SUBJECT: Compliance Inspection Report
1083 Reems Creek Road
NPDES WW Permit No. NCG551604
Buncombe County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the 1083 Reems Creek
Road on 6/24/2021. This inspection was conducted to verify that the facility is operating in compliance
with the conditions and limitations specified in NPDES WW Permit No. NCG551604. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required.
If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at
stephanie.williams@ncdenr.gov.
Sincerely,
Stephanie Williams, Environmental Specialist
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS: Inspection Report
Ec: Laserfiche
DocuSign Envelope ID: 8B1F1927-62EB-4BD0-B3B5-5D17415C9AFF
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NCG551604 21/06/24 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
1083 Reems Creek Road
1083 Reems Creek Rd
Weaverville NC 28787
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
09:00AM 21/06/24 21/06/23
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
09:30AM 21/06/24 25/10/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Asia Guyer,1083 Reems Creek Rd Weaverville NC 28787///Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenance Self-Monitoring Program Facility Site ReviewPermit
Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Stephanie A Williams DWR/ARO WQ/828-296-4500/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: 8B1F1927-62EB-4BD0-B3B5-5D17415C9AFF
6/28/2021
6/28/2021
NPDES yr/mo/day
21/06/24
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Stephanie Williams, with the Asheville Regional Office, conducted a Compliance Evaluation Inspection
of the single-family wastewater disposal system that services 1083 Reems Creek Road to determine if
it is being operated and maintained in compliance with General NPDES Permit No. NCG550000. Ms.
Asia Guyer was present during the inspection. The system appears to be operational and well
maintained.
The system is inspected and maintained twice per year by Water Management of Lenoir, North
Carolina.
The pumps were operational at the time of inspection; however, the floats were not manually tested
as the chamber was bolted down. The chlorination and de-chlorination tubes had an appropriate
number of tablets. Ms. Guyer said they regularly check the chambers and refill the tablets as needed.
Ms. Guyer turned the pump on in order to observe the system discharging during the inspection.
NCG551604 17 (Cont.)
Page#2
DocuSign Envelope ID: 8B1F1927-62EB-4BD0-B3B5-5D17415C9AFF
Permit:NCG551604
Inspection Date:06/24/2021
Owner - Facility:
Inspection Type:
1083 Reems Creek Road
Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
The Certificate of Coverage took effect 06/23/2021.Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
The septic tank was pumped 07/26/2019.Comment:
Sand Filters (Low rate)Yes No NA NE
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re-circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1)
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?2
Page#3
DocuSign Envelope ID: 8B1F1927-62EB-4BD0-B3B5-5D17415C9AFF
Permit:NCG551604
Inspection Date:06/24/2021
Owner - Facility:
Inspection Type:
1083 Reems Creek Road
Compliance Evaluation
Disinfection-Tablet Yes No NA NE
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
Comment:
De-chlorination Yes No NA NE
Type of system ?Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Are tablet de-chlorinators operational?
Number of tubes in use?2
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: