Loading...
HomeMy WebLinkAboutNCG030704_CEI_20211005ROY COOPER Governor ELIZABETH S.;BISEP Secretary BRIAN WRENN Director NORTH CAROLINA Envlroamentn(Quaitty October 5, 2021 Dubose National Energy Services, Inc. Attn: Tim Shepard, Fabrication Division Manager 900 Industrial Drive Clinton, NC 28328 Subject: COMPLIANCE EVALUATION INSPECTION NPDES Stormwater General Permit NCG030000 Dubose National Services, Inc., #2, Certificate of Coverage NCG030704 Sampson County Dear Mr. Shepard: On September 29, 2021, a site inspection was conducted for the Dubose National Services, Inc. facility located at 307 Industrial Drive, Clinton, in Sampson County, North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Mr. Tom Wilson, Materials Manager and Ms. Tyler Miles, Environmental Compliance Manager were also present during the inspection and their time and assistance is greatly appreciated. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit NCG030000 under Certificate of Coverage NCG030704. Permit coverage authorizes the discharge of stormwater from the facility to receiving waters designated as Williams Old Mill Branch, class C, Sw waters in the Cape Fear River Basin. As a result of the inspection, the facility was found to be compliant with the conditions of the NCG030000 permit. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Please be advised that violations of the NPDES Stormwater General Permit are subject to a civil penalty assessment of up to $25,000 per day for each violation. If you or your staff have any questions, comments, or needs assistance with understanding any aspect of your permit, please contact me at (910) 433-3384 or via e-mail at melissa.joyner@ncdenr.gov. Sincerely, Melissa Joyner Environmental Specialist DEMLR Enclosure: Compliance Inspection Report ec: Tom Wilson, Materials Manager (via email) Tyler Miles, Environmental Compliance Manager (via email) DEMLR NPDES Stormwater Permit Laserfiche File cc: FRO — DEMLR, Stormwater Files North Carolina Department ofEmironmantalQuality Division of Energy, Mineral and Land Resources � E ���{ Fayetteville Regional Ogee 1 225 Green Street,. Suite 7141 Fayetteville, North Carolina. 28304 910,4333300 Compliance Inspection Report Permit: NCG030704 Effective: 07/01/21 Expiration: 06/30/26 Owner: DuBose National Energy Services Inc SOC: Effective: Expiration: Facility: Dubose National Energy Services Inc #2 County: Sampson 307 Industrial Dr Region: Fayetteville Clinton NC 28328 Contact Person: Tim Shepard Title: Fabrication Division Manager Phone: 910-590-2151 Ext.260 Directions to Facility: Traveling via 1-40 E, take exit 343 for US-701 toward Clinton, take the exit towards US-421 N/Dunn and turn right onto North Blvd, turn right onto Superior Drive in 0.4 mi, at the end of the road turn left onto Industrial Dr. facility on right. System Classifications: SWNC, Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Certification: Phone: Inspection Date: 09/29/2021 Entry Time 09:08AM Exit Time: 10:45AM Primary Inspector: Melissa A Joyner Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge CDC Facility Status: 0 Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 permit: NCG030704 Owner -Facility: Dubose National Energy Services Inc Inspection Date: 09/29/2021 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Melissa Joyner met with Mr. Tim Shepard, Fabrications Division Manager, Tom Wilson, Materials Manager and Ms. Tyler Miles, Environmental Compliance Manager at the Dubose National Energy Services, Inc., facility where she reviewed the Stormwater Pollution Prevention Plan (SWPPP). The SWPPP contained the information required by General Permit NCG030000. As a reminder, Analytical and Qualitative monitoring, as well as facility inspections are now required to be conducted quarterly per the schedules in the General Permit. except for the following information. It is recommended on the internal "Facility Inspections" form that verbiage be included about inspecting the ditches. The facility grounds were inspected including the outfalls and the best management practices. It is recommended maintenance be continued with sweeping up the dirt observed near a couple of drop inlets. Otherwise, all appeared to be good condition. Page 2 of 3 Permit: NCG030704 Owner -Facility: DuBose National Energy Services Inc Inspection Date: 09/29/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (LISGS) map? E ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? N ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? E ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? E ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? E ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? N ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? E ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ N ❑ # Has the facility evaluated all illicit (non stormwater) discharges? 0 ❑ ❑ ❑ Comment Page 3 of 3