMENTS TO THE DEVICES, AND MAINTAIN INSPECTION LOGS DOCUMENTING THE DAILY 8. CONSTRUCTION VEHICLES TO ACCESS THE SITE FROM ACCESS DRIVEWAY •• ALL OTHER AREAS WITH 14 NONE SLOPES FLATTER THAN 4:1 SHOULD BE OVER 60H DAMAGED, REESTABLISH FOLLOWING ORIGINAL LIME, INSPECTIONS AND ANY NECESSARY REPAIRS. OFF ROSEMARY STREET. D (EXCEPT FOR PERIMETERS FERTILIZER AND SEEDING RATES. AND HQW ZONES) 8. CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO PREVENT AND REMOVE THE DEPOSIT OF SILT ON 9. EMERGENCY VEHICLE ACCESS SHALL BE MAINTAINED FROM ACCESS * APPLY' AGRICULTURAL LIMESTONE - 2 TONS/A(' (3 TOII IN CLAY SOILS) ADJACENT PAVED ROADWAYS W I wv3 I SMH cf) o NORTH ST ' OSSIBLE BURIEDLL 45' PUBLIC SS SS SS - / - RIM:447.6' G)Q JUNCTION BOX R/W 5��� (N)INV IN:441.5' w �S SS -SKS (1 61, PG 182) (S)INV IN: 441.5' S --(E)INV OUT:441.4' H - H OH CQH H,L4 0H �€ OH � 0 0 © I BRICK cn I T - - -4 POSSIBLE BURIED JUNCTION BOX %C I /� \ r"v r a \I C. I S T9C1 S 4 1 0 T4 3, I r � 100 432' I N E r 4a33; \\ 14 �E 4432, RiA, 2 G 450 INV sg8 r / OrN. UT4SS 7��_ PAGE BUILDING PARTNERSHIP LLC 4 PIDB 5761,4 , PG 278/ 71- T19` I L/ - PUMP -SEE CONSTRUCTION NOTE #11 AND "SILT BAG DEWATERING DEVICE" DETAIL J 17C? ON SHEET C5301 FOR C / -��7� DEWATERING SEQUENCE. cn cn / - - - - \ / BELL FAMILY PROPERTIES LLC 460 \ / / PINB#-9788=_'7-287-- 3 - 150, PG 204 EXI TING YZ" PIPE \ / / 9\ O--�/ 1� L C /4 ASPHALT III I-cn�►-�� o / / cn All CONCR ITE Z � / 46 0HU cn i __- -4I DMH RM: 467.0' INVIN: 463.9' INV OUT:463.8cn b9 _ I CENTURA BANK PIN# 9788-37-279L- / OH 1/ �079-PC 71 - cn - I BRICK RETAI ING W LL I 1.6 EST OF R - Z TOP OF ALL: 481.6' g - sMH C O O O O RIM: 474.4' Z INV OU T: 468.4' O I n 0 RESERVED co ASPHALT �� - FIRE LAN O All / BRICK RETAINING WALL 1.1' WEST OF R I TOP OF WALL:481.7' / I ' TRANSFORMER 1.2' DIAMETER ELECTRICAL BOX oil AT&T TELEPHONE PEDESTAL FERTILIZER - 1,000 LBS/ACRE - 10-10-10 SUPERPHOSPHATE - 500 DRIVEWAY OF ROSEMARY STEET. * "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON LBS/ACRE - 20% ANALYSIS MULCH - 2 TONS/ACRE - SMALL GRAIN STRAW 9. SUFFICIENT EROSION CONTROL PRACTICES MUST BE INSTALLED AND MAINTAINED TO RETAIN SEDIMENT WITHIN 10. NO MATERIAL SHALL BE STOCKPILED OR STORED ON OWASA WATER OR WEATHER OR OTHER SITE -SPECIFIC CONDITIONS THAT MAKE COMPLIANCE ANCHOR - ASPHALT EMULSION ® 300 GALS/ACRE THE BOUNDARIES OF DISTURBANCE. ALL DISTURBED AREAS SHALL BE NON EROSIVE AND STABLE AS SEWER EASEMENTS. IMPRACTICABLE" (SECTION ILB (2)(1 DESCRIBED IN THE GROUND STABILIZATION REQUIREMENTS TABLE (THIS