HomeMy WebLinkAboutNCG551378_Inspection_20210914United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection 1 Ins I 2 LI 3 I NCG551378 111 121 21/09/14 117 Type 18 I r! I I� I 1 1 Inspector Fac Type 19 I c I 201 I 211 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 I I I 1 I I I I I I I I L1 1 1 1 I 1 1.166 Inspection Work Days Facility Self -Monitoring Evaluation Rating 61 QA----------------------Reserved------------------- 671 1701 LJ I 711 I 72 I N I 73I I I74 71 1 1 1 I 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 802 Walsenburg Drive 802 Walsenburg Durham NC 27712 Entry Time/Date 03:15PM 21/09/14 Permit Effective Date 13/08/01 Exit Time/Date 04:OOPM 21/09/14 Permit Expiration Date 18/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /1/ — Other Facility Data Name, Address of Responsible OtficialMtle/Phone and Fax Number Contacted' Sylvester Brown,802 Walsenburg Dr Durham NC 2771211919-732-2681/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jane Bernard DWR/Non Discharge Compliance Unit/919-791-42001 i i?/026-/.2( i Signature of Manag ent Q A Reviewer Agency/Office/Phone and Fax Numbers Date 7l EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 3I NPDES yrlmolday NCG551378 111 11 21/09/15 J17 Inspection Type 181r-, (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) 1 Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. The septic tank was pumped on March 29, 2021. 1 Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the environment. The product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, including...disinfection units...at all times and in good operating order. Only use wastewater approved tablets in the chlorinator as required by the General NPDES Permit. 1 Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Nitrogen, Ammonia, Total Phosphorous and Total Residual Chlorine. During the inspection, you informed the inspector that there is not enough flow to sample. Please monitor the effluent pipe during heavy use, if a flow is observed please make arrangements to sample during heavy use times. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 1 Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The discharge pipe was visible and accessible the day of the inspection. Please continue to ensure the outlet is always visible/maintained and cleared of vegetation, soil and leaves Page# 2