Loading...
HomeMy WebLinkAboutWQ0019782_Staff Gauge Certification_20210920Caudle, Caitlin From: Caudle, Caitlin Sent: Monday, September 20, 2021 1:48 PM To: Jamie Cosson Subject: RE: [External] Staff Gauge Thanks, Jamie! The surveyor's report will work. I would like to schedule a follow up inspection to review all of the follow up items and the staff gauge. I have nothing scheduled for the next couple of weeks. From: Jamie Cosson <jamie.cosson@ymcagreensboro.org> Sent: Monday, September 20, 2021 9:40 AM To: Caudle, Caitlin <caitlin.caudle@ncdenr.gov> Subject: [External] Staff Gauge CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hi Caitlin, I have attached a survey report showing elevations, the original engineering document from when the pond was installed and a picture of the gauge in the pond. The measurements look to be consistent. Is this everything you need or do you need something from the engineer specific to the gauge? Jamie Jamie Cosson Executive Director YMCA CAMP WEAVER 4924 Tapawingo Trail, Greensboro, NC 27406 (Ph) 336-697-0525 (E) jamie.cosson@ymcagreensboro.org (W) campweaver.org The Y: We're for youth development, healthy living and social responsibility. 1 Sacks Surveying & Mapping, P.C. 3308 B Edgefield RD, Greensboro, NC 27409 (336) 931-0566 stan(c�sackssurveyinq.com www.ssm.Iand Prepared: September 17, 2021 SACKS SURVEYING & MAPPIN( P.t:. SURVEY REPORT YMCA CAMP WEAVE-1— S'T' 11A7 GA GE ELEVATION 4924 Tapawingo Trail, Greensboro, NC 27406 I certify that on September 15th, 2021, a survey was performed under my responsible charge in compliance with the Standards of Practice for Land Surveying (21-56.1600) for YMCA of Greensboro, Inc. for the purpose of establishing benchmarks and elevations for a 75' by 150' +/- retention pond located upon the property of YMCA of Greensboro, Inc (Guilford County Tax Parcel 111 16415; Deed Book Reference: Deed Book 1595, Page 591; Plat Reference: Plat Book 146, Page 16). A boundary survey was not performed in conjunction with this elevation survey, and no effort was made to locate property lines, easements, or other boundary matters. Elevations were established at this site from GPS control points previously surveyed by Sacks Surveying & Mapping using rapid static GPS (VRS) methods with Spectra Precision SP-80 GPS equipment, holding local CORS Stations as a fixed horizontal and vertical reference. See Attachement A (page 2) to this report for GPS meta -data. Differential leveling using a Carl Zeiss auto -level was then used to measure elevations at the following locations: Pond benchmark: southwest corner of a metal access hatch on top of a concrete wet -well vault = 680.72' Invert elevation of said concrete wet -well vault = 669.57' Metal rebar set at the low point of the pond dam = 679.99' Bottom of a staff gauge in the center of the pond = 669.48' From these elevations, the following readings on the staff gauge can be determined: Bottom of pond = 0.00' 2 feet below the low point on the dam = + 8.51' At the low point on the dam = + 10.51' This 11 day of Sae T EM 8ER, 2021 (61.1)1 Signed ‘‘\‘‘ C A irit1/4 ._ , C- SEAL r L-4519 f rs-; %sr', oak. O.; driejeCIAtieS ?III nti\‘‘ Michael A. McKibbin, PLS L-4519 Sacks Surveying & Mapping (Firm LIC 11 C-2741) SURVEY REPORT YMCA CAMP WEAVER — STAFF GAUGE ELEVATION 4924 Tapawingo Trail, Greensboro, NC 27406 ATTACHMENT A - GPS Meta -data Class of Survey: A Positional Accuracy: 0.03' Horiz./Vert. 