SHEET). SHOULDERS, SIDE DITCHES. SLOPES (MAX, 3:1) PHASE 2 CONSTRUCTION SEQUENCE 11 USETO REASONABLER TS RLIGHOTRFROMLCO STRUOCTION-RELATED ACTIVITIES DO SIALLY THAT NOT SPILLURE OVER ONTO ADJACENT PARCELS. TYPE PLANTING RATE 1. MAINTAIN ALL PHASE 1 EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF CONSTRUCTION PER AUG 1 - NOV 1 TALL FESCUE 120 LBS/ACRE DETAILS AND NOTES ON SHEET C5301. 12. STAGING, PARKING, AND ANY OTHER CONSTRUCTION -RELATED ACTIVITIES NOV 1 MAR 1 TALL FESCUE 120 LBS/ACRE ARE PROHIBITED WITH THE RIGHT-OF-WAY WITHOUT EXPLICIT APPROVAL BY - 2. PER NPDES REQUIREMENTS, A RAIN GAUGE, SELF -INSPECTIONS RECORDS, PERMIT, CERTIFICATE OF COVERAGE, THE TOWN OF CHAPEL HILL AND THE NORTH CAROLINA DEPARTMENT OF & ABRUZZI RYE 25 LBS/ACRE AND S&E PLAN ARE REQUIRED TO BE MAINTAINED ON SITE AND ACCESSIBLE DURING INSPECTION. IT IS TRANSPORTATION. MAR 1 - APR 15 TALL FESCUE 120 LBS/ACRE RECOMMENDED THAT THESE ITEMS BE PLACED IN A PERMITS BOX AT THE BEGINNING OR ENTRANCE OF PROJECT. 13. DURING CONSTRUCTION, FIREFIGHTING VEHICLE ACCESS SHALL BE PROVIDED. APR 15 - JUN 30 HULLED COMMON BERMUDAGRASS 12 LBS/ACRE TEMPORARY STREET SIGNS SHALL BE INSTALLED AT EACH STREET JUL 1 - AUG 15 TALL FESCUE ARQ 60 LBS/ACRE 3. RELOCATE TEMPORARY CONSTRUCTION ENTRANCE. CHAIN LINK FENCE GATE, TEMPORARY CONSTRUCTION SIGN, INTERSECTION WHEN CONSTRUCTION ALLOWS THE PASSAGE OF VEHICLES. - CONCRETE WASHOUT AND TIRE WASH AREA. SIGNS SHALL BE OF AN APPROVED SIZE, WEATHER RESISTANT AND - ***BROWNTOWN MILLET 35 LBS/ACRE MAINTAINED UNTIL REPLACED BY PERMANENT SIGNS. NORTH ST R/W ***OR SORGHUM-SUDAN HYBRIDS 30 LBS/ACRE C4.NSTAL:CONS:TRUCT:IONEN:TRANCE OFF OF NORTH STREET. INSTALL TREE PROTECTION FENCE, SILT FENCE,47.5' FEENCE STONE OUTLETS AND CHAIN -LINK SECURITY FENCE ALONG ROSEMARY DECK 14. WHEN FIRE APPARATUS ACCESS ROADS OR A WATER SUPPLY FOR FIRE PUBLIC QILT 61, PG 182) ce eoc:441.7' SLOPES (3 1 TO 2 1) OAD PROTECTION ARE REQUIRED TO BE INSTALLED, SUCH PROTECTION SHALL BE INSTALLED AND MADE SERVICEABLE PRIOR TO AND DURING THE TIME OF � m V7 m co co m n � n 45F= v c� co r n - OF 6( ,a 178(8S�\ ,47 J, PG \ . 172, J PG 182 'L T 11 _IT. A MAR 1 -JUN 1 SERICEA LESPEDEZA (SCARIFIED) 50 LBS/ACRE 5. ANY WASTE OR EXCESS SOIL WILL BE TRUCKED AND HAULED OFF -SITE TO BE PROPERLY DISPOSED OF. CONSTRUCTION, EXCEPT WHEN APPROVED ALTERNATE MEANS OF FIRE PROTECTION ARE PROVIDED. 