Loading...
HomeMy WebLinkAboutWQ0032515_Final Permit_20210909 September 9, 2021 D ONALD F. G REELEY D IRECTOR W ATER M ANAGEMENT C ITY OF D URHAM 101 C ITY H ALL P LAZA D URHAM, N ORTH C AROLINA 27701 Subject: Permit No. WQ0032515 North Durham WRF Reclaimed Water Generation and Bulk Distribution System Durham County Dear Mr. Greeley: In accordance with your permit renewal request received July 15, 2021, we are forwarding herewith Permit No. WQ0032515 dated September 9, 2021, to the City of Durham for the continued operation of the subject reclaimed water generation and bulk distribution facilities. Please note that this renewed permit shall become effective on December 1, 2021 (i.e., the day after the expiration date of the existing permit). This permit shall be effective from December 1, 2021 through January 31, 2028, shall void Permit No. WQ0032515 issued November 19, 2020, and shall be subject to the conditions and limitations therein. The Permittee shall submit a renewal application no later than August 4, 2027. Please pay attention to the monitoring requirements listed Attachments A and D for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. The following permit condition is new since the last permit issuance dated November 19, 2020: Condition IV.6. The Permittee shall provide to its users and the Division of Water Resources an annual report summarizing the performance of the reclaimed water generation facility and the extent to which the facility has violated this permit, or federal or State laws, regulations, or rules related to the protection of water quality. If any parts, requirements, or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Otherwise, this permit shall be final and binding. Mr. Donald F. Greeley September 9, 2021 Page 2 of 2 If you need additional information concerning this permit, please contact Vivien Zhong at (919) 707-3627 or vivien.zhong@ncdenr.gov. Sincerely, S. Daniel Smith, Director Division of Water Resources cc: Durham County Health Department (Electronic Copy) Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH RECLAIMED WATER GENERATION AND BULK DISTRIBUTION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO City of Durham Durham County FOR THE continued operation of a reclaimed water generation and bulk distribution facility consisting of the: installation of: an on-line turbidimeter; and all associated piping, valves, controls, and appurtenances; and the continued operation of reclaimed water generation from NPDES Permit No. NC0023841; two variable frequency drive (VFD) pumps to maintain pressure to the distribution system; a 4-inch overhead loading arm; a 3-inch quick connect fitting at ground level for distribution to customers; a sodium hypochlorite feed system with bulk tank with meter pump to supply chlorine to the pump feed system; a manual valve at the loading station with a hand held turbidimeter (for use prior to installation of on-line turbidimeter), flow meter, and residual chlorine monitor; a catch basin that drains to the headworks; a reclaimed water bulk distribution system consisting of: Fill Station Location Owner County Latitude Longitude 1 North Durham WRF City of Durham Durham 36.027598° -78.864587° and all associated piping, valves, controls, and appurtenances to serve the North Durham WRF, with no discharge of wastes to surface waters, pursuant to the application received July 15, 2021, and in conformity with the Division-approved plans and specifications considered a part of this permit. This permit shall be effective from December 1, 2021 through January 31, 2028, shall void Permit No. WQ0032515 issued November 19, 2020, and shall be subject to the following conditions and limitations: WQ0032515 Version 3.0 Shell Version 200201 Page 1 of 9 I. SCHEDULES 1. Prior to distribution to Mist Lake (PPI 003), the Permittee shall install an on-line turbidimeter to continuously monitor and record turbidity that is representative of both PPI 002 and PPI 003, and an As-Built Plan showing the location of the turbidimeter shall be submitted for review. The plan shall be sent to the Division of Water Resources, Non-Discharge Branch, 1617 Mail Service Center, Raleigh, NC 27699-1617 or Non-Discharge.Reports@ncdenr.gov. \[15A NCAC 02U .0401(b)\] 2. The Permittee shall request renewal of this permit on Division-approved forms no later than August 4, 2027. \[15A NCAC 02T .0105(b), 02T .0109\] II. PERFORMANCE STANDARDS 1. The Permittee shall maintain and operate the subject reclaimed water facilities so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, the Permittee shall take immediate corrective actions, including Division