Shield Engineering, Inc. (Shield) successfully collected a monthly stormwater sample for Stormwater Discharge
Outfall (SDO) #004 at the CIRCOR Pumps North America LLC — Monroe facility on May 27, 2020. The pH at
SDO #004 was measured at 7.9. Total event precipitation was 0.96 inches. In addition to collection of samples,
Shield performed Qualitative Monitoring at SDO #004 (attached).
Shield has prepared the Stormwater Discharge Monitoring Report (DMR) using the results of analyses from the
commercial laboratory that the CIRCOR facility has contracted with and the field values indicated above. The
attached DMR should be signed by CIRCOR's authorized representative and then two signed copies of the DMR
form should be mailed to the regulatory agency's Central Files.
The sampling results from the May 271' event show that CIRCOR exceeded the benchmark concentration for
Copper. CIRCOR remains in Tier Three for Copper and Zinc at SDO #004. Shield will continue to perform
monthly sampling for SDO #004 per Tier Two requirements until instructed to halt by CIRCOR. Shield greatly
appreciates the opportunity to provide environmental services to CIRCOR. If you have any questions in
reference to this document or require further information, please feel free to contact either of the undersigned at
(704)394-6913.
Respectfully,
SHIELD ENGINEERING, INC.
Magdaline Tzannis
Senior Project Manager
ndaS
ATTACHMENTS
Robert L. Griffin, PE
President/CEO
4301 Taggart Creak Road Telephone 704.394.6913
Chadotte, NC 26208 _ w .shleldengineeringxom Fax 704.394.6968
Stormwater Discharge Monitoring Report
for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000
Date submitted 6/10/2020
CERTIFICATE OF COVERAGE NO. NCG03 0 2 9 3
FACILITY NAME Circor Pumping Technologies
COUNTY Union
PERSON COLLECTING SAMPLES Magdaline Tzannis /Shield Engineering, Inc.
LABORATORY Pace Analytical Services, LLC Lab Cert. # 329
Comments on sample collection or analysis:
There is an exceedance of copper at SOO 004
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2020
SAMPLE PERIOD Jan -June Q July -Dec
or Q Monthlyt May (month)
DISCHAI DING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
c�+�,v v ❑Zero -flow ❑Water Supply ❑SA
REG Mother
DWS CT C� PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3
n No discharge this aeriod?2
Outfall No.
Date Sam le
p
Collected/
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Total Suspended Solids
Standard units
Total Copper
Tatal Lead
Total Zinc
Non -Polar 0&G/
Total Petroleum
Hydrocarbons
Total Toxic
Organics
Benchmarks
_
-
100 mg/L or 50 mg/O
6.0 — 9.0
0.010 mg/L
0.075 mg/L
0.126 mg/L
15 mg/L
1 mg/L
Parameter Cade
-
46529
C0530
00400
01119
01051
01094
00552
78142
SDO #004
5/27/2020
0.96
13
7.9
0.012
<0.010
0.054
<5.0
<0.2116
' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance forthe same parameter at the same outfall.
2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies.
5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor
manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 1 of 3
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring
may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or
Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the
solvent management plan included in the Stormwater Pollution Prevention Plan."
Name (Print name)
Title (Print title)
Signature
Date
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PCQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: 1f you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
❑ No discharge this period?Z
Outfall No.
Date Sample Collected'
(mo/dd/yr)
24-hour rainfall amount,
Inches;
New Motor Oil or
Hydraulic Oil Usage
Non -Polar O&G/ Total
Petroleum Hydrocarbons
Total Suspended
Solids
Benchmarks
-
-
-
15 mg/L
100 mg/L or 50 mg/O
Parameter Code
-
46529
NCOIL
00552
C0530
Footnotes from Part A also apply to Part B
Note: 1f you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date:11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 2 of 3
FOR PARTA AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES 0 NO 0
IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an original copy of this DMR, including all "No Discharge" resorts, within 30 days of receipt of the lab results for at end of monitoring period in the
case of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly r ponsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am awarlet+iahthere ato significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
�J
Date
Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 3 of 3