6. THE CONTRACTOR SHALL CONDUCT SELF -INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL _ & MEASURES AND COMPLETE THE FOLLOWING COMBINED SELF -INSPECTION FORM FOUND ON THE DEMLR WEBSITE 15. DURING DEMOLITION AND/OR CONSTRUCTION, ALL ASPECTS OF CHAPTER 14 445- (MAR 1 - APR 15) AM TALL FESCUE 60 LBS/ACRE (HTTP: //DEO.NC.GOV/ABOUT/DIVISIONS /ENERGY -MINERAL -LAND -RESOURCES/ OF THE NC FIRE PREVENTION SHALL BE FOLLOWED. THE OWNER/DEVELOPER (MAR 1 - JUN 30) OR AM WEEPING LOVEGRASS 5 LBS/ACRE EROSION-SEDIMENT-CONTROL/FORMS). COMPLETE INSPECTION FORMS SHALL BE KEPT ON -SITE AND AVAILABLE SHALL DESIGNATE ONE PERSON TO BE THE FIRE PREVENTION PROGRAM FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. SUPERINTENDENT WHO SHALL BE RESPONSIBLE FOR ENFORCING CHAPTER (MAR 1 - JUN 30) OR ADD HULLED COMMON BERMUDAGRASS 8 LBS/ACRE 14 OF THE NCFPC AND THE ON -SITE FIRE PREVENTION PROGRAM AND 7• SELF -INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE PERFORMED AT LEAST ENSURE THAT IT IS CARRIED OUT THROUGH COMPLETION OF THE PROJECT. APR 15 -JUN 30 HULLED COMMON BERMUDAGRASS 12 LBS/ACRE ONCE EVERY SEEN CALENDAR DAYS AND WITHIN 24 HOURS OF EVERY RAIN EVENT GREATER THAN 1INCH. 6 jl �� V JUN 1 - SEP 1 TALL FESCUE All 60 LBS/ACRE ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DESIGNED. ALL ESC 16. WATER SUPPLY FOR FIRE PROTECTION: WHEN REQUIRED. AN APPROVED RDMH M:442.7' / 48"Wx27"H STONE CULVERT / *** BROWNTOWN MILLET 35 LBS/ACRE MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED AT THE PROJECT SITE FOR MONITORING. WATER SUPPLY FOR FIRE PROTECTION, EITHER TEMPORARY OR PERMANENT, SHALL BE MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIAL ARRIVES 16 ***OR SORGHUM-SUDAN HYBRIDS 30 LBS/ACRE ON THE SITE. NCFC 1412.1. \ / 8. SEED ALL AREAS DISTURBED BY INSTALLATION OF ABOVE MEASURES IN ACCORDANCE WITH THE GROUND \ SEP 1 - MAR 1 SERICEA LESPEDEZA (UNHULLED - SCARIFIED) 70 LBS/ACRE STABILIZATION REQUIREMENTS TABLE LOCATED ON THIS SHEET. CALL NCDEQ DIVISION OF LAND QUALITY 17. IF THE LAYDOWN AREA IS NO LONGER BEING USED AS A STAGING AREA AT \ AND TALL FESCUE 50 LBS/ACRE RALEIGH REGIONAL OFFICE FOR INSPECTION AT (919) 791-4200. THE TIME OF CO, THEN ALL DISTURBED AREAS ARE TO BE SEEDED AND STABILIZED. \ \ (NOV 1 - MAR 1) AM ABRUZZI RYE 25 LBS/ACRE 9, UPON APPROVAL FROM NCDEQ DIVISION OF LAND QUALITY RALEIGH REGIONAL OFFICE & THE TOWN OF \ o CHAPEL HILL, BEGIN EXCAVATION FOR THE PROPOSED PARKING DECK ON THE WESTERN SIDE OF THE SITE 18. THE CONTRACTOR SHOULD CONTACT JERRY NEVILLE WITH THE TOWN'S \ I/ AND END ON THE EASTERN SIDE. EXISTING SEWER LINE AND EXISTING STORM LINE WILL BE REMOVED ONCE THE EXCAVATION PIT REACHES EACH LINE. TRAFFIC ENGINEERING DIVISION AT 919-969-5096 PRIOR TO ANY ROAD