required actions, such as the construction of additional or replacement reclaimed water generation and utilization facilities, or cessation of reclaimed water utilization activities. \[15A NCAC 02T .0108(b)(1)(A)\] 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. \[15A NCAC 02T .0108(b)(1)(A)\] 3. Effluent limitations for generated reclaimed water shall not exceed those specified in Attachment A. \[15A NCAC 02U .0301\] 4. Bulk distributed reclaimed water shall only be utilized in accordance with the approved uses specified in Attachment D. \[15A NCAC 02T .0108(b)(1)(A)\] 5. The conjunctive utilization of bulk distributed reclaimed water permitted herein in no way negates, precludes, or invalidates Permit No. NC0023841. \[15A NCAC 02T .0108(b)(1)(A)\] 6. All reclaimed water valves, storage facilities, and outlets shall be tagged or labeled to warn the public or employees that the water is not intended for drinking. \[15A NCAC 02U .0403(b)\] 7. All reclaimed water piping, valves, outlets, and other appurtenances shall be color-coded, taped, or otherwise marked to identify the source of the water as being reclaimed water as follows: a. All reclaimed water piping and appurtenances shall be either colored purple (Pantone 522 or equivalent) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER - DO NOT DRINK" or be installed with a purple (Pantone 522 or equivalent) identification tape or polyethylene vinyl wrap. The warning shall be stamped on opposite sides of the pipe and repeated every three feet or less; b. Identification tape shall be at least three inches wide and have white or black lettering on purple (Pantone 522 or equivalent) field stating "CAUTION: RECLAIMED WATER - DO NOT DRINK". Identification tape shall be installed on top of reclaimed water pipelines, fastened at least every 10 feet to each pipe length and run continuously the entire length of the pipe; and c. Existing underground distribution systems retrofitted for the purpose of conveying reclaimed water shall be taped or otherwise identified as noted in II.7.a. and II.7.b. This identification need not extend the entire length of the distribution system but shall be incorporated within 10 feet of crossing any potable water supply line or sanitary sewer line. \[15A NCAC 02U .0403(c)\] WQ0032515 Version 3.0 Shell Version 200201 Page 2 of 9 8. All reclaimed water valves and outlets shall be of a type, or secured in a manner, that permits operation by personnel authorized by the entity that operates the reclaimed water system. \[15A NCAC 02U .0403(d)\] 9. Hose bibs shall be located in locked, below grade vaults that shall be labeled as being of non-potable quality. As an alternative to the use of locked vaults with standard hose bib services, other locking mechanisms such as hose bibs that can only be operated by a tool may be placed above ground and labeled as non-potable water. \[15A NCAC 02U .0403(e)\] 10. There shall be no direct cross-connections between the reclaimed water and potable water systems, unless such connection has been approved by the Department pursuant to 15A NCAC 18C .0406. \[15A NCAC 02U .0403(f)\] 11. The facilities herein were permitted per the following setbacks: a. The storage and treatment units were originally permitted December 21, 2007. The setbacks for storage and treatment units originally permitted or modified from September 1, 2006 to June 17, 2011 are as follows (all distances in feet): 1 i. Each habitable residence or place of assembly under separate ownership: 100 ii. Each private or public water supply source: 100 iii. Surface waters: 50 iv. Each well with exception of monitoring wells: 100 2 v. Each property line: 50 1 Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. \[15A NCAC 02T .0912(a)\] WQ0032515 Version 3.0 Shell Version 200201 Page 3 of 9 III. OPERATION AND MAINTENANCE REQUIREMENTS 1. The Permittee shall operate and maintain the subject facilities as a non-discharge system. \[15A NCAC 02U .0101\] 2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include: a. A description of the operation of the system in detail to show what operations are necessary for the system to function and by whom the operations are to be conducted; b. A sampling and monitoring plan to evaluate quality of reclaimed water within the bulk distribution system to provide quality assurance at the time of reuse, and specify actions to be taken in response to unsatisfactory monitoring results; c. A map of all reclaimed water bulk distribution points; d. A description of anticipated maintenance of the system; e. Provisions for safety measures, including restriction of access to the site and