HomeMy WebLinkAboutNC0004618_Inspection_20130807NCDENR North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Programs Pat McMrory Thomas A. Reeder John E. Skvarla, III Governor Director Secretary August 7, 2013 Mark Cabral Alamac American Knits LLC P.O. Box 1347 Lumberton, NC.28359 SUBJECT: July 24, 2013 Compliance Evaluation Inspection Alamac American Knits LLC Alamac American Knit / Lumberton Permit No: NC0004618 Robeson County Dear Mr. Cabral: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on July 24, 2013. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0004618. The cooperation of Mr.. Cleve Collins, Grade IV ORC, was greatly appreciated. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. Mr. Collins and his staff do a great job at maintaining this facility. • Log books, maintenance records and log books appear to be well kept and up to date. • No transcription errors were found in the monthly discharge report for March 2013 when it was compared to laboratory bench sheets. Location: 225 Green Street, Suite 714, Fayetteville, NC 28301 Phone (910) 433-3300\FAX: 910-486-0707\Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Mr. Cabral Page 2 August 7, 2013 Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mark Brantley Environmental Senior Specialist Surface Water Protection Section Fayetteville Regional Office cc: Cleveland L Collins, ORC Central Files '" ayetteville.:Files United States Environmental Protection Agency PA Washington, D.C. 20460 Water Compliance InSpPf tinn'Repnrt FE OMB Ap2d40.. OMB No.2040 0057 Approval expires 8 31 98 Section A: National Data,System'Coding'(Le PCS) Transaction Code NPDES yr/mo/day Inspection 1 INI 2 15 I 31 NC0004618 111 121 13/07/24 117 Type Inspector Fac Type 18I C I . 19 LS I; 2911 I I I I I 1 1 I I`I I I I'I I I66 • Remarks" _ 211 I I I I I I I I I I I I I I I I I I I I I I I I I I I I li Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 , QA ---- --------------Reserved--------------- 67I 169 701 31 71 I N I 72I N I 73I I 174 751 1 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Alamac American Knit / Lumberton 1885 Alamac Rd Lumberton NC 28358 Entry Time/Date 09:20 AM 13/07/24 Permit Effective Date 09/10/01 Exit Time/Date 11:30 AM 13/07/24 Permit Expiration Date 14/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Cleveland L Collins/ORC/910-618-2456/ - Other Facility Data . Name, Address of Responsible OfficiallTitle/Phone and Fax Number Contacted Mark Cabral,PO Box 1347 Lumberton NC 28359//910-618-2235/9106182292 No Section C: Areas Evaluated During Inspection (Check only{hose areas evaluated) Permit ■ Flow Measurement • Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review • Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ • Akin 4g - 7- i3 Signature of Management Q A Reviewer - Agency/Office/Phone and Fax Numbers Date Belinda S Henson FRO WQ//910-433-3300 Ext.726/ 8"8" -!/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page.# NPDES yr/mo/day Inspection Type 31 NC0004618 111 121 13/07/24 117 181 CI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments Facility was clean and neat in appearance at the time of the inspection. Mr. Collins and his staff do a great job at maintaining this facility. Log books, maintenance records and log books appear to be well kept and up to date. No transcription errors were found in the monthly discharge report for March 2013 when it was compared to laboratory bench sheets. Page # 2 Permit: NC0004618 Owner - Facility: Alamac American Knit /. Lumberton. Inspection Date: 07/24/2013 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids,•pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis - Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to, users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE n n■n ■ nnn anon ■ nnn ■ nnn ■ n,nn ■ nnn ■ nnn ■ nnn ■ nnn ■ ■ ■ ■ ■ ■ nnn n n■n ❑ n■❑ ■ nnn ■ nnn ■ nnn ■ nnn Page # 3 Permit: NC0004618 Owner - Facility: Alamac American Knit / Lumberton Inspection Date: 07/24/2013 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Pump Station - Effluent Is the pump wet well free of bypass lines or structures? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/< of the sidewall depth) Comment: Aeration Basins Yes No NA NE nn■n Yes No NA NE ■ nnn ■ nnn ■ nnn nn■n Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn 00•0 nn■n Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nn-n ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE Page # 4 Permit: NC0004618 Owner - Facility: Alamac American Knit / Lumberton Inspection Date: 07/24/2013 Inspection Type: Compliance Evaluation Aeration Basins Yes No,, NA NE Mode of operation Ext. Air Type of aeration system Surface, Is the basin free of dead spots? ■ n n n Are surface aerators and mixers operational? ■ n ,n n Are the diffusers operational? n n ■ n Is the foam the proper color for the treatment process? ■ n n n Does the foam cover less than 25% of the basin's surface? • n n n Is the DO level acceptable? - ■ n n n Is the DO level acceptable?