OR / SIDEWALK CLOSURE TO OBTAIN THE NECESSARY PERMIT APPROVAL. \ 10. IN -PLACE SHORING WILL BE USED TO EXCAVATE DOWN TO THE P1 LEVEL. STONE DECK PAD WHEN SUBGRADE \ / IS ESTABLISHED. C \ \ \I cn�/ / 13. IF THE SITE VROLGEROSION CONTROL DEVICES, REGRADE TO FINAL GRADE AS NEEDED, AND SEEDANYREMAINING DISTURBED AREAS. DRAWING LEGEND A5 EROSION CONTROL / / / I \ 14. WHEN VEGETATION IS ESTABLISHED, CALL FOR FINAL SITE INSPECTION. C1301 ENLARGEMENT #1 SYMBOL/ABBREVIATION \ / X / / 15. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. EXISTING PROPOSED DESCRIPTION 0' WIDE SANITARY .. .. ON M KIRK, ET AL CIDER 5 LLC SEWER EAS^E^M� �ENT �U1 ZEIA IAU HA hKA IEKNI Y / CAROLYN BAUC ¢\ PIN# 9788-37-4909 PIN# 9788-38-4062 PB 82, p6117B o {[ HOU G CORPORATION PIN# 9788-3 6019 DB 1155, PG 31 DB 6034, PG 471 / - II / - - PROPERTY LINE PI # 9788-38-5035 DB 2668, PG 576 PB 61, PG 182 [LOT 21 PB 62, PG 75 D B 82, PG 178 I o ��/ RAISED TOP ya / \ - - RIGHT-OF-WAY LINE ZZ TOP OF CSdIQCRETE:459.5' STONE �NING WALL SM LID TH KNESS:0.7' / / \ ADJOINER PROPERTY LINE RIM: 459. ' OF NG:2.4' X 0.45' 1.6' SOUTH OF IZ (A)I V I 0.4' / OF I � !$)I IN:45 .4' / OUT:458.2' / - \l(c)I V OUT:4 .2' / -� EASEMENT LINE POSSIBLE S JUNCTION / BOX PER P, PG 178 \ -ACE E ENCE FOUN� / - - SD SD STORM DRAIN LINE ST R? r JING *1 LL �V 64• 2i' E 3 J � X FENCE LINE TOP OF WALL�Q53.5'F�l C / SS SS �_.rS SS SS \ SS SANITARY SEWER LINE 9 2'X2' DI _ 1 \ \ 2 X 2 DI RIM: 444.3' 48"Wx27"H TONE CULV RT \ \ I \ BOTTOM: 44 .1' 1 20f1 \ � g{� / � / 0 2 15 121 I i_, u: ��1- L IN 1' ;�g�I SMALL RR SPIKE SET IN SOUTH SIDE OF A POWER POLE 'I III - NAVD • 8 VERTICAL DATUM ------- ----- ----- ---------�-= 1E� ---- --- -�- ,.,��... � .,.. _ _ o .,. �. . � 6 .� •n I JOE go ®■gym --- -------------- 0 � r�� -- - - - ;ems rTT�T�l��1P`t�li>ti.■zs:w�,o�ciraJr►�■■■■■i�■���I ��� - - - - i'� _ �// ,� ss P■� ■r II 1 �c� `R�. . ► . . . I) kmII / I I A5 EROSION CONTROL ENLARGEMENT #1 SCALE: 1 " = 10' 5 - � - � +ice ■ .��r-5m ��rJ t / . -,� �� ii�■-Ri 1�:�1a ,� - :EST.' �'_���_ 'j��es�+ -a. -..----- - - - - - 1;. s�ira�-�ou�u■ - -- - - C• 0011091IN Fig! ®o A• T .. :. ...... .. '.:1 ':, : ".. :. •r arovw LANDSCAPING `I X CONTRACTOR TO PROVIDE �I -ca - - - - - -ce - - - - - - - 1 a 2' x 3' H rBOX h� J jr PARKING FOR INSPECTORS D ARE eoc:4:464 o BOC:465.3' 1 A NV IN:464.2' INV OUT: CB DMH (BOLTED DOWN) 2.4' X FOR THE DURATION OF THE _E /DMH STORM Box CONSTRUCTION PROJECT n NV OUT:462.3' rn WATER METERS I "KNOX" BOX LOCATED ON I BOC:465.4' RIM:465.0' + RIM:465.6' � + � LOWER LEVEL