equipment; f. Spill control provisions that include response to upsets and bypasses, including control, containment, and remediation, and contact information for personnel, emergency responders, and regulatory agencies; g. Approval procedures for bulk distribution users; h. Operational requirements for bulk distribution users; and i. A description of how compliance with reclaimed water quality standards will be ensured the time of use if bulk distributed reclaimed water is stored for greater than 72 hours prior to use. \[15A NCAC 02U .0801(a)\] 3. classification of the subject non-discharge facilities, the Permittee shall designate and employ a certified operator in responsible charge (ORC), and one or more certified operators as back-up ORCs. The ORC or their back-up shall operate and visit the facilities as required by the WPCSOCC. \[15A NCAC 02T .0117\] 4. An operator certified by the Water Pollution Control System Operators Certification Commission (WPCSOCC) of a grade equivalent or greater than the facility classification shall be on call 24 hours per day. \[15A NCAC 02U .0401(e)\] 5. Only reclaimed water generated from the North Durham WRF (Permit No. NC0023841) shall be utilized at the sites and for the activities specified in Attachment B. \[15A NCAC 02U .0101\] 6. The Permittee shall prohibit public access to the wastewater treatment and storage facilities. \[15A NCAC 02T .0108(b)(1)(A)\] 7. The Permittee shall dispose or utilize generated residuals in a Division-approved manner. \[15A NCAC 02T .1100, 02U .0802\]. 8. The Permittee shall not divert or bypass untreated or partially treated reclaimed water from the subject facilities unless diverted to an alternate treatment or collection system. \[15A NCAC 02T .0108(b)(1)(A)\] 9. Metering equipment shall be tested and calibrated annually. \[15A NCAC 02U .0801(d)\] 10. An automatically activated standby power source or other means to prevent improperly treated wastewater from entering the storage, distribution, or utilization system shall be provided. \[15A NCAC 02U .0401(d)\] WQ0032515 Version 3.0 Shell Version 200201 Page 4 of 9 11. Reclaimed water shall not be bulk distributed if turbidity exceeds 10 NTUs or if the permitted pathogen levels cannot be met. \[15A NCAC 02U .0401(c)\] 12. Continuous online monitoring and recording for turbidity or particle count and flow shall be provided prior to storage, distribution, or utilization of reclaimed water. \[15A NCAC 02U .0401(b)\] 13. If turbidity exceeds 10 NTUs or if the permitted pathogen levels cannot be met, all effluent shall be prohibited from entering the storage, distribution, or utilization system, and shall be disposed of in accordance with Permit No. NC0023841 until the reclaimed water standards are met at the generating facility. \[15A NCAC 02U .0401(c)\] 14. The Permittee shall provide notification to the public and its employees about the use of reclaimed water, and that reclaimed water is not intended for drinking. Such notification shall be provided to employees in a language they can understand. \[15A NCAC 02U .0501(a)(2)\] 15. Bulk distributed reclaimed water used for activities other than irrigation shall not be used in a manner that causes exposure to aerosols. \[15A NCAC 02U .0501(b)(6)\] 16. Bulk distributed reclaimed water shall not be used for swimming pools, hot tubs, spas, or similar uses. \[15A NCAC 02U .0501(c)\] 17. Tank trucks and other equipment used to transport bulk distributed reclaimed water shall be identified with advisory signs stating that they contain reclaimed water that is not intended for drinking. \[15A NCAC 02U .0601(a)\] 18. Tank trucks used to transport bulk distributed reclaimed water shall not be used to transport potable water. \[15A NCAC 02U .0601(b)\] 19. Tank trucks used to transport bulk distributed reclaimed water shall not be filled through on-board piping or removable hoses that may subsequently be used to fill potable water tanks. \[15A NCAC 02U .0601(c)\] 20. The Permittee shall develop and implement an education program to inform users and its employees about the proper use of reclaimed water. Educational material shall be provided to all residents and/or other facilities provided with reclaimed water, and these materials shall be maintained consistent with the reclaimed water uses. All educational materials shall be made available to the Division upon request. \[15A NCAC 02U .0501(a)(4)\] 21. The Permittee shall develop and maintain a record keeping program for the bulk distribution of reclaimed water. \[15A NCAC 02U .0601(e)\] 22. The Permittee shall develop and maintain a routine review and inspection program of those accepting bulk distributed reclaimed water. \[15A NCAC 02U .0601(f)\] WQ0032515 Version 3.0 Shell Version 200201 Page 5 of 9 IV. MONITORING AND REPORTING REQUIREMENTS 1. The Permittee shall conduct and report any Division required monitoring necessary to evaluate this groundwater and surface water. \[15A NCAC 02T .0108(c)\] 2. A Division-certified laboratory shall conduct all analyses for the required effluent, groundwater, and surface water parameters. \[15A NCAC 02H .0800\] 3. The Permittee shall monitor the bulk distributed reclaimed water at the frequencies and locations for the parameters specified in Attachment A. \[15A NCAC 02T .0108(c)\] 4. The Permittee shall maintain records tracking the amount of reclaimed water bulk distributed to each user and shall include the following information: a. Date and time of bulk distribution event; b. Name of receiver or town-issued bulk fill certification number; c. Intended use of the bulk distributed reclaimed water; d. Volume of reclaimed water per each bulk distribution event; and e. Monthly total volume of reclaimed water bulk distributed. Monthly tracking records for all users shall be summed and reported on Form NDMR. This value shall represent the total volume of reclaimed water bulk distributed to all users for that month. \[15A NCAC 02T .0108(c)\] 5. Three copies of all monitoring data (as specified in Conditions IV.3. and IV.4.) on Form NDMR for each PPI and shall be submitted on or before the last day of the following month. If no activities occurred during the monitoring month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 \[15A NCAC 02T .0105(l)\] 6. Pursuant to G.S. 143-215.1C(a), the Permittee shall provide to its users and the Division of Water Resources an annual report summarizing the performance of the reclaimed water generation facility and the extent to which the facility has violated this permit, or federal or State laws, regulations, or rules related to the protection of water quality. This report shall be prepared on either a calendar or fiscal year basis and shall be provided no later than 60 days after the end of the calendar or fiscal year. Two Division of Water Resources Water Quality Permitting Section 1617 Mail Service Center Raleigh, North Carolina 27699-1617 \[G.S. 143-215.1C(a)\] 7. The Permittee shall maintain a record of all residuals removed from this facility. This record shall be maintained for five years, and shall be made available to the Division upon request. This record shall include: a. Name of the residuals hauler; b. Non-Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. \[15A NCAC 02U .0802(b)\] WQ0032515 Version 3.0 Shell Version 200201 Page 6 of 9 8. A maintenance log shall be kept at this facility. This log shall be maintained for five years, and shall be made available to the Division upon request. This log shall include: a. Date of flow measurement device calibration; b. Date of turbidimeter calibration; c. Visual observations of the bulk distribution facilities; d. Visual observations of the plant and plant site; and e. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections and cleanings, etc.); and f. Record of all discharges of reclaimed water to surface waters or the land surface, including the date of occurrence, estimated volume, and corrective action taken. \[15A NCAC 02U .0801(h)\] 9. Noncompliance Notification: The Permittee shall report to the Raleigh Regional Office, telephone number (919) 791-4200, within 24 hours of first knowledge of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, etc.) rendering the facility incapable of adequate wastewater treatment. c. Any failure rendering the reclaimed water bulk distribution facilities incapable of adequately conveying reclaimed water (e.g., mechanical or electrical failures, etc.). d. Any failure resulting in a discharge untreated or partially treated wastewater to surface waters. e. Any failure resulting in a discharge of reclaimed water directly to surface waters or any unpermitted release of reclaimed water to land surface greater than or equal to 5,000 gallons. Unpermitted releases less than 5,000 gallons to land surface shall be documented by the Permittee in accordance with Condition IV.8.f. but do not require Regional Office notification. f. Any time self-monitoring indicates the facility has gone out of compliance with its permit limitations. Emergencies requiring reporting outside normal business hours shall call Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. All noncompliance notifications shall file a written report to the Raleigh Regional Office within five days of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not recur. \[15A NCAC 02T .0108(b)(l)(A)\] WQ0032515 Version 3.0 Shell Version 200201 Page 7 of 9 V. INSPECTIONS 1. The Permittee shall perform inspections and maintenance to ensure proper operation of the reclaimed water generation and bulk distribution facilities. \[15A NCAC 02U .0801(i)\] 2. The Permittee shall inspect the reclaimed water generation and bulk distribution facilities to prevent malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection log that includes the date and time of inspection, observations made, and maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. \[15A NCAC 02U .0801(h), 02U .0801(i)\] 3. Division authorized representatives may, upon presentation of credentials, enter and inspect any property, premises, or place related to the reclaimed water generation and bulk distribution facilities permitted herein at any reasonable time for determining compliance with this permit. Division authorized representatives may inspect or copy records maintained under the terms and conditions of this permit, and may collect groundwater, surface water, or leachate samples. \[G.S. 143-215.3(a)(2)\] 4. The Permittee shall inspect the utilization sites of all reclaimed water users who obtain more than 10,000 gallons per day of bulk distributed reclaimed water. Permittee inspection of these bulk distribution reclaimed water utilization sites shall need to exceed one inspection per quarter. The Permittee shall maintain records of these inspections for five years, and shall make them available to the Division upon request. \[15A NCAC 02T .0108(b)(1)(A)\] VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to a Division enforcement action. \[G.S. 143-215.6A, 143-215.6B, 143-215.6C\] 2. This permit is effective only with respect to the nature and volume of wastes described in the permit application, and Division-approved plans and specifications. \[G.S. 143-215.1(d)\] 3. Unless specifically requested and approved in this permit, there are no variances to administrative codes or general statutes governing the construction or operation of the facilities permitted herein. \[15A NCAC 02T .0105(n)\] 4. The issuance of this permit does not exempt the Permittee from complying with all statutes, rules, regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require. \[15A NCAC 02T .0105(c)(6)\] 5. If the permitted facilities change ownership, or the Permittee changes their name, the Permittee shall submit a permit modification request on Division-approved forms. The Permittee shall comply with all terms and conditions of this permit until the permit is transferred to the successor-owner. \[G.S. 143- 215.1(d3)\] 6. The Permittee shall retain a set of Division-approved plans and specifications for the life of the facilities permitted herein. \[15A NCAC 02T .0105(o)\] 7. The Permittee shall maintain this permit until the proper closure of all facilities permitted herein, or until the facilities permitted herein are permitted by another authority. \[15A NCAC 02T .0105(j)\] WQ0032515 Version 3.0 Shell Version 200201 Page 8 of 9 8. This permit is subject to revocation or modification upon 60-day notice from the Division Director, in whole or part for: a. violation of any terms or conditions of this permit or Administrative Code Title 15A Subchapter 02U; b. obtaining a permit by misrepresentation or failure to disclose all relevant facts; c. i. to enter the where a system is located or where any records are required to be kept; ii. to have access to any permit required documents and records; iii. to inspect any monitoring equipment or method as required in this permit; or iv. to sample any pollutants; d. ee for administering and compliance monitoring; or e. a Division determination that the conditions of this permit are in conflict with North Carolina Administrative Code or General Statutes. \[15A NCAC 02T .0110\] 9. Unless the Division Director grants a variance, expansion of the facilities permitted herein shall not occur if any of the following apply: a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of environmental crimes under G.S. 143-215.6B, or under Federal law that would otherwise be prosecuted under G.S. 143-215.6B, and all appeals of this conviction have been abandoned or exhausted. b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned a wastewater treatment facility without properly closing the facility. c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil penalty, and all appeals of this penalty have been abandoned or exhausted. d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant with any compliance schedule in a permit, settlement agreement, or order. e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual fee. \[15A NCAC 02T .0120(b), 02T .0120(d)\] 10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. \[15A NCAC 02T .0120(c)\] th Permit issued this the 9 day of September 2021 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ____________________________________________ S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0032515 WQ0032515 Version 3.0 Shell Version 200201 Page 9 of 9 THIS PAGE BLANK 1 3.0 of 1 1 Page Grab TypeTypeType Version: SampleSampleSample EstimateEstimate Recorder CompositeCompositeComposite . 