Loading...
HomeMy WebLinkAboutNCG551405_Inspection_20210621DocuSign Envelope ID: AF5215A9-35CC-44E0-AE17-4112C9BAA52B United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL I 21IIIIII IIIIIIIIIIIIIIIIII NPDES yr/mo/day Inspection 3 I NCG551405 111 121 21/05/25 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 I IIIIII P6 Inspection Work Days 671 I Facility Self -Monitoring Evaluation Rating B1 QA Reserved 70I I 711 1 72 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 2157 Pisgah Highway 2157 Pisgah Hwy Biltmore Lake NC 28715 Entry Time/Date 11:30AM 21/05/25 Permit Effective Date 13/08/01 Exit Time/Date 12:30PM 21/05/25 Permit Expiration Date 18/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Dan R O'Kelley,2157 Pisgah Hwy Candler NC 287159770//828-252-2799/ Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Linda S Wiggs of Inspector(s) DS F/30DWR/ARO Agency/Office/Phone and Fax Numbers Date WQ/828-296-4500 Ext.4653/ Signature of Management Q A Reviewer DS Agency/Office/Phone and Fax Numbers iM Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 DocuSign Envelope ID: AF5215A9-35CC-44E0-AE17-4112C9BAA52B 3I NPDES yr/mo/day N CG551405 111 121 21/05/25 I17 Inspection Type 18LI (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Inspector, Linda Wiggs, met with the Owner, Dan O'Kelley. Mr. O'Kelley has the septic tanked pumped annually. The effluent pipe was observed, but not discharging. We turned on the pumps that deliver wastewater to the sandfilter in an effort to generate a discharge, however no discharge was observed. Ms. Wiggs informed Mr. O'Kelley that he could sample from his contact chamber if needed, in order to meet the annual sampling requirement. The samples obtained by Mr. O'Kelley were compliant with permit limits. Mr. O'Kelley keeps a logbook with good notation. Page# 2 DocuSign Envelope ID: AF5215A9-35CC-44E0-AE17-4112C9BAA52B Permit: NCG551405 Inspection Date: 05/25/2021 Owner - Facility: 2157 Pisgah Highway Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑ application? Is the facility as described in the permit? El El • El # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? • ❑ ❑ ❑ Is septic tank pumped on a schedule? • ❑ ❑ ❑ Are pumps or syphons operating properly? • El ❑ ❑ Are high and low water alarms operating properly? • ❑ ❑ ❑ Comment: The Septic Tank is pumped annually. The tank also has a filter for added measure. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Is the wet well free of excessive grease? • ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are float controls operable? • ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ • ❑ Is audible and visual alarm available and operational? • ❑ ❑ ❑ Comment: Sand Filters (Low rate) (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Yes No NA NE Page# 3 DocuSign Envelope ID: AF5215A9-35CC-44E0-AE17-4112C9BAA52B Permit: NCG551405 Inspection Date: 05/25/2021 Owner - Facility: 2157 Pisgah Highway Inspection Type: Compliance Evaluation Sand Filters (Low rate) Yes No NA NE Is sand filter free of ponding? Is the sand filter effluent re -circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) Comment: • ❑ ❑ ❑ ❑ ❑ • ❑ Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? • ❑ ❑ ❑ Are the tablets the proper size and type? • ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ • Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ • Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? ❑ ❑ • ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ • ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: Page# 4