HomeMy WebLinkAboutNC0020656_NPDES Permit Renewal_20090311DIVISION OF WATER QUALITY
March 11, 2009
MEMORANDUM
TO: Dina Sprinkle
Point Source Branch
FROM: Dale Lopez, Environmental Specialist
THROUGH: Belinda S. Henson, Regional Supervisor Surface Wate; Protective. Section, FRO
SUBJECT: Application for NPDES Permit NC0020656
Laurinburg (Leith Creek) Wastewater Treatment Plant
POBox249
Laurinburg, NC 28379
Scotland County
Please fmd enclosed a staff report and recommendations from the Fayetteville Regional
Office concerning the application for a new NPDES Permit.
If you have any questions or require any further information, please advise.
/DL
Enclosures
DIVISION OF WATER QUALITY
March 11, 2009
MEMORANDUM
TO: Dina Sprinkle
Point Source Branch
FROM: Dale Lopez, Environmental Specialist
THROUGH: Belinda S. Henson, Regional Supervisor Surface Wate.. Protection. Section, FRO
SUBJECT: Application for NPDES Permit NC0020656
Laurinburg (Leith Creek) Wastewater Treatment Plant
PO Box 249
Laurinburg, NC 28379
Scotland County
Please find enclosed a staff report and recommendations from the Fayetteville Regional
Office concerning the application for a new NPDES Permit.
If you have any questions or require any further information, please advise.
/DL
Enclosures
To: Permit and Engineering Unit
Water Quality Section
Attention: Dina Sprinkle
Date: March 11, 2009
NPDES STAFF REPORT AND RECOMMENDATION
COUNTY: Scotland
Permit No.: NC0020656
PART 1— GENERAL INFORMATION
1. Facility and Address: Laurinburg (Leith Creek) Wastewater Treatment Plant
PO Box 249
Laurinburg, NC 28356
2. Date of Investigation: February 18, 2009
3. Report Prepared by: Dale Lopez,. Environmental Specialist FRO
4. Person Contacted and Telephone Number:
Robert Ellis (910) 277-0214
5. Directions to Site:
From Fayetteville, travel on Hwy 95 South, pass through Lumberton, then turn right on
Exit 14 (Hwy 74). Turn right, then an immediate left onto Business Hwy 74. Travel
approximately two miles and turn left onto Hall Street, travel approximately one mile and
turn left onto E. Covington Street. Go straight onto Read Street. The Laurinburg Leith
Creek Wastewater Treatment Plant will be at the end of the street and on the left.
6. Discharge Point(s), List for all discharge points:
FLatitude: 34°45'00" N Longitude: 79°27'45" W
Attach a U.S.G.S. map extract and indicate the treatment facility site and the discharge point on
the map.
U.S.G.S. Quad No.
U.S.G.S. Quad Name:
H 21 SW
Laurinburg, N.C.
7. Site size and expansion area consistent with the application?
Yes.
8. Topography (relationship to the flood plain):
9. Location of the nearest dwelling:
Not evaluated
Not evaluated
10. Receiving stream or affected surface waters:
a. Classification:
Lumber River Index Number 14-34 Classification C, Sw
b. River Basin No. Lumber River 03-07-55 and Sub basin No.:
c. Describe receiving stream features and the pertinent downstream uses:
ILUM55
The discharge from the Laurinburg wastewater treatment facility flows to Big
Shoe Heel Creek, at a point with a 7Q10 of 13.8 cfs flow (as according to the
Whole Effluent Toxicity Testing Self -Monitoring Summary --- see attachment).
It is classified as Class C, Sw waters, which promotes aquatic life propagation and
survival, fishing, wildlife, secondary recreation, and agriculture.
PART II - DISCRIPTION OF WASTES AND TREATMENT WORKS
1. a. Volume of wastewater to be peiinitted:
(Ultimate Design Capacity)
b. What is the current peiuutted capacity of the Wastewater Treatment facility?
4.0 MGD
4.0 MGD
c. Actualtreatment capacity of the current facility (current design capacity)?
4.0 MGD
d. Please provide a description of the existing or substantially constructed
wastewater treatment facility:
The Laurinburg WWTP is a 4 MGD wastewater treatment facility consisting of
mechanical bar screen, mechanical grit removal, influent Parshall Flume and ultrasonic
flow monitoring device, aerated equalization basin (E.Q. basin), influent pump station
(overflow from the influent pump station goes to the E.Q. pump station, and then to a six
million gallon Equalization Basin with six floating aerators), flow splitter box divides
flow equally between dual 1-MGD extended aeration basins (both aeration basins with
secondary clarification), a 2-MGD oxidation ditch with secondary clarification, dual
chlorine contact basin using bleach disinfectant, dechlorination, effluent force main
pumps treated wastewater approximately one mile to the effluent Parshall Flume
(equipped with ultrasonic flow monitoring device), cascade step aeration, and discharge
of treated wastewater into Big Shoe Heel Creek (Lumber River Basin) Sludge is treated
in two aerobic digesters and sludge drying beds, then land applied at the Laurinburg
Maxton Airport Commission land application site with Land Application of Residuals
Permit Number WQ0002526.
e. Possible toxic impacts to the surface waters:
None
2. Residuals handling and utilizing/disposal scheme:
a. If residuals are being land applied, please specify the DWQ Peu iiit No.
WQ0002526
Residual Contractor:
Telephone:
b. Residual stabilization:
c. Landfill.
e.
N/A
N/A
N/A
Other disposal/utilization scheme (specify):
N/A
3. Treatment plant classification (attach completed rating sheet):
4. Alternative Analysis Evaluation:
Has the facility evaluated all of the non -discharge options available? Please provide the
regional perspective for each of the options that were evaluated.
Connection to Regional Sewer System:
Land Application:
Water Reuse:
none evaluated
none evaluated
none evaluated
PART IV — EVALUATION AND RECOMMENDATIONS
1. The applicant is not requesting modification of the facility or increasing flow at this time.
2. A review of the compliance data did not reveal any significant violations.
3. Based upon the previous Compliance Evaluation Inspection (CEI) that was conducted on
February 18, 2009, all units were in service, and this facility continues to comply with the
requirements of the NPDES permit for wastewater treatment.'
4. This Office recommends continuation of the Special Conditions for the Whole Effluent
Toxicity monitoring.
5. This Office recommends that a formal Sludge Management Plan be included as a
requirement in the NPDES Permit and that it will be updated as needed and as
determined by the Division of Water Quality.
6. Based upon the above information, this Office recommends reissuance of the said permit
for the continued operation of an existing 4.0 MGD wastewater treatment facility
consisting of an influent pump station, mechanical bar screen, grit chamber, influent flow
monitoring, aerated equalization basin, flow splitter box, dual one million gallon per day
extended aeration basins with secondary clarification, chlorine contact chamber,
dechlorination, effluent force main, cascade aeration, and two aerobic sludge digesters,
and drying beds located at the Laurinburg Leith Creek Wastewater Treatment plant,
southeast of the City of Laurinburg, in Scotland County.
� o
NC EN .
. North Carolina Department of Environment and Natural Resources.
Division of Water Quality
Beverly.Eaves Perdue Coleen H. Sullins
Governor Director
February 20, 2009
Robert Ellis, Treatment Plants Director
City of Laurinburg
P.O. Box 249
Laurinburg, NC 28379
Subject: Compliance Evaluation Inspection
City of Laurinburg Wastewater Treatment Plant
NPDES Permit No. NC0020656
Scotland County
Dear Mr. Ellis:
Dee Freeman
Secretary
Enclosed you will find a copy of the Compliance Evaluation Inspection report for
the inspection that was conducted on February 18, 2009. As part of the inspection a tour
of the Wastewater Treatment Plant was conducted. All observations and recommendations
are in Part D: Summary of Findings/Comments of this inspection report.
. On the day of this inspection, a sludge spill that was contained on site occurred near
the small sludge holding tank. Verbal plans were to put the sludge back into the nearby
manhole that flowed to the aeration basin, clean the ground area, and apply lime to the
contaminated ground area. The sludge spill may have occurred as a result of approaching
the capacity of the sludge holding tanks, and it may follow that the sludge capacity for the
wastewater treatment plant may be inadequate because .of the following: 1) the .sludge
holding tanks were approaching capacity, and 2) the clarifiers had sludge blankets that
were approximately 10 feet in depth (with a clarifier sidewall depth of 13 feet): Please
send this office a written Plan -of Action, due by March 24, 2009, concerning how to
reduce the sludge in the holding tanks and clarifiers, and avoid a sludge spill. Please also
send a written report of the status of the February 18th sludge spill clean up.
225 Green St., Suite 714, Fayetteville, NC 28301-5043
Phone: 910-433-33001 FAX: 910-486-0707 \ Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
An Equal Opportunity i AYrmalive Action Employer
One.
Carolina
Naturally
Mr. Ellis
Page 2
February 20, 2009
We appreciate the time and professional courtesy that was extended by you and-,
. your staff during the inspection. If you have any questions or comments concerning this
report, please contact me at (910) 433.-3312.
Sincerely,
Dale Lopez
Environmental Specialist
/dl
Enclosures: EPA Water Compliance Inspection Report
Regional Field Inspectors Check List for Field Parameters
Schematic of WWTP
cc: Central Files
Fayetteville Regional Office Files
Ricky Odum, City of Laurinburg, (Backup-ORC)
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES ' yr/mo/day Inspection
1 I NI 2 1 51 31 1400020656 111 121 09/02/18 1 17
Type Inspector Fac Type
181 ci 191 s1 201 11
1 111 11111'1166
Remarks
211111111111111111111111111111 11111111
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 2.0• 169 70I 31 711 1 721 N I 73I 1 174 751 1 1 1 1 I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Leith Creek WWTP
Hall St Extension
Laurinburg NC 28352
Entry Time/Date
10:30 AM 09/02/18
Permit Effective Date
04/11/01
Exit Time/Date
02:00 PM 09/02/18
Permit Expiration Date
09/08/31 •
Name(s) of Onsite Representative(s)/fitles(s)/Phone and Fax Number(s)
///
Robert A. Ellis/ORC/910-277-0214/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Robert A. Ellis,P0 Box 249 Laurinburg NC 28353//910-277-0214/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Waters
as necessary)
Permit ;. Flow Measurement Operations & Maintenance %'_ Records/Reports
. Handling •
2Self-Monitorin9 Program"SludgeDisposal'` Facility Site Review h < Effluent/Receiving
Laboratory
Section D: Summary of Findinq/Comments (Attach additional sheets of narrative and checklists
(See attachment summary)
Name(s�� d3lgnatu`e(s) of Inspector(s) Agency/Office/Phone and.Fax Numbers i Date
Dale Lopez`,, P i" FRO WQ//910-433-3300 Ext.712/ f/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
NPDES
NC0020656
111 121
yr/mo/day
09/02/18
Inspection Type
17 18I C
(cont.) 1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On the day of this inspection, a spill'of sludge occurred near the small sludge holding tank. The spill was
contained on site. Verbal plans were to put the sludge .into the nearby manhole that flows to the aeration
basin, and the ground area cleaned up and lime applied to the area. It appeared that there was inadequate
sludge_ capacity, because the sludge holding tanks were nearcapacity and the clarifiers had sludge blankets
that were approximately.10 feet in depth (with a clarifier sidewall depth of 13 feet). In addition, a sludge •
spill occurred on the day of this inspection that may be related to the depth of the sludge in the sludge
holding tanks. .Please send this office awritten Plan -of -Action, due by March 24,.2009, concerning how to
reduce the sludge in the sludge holding tanks and clarifiers, and avoid a sludge spill. Please also send a
written report of the status of the February 18th sludge spill clean up. Please begin testing and recording
the amount of chlorine, sampled immediately before dechlorination in the chlorine contact chamber. Please
note that the flow paced 24-hour effluent composite sampler was set to.pull 150 rnL of sample for each
100,000 gallons of effluent flow (the frequency of grab samples that make up the composite appeared to be
approximately once per hour).
Page # 2
Permit: NC0020656 Owner - Facility: Leith Creek WVVTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge
Judge, and other that are applicable?
Comment:
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n n
Is the facility as described in the permit? o n n n
# Are there any special conditions for the permit? nnn
Is access to the plant site restricted to the general public? o n n n
Is the inspector granted access to all areas for inspection? ` ❑ n
Comment:
Record Keeping
Are records kept and maintained as required by the permit?
Is all•required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Yes No NA NE
'nnn
unnn
Yes No NA NE
Name of person performing analyses
Transported COCs
Are DMRs.complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than.the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Yes No NA NE
unnn
Ennn
Eannn
Ennn
nn.ri
!a
n nn
nnno
n.non
® nnn
n nn
onnn
n nn
Page #
Permit: NC0020656 Owner - Facility: Leith Creek WWTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Record Keeping
Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? . n 0
Comment:
Effluent Pipe Yes. No NA NE
Is right of way to the outfall properly maintained? l n n n
Are the receiving water free of foam other than trace amounts and other debris? n n n
If effluent (diffuser pipes are required) are they operating' properly? ❑ ❑ g n
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting? . n n n
Is flow meter calibrated annually? n n n
Is the flow meter operational? a ❑ n n
(If units are separated) Does the chart recorder match the flow meter? n n n.
Comment:
Aerobic Digester - Yes No NA NE
Is the capacity adequate? n 1 ❑ n
Is the mixing adequate? l n n n
Is the site free of excessive foaming in the tank? ® n n n
# Is the odor acceptable? P ❑ n ❑
# Is tankage available for properly waste sludge? ❑ran n
Comment: Because of the sludge spill that occurred on the day of this inspection, it
appeared to this inspector that there was too much sludge inventory in the sludge
holding tanks and the clarifiers (10 feet_of sludge blankets in 13 feet of sidewall
clarifiers) .
Drying' Beds
Is there adequate drying bed space?
Is the sludge distribution on drying beds appropriate?
Are the drying beds free of vegetation?
# Is the site free of dry sludge remaining in beds?
Is the site free of stockpiled sludge? .
Is the filtrate from sludge drying beds returned to the front of the plant?
# Is the'sludge disposed of through county landfill?
Yes No NA NE
.nnn
E 0n n n
rnnn
nn
ntann
9t •n n n
El a n
Page # 4
Permit: NC0020656 Owner - Facility: Leith Creek WWTP
InspectionDate:• 02/18/2009 Inspection Type: Compliance Evaluation
Drying Beds
# Is the sludge land applied?
• (Vacuum filters) Is polymer mixing adequate?
Comment: Facility utilizes sludge drying beds as storage for up to two (2) years prior
to disposal.
Facility has a contract with a disposal firm.
Pump Station - Effluent
Is the purhp wet well free of bypass lines or structures?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment: On the day of this inspection, one of the four influent pumps was out of
service. The repair has been made but the pump was not yet reinstalled. An alarm is
activated when there is high water, if a pump goes out, seal failure, or if there is a power
failure. The alarm calls the water plant, if no-one answers, then the call goes to the
police station with an automated message to indicate the problem, and the police
station will phone the on -call person. All the lift stations have this ability of Scada
alarms.
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Yes No NA NE
E]nnn
nnon
Yes No NA NE
• nnn
nnn
• nnn
• nnn
• nnn
n nn
Yes No NA NE
® nnn
gnnn
nnn
n gnn
• nnn
• nnn
��nnn
Yes No NA NE
nnn
Page # 5
Permit: NC0020656 Owner - Facility: Leith Creek WWTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Bar Screens
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Comment: At one of two influent pump stations (the old Leith Creek facility) it
appeared that the pipe leading from the hydraulic press to the dumpster needed to be
shortened because the screenings were presently being. manually placed in the
du'mpster by means of five gallon buckets. The automatic bar screen was kept in the
automatic mode, as was the hydraulic press. An ultrasonic sensor controled when the
bar screen and hydraulic press operated.
Grit Removal
Type of grit removal
a.Manual
b.Mechanical
Is the grit free of excessive organic matter?
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Comment: One of two grit pumps was out of service at the time of this inspection, a
complete assembly was on order. A second one has also been requisitio"ned as a
back-up.
Equalization Basins
Is the basin'aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Yes No NA NE
Yes No NA NE
n
n n
E❑nn
n n n
Yes No NA • NE
nnn
® n n n
rinn
nnn
• nnn
n ❑ n E
nnnt
• nnn
Yes No NA NE
n n n
• n n n
Page # 6
Permit: NC0020656 Owner - Facility: Leith Creek WWTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Secondary Clarifier
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/< of the sidewall depth)
Comment: On the day of this inspection, the clarifiers sludge;blankets were 10 feet, in
a total clarifier sidewall depth of 13 feet.' The target clarifier depth was 2 to-5 feet of
sludge blanket depth. After the results of the Whole Effluent Toxicity from the week of
February 9, 2009 are received, plans are to take down Clarifier, #2 and Aeration Basin
#2 for repair of a bracket on the effluent side of Aeration Basin#2, and repair the rubber
part of the skimmer arm. A sludge judge measurement was routinely performed and
recorded once per day.
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/I)
Comment: After the results of the Whole Effluent Toxicity test (from the week of
February 9, 2009) are received, there are plans to take down Clarifier #2 (to repair the
rubber part of the skimmer arm) and the Aeration Basin #2 (to repair.a bracket on
effluent side of Aeration Basin #2). The fixed surface aerators were set on a timer.
Disinfection -Liquid
Is there adequate reserve supply of disinfectant?
(Sodium Hypochlorite) Is pump feed system operational?
Yes No NA NE
onnn
o nnn
Iunnn
onnn
o nnn
nnn
o nnn
npn
nnn
Yes No NA NE
Ext. Air
Fixed
nnn
nnn
o nEl
n nn
• nnan
El Ed
nnn133
4,1
Yes No NA NE
oElnn
onnn
Page # 7
Permit: NC0020656 Owner - Facility: Leith Creek WWTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Disinfection -Liquid
Is bulk storage tank containment area adequate? (free of leaks/open drains)
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Comment: The chlorine residual has not been checked prior to de -chlorination.
During this inspection, the ORC Back -Up said that he would begin frequent testing of
the chlorine residual prior to de -chlorination and document the results each time.. 15%
sodium hypochlorite solution (bleach) was utilized for disinfection. The chlorine contact
chamber sludge judge measurement was performed and recorded once per day.
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?.
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Yes No NA NE.
EDO'
nnn
n nn
n nn
Yes No NA NE
Gas'
n2
n nn
® Finn
Yes No. NA NE
nnn
• nnn
n nn
• DDD
EL
n nn
2nnn
ignnn
Page #
Permit: NC0020656 Owner - Facility: Leith Creek wWTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Standby Power
Comment: On the day. of this inspection, the generator for the influent pump station at
the old WWTP was tested under load. This WWTP facility participates in the load
management program in which, approximately once per month, the power will be turned
off and the generators with automatically come on. This POTW did not have a routine
schedule for running the generators. At the pump station site, the generators are run
once per month. The readings for the generators were read and recorded
approximately every other day to keep track of the time that the generators were run.
Scada will also show and record whether or not a generator comes on. On the day of
this inspection, each of the two large generators had at least three-quarters full capacity
of diesel in the tanks.
Pumps-RAS-WAS
Are pumps in place? n n n
Are pumps operational? n n n
Are there adequate spare parts and supplies on site?3# n n n
Comment: On the day of this inspection, one of the three sludge recirculation pumps
was out -of -service and was being repair at the Charles Underwood facility.
Laboratory
Are field parameters performed by certified personnel or laboratory? i n n n
Are all other parameters(excluding field parameters) performed by a certified lab? Eonnn
- # Is the facility using a .contract lab? n n n
# Is proper temperature set for sample storage (kept at less -than or equal to 6.0 degrees Celsius)? n n n
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?a n n n
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?a n n n
Comment:
Influent Sampling
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)?
Yes No NA NE
Yes No NA NE
Yes No NA NE
Is sampling performed according to the permit?
Comment:
Effluent Sampling
Is composite sampling flow proportional?
Yes No NA NE
nnun
nnn
nnn
r.nnn
nn
nnn
Yes No NA NE
nnn
Page # 9
Permit: NC0020656 Owner - Facility: Leith Creek VNNTP
Inspection Date: 02/18/2009 Inspection Type: Compliance Evaluation
Effluent Sampling
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)?
Is. the facility sampling performed as required by the permit (frequency, sampling type representative)?
Comment: Each 150 mL grab sample in the 24-hour composite was collected at a
frequency of one per 100,000 gallons of effluent flow.
Yes No NA NE
❑ ❑ ❑
n n n
n n n
n nn
n nn
Page # 10
egi.,nal Field inspectors Check Lust fs-r Field Parameters
Name of site to be Inspected: Laurinburq WWTP
Field certification # (if applicable):
NPDES #:NC0020656
Date: February 18, 2009
~` .^
Inspector:Dale Lopez L.._.._ t
Region: FRO
d. Circle the parameter or parameters performed at this site.
Residual Chlorine
Settleable Solids,
Di. Instrumentation:
pH
DO
Conductivity
Temperature
A. Does the facility have the equipment necessary to analyze field parameters as circled above?
A pH meter
YSI 60
A Residual Chlorine meter
3. DO meter
HACH DR 2400
YSI 550
4. A Cone for settleable solids
5. A thermometer or meter that measures temperature.
YSI 60
6. Conductivity meter
Ill. Calibration/Analysis:
Orion 3 Star
1. Is the pH meter calibrated with 2 buffers and
checked with a third buffer each day of use?
2. For Total Residual Chlorine, is a check standard
analyzed each day of use?
3. Is the air calibration of the DO meter performed
each day of use?
4. For Settleable Solids, is 1 liter of sample
settled for 1 hour?
5. Is the temperature measuring device calibrated
annually against a certified thermometer?
6. For Conductivity, is a calibration standard
analyzed each day of use?
Yes
Yes
Yes
No
No
No
Yes No
No
No
Yes
IYes
lye
fres
Yes
Yes
'Yes
IYes
No
No
No
No
No
No
ci mentation:
1. Is the date and time that the sample was collected documented?
2. Is the sample site documented?
3. Is the sample collector documented?
4. Is the analysis date and time documented?
5. Did the analyst sign the documentation?
6. Is record of calibration documented?
7. For Settleable Solids, is sample volume and
1 hour time settling time documented?
.8. For Temperature, is the annual calibration of
the measuring device documented?
Comment:
Yes
fres
fres
hies
Mes,
Yes
No
No
No
Yes . No'
fres
Please submit a copy of this completed form to the Laboratory Certification
DWQ Lab Certification
Chemistry Lab.
Courier # 52-01-01
-FIELD INSPECTOR CHECKLIST REV:04/23/2002
rogram.
3C ri 1'1,:A 7 IC o F Vl" tr 577-: WA 7 c i2 Flo
N =S-1, copos6- DI:cNl;ra 5E21791-
M A`( '2 s , 100\0
Tr-taut-4g 58
-.Or')6
DAY
ricp
ru:co1
L-
Ba•SSr.J
ITN
L
E.
t\ Tk rn
Srbr=c+J
L'{F1J
�I FLOW PJrnP
COLL ML rf-Trg 5Tt71d)
s3 FLO`] O
NOT TO
L.
1- M GD
Iria'6
naX
7_ -h')aI>
0
EtA71o1,1 .aSlld
0 • _ O
go . Z.
Ae eA71GW 34S!>1
O O O
No. i.
C;.AEIF72-r-Z
uo.3
CLAP1:1.SIZ 1.
IVY . Z
is ECI E C U LA, T1o11
PumP
yn usE_
SLUOG E.
I so, Goo
CALL
SL1-)vc7, DFYINE, 2= DS
a)-Fg7lr'11 • nQS1N 00.: 3 •
•
0
��Lor1K
3frTacr
5A!.rtJ
,T No-
C3DTN p(A,
Map of Laurinburg, NC by MapQuest
Page 2 of 2
211,]8_h1apOuesior TeleAilas
All rights reserved. Use subject to License/Copyright Map Legend
Directions and maps are informational only. We make no warranties on the accuracy of their content, road conditions or
route usability or expeditiousness. You assume all risk of use. MapQuest and its suppliers shall not be liable to you for
any loss or delay resulting from your use of MapQuest. Your use of MapQuest means you agree to our Terms of Use
7_u.__//_' a___T O__a_a_-1.T/"�
/1 APIAAA
WATER POLLUTION CONTROL, SYSTEM OPERATORS
CERTIFICATION COmmISSION
CLASSIFICATION
RATING SKEET FOR WATER POLLUTION CONTROL SYSTEMS
FACILITY INFORMATION:
NAME OF FACILITY:
5 MAILING ADDRESS: C r' L .rf�- r / :'� Z�,�Q/C
'8 L Ci 9J
� J
COUNTY: CL 72_,9iI D
CONTACT PERSON: -486-4 % "L 1 S ' tLEPHONE: ( 9/4 _ z-1 /
49
PERMIT NO: ,s `a (_. & 1) 656 Check One: NC
WQ
HEALTH DP
ORC: � � 0 �r TELEPHONE: (9/) 7 7 / V
RATING INFORMATION: (Before completing this section, please refer to pages 2-4)
PERMITTED FLOW:: MGD BNR? YES NO
CHECK CLASS1r1CATION: WAS i'EWA 1'ER: 1 2 3 4
COLLEC,1.10N: 1 2 3 4
SPRAY IRRIGATION SUBSURFACE LAND APPLICATION
PHYSICAL/CHEMICAL GRADE I GRADE II
RA ILD BY: � � cip REGION: �1 'L'' DATE:
REGIONAL OFFICE 1'LLF_PHONE NUMBER: (9/6) "33 — 3234} EXT:
Classification of Biological Water Pollution Control Treatment Systems:
Grade I Biological WPCS
- Septic tank sand filter systems.
- Biological lagoon systems
- Constructed wetlands and associated appurtenances
Grade II Biological WPCS
- Systems that utilize an activated sludge or fixed growth process with a permitted flow
less than or equal to 0.5 million gallons per day (mgd)
Grade III Biological WPCS
- Systems that utilize an activated Sludge or fixed growth process with a peintitted flow
of greater than 0.5 through 2.5 million gallons per day (mgd)
- Grade 11 systems that are required to achieve biological nutrient reduction *
Grade IV Biological WPCS
- Systems that utilizing an activated sludge or fixed growth process with a permitted flow
Of greater than 2.5 million gallons pet day (mgd)
- Grade III systems that are required to achieve biological nutrient reduction *
* Biological Nutrient Reduction
The reduction of total nitrogen or total phosphorous by an activated sludge or fixed growth
. process as required by the facilities permit.
Classification of Collection Water Pollution Control Systems:
(whichever provides lowest grade)
Same grade as biological water pollution control system. Grade of system:
Based on population served:
1,500. or Less = Grade I
1,501 to 15,000 Grade II
15,001 to 50,000 = Grade III
50,001 or more = Grade IV
mole. l ttluent Toxicity Testing Self -Monitoring Summary February 18, 2009
FACILITY REQUIREMENT YEAR JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Fayetteville -Rockfish WWTP chr lim: 3.5% ; 24 MGD @ 4.6%; 24 MGD r@ 5 Ceri7dPF ¥ 2005 Pas, - - Pass ,Fail - - Pas, - pass>td(P) pass>14(P) -
NC0050105/001 Begin.3/I/2007 Frequency: Q Jan Apr Jul Oct + NonComp:Single 2006 Pass>14(P) - - Pass>14(P) - - Pass - - Pass --
County: Cumberland Region: FRO Subbasin: CPF15 2007 Pass - - Pass - - Pass Pass - Pass >12 >1- 8.4
PF: 16.0 Special 2008 posy - - Fail >18.4 >18.4 Pass Pass
7010: 675.0 1WC(%) 3.5 .Order: 2009 - -- - -
Fort Bragg WWTP/001 • chr lim: 26% Ceri7dPF 2005 Pass - - Pass - - Pass - - Pass
NC0003964/001 Begin.9/1/2006 Frequency: Q Jan Apr Jul Oct + NonComp:Single 2006 Fail 37.9 78 Pass - - Pass - -- Pass
County: Cumberland Region: FRO Subbasin: CPF14 2007 Pass - - Pass - - Invalid,Pass - -- Pass
PF: 8.0 Special 2008 Pass - - Pass - Pass - . Pass
7Q10: 35.8 IWC(%) 26 Order: 2009
Hamlet WWTP chr lim: 38% Ceri7dPF
NC0047562/001 Begim3/I/2004 Frequency: Q Jan Apr Jul Oct + NonComp:Single
County Richmond Region: FRO Subbasin: YAD16
PF: 1.0 special
7Q10: 2.5 IWC(%) 38.27 ceder:
2005 Pass - - Pass - - Pass - - Pass - -
2006 Pass - - Pass - Pass - - Pass - -
2007 Pass - - Pass - - Pass - - Pass - -
20DQ Pa,, - - Pass - - Pass - - Pass -
2009 Pass
Industrial & Agricultural Chemicals 48HR LCSO AC MOMT CERIO OR DAPH (GPCeri48Ac
NC0000236/001 Begin:2/1/1994 Frequency: 2/YR Semiannual NonComp•
County: Robeson Region: FRO Subbasin: LUMS2
PF: VAR Special
7Q10: 0 TWC(%)NA Order:
2005
2006
2007
2008
2009
Laurinburg- Leith Creek WWTP chrlim: 31% Ceri7dPF 2005 - Pass - - pass - - Pass - Pass
NC0020656/001 Begin: 11/1/2004 Frequency: Q Feb May Aug Nov + NonComp:Single 2006 - Pass - - Pass - - Pass - - Fail 10- .96
County: Scotland Region: FRO Subbasin: LUM55 2007 >100 Pass - - Pass - - Pass - - Pas, -
PF: 4.0 Special 2008 - pass -
7Q10:13.8 IWC(%) 31 Order: 2009 Pass,>100(P) - - Pass>100(P) - - Pass -
Laurinburg Merton Airport -Laurel Hill chr lim: 1.5% Ceri7dPF ¥ 2005 - - Pass -- Pass - - Pass - - Pass
NC0005479/001 Begin:11/1/2004 Frequency: Q Mar Jun Sep Dec + NonComp:Single 2006 - - • Pass - - Pass - - Pass - - Pass
County: Scotland Region: FRO Subbasin: LUM55 2007 - - Pass - - Pass - - Pass ._ Pass
PF: 0.3 Special 2008 - - Pass - Pass - - Pass - - Pass
7Q10: 31.0 IWC(%) 1.5 Order: 2009
Laurinburg-Marton Airport (LMAC) WWTP chrlim: 2.6% Ceri7dPF ¥ 2005 - - - Pass - Invalid Late Pass Pass - Pass
NC0044725/001 Begin.6/1/2005 Frequency: Q Mar Jun Sep Dec + NonComp: Single 2006 Pass - -- Pass - - Pass - Pass
County: Scotland Region: FRO Subbasin: LUM51 2007 - - Fail 0.92 0.92 . Pass - - Pass -- -- Fail
PF. 2.0 Special 2008 <0.65 <0.65 Fail <0.65 <0.65 Fail 1.8 >10.4 Fail <0.65 <0.65 Fail
7Q10: 111.0 IWC(%) 2.72 . Order: 2009 I ..
Lumberton Power, LLC chr lim: 0.51% Cen7dPF 2005 - Pass - - Pass - - H - - H -
NC0058301/003 Begin:7/1/2005 Frequency: Q • Feb May Aug Nov + NonComp:Single 2006 - H - - H - - Pass - - H Pass
County: Robeson Region: FRO Subbasin: LUM51 2007 - Pass - - Pass - - Pass - -- Pass
PF: 0.45 Special 2008 - Paas - - Pass - - Pass - Pass
7Q10: 120.0 IWC(%) 0.51 Order: 2009 - -
Lumberton WWTP chr lim: 21% Ceri7dPF It 2005 - Pass - - Invalid Pass • - Pass - - Pass -
NC0024571/001 Begin 9/1/2004 Frequency: Q Feb May Aug Nov + NonComp:Single 2006 - Pass - - Pass - - Pass - - Pass
County: Robeson Region: FRO Subbasin: LUMS1 2007 - Pass - - Pass - - Pass -- -- Pass -
PF: 20 Special 2008 - Pass>84(P) - - Pass>84(P) - - Pass>84(P) - - Pass>84(P)
7Q10: 120 TWC(%) 21 Order: 2009 -
Moore County WWTP chrlim: 41% Ceri7dPF ¥ 2005 - - Pass - - Pass - - Pass - - Pass
- NC0037508/001 Begin.7/1/2005 Frequency: Q Mar Sim Sep Dec + NonComp:Single 2006 - - • Pass - - Fail 14.5 >100 Pass - - Fail
County: Moore Region: FRO Subbasin: LUM50 2007 Invalid 58.0 Pess(s) >100(s) - Pass - - Pass -- -- Pass
PF: 6.7 Special 2008 - -
7Q10: 15.2 IWC(%) 40.54 Order: 2009 Pass,>82(P) - - Pass>100(P) - - Pess>100(P) - - Pass >100(P)
Mt. Gilead WWTP chr lim: 3.2% Ceri7dPF 2005 - - Pass - -- Pass - - Pass - - Pass
NC0021105/001 Begin'3/1/2005 Frequency: Q Mar Jun Sep Dec + NonComp:Single 2006 - - Pass - - Pass ,Pass - - Pass - - Pass
County: Montgomery Region: FRO Subbasin: YAD10 2007 - - Pass - __ Pass - - Pass - Pass
PF: 0.85 Special 2008 - - Pass -- Pass - - Pass Pass
7Q10: 40 IWC(%) 3.2 Order: 2009 -
¥ Pre 2005 Data Available
•
LEGEND:
PERM = Permit Requirement LET = Administrative Letter - Target Frequency = Monitoring frequency: Q- Quarterly; M- Monthly; BM- Bimonthly: SA- Semiannually; A- Annually; OWD- Onlylwhen discharging; D- Discontinued monitoring requirement
Begin = First month required 7Q10 = Receiving stream low Bow criterion (cfs) + = quarterly monitoring increases to monthly upon failure or NR Months that testing must occur - ex. Jan, Apr, Jul, Oct NonComp = Current Compliance Requirement
PF= Permitted flow (MGD)' IWC%= lnstream waste concentration P/F= Pass/Fail test AC=Acute CHR=Chronic
Data Notation: f - Fathead Minnow; • - Ceriodaphnia sp.: my - Mysid shrimp: ChV - Chronic value; P - Mortality of stated percentage at highest concentration; at - Performed by DWQ Aquatic Tox Unit; bt - Bad test
Reporting Notation: --- = Data not required; NR- Not repotted Facility Activity Status: 1- Inactive, N - Newly Issued(To construct); H - Active but not discharging; t-More data available for month in question; = ORC signature needed
3
Whole Effluent Toxicity Testing Self -Monitoring Summary
November 14, 2006
FACILITY REQUIREMENT YEAR JAN FEB t`4i‘11AN ' MAY JUN JUL "UG SEP OCT NOV DEC
F'aycllcville-Rockfish WWTP chr lint: 3.5%
NC0050105/001 Begin: 11/12002 Frequency: Q .m Apr Jul Oct
County:. Cumberland Region: FRO Subbasin: CPF15
PF: 16.0 Special
7010: 675.0 1WC(%) 3.5 oaten
Ceri7tlPP 5 2002 Pass
+ NonConlp:Single 2003 Pass
2004 Pass --
2005 Pass
2006 Pass >14(P) --
Pass
Pass
Pass
Pass
Pass,>14(P) ---
Fall >14 >14 Late
Pass --- --- Pass
Pass --- --- Pass
Pass --- Pass>14(P) Pass,>14(P)
Pass -- - Pass
Pass
Fort Bragg WWTP/001 • chr Om: 26 %
NC0003964/00I Begin:9/1/2006 Frequency: Q Jan Apr Jul Oct
County: Cumberland Region: FRO Subbasin: CPI' 14
PF: 8.0 - Special
7Q 10: 35.8 lWC(%)26 Ordu:
Ceri7dPF 2002 Pass
+ NonComp:Single 2003 Pass
2004 Pass
2005 Pass
2006 Fail
--- --- Pass --- Pass ' -•- Pass
Pass --- Pass --- --- Pass
-- --- Pass --- •-- Pass Pass
... --- Pass --- Pass -- Pass
37.9 78 - Pass --- --- Pass
Hamlet WIVTP chr lint: 38% Ceri7dPF 2002 Pass --- --- Pass
NC0047562/001 Begin:3/1/2004 Frequency: Q Jan Apr Jul Oct + NonComp:Single 2003 Pass -- --- Pass ---
County: Richmond Region: FRO Subbasin: YAD16 2004 Fail >76 >76(p),>76 Pass>76(p) >76(p)
PF: 1.0 - Special 2005 pass • --- --- Pass ---
7Q10:2.5 IWC(%) 38.27 Order: 2006 Pass Pass
Pass -- Pass
Pass --- - Pass
>76(p) Pass --- - Pass
--- Pass --- --- Pass
Pass
Industrial & Agricultural Chemicals 4811R LC50 AC MONIT CERJO OR DAPH (GRCeri48Ac
NC0000236/001 Begin:2/1/I994 Frequency: 2/YR Semiannual NonComp:
County: Robeson Region: FRO . Subbasin: LUM52
PF: VAR Special
7Q10: 0 IWC(%)NA Order:
2002
2003
2004
2005
2006
Laurinburg Mallon Airport -Laurel Hill chr lint: 1.5%
NC0005479/00 I Begin: 11/1/2004 Frequency: Q Mar Jun Sep Dec
County: Scotland Region: FRO Subbasin: LUM55
PP: 0.3 Special
7010: 31.0 ANC(%) 1.5 Order
Ceri7dPF 5 2002 ---
+ NonComp:Single 2003 ---
2004 ---
2005 _.
_ 2006 ---
Pass --- --- Pass --- Pass --- --- Pass
Pass --- Pass Pass •-- --- Pass
Pass --- Pass Pass . --- --- Pass
Pass --- Pass --- Pass --- Pass
Pass -- •Pass -- " - Pass
La IIrinbgrg VVWTP chr lim:31% . Ceri7dPF 2002 --- Pass
NC0020656/001 Begin:11/1/2004 Frequency: Q ' Feb May Aug Nov + NonComp:S logic 2003 --- Pass ---
County: Scotland Region: FRO Subbasin: LUM55 2004 - Pass,>62(p) >62(p)
PF: 4.0 - Special 2005 ... Pass ---
7010: 13.8 IWC(%) 31 Order 2006 --- Pass
Pass --- Pass - Pass
Pass -- --- Pass --- --- Pass
Pass>62(P)t --- Pass --- Pass
Pass --. --- Pass -- Pass
Pass Pass
Laurinburg-Mnxtnn Airport (LMAC) WWTP chr lint: 2.6% Ceri7dPF 5 2002 --- --- Pass --- Pass
N00044725/001 Begin`.6/I/2005 Frequency: Q Mar Jun Sep Dec + NonComp:Single 2003 --- --- Pass --- --- Pass
Courtly:"Scotland Region: FRO Subbasin: LUM51 2004 1.84(p) -- Pass>5.2(p) --- Pass
PF: 2.0 Special 2005 _- Pass --- --- Invalid
7Q10: 111.0 IWC(%)2.72 Order: 2006 --- Pass --- Pass
Late
Pass --- Pass
--• Pass --- Pass,>5.1(p)
-• Pass --- --- Pass
Pass . Pass --- Pass
Pass
Lumberton Power, LLC chr lint: 0.51% Ceri7dPF 2002 --- Pass
NC0058701/003 Begin:7/1/2005 Frequency: 0 Feb May Aug Nov + NonComp:Single 2003 --- Pass
County: Robeson Region: FRO Suhhasin: LUMSI 2004 --- Pass
PF: 0.45 Speci:d 2005 -' Pass
7010: 120.0 . IWC(%) 0.51 . ' Order. 2006 -- H
Pass
Pass
Pass
Pass
H
Pass
Pass
Pass
H
Pass
Pass
Pass
Pass
H
Lumberton WWTP chr lint: 21 %
NC0024571/001 Begin:9/1/2004 Frequency: Q Feb May Aug Nov
County: Robeson Region: FRO Subbasin: LUM51 .
PF: 20 Special
7010: 120 IWC(%) 21 Order
Ceri7dPF 5 2002 Pass
+ NonComp:Single 2003 --- Pass
2004 --- Pass'>42(p)
' 2005 .-. Pass
2006 -- Pass
Pass
Pass
Pa55
Invalid
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Moore County WWTP chr lit,: 41% Ceri7dPF 0 2002 -- --- Pass --- Pass
NC00J7508/00I Begin:7/1/2005 - Frequency: Q Mar Jun Sep Dec + NonComp:Single 2003 -- --- Pass --- Pass ---
County: Moore Region: FRO Subbasin: L11M50 2004 50(p) pass.>62(p) Pass>82(P) - .
PF: 6.7 Special , 2005 - ._ Pass --- Pass ---
7Q.10: 15.2 IWC(%) 40.54 Order. 2006- -- -- Pass - Fail 14.5
>100
Pa55
Pass --
Pass>71(P) ---
Pass
Pass
Pass
Pass
Pass
Pass
Alt. Gilead \\M'TP chr lim: 7.2% Ceri7dPF 2002 -- --- Pass --- --- Pass
NCOO21105/001 Begin:3/1/2005 Frequency: Q Mar.lun Sep Dec + NonComp:Single 2003 •-- --- Pass --- -- Pass
County: Montgomery Region: FRO Suhhasin: \'ADIO 2004 --- --- Pass --- --- Pass
PF: 0.85 Special 2005 _. -- Pass --- Pass,
7010: 40 1WC(%) 3.2 Order 2006 -- --- Pass --- Pass,Pass
Late
Pass
Pass
Pass .
Pass
Pass
Pass
Pass
Pass
Pass
4 Pre 2002 Data Available
LEGEND:
PERM = Permit Requirement LET= Administrative Lester- Target Frequency = Monitoring frequency: Q- Quarterly; M- Monthly; BM- Bimonthly; SA- Semiannually; A- Annually; OWD- Onhv when discharging D. Discontinued monitoring requirement
Begin = First month required 7Q10 = Receiving stream law limy criterion (crs) += quarterly monitoring increases to monthly upon failure or NR Monl Its that testing must occur - ex. Jan, Apr, Jul, Oct NonComp = Current Compliance Requirement
PF = Permitted Bow (MGD) IWC%= Inslream waste concentration P/F = Pass/Fail test AC = Acute . CHR = Chronic
Data Notation: f - Fathead Minnow; • - Ceriodaphnia sp.; my - Mysid shrimp; ChV - Chronic value; P - Mortality of slated percentage at highest concentration; al - Performed by DWQ Aquatic Tox Unit; In - Bad test
• Reporting Notation: --- = Data not required; NR • Not reported Facility Activity Status: I - Inactive, N - Newly Issued(To construct); H - Active but not discharging: t-More data available for month in question; = ORC signature needed
.• 3
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
OUTFALL: 001
EFFLUENT
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2006
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 5 OF 7
00010
deg c
Temperature,
Water Deg.
Centigrade
00094
umhos/cm
Conductivity
00300
mg/1
DO, Oxygen,
Dissolved
00310
mg/1
BOO, 5-Day (20
Deg. C)
00400
su
pH
00530
mg/1
Solids, Total
Suspended
00600
mg/1
Nitrogen, Total
(as N)
00610
mg/1
Nitrogen,
Ammonia Total
(as N)
20
30
5
1 -06
15.25
252.2
8.535
7.047619
6.3 - 7.2
24.333333
9.48
2.177143
20
30
5
2-06
13.8
230.75
8.76
4.01
6.1 - 7.6
16.5
12.6
1.4155
20
30
5
3-06
14.434783
285.521739
8.465217
1.277273
6.5 7.5
10.454545
6.52
0.079545
20
30
5
4-06
17.526316
321.473684
8.015789
1.805
6.3 - 7.1
6.7
1.37
0.018
20
30
5
5-06
•
19.227273
363.681818
7.822727
3.286364
6.3 6.8
8.363636
8.13
0.457273
20
30
5
6-06
22.681818
363.590909
6.75
4.661905
6.2 6.8
16.238095
18.5
1.300952
20
30
5
7-06
24.7
352.55
6.375
2.090476
5 V - 6.4
12.238095
15.3
0.375238
20
30
5
8-06
25.73913
417.26087
5.795652
1.652174
6 - 7.2
12.956522
9.86
0.626522
20
30
5
9-06
24.05
399.85
6.055
1.64
6 - 6.9
11.631579
20.4
0.119474
20
30
5
10-06
20.318182
415.863636
7.286364
4.126087
6.7 - 7.1
17.434783
12.6
0.260435
11 - 06
20
30
5
17.5
372.35
7.08
6.21
6.5 - 7
18.65
23.6
1.797
20
30
5
12-06
14.736842
306.736842
7.926316
5.95
6 - 6.8
15.944444
1.206111
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2006
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 6 OF 7
00665
mg/1
Phosphorus,
Total (as P)
00951
mg/1
Fluoride, Total
(as F)
01092
mg/1
Copper, Total
(as Cu)
01092
mg/1
Zinc, Total (as
Zn)
31616
#/100m1
Coliform, Fecal
MF, M-FC
Broth,99.5C
50050
mgd
Flow, in
conduit or thru
treatment plant
50060
mg/1
Chlorine, Total
Residual
50060
ug/1
Chlorine, Total
Residual
1-06
4
1.09
0.01
0.034
4.198268
3.457226
0.627
2-06
4
1.22
0.47
0.011
0.021 .
2.932671
3.216464
0.562
3-06
4
1.72
0.017
0.052
3.704788
2.454323
0.456957
4-06
2.52
0.006
0.06
3.608502
1.807267
0.277895
5-06
4
1.28-
0.87
0.012
0.053
6.385328
1.698129
8.181818
4
6-06
2.7
0.019
0.078
27.9774
2.1262
12.590909
.
7-06
4
2.38
0.018
0.045
16.013261
1.944065
15.7
8-06
2.7
0.82
0.02
0.03
82.838978.
1.724645
14.086957 ,
9-06
4
3.15
0.022
0.115
81.51379
1.884433
13.15
a
10-06
3.04
0.015
0.079
53.332279
1.69171
18.090909
11-06
4
4.07
1.03
0.027
0.076 ,
101.113409
2.551833
14.95
12-06
4
69.040315
2.981645
16.105263
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
71900
ug/1
Mercury, Total
(as Hg)
NC01
ug/1
Annual
Pollutant Scan
(126 parameters)
TGP3B
pass/fail
P/F STATRE 7Day
Chr Ceriodaphnia
'
THP3B
percent
CHV STATRE 7Day
CHR Ceriodaphnia
1-06
2-06
1
3-06
• 4-06
5-06
1
6-06
. 7-06
8-06
1
9-06
-
10-06
11 - 06
2
12-06
PERIOD ENDING MONTH: 12 - 2006 DMR 12 Month Calculated
PAGE 7 OF 7
REGION: Fayetteville
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
OUTFALL: 001
EFFLUENT
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2007
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 5 OF 7
00010
deg c
Temperature,
Water Deg.
,Centigrade
00099
umhos/cm
Conductivity
-
00300
mg/1
D0, Oxygen,
Dissolved
00310
mg/1
BOD, 5-Day (20
Deg. C)
00900
su
pH
00530
mg/1
Solids, Total
Suspended
00600
mg/1
Nitrogen, Total
(as N)
00610
mg/1
Nitrogen,
Ammonia Total
(as N)
•
1 - 07
14.428571
•253.761905
8.657143
20
3.786364
6.5 - 7
30
17.363636
7.96
5
0.157273
2-07
12.8
271.35
8.845
20
4.08
6.1 - 6.7
30
.13.9
-
8.01
5
0.224
3-07
15.272727
259.409091
8.059091
20 •
4.02381
6.5 - 7
30
8.857143
9.09
5
0.031905
4 - 07
17.1
323.8
8.065
20 -
5.628571
6.7. - 7.2
30 .
8.952381
' 2:32
5
1.989048
5-07
19.909091
334.045455
8.372727
20
2.490909
6.7 - 7.3
30
4.863636
2.53
5
0
6-07
23.238095
409.095238
7.609524
20
1.24
6.5 - 6.9 .
30
4.2
13.6
5
0.054
7 07
24.52381
493.952381
7.471429
20
0.381818
6 - 6.9
30
7.272727
22.2
5.
0
8-07
26.086957
476.565217
7.813043
20
0.677273
6.2 - 6.7
3: .
6.045455
'22.3
5
0.022273
9-07
_
23.631579
470.157895
8.105263
20
0.685
6.4 - 6.8
30
5.1
22.14
5
0.2025
10-07
21.73913
478.652174
8.178261
20
0.552174
6.5 - 7.3
30
6.26087
•
21.5
5
0.327391
11 - 07
16.6
480.05
8.575
20
1.363158
6 - 7.2
30
8.526316
23.4
5
0.28
12 07
14.5
470.055556
9.422222
20 ,
0.523529
6 - 7.1
30
6..777778
26
5
0.026667
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2007
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 6 OF 7
00665
mg/1
Phosphorus,
Total (as P)
00951
mg/1
Fluoride, Total
(as F)
01042
mg/1
Copper, Total
(as Cu)
01092
mg/1
Zinc, Total (as
Zn)
31616
9/100m1
Coliform, Fecal
MF, M-FC
Broth,44.5C
50050
mgd
Flow, in
conduit or thru
treatment plant
50060
ug/1
Chlorine, Total
Residual
71900
ug/1
Mercury, Total
(as Hg)
1 -07
4
1.54
0.012
0.038
109.442541
3.223871
12.571429
2-07
4
1.21
0.01
0.038
82.221581
3.248714
11.7
3-07
4
1.62
0.01
0.042
69.818425
3.29829
13.636364
4-07
1.26
0.007
0.046
70.846855
2.7077
16.6
5-07
4-
1.51
0.74
0.006
0.05
74.915806
1.913581
17.136364
•
6-07
4
4.23
0.01
0.063
68.012653
1.6895
19.619048
7-07
4.13
0.015
0.127
64.017482
1.502968
18.285714
8-07
4
3.68
1.07
0.017
0.075
80.225986
1.501677
17.869565
9-07
4
4.78
0.011
0.082
81.062058
1.476233
16.315789
10-07
4
.3.07
111.264675
1.603968
21.956522
11 -07
4
2.95
0
82.784359
1.4427
12.85
12-07
4
2.64
102.916882
1.658742
0.944444
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
.
NC01
ug/1
Annual
Pollutant Scan
[126 parameters]
TGP3B
pass/fail
P/F STATRE 7Day
Chr Ceriodaphnia.
THP3B
percent
CHV STATRE 7Day
CHR Ceriodaphnia
1 -07
2-07
1
3-07
4-07
5-07
1
, 6-07
7-07
8-07
1
9-07
10-07
11 -07
1
12-07
PERIOD ENDING MONTH: 12 - 2.007 - DMR 12 Month Calculated
PAGE 7 OF 7
REGION: Fayetteville
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
OUTFALL: 001
EFFLUENT
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2008
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 5 OF 7
00010
deg c
Temperature,
Water Deg.
Centigrade
00099
umhos/cm
Conductivity
00300
mg/1
DO, Oxygen,
Dissolved
00310
mg/1
BOD, 5-Day (20
Deg. C)
•
00900
su
pH
00530
mg/1
Solids, Total
Suspended
00600
mg/1
Nitrogen, Total
(as N)
00610
mg/1
Nitrogen,
Ammonia Total
(as N)
1 08
20
30
5
12.571429
395.714286
9.604762
1.022727
6.1 - 6.9
8.363636
21
0.803636
2-08
20
30
5
13.666667
413.904762
9.647619
2.645
6.3 - 7
11.4
18.4
0.54
3-08
N
20
30
5
14.55
296.15
9.14
2.619048
6.7 - 7.2
9.714286
7.05
0.393333
4-08
20
30
5
17.318182
265.954545
8.118182
5.759091
6.3 - 7
9.590909
3.77
1.137727
20
30
. .
5
5-08
19.952381
309.619048
8.42381
2.515
6.5 - 7
7.15
8.6
0
6-08
20
30
5
23.761905
391.952381
8.080952
0.672727
6.2 - 7.2
6.272727
14.3
0.363182
7 08
20 -
30
5
25.045455
416.090909
7.618182
2.009524
6 - 6.9
12.136364
27.4
1.160909
8 08
20
30
5
25.190476
342.52381
7.085714
0.62
6 - 6.9
5.25
13.4
0.0985
9 OS
20
30
5
23.952381
230.52381
8.395238
0.536364
6 - 6.6
13.045455
10.6
0.296818
10-08
20
30
5
20.391304
337.478261
8.469565
0.604545
6 - 6.9
11.090909
6.1
0.118636
11 08
20
30
5
16.611111
399.666667
9.266667
2.194444
6 - 7
13.421053
23.4
0.053158
12 08
20
30
5
15.4
332.85
9.47 .
0.842105
6 - 7
9.105263
11.3
0.005263
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
PERIOD ENDING MONTH: 12 - 2008
REGION: Fayetteville
DMR 12 Month Calculated
PAGE 6 OF 7
00665
mg/1
Phosphorus,
Total (as P)
00951
mg/1
Fluoride, Total
(as F)
01092
mg/1
Copper, Total
(as Cu)
01092
mg/1
Zinc, Total (as
Zn)
31616
4/100m1
Coliform, Fecal
MF, M-FC
Broth,44.5C
50050
mgd
Flow, in
conduit or thru
treatment plant
50060
ug/1
Chlorine, Total
Residual
71900
ug/1
Mercury, Total
(as Ag)
1-08
4
2.35
0.009
0.063
123.495103
1.87271
2.857143
2 - 08
4
1.86
0.77
0.018
0.064
154.948687
2.168138
4.190476
3-08
a
2.86
0.013
0.051
37.372657
2.597226
21.9
4-08
4
1.28
0.008
0.025
78.109095
3.178933
19.863636
5-08
4
1.68 '
0.92
0.008
0.075
75.975071
2.001258
18.428571
6-08
3.76
.
0.013
0.092 .
142.023423
1.733133
21.285714
7-08
4
4.25
0.038
0.165
170.991926
2.088645
24.190476
8-08
4
1.69
0.9
0.012
0.055
129.040255
2.711129
10.761905
9-08
4
1.01
0.01
0.043
103.560567
4.0369 Violation
14 •
10-08
4
1.76
0.009
0.024
77.028778
2.220419
16.173913
11-08
4
2.77
0
0.013
0.053
102.848418
2.220733
11.111111
5.38
12-08
4
1.96
0
0.034
66.965486
2.968935 •
11.55
PERMIT NUMBER: NC0020656
FACILITY NAME: City of Laurinburg - Leith Creek WWTP
CITY: Laurinburg
COUNTY: Scotland
NC01
ug/l.
Annual
Pollutant Scan
[126 parameters]
TGP3B
pass/fail
P/F STATRE 7Day
.Chr Ceriodaphnia
THP3B
percent
CHV STATRE 7Day
CHR Ceriodaphnia
1 -08
2-08
1
3-08
4-- 08
5-08
1
6-08
7-08
8-08
1
9-08
10-08
11-08
12-08
-
PERIOD ENDING MONTH: J2 - 2008 DMR 12 Month Calculated
PAGE 7 OF 7
REGION: Fayetteville