FFE:457.26' CONSTRUCTION GATE FOR .NV OUT:47T. CONCRETE 2B FFE:463.18' [A]INV IN: 461.0' FIRE DEPARTMENT ACCESS. LT MPSTER AREA 30C: 471.5' LOWER LEVEL a [B]INV IN: 460.8' _ \ 30TTOM:464.2' [-]INV IN:460.2' BOC: :462 � -/�, I [D]INV IN: 460.2' INV IN: 462.4' \� ^ [E]INV OUT:460.1' INV OUT:461.4' x DMH +FFE:468.42' v RIM:466.9' 4 : ASPHALT RAMP INTO STREET LEVEL INV T.6' \ \ \ \ LAYDOWN AREA NV OUT: our62.s' _ IIDTH SIDEWALK EASEMENT A Do Z DMH DB 6227, PG 290 \ TOWN 0 LHAPEL HILL \ ' Z m 0RIM: 470.9' PIN# 918-37-5557 Z INV IN:465.0' TOWN OF C APEL HILL DB 1769 PG 442 ' (� o �, INV OUT:465.0' cu p PIN# 9788-37-4469 DB 1289, PG 442 PB' 6 4 AR 24 0.38 AC. :16 Q. / \ o � � N 'R8 \ � a c Q 11 0 4 \ ' (D 7 % CONSTRUCTION ° TRAILER AND ' ;AVATED o °- / INSPECTION BOX \ DROTECTION Co E LOCATION y} � \ ° . I VAD�� � TH METAL I 5' X 5' ? ELECTRIC TRANSFORMER \ \ BRKt S 65'07'03" W 42.24' PAY HERE SIGN!\� 0 KIOSKS N 25'05'28" W VARSITY ARCH 11.86 S 5' W 1 99' BANK OF \ ELECTRIC METERS, I KILL SWITCHES, \ m AND PANEL BOXES----V m 4 D +FFE: 456.29' r m L FRANKLIN OFFICE CHAPEL HILL LLC A o C PIN# 9788-37-7517 DB 6603, PG 282 AREA:28,836 SQ. FT. / 0.66 AC. 136 EAST ROSEMARY c LAYDOWN/STAGING AREA 0 - SEE CONSTRUCTION RIM :4 3M3' MANAGEMENT NOTE #17 INV IN: 466.8' m INV OUT:466.7' n I �C/) DMH RIM: 473.6' 2' X 3' DI INV IN(SE): 468.4' 4' X 5' RIM:474.1' INV IN(NE):468.3' ELECTRIC INV IN: 472.0' INV IN(S): 468.2' TRANSFORMER INV OUT:471.2' INV OUT:468.1' SMH GAS METER RIM: 471.7 SMH RIM- 472.6' 0 INV IN:469.5' BOTTOM OF INV OUT: 466.8' BOX: 467.1' Q G 3 I \ ME WITH ELECTRIC METER / CONCRETE RETAINING WALL CROSSING T_ _ TOP OF WALL:466.8' N / I IJ VARIABLE WIDTH SIDEWALK EASEMENT 5 DB 6227, PG 285 BRANCH BANKING AND TRUST CO SPIKE III LLC PIN# 9788-38-8082 PALIOURAS ENTERPRISES LLC PIN# 9788-37-9926 PIN# 9788-37-7911 DB 206, PG 486 I DB 3644, PG 292 I I DB 2570, PG 520 J CONCR TE RETAINING W ILL I 5 0. 7' W TOP OF W L:468.6' G LANDSCAPING LANDS.Q_APIN� ASPHALT SM RIM: 468. BRICK BRICK ANDSCAPING BRICK - IN INV IN: 463. T:462. [iN ' .0 RETE S1 SEW � tk - RaLK - ® BRICK BRICK - - BRICK I 1' X 1' ELECTRIC VAULTS - 8 VVSs 6' CI WjJ SS�10" DI SS SS 1p DI SS S (PS 71, PG 14) SS - 12 AC W W W w/ W ,.12„ AC W W - Fes- 0 L7�-J T - - .:N�64>(0:'S2, 353.r76 _ - LANDSCAPING/ MAPLE7 N 6 360.76' 2i LANDSCAPI G 3� LANDSCAPING 4Q \ -2' X 1' TRAFFIC VAULT UTILITIES IN THIS AREA SHOWN AS LOCATED BY KCI ASSOCIATES ON FEBRUARY 24, 2020 'LPAY KIOSKS SMH RIM: 478.1' INV IN(S): 470.7' INV IN(W):465.2' INV OUT:465.2' RALEIGH BOX +FFE:462.14' BOC: 472.7' INV