Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction
1 IN I
21 1 1 1
Code NPDES yr/mo/day Inspection
2 IL I 3 I NC0023540 111 121 21/09/15 117
Type
181l I
I I 1 1 1
Inspector Fac Type
191 S I 2011
1 1 1 1 1 1 11 1 1 1 I I 1 1 1 1 1 1 1 I I I I I
1 11
1 1 1 I 1 P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 I 70I3 I 71IN I 72 I N I 73I I 74 71
I I 1
I I I I I I Il80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES Dermit Number)
Belmont Textile Machinery WWTP
1212 W Catawba Ave
Mount Holly NC 28120
Entry Time/Date
09:30AM 21/09/15
Permit Effective Date
20/07/01
Exit Time/Date
11:30AM 21/09/15
Permit Expiration Date
25/02/28
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Joseph R. Cote/ORC/704-827-5836/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Walter P Rhyne,PO Box 568 Mount Holly NC 281200568//704-827-5836/7048278551
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and
Ori A Tuvia
Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
Date
9/23/2021
,-DocuSigned by:
DWR/MRO WQ/704-663-1699/ _ I
\-- BB057A2DE017498__
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
9/23/2021
�A14CC681AF27425...
Page# 1
NPDES yr/mo/day
31 NC0023540 111 121 21/09/15
I17
Inspection Type
18i i
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0023540
Inspection Date: 09/15/2021
Owner - Facility: Belmont Textile Machinery WWTP
Inspection Type: Compliance Sampling
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑
application?
Is the facility as described in the permit? • El El El
# Are there any special conditions for the permit? El • El El
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • El El El
Comment: The subject permit expires on 2/28/2025.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ • ❑ ❑
• ❑ ❑ ❑
•
• ❑ ❑ ❑
• ❑ • ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The records reviewed during the inspection were well maintained and organized.
DMRs, COCs, calibration logs and ORC logs were reviewed for the period April 2021
through June 2021. Some of the field data taken did not match the EDMR, ORC will
revise EDMR.
Page# 3
Permit: NC0023540
Inspection Date: 09/15/2021
Owner - Facility: Belmont Textile Machinery WWTP
Inspection Type: Compliance Sampling
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
Comment: On -site field analyses (pH, total residual chlorine, temperature) are performed under
the facility's field laboratory certification # 5479. K&W Labs (Certification #559) has
also been contracted to provide analytical support
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ❑ El • El
Is sample collected below all treatment units? • LI El El
Is proper volume collected? • ❑ ❑ ❑
Is the tubing clean? ❑ El • ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 El El • El
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • El El El
representative)?
Comment: The subject permit requires effluent grab samples.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ • ❑ El
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable DOME
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The facility appeared to be adequately treating the wastewater at the time of the
inspection. However, at the time of the inspection the facility showed signs of aging and
is in need maintenance. The bar screen appeared too coarse and insufficient to catch
the debris of the influent flow. Rags, paper products and other debris were observed in
downstream treatment units. A settleability test of solids at the time of the inspection
was very low settling in the 10% range after 15 minutes. Slow settling may be an
indication of insufficient wasting. At the time of the inspection, only one of the two
blowers was working the other was out of service earlier that week. It was observed that
the skimmers in the clarifier were not removing the floating solids sufficiently and the
clarifier had floating solids. At the time of the inspection, the wasting pump was not
working. Advanced signs of rusting were clearly visible in the digester and adjacent
wet well.
Bar Screens Yes No NA NE
Page# 4
Permit: NC0023540
Inspection Date: 09/15/2021
Owner - Facility: Belmont Textile Machinery WWTP
Inspection Type: Compliance Sampling
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Yes No NA NE
•
❑ • ❑ ❑
• ❑ ❑ ❑
Comment: The bar screen appeared too coarse and insufficient to catch the debris of the influent
flow. Rags, paper products and other debris were observed in downstream treatment
units.
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots? • ❑ ❑ ❑
Are surface aerators and mixers operational? ■ ❑ ❑ ❑
Are the diffusers operational? ❑ ❑ • ❑
Is the foam the proper color for the treatment process? • ❑ ❑ ❑
Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑
Is the DO level acceptable? ❑ ❑ ❑ •
Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ ❑ ❑ •
Comment: Dog food is added as a food supplement five days per week (at a minimum) due to the
low influent flows/loading. The facility is equipped with two blower/motor units, however,
one of the blowers was not working at the time of the inspection.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
❑ • ❑ ❑
Page# 5
Permit: NC0023540
Inspection Date: 09/15/2021
Owner - Facility: Belmont Textile Machinery WWTP
Inspection Type: Compliance Sampling
Secondary Clarifier Yes No NA NE
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment: At the time of the inspection, the skimmers in the clarifier were not removing the
floating solids sufficiently and the clarifier had floating solids and scum.
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ El El
Are the tablets the proper size and type? • El El El
Number of tubes in use? 1
Is the level of chlorine residual acceptable? • El El El
Is the contact chamber free of growth, or sludge buildup? • El El El
Is there chlorine residual prior to de -chlorination? • El El El
Comment:
De -chlorination Yes No NA NE
Type of system ? Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)? • ❑ ❑ ❑
Is storage appropriate for cylinders? El El • El
# Is de -chlorination substance stored away from chlorine containers? El • El El
Are the tablets the proper size and type? • El El El
Comment: The chlorination and dechlorination tablets are stored inside the industrial facility.
Are tablet de -chlorinators operational? • El El El
Number of tubes in use? 1
Comment: The chlorinated wastewater is pumped through the dechlor tablet unit prior to the
effluent pumping area.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: Instantaneous flows are measured by a dose counter (150 gallons per dose).
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
Page# 6
Permit: NC0023540
Inspection Date: 09/15/2021
Owner - Facility: Belmont Textile Machinery WWTP
Inspection Type: Compliance Sampling
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Yes No NA NE
Page# 7