Loading...
HomeMy WebLinkAboutWQCS00067_Inspection_20211006ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Timothy Lawrence US MCAS Cherry Point MCAS Cherry Point Psc Box 8006 Havelock, NC 28533 NORTH CAROLINA Environmental Qualify October 06, 2021 SUBJECT: Compliance Inspection Report Cherry Point Collection System Collection System Permit No. WQCS00067 Craven County Dear Mr. Lawrence: The North Carolina Division of Water Resources conducted an inspection of the Cherry Point Collection System on 9/30/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Collection System Permit No. WQCS00067. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Robert Tankard with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at robert.tankard@ncdenr.gov. ATTACHMENTS Cc: Laserfiche Sincerely, Rottal Te.44441 Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Washington Regional Office 1943 Washington Square Mall I Washington, North Carolina 22889 252.946,6481 Compliance Inspection Report Permit: WQCS00067 Effective: 08/01/16 Expiration: 07/31/24 Owner : US MCAS Cherry Point SOC: Effective: Expiration: Facility: Cherry Point Collection System County: Craven Commanding General Environmental Affairs De Region: Washington Contact Person: Timothy Lawrence Directions to Facility: System Classifications: CS3, Primary ORC: Timothy Micheal Bert Secondary ORC(s): Brian Edward Maness Jeffery Allen Davis On -Site Representative(s): Related Permits: Title: Environmental Engineer Phone: 252-466-2754 Certification: 998176 Phone: 252-444-6409 1004232 991811 NC0003816 US MCAS Cherry Point - Cherry Point WWTP Inspection Date: 09/30/2021 Entry Time 10:OOAM Exit Time: 01:OOPM 252-466-2520 252-466-1229 Primary Inspector: Robert B Tankard Phone: 252-946-6481 Ext.233 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: ▪ Miscellaneous Questions ▪ Capital Improvement Plan ▪ Inspections ▪ Lines (See attachment summary) ▪ General ▪ Map ▪ Spill Response Plan ▪ Pump Stations ▪ Sewer & FOG Ordinances ▪ Reporting Requirements ▪ Spills Page 1 of 6 Permit: WQCS00067 Owner - Facility: US MCAS Cherry Point Inspection Date: 09/30/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: The inspection was on September 30, 2021. The attendees for USMC Cherry Point were:Timothy Lawremce, Rob Godwin, Brian Maness, Tim Bert, Ricky Bobby and Mike Bryant. The reivew of the paperwork was performed in the Water Plant conference Room. The operators prints off the work orders and keeps everything in order. A copy of the CIP was not available, but Mr. Timothy Lawrence said that the updated CIP was available. All records appeared to be in order. A site inspection of two high priority lines and four pump stations were performed. The high priority lines were the Mill Creek Crossing and the Hunter's Branch crossing. No issues were observed. The high priority lines are being inspected quarterly. Pump stations 3879, 1798, 3978 and 3981 were inspected. No issues were observed.PS 1798 was listed in the permit as a simplex pump serving multiple buildings. It has been upgraded as a duplex pump station. The facility was found to be in compliance. Page 2 of 6 Permit: WQCS00067 Owner - Facility: US MCAS Cherry Point Inspection Date: 09/30/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Is there a properly designated primary ORC and at least one back-up of proper grade? Are logs being reviewed by the system management or owner on a regular basis? # What is that frequency? # Are there any issues being addressed currently or any in the planning stages? Is there a specific pump failure plan available for all pump stations? Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? Are new/significantly upgraded pump stations equipped with anti -corrosion materials? Does the permittee have a copy of their permit? # Is permit expiring within the next 6 months? If Yes, has the Permittee applied for renewal? Comment: Sewer and FOG Ordinances Is Sewer Use Ordinance (SUO) or other Legal Authority available? Does it appear that the Sewer Use Ordinance is enforced? Is there a Grease Control Program that legally requires grease control devices? What is the standard grease trap cleaning requirement in the FOG ordinance? Is Grease Control Program enforced via periodic inspections/records review? Is action taken against violators? # Have satellite systems adopted an equivalent or more stringent ordinance? Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) Reminders are sent with an all hands on deck notification. Comment: Capital Improvement Plan Has a Capital (CIP) or System Improvement Plan been developed and adopted? Is it designated for wastewater only or does it have a dedicated section? Does CIP cover three to five year period of earmarked improvements? Does CIP include description of project area? Does CIP include description of existing facilities? Does CIP include known deficiencies? Does CIP include forecasted future needs? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Permittee acknowledge that a CIP had been accepted, however they did not have a hard copy at the location of the meeting. Page 3 of 6 Permit: WQCS00067 Owner - Facility: US MCAS Cherry Point Inspection Date: 09/30/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Map Is there a overall sewer system map? Does the map include: Pipe Type (GS/FM) Pipe sizes Pipe materials (PVC, DIP, etc) Pipe location Flow direction Approximate pipe age Pump station ID, location and capacity # Force main air release valve location & type # Location of satellite connections Is the map being updated for changes/additions within 1 year of activation? Comment: Reporting Requirements # Have there been any sewer spills in the past 3 years? If Yes, were they reported to the Division if meeting the reportable criteria? If applicable, is there documentation of press releases and public notices issued? Is an Annual Wastewater Performance Report being filed with the Division, if required? Is the report being made available to all its sewer customers? # How is it being made available? Comment: Inspections Are adequate maintenance records maintained? Are pump stations being inspected at the required frequency? # Is at least one complete functionality test conducted weekly per pump station? Is there a system or plan in place to observe the entire system annually? Is the annual inspection documented? # Does the system have any high -priority lines/locations? Are inspections of HPL documented at least every 6 months? Are new lines being added to the HPL list when found or created? Comment: Spill Response Action Plan Is a Spill Response Action Plan available? Is a Spill Response Action Plan available for all personnel? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 6 Permit: WQCS00067 Owner - Facility: US MCAS Cherry Point Inspection Date: 09/30/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: 24-hour contact numbers Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds Site sanitation and cleanup materials Post-overflow/spill assessment Does the Permittee appear to respond within 2 hours of first knowledge of a spill? Comment: • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Spills Yes No NA NE Is system free of known points of bypass? • ❑ ❑ ❑ If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? • El El El # Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ • ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ ❑ ❑ Comment: Very few reported spills. Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: Mill Creek crossing and Hunter's Branch crossing. USMC added an ariel line: C Street 14 feet of 8" ductile iron. Are right-of-ways/easements maintained for full width for access by staff/equipment? If No, give details on temporary access: Is maintenance documented? Are gravity sewer cleaning records available? Has at least 10% of lines older than 5 yrs been cleaned annually? Were all areas/lines inspected free of issues? Comment: Pump Stations Please list the Pump Stations Inspected: Pump Stations 3879, 1798, 3978 and 3981. # Number of duplex or larger pump stations in system # Number of vacuum stations in system # Number of simplex pump stations in system # Number of simplex pump stations in system serving more than one building Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE 70 0 11 0 Page 5 of 6 Permit: WQCS00067 Owner - Facility: US MCAS Cherry Point Inspection Date: 09/30/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? For pump stations inspected: Are they secure with restricted access? Were they free of by-pass structures/pipes? Were wet wells free of excessive grease/debris? # Do they all have telemetry installed? Is the communication system functional? Is a 24-hour notification sign posted ? Does the sign include: Owner Name? Pump station identifier? # Address? Instructions for notification? 24-hour emergency contact numbers? Are audio and visual alarms present? Are audio and visual alarms operable? # Is there a backup generator or bypass pump connected? If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Comment: 31 • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 6 of 6