1 32515 MonthlyMonthly 2 x Week2 x Week2 x Week2 x Week FrequencyFrequencyFrequency Continuous MONITORING REQUIREMENTSMONITORING REQUIREMENTS MeasurementMeasurementMeasurement MONITORING REQUIREMENTS line turbidimeter - 6 15102510 Daily MaximumDaily MaximumDaily Maximum Permit Number: WQ00 Permit No. NC0023841. s. Daily MinimumDaily MinimumDaily Minimum A 14 Monthly Monthly Monthly Geometric MeanGeometric MeanGeometric Mean EFFLUENT LIMITSEFFLUENT LIMITSEFFLUENT LIMITS Attachment line turbidimeter and continuous after the installation of the on - 45 10 Average Monthly Monthly TotalMonthly Total NTU mg/Lmg/Lmg/L GallonsGallons Units of Units of Units of MeasureMeasureMeasure #/100 mL Distribution readings at PPI 002 are reflective of what is sent to PPI 003. FC Broth, 44.5 ºC - LIMITATIONS AND MONITORING REQUIREMENTS 3.0 Parameter DescriptionParameter DescriptionParameter Description frequency for Turbidity is per event prior to the installation of the on Day (20 ºC) - Version Reclaimed Water Bulk Mist Lake Reclaimed Water Generation System Effluent BOD, 5Nitrogen, Ammonia Total (as N)Solids, Total SuspendedColiform, Fecal MF, MFlow, Reclaimed Water DistributedTurbidity, HCH TurbidimeterFlow, Reclaimed Water Distributed EFFLUENT CHARACTERISTICSEFFLUENT CHARACTERISTICSEFFLUENT CHARACTERISTICS 3 32515 001 de The monitoring requirements (i.e., measurement frequency and sample type) have been aligned with those requirements in The monitoring The Fecal Coliform and Turbidity PCS PCS PCS CoCodeCode 003100061000530 PI 002 3161600076 PI 00 WQ01WQ01 ATTACHMENT A PPI 1.2.P 1.P 1.WQ00 THIS PAGE BLANK -1 3.0 - of s of 1 Page Version: .2200 to 15A NCAC 02C - 32515 . freezing. synthetic clay tennis courts, or similar. off of the reclaimed water occurs. - receiving reclaimed water Permit Number: WQ00 prior to ADDITIONAL REQUIREMENTS AND COMMENTSADDITIONAL REQUIREMENTS AND COMMENTS ed certifi - D Must meet Public Water Supply requirements per 15A NCAC 18C .0100 Provided the water is returned to the sanitary sewer, or used for other approved reclaimed water uses after testing.Provided that no ponding or run Provided that cooling water or boiler blow down water is disposed of according to any necessary disposal permit. Brine slurry to be applied to roads to prevent Provided that all conditions of 15A NCAC 02U .1401 are met.Use of reclaimed water does not exempt user from meeting the use and disposal requirementthe created solution.Must meet compost permit requirements. May include irrigation to clay or Does not include borings into bedrock or installation of any wells subjectWell Construction Regulations.Provided that dual disinfection with UV and chlorination is provided, and that no ponding or runoff of the reclaimed water occurs. be Permittee 2 Attachment reclaimed water. potable - distributed bulk 1 utilizing USES rior to p users shall complete educational training and pressure testing sanitary sewer systems PERMITTEE APPROVED APPROVED RECLAIMED WATER BULK DISTRIBUTION USES mplete educational training power washing 3.0 North Durham WRF D shall co Version seeding and fertilizer mixing up water for brine slurry or similarup water for preparation of pesticide solutions or similar - -- potable processes such as asphalt reclamation, concrete production and compost - Durham employees recipients of bulk distributed reclaimed water 32515 Firefighting and fire extinguishing Reclaimed water distribution line flushing and Vehicle and equipment washing Concrete cuttingDecorative ponds and fountains that drain to HydroIndustrial and commercial cooling water or boiler blow down waterIndustrial and commercial fire prevention systems where there are separate nonplumbing linesIrrigation of public and private landscapes and turfMakeIrrigation of food chain cropsMakeNonproduction Sewer cleaningSoil compaction and dust suppressionStreet sweeping and washingSubsurface Directional BoringVehicle washing and All All APPROVED USES FOR BULK DISTRIBUTED RECLAIMED WATER RECIPIENTS ATTACHMENT City of 1.2.WQ00