0.03' Type of GPS field procedure: Rapid Static (VRS) Date of Survey 09 April, 2021 Datum/Epoch: NAD 83 (2011) Vertical Datum: NAVD 88 Published/fixed-control used: Local CORS Stations Geoid Model: Geoid 18 Combined grid factor: 0.99993629 Units: US Survey Feet Local Survey Control Point Used: (SS&M point #10033): 60d Nail (SS&M point #10033): NC Grid Coordinates (I\ AD 83/2011) North (y) 828,865.10' East (x) 1,798,416.07' Elevation 659.80' (NAVD 88/Geoid 18) Survey control points were independently verified on 26 April, 2021 using a Trimble-5800 GPS receiver to perform a static observation of site control points which was post -processed using OPUS, yielding a positional accuracy of 0.03'. Page 2 685 680 675 3-1 FILL SLOPE (4' NATURAL GRD .ELEV, 679.4 3:1 FILL SLOPE (4' MIN. TOP WIDT1r) MIN. TOP WI9TH) 670 685 2' FREEBOARD TOP 115' OF BERM E4 EV. 681.0 EXISTING NATURAL GROUND. SIDE SLOPE 1: 1 TOP OF STORAGE ELEV. 679.0 1 ALLOWANCE FOR SOLIDS ACCUM',ULATi/N BOTTOM ELEV . 670.0 TOP ELEV. 680,0 " • DIP SANIT RY SEWER HINGED HALLIDA ACCESS DO0fR ✓ S 1 R3030, uR EQUAL 0 6 TO HYDRAULIC UNIT REDUCER 1 2" FOOT W/STRAIN NOTE: ALL SUCTI N PIPING T inn r ver ve HAL- BE SCH 80 EMOVABLE WITHOUT HAVING TO ENER ; WET WE VALVE =R 680 675 670 3: 1 FILL SLOPE (4' MIN. TOP WIDTH) 2' SCALE: 1 " = 10 HOR. 1 = 5' VER. FREEBOARD SECTION 'A --/ 70' TOP OF BERM ELEV. 681.0 , 'X90' BEND /SCREENED INLET INSIDE BOTTOM ELEV. 670.0 �r. T TOP OF STORAGE ELEV. 679.0 SIDE SLOPE 1:1 1' ALLOWANCE FOP SOLIDS ACCUMULATION BOTTOM ELEV 670, 0 3.1 FILL SLOP (4' MIN. TOP. Y✓IDTH) 4' DIAMETER WET WELL FOR PUMPING TO APPL /CATION .AREA (NTS) PUMPS FOR HYDRAULIC, UNIT HALL BE STA—RITE DHH, 3 HP, . OR EQqA L 20 MIL POLYETHYLENE L DURA---SKIRM R20WW BY RAVEN INDUSTRIES,. C ER R EQUAL SECTION "B -BI> NOTE: LAGOONS LL BE LINED WITH A MINIMUM OF 4Q MIL HDPE INER, IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS AND RECOMMENDA IONS TRANSFEf? PUMP STATION AND LAGOON DETAIL FOR GATE ELEV. 662.0 10' r ELEV. 658.0 l� 4' INLET PIPE HIGH WATER ALAR1A-6.Q PUMP 12 ON-655.5 PUMP j1 ON-ELEV. 655.0 PUMPS OFF-ELEV.. 653.0 ELEV. 652.0 FLASHING ALARM LIGHT WEATHERPROOF NELEA 4X CONTROL BOX POWER SUPPLY CONDUIT CORD SEAL CONNECTORS FOR POWER AND CONTROL CORDS �- HINGED ACCESS DOOR iHALLE:JAY 51R3030, OR EQUAL TOP RAIL SUPPORT (BOLTS TO COVER FRAME) LIFTING CHAIN 2" GATE VALVE 3' DISCHARGE PIPING 2" TRU-UNION 2' CHECK VALVE DISCHARGE LEVEL BELOW FROM LINE INTERMEDIATE RAIL SUPPORT (ONE REQUIRED FOR EACH 12 FEET OF BASIN DEPTH IN EXCESS OF 12 FEET.) 2" DISCHARGE PIPING 3/4' PIPE GUIDE RAILS MUST BE PLL1M8 MODEL MYERS MW150, OR EQUAL SUBMERSIBLE SEWAGE PUMP LIFT -OUT ASSEMBLY (SRA-200) BOTTOM OF BASIN MUST HAVE SMOOTH TROWELED SURFACE FOR MTG. SUPPORT CASTING DUPLEX TRANSFER PUMP STATION GUILFORD COUNTY OUTDOOR YMCA CENTER GUILFORO COUNTY, NC -FINALDESICIN NOT RELEASED. FOR I'ON iRSJ TICK DALTON ENGINEERING & ASSOCIATES, P.A. 446 EAST MAIN STREET P.O. BOX 426 CLAYTON, NC 27520 41011111.. (919)550-4740 (919)550-4741 FAX JOB: 00084, FILE: DATE: 3/13/01. DRAWN: DBL REVISION: SHEET: 6 OF 7 • w.; • t. �~ f �•�• ...1:::1 - - . • l :A:::‘ 11. rf. •a . • "t\gi 11:1";:::;11.11•111:. -a^-w: 'Cs14't'r'(1'S 3J� _ ✓ r+, y et.}s i , .., ram S^ .: 1, • . C., i ..<.i - / /\ MIS-Y`- •• a • �ti.J 1 [✓ _ ° Si. > i ✓.. O ' : /° ✓ yr- .°: - - 1,.rL4 sit!,111 r / tn.40 •Ta. Ia • Y A l r° f /. �.�" Y 1 J • �q il. . / Pr->. -Ca usy licitt-o; r • 1 1 i r - K• Y 1