(1.0 to 3.0 mg/I) • n n n Comment: Pumps-RAS-WAS Yes No NA NE Are pumps in place? ■ n n n Are pumps operational? Al n n n Are there adequate spare parts and supplies on site? n ❑ n ■ Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ n n n Are all other parameters(excluding field parameters) performed by a certified lab? ■ n n n # Is the facility using a contract lab? ■ n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? • n n n Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? n n ■ n Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ■ n n n Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? n n ■ n Is sample collectedabove side streams? ■ n n n Is proper volume collected? • n n n Is the tubing clean? r ■ n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n Is sampling performed according to the permit? • n n n Page # 5 Permit: NC0004618 Owner - Facility: Alamac American Knit / Lumberton Inspection Date: 07/24/2013 Inspection Type: Compliance Evaluation Influent Sampling Yes No NA NE Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Upstream / Downstream Sampling Yes No NA NE nn■n ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ ❑ 0 0 Comment: Page # 6 Regional Inspectors' Checklist for Field Parameters Facility Name: Alamac Knits Regional Plant Inspector: Mark Brantley NPDES #: NC0004618 Regional Inspector Contact #: 910-433-3327 Field Lab Certification #: 144 Region: Fayetteville Lab Contact: Cleve Collins Date: July 24, 2013 I. Check the parameter(s) performed at this site for reporting purposes. ❑ Total Residual Chlorine (TRC) ® Temperature (TEMP) ® Specific Conductivity (SC) pH ®.Dissolved Oxygen (DO) ❑ Settleable Residue (SETT) II. General Laboratory (note any exceptions in section XI Are instruments, meters, probes, photometric cells, etc. maintained in good condition? A Yes ❑ No Are standards, reagents and consumables used within manufacturer expiration dates? [TRC gel standard is exempt.] Yes ❑ No r4refhetfdiiowingems docuinentedF(, rhe* applicable }� ,,_ ,,. 7t '_� _ Y _ item __ r r TG e`H a.,y. TEIIIIP D© S �rt`►ET` . . Date of sample collection* Time of sample collection* 4 4 4 4 Sample collector's initials or signature \I 4 4 __ 4 Date of sample analysis* 4 4 4 4 Time of sample analysis* q 4 4 4 Analyst initials or signature 4 4 4 4 Sample location q 4 4 4 *Date and time of sample collection and analysis may be the same for in situ or on -site measurements. . 7atal.Residual- Moil i e , .,. _ . 7 z t:5 = Total Residual Chlorine meter make and model: Is a check standard analyzed each day of use? (Circle one: gel or liquid standard) Yes No What is .the assigned/observed value of the daily check standard? Is a 5-point calibration verification performed? Note date of last verification: Yes No Yes No - Alternatively, does the lab construct a linear regression, using 5 standards, to calculate results? Note date of last calibration curve constructed: True values: ❑ pg/L ❑ mg/L , Obtained values: ❑ pg/L ❑ mg/L What program are samples analyzed on? Yes No Are results reported in proper units? Check one: ❑ pg/L ❑ mg/L Are results reported between the facility's permit limit and the compliance limit of 50 pg/L? If value is Tess than the low standard, report as "<x", where x=low standard conc. Yes No Are samples analyzed within 15 minutes of collection? Yes No 2I ` '. ' ■ _".r 1 u h ^5 y i, 3{ ._ �..._ - pH meter make and model: Accumet Model 10 pH meter Is the pH meter calibrated with at least 2 buffers per mfg's instructions each day of use? Note buffers used: Yes ❑ No Is the pH meter calibration checked with an additional buffer each day of use? Note check buffer used: Yes ❑ No Does the check buffer read within ±0.1 S.U. of the known value? /1 Yes ❑ No Are the following items documented:• Meter calibration? ►1 Yes ❑ No Check buffer reading? ,I Yes ❑ No Are samples analyzed within 15 minutes of collection? Yes ❑ No Are sample results reported to 0.1 pH units? 1 Yes ❑ No V :Temperature - s What instrument(s) is used to measure temperature? Check all that apply:❑ pH meter YSI 54A a DO meter ❑ Conductivity meter ❑ Digital thermometer ❑ Glass thermometer Is the instrument/thermometer calibration checked at least annually against a NIST traceable or NIST certified thermometer? _ Yes ❑ No Are temperature corrections (even if zero) posted on the instrument/thermometer? /1 Yes ❑ No Are samples measured in situ or on -site? [REQUIRED - there is no holding time for temperature] ►1 Yes ❑ No Are sample results reported in degrees C? Yes ❑ No ' 11i_ Dissolved OxY9en _ _ - .--- - '_.. .... x ... . _. .. ,..... --{. DO meter make and model: YSI 54A Is the air calibration of the DO meter performed each day of use? I Yes ❑ No Are the following items documented: Meter calibration? r Yes ❑ No Are samples analyzed within 15 minutes of collection? /1 Yes ❑ No Are results reported in mg/L? ►1 Yes ❑ No a/11 Oonduc#14ty _ , ^ _ Conductivity meter make and model: Orion Model 160 Is the meter calibrated daily according to the manufacturer's instructions? Note standard used (this is generally a one -point calibration): 4 Yes ❑ No Is a daily check standard analyzed? Note value: /1 Yes ❑ No Are the following items documented: Meter calibration? /1 Yes ❑ No Are samples analyzed within 28 days of collection? /1 Yes ❑ No Are results reported in pmhos/cm (some meters display equivalent pS/cm units)? A Yes ❑ No 1:V111 } , r Settleable, Residue t - t �-_ : = , Does the laboratory have an Imhoff Cone in good condition? Yes No Yes No Is the sample settled for 1 hour? Is the sample agitated after 45 minutes? Yes No Are the followingitems documented: Volume of sample analyzed? Note volume analyzed: Yes No Date and time of sample analysis (settling start time)? • Yes No Yes No Yes No Yes No Yes No Time of agitation after 45 minutes of settling? Sample analysis completion (settling end time)? Are samples analyzed within 48 hours of collection? Are results reported in ml/L? I- _ t Was a paperYtra l (compari g contractilab-and on- ite data to 2-- ipe formed? Ifso hst monthsreviewad. March; 201 � - _ X: u" is follow up`by the.Laboratory Certification program reco timended? Yes~ 61 _No XI. Additional comments: Please submit a copy of this completed form to the Laboratory Certification program at: DWQ Lab Certification, Chemistry Lab, Courier # 52-01-01 Electronic copies may be emailed to linda.chavisncdenr.qov. Revision 04/20/2012