IN:469.1' INV OUT:468.6' 1 E SS • • • • SMH RIM: 480.7' METER INV IN:464.8' r1" METER I INV OUT:464.7' SMH RIM: 47' ^' INV IN( SMH INV IN( RIM:479.4' INV IN: 464.8' INV Ol. INV OU T: 464.7' (INACCESSABLE INVERTS DERIVED FROM OWASA DATA) _ S--2- -470 © STREET LEVEL © 2' X 1' TRAFFIC VAULT LOWER LEA ELECTRIC CONTR THE TOWN OF CHAPEL HILL, NC (WALLACE PARKING DECK) DB 1269, PG 442 PIN 9788-37-9717 150 E. ROSEMARY ST. 64,719 SF = +/- 1.486 AC OLD AREA 50.617 SF = +/- 1.162 AC NEW AREA 2 S 64'50'53" S 64.50'56" 2' X +FFE: 461.64' ELECTRIC CONTROL PANEL RIM: 47 INV IN: 46 INV OUT: 46 UE UNDERGROUND ELECTRIC LINE OHU OVERHEAD ELECTRIC LINE G GAS LINE FO FIBER OPTIC LINE LIMITS OF DISTURBANCE TREE LINE -460_ MAJOR CONTOUR -462_ _-462 MINOR CONTOUR -460 PHASE 1 MAJOR CONTOUR (FOR REFERENCE ONLY) 462 PHASE 1 MINOR CONTOUR (FOR REFERENCE ONLY) - - DIVERSION DITCH LINE CONSTRUCTION ENTRANCE B SF SILT FENCE X CHAIN -LINK FENCE X CHAIN -LINK TREE PROTECTION FENCE SILT FENCE OUTLET SILT BAG o PUMP STANDARD SILT SACK `\ SILT FENCE J-HOOK BOREHOLE O EXISTING IRON PIPE SIGN CATCH BASIN ❑ DROP INLET D4 WATER VALVE FIRE HYDRANT �S SANITARY SEWER MANHOLE © SANITARY SEWER CLEANOUT POWER POLE LIGHT POLE E ELECTRIC BOX AC HVAC UNIT © GAS METER D4 GAS VALVE ® TELEPHONE VAULT FIBER OPTIC MARKER Q DECIDUOUS TREE CONIFEROUS TREE A EROSION CONTROL & CONSTRUCTION MANAGEMENT PLAN - PHASE 2 30 0 15 30 60 ( GRAPHIC SCALE IN FEET ) 1 inch = 30 ft. REVIEW DRAWING 1 NOT FOR CONSTRUCTION oLoco co z Q0 N I U z00 J w n„n I� Q j� < X:�J U tJ o O d Of co U O z v 1J w Ix rn N 04 COPYRIGHT • 2021 BALLENTINE ASSOCIATES, P.A. THIS DOCUMENT IS THE PROPERTY OF BALLENTINE ASSOCIATES, P.A. ALL RIGHTS RESERVED. ANY REPRODUCTION OF THIS DOCUMENT OR POSSESSION WITHOUT PRIOR PERMISSION OF BALLENTINE ASSOCIATES, P.A. WILL BE SUBJECT TO LEGAL ACTION. oc�`ce Assoc/ofes O A m CORPORATE F SEAL C328 P n/ CARS C'��tOr //i CL SEAL ��42r5p42 = �VIlk rr W C N Z N Q N a N CL cwn N V) N M N n Ln Z O (N w oc (/) w w W M 0 O U o w Z o w w z o W N � z m o W � � o U L3 o 0 WwW L) w Z� > LLI0r � N o_ N N Z w 0 w 0_ w 0_ w 0_ Z OWNER INFORMATION GRUBB PROPERTIES, INC 117 EDINBURGH SOUTH I SUITE 110 CARY, NC 27511 OWNERS REPRESENTATIVE: JOE DYE 919 388-5774 FAX 919 461-3939 JIVIAIL idye0grubbpmperties.com W N N N N N F- Z O 0_ S O< Q Q N (p N M M n - - N N - N w k � C_ (1) (U) U) Q c0J1 a C_ C_ wl o_ z N 0 W ? � 3 0 I- Z as = H a W LL1 o LLI W V� z v J ■ W _ J - a > I a cm o r � Z O cc N JOB #: 119016.02 DATE: 16 OCT 20 SCALE: AS NOTED DRAWN BY: J.B.M. REVIEWED BY: D.W.S. BIEET C1301