Loading...
HomeMy WebLinkAboutNCG030212_DMR_20201120Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. Date submitted 11/20/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 1 2 FACILITY NAME Prysmian Cables and Systems USA, LLC COUNTY Catawba PERSON COLLECTING SAMPLES Rick Miller LABORATORY Waypoint (Prism) Labs Lab Cert. # 402 Comments on sample collection or analysis: June 162WO samples -TOM appikable(m EWWOO", Metal AmsNng or FJeanceVElecheNc c Pannta4 eaealte) Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or 0 Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ECr771\/Fr) ❑Zero -flow ❑Water Supply [:]SA NOV 3 p 2020 Mother Tier II E:N_l I hL i ILE PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 UWR SLCTIOid n No discharge this period?' Outfall No. Benchmarks Date Sample collected' (mo/dd/yr) - 24-hour rainfall amount, Inches' - Total Suspended Solids 100 mg/L or 50 mg/L4 pH, Standard units 6.0 — 9.0 Total Copper 0.010 ml Total Lead 0.075 ml Total Zinc 0.126 mg/L Non -Polar O&G/ Total Petroleum Hydrocarbons 15 ml Total Toxic Organics' 1 mil Parameter Code - 46529 COS30 00400 01119 o1051 01094 00552 78141 SDO-002 10/28/20 1.8 4.4 6.63 <.010 <.075 .057 <15 NA 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceeaance for the same parameter at tale sallre vuuall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018.05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included In the Stormwater Pollution Prevention Plan." Re<k,(f� Name (Print name) n5E eot/ Title (Print title) Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/0 Parameter Code - 46529 NCOIL 00552 CO530 NA No vMOOe IviYnvrite fuiTAe1M mNe Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 |� \\ � El Wn