HomeMy WebLinkAbout20211405 Ver 1_Meeting Request Review_20210920 tie R•.'.
DWR Pre-Filing Meeting Request Form
NORTH CAROLINA
EnWmnnacnlrtl Qua fay
ID#* 20211405 Version* 1
Regional Office* Central Office-(919)707-9000
Reviewer List* eads\rjconchilla
Pre-Filing Meeting Request submitted 9/20/2021
.........................................................................................................................................................................................................................................................................................................................................................................................................................................................
Contact Name* Jerry Parker
Contact Email Address* japarker3@ncdot.gov
Project Name* Coble Church Rd Bridge Replacement
Project Owner* NCDOT
Project County* Guilford
Owner Address: Street Address
1584 Yanceyville Street
Address Line 2
P.O. Box 14996
City State/Rovince/Region
Greensboro NC
Fbstal/Zip Code Country
27415 USA
Is this a transportation project?* 0• Yes r No
Type(s)of approval sought from the DWR:
fJ 401 Water Quality Certification- I— 401 Water Quality Certification-
Regular Express
I— Individual Permit I— Modification
I— Shoreline Stabilization
Does this project have an existing project ID#?*
(' Yes r No
Please list all existing project ID's associated with this projects.*
WBS Number 17BP.7.R.136
Do you know the name of the staff member you would like to request a meeting with?
Ryan Conchilla
Please give a brief project description below and include location information.*
State project 17BP.7.R.136 involves the replacement of the existing
NCDOT Bridge#400267 on SR 3336(Coble Church Road)over Climax
Creek. Bridge#400267 consists of 1 @32'-6"reinforced concrete deck
girders and abutments; reinforced concrete full height.The proposed
bridge consists of 1 @80'33"box beam with 4'-0"caps.The proposed
crossing is located in Zone AE of FIRM Map number 3710880000J and
was studied by Redelineated Study methods.Two stormwater outfalls are
proposed which will be placed at a distance to minimize disturbance to
adjacent stream and nearby buffers. Rip Rad pads will be utilized to
dissipate the energy. No deck drains are required for the proposed
bridge
Please attach the documentation you would like to have the meeting about.
Coble Church Rd Permit Drawings.pdf 2.46MB
pdf only
By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section
401 Certification Rule the following statements:
• This form completes the requirement of the Pre-Filing Meeting Request in the Clean Water Act Section 401 Certification
Rule.
• I understand by signing this form that I cannot submit my application until 30 calendar days after this pre-filing
meeting request.
• I also understand that DWR is not required to respond or grant the meeting request.
Your project's thirty-day clock started upon receipt of this application. You will receive notification regarding meeting location
and time if a meeting is necessary. You will receive notification when the thirty-day clock has expired,and you can submit an
application.
Signature ��
Submittal Date 9/20/2021
Reviewer Meeting Request Decision
Is a meeting required or is there more info needed?*
r Yes 6* No
If rrore infornnation is needed,please add cotrrrents for the enail notification below.