Loading...
HomeMy WebLinkAboutWQ0028666_Compliance Evaluation Inspection_20210916Compliance Inspection Report Permit: WQ0028666 Effective: 08/12/19 Expiration: 08/31/24 Owner : Aqua North Carolina Inc SOC: Effective: Expiration: Facility: Cannonsgate at Bogue Sound WWTP County: Carteret 4201 Hwy 24 Region: Wilmington Newport NC 28570 Contact Person: Joel A Mingus Title: Coastal Area Manager Phone: 910-270-1412 Directions to Facility: Travel Hwy 24E from Cedar Point to Ocean. Turn R across from West Carteret Water Corp. System Classifications: WW3., Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative Raymond L Braxton 910-431-9248 Related Permits: WQ0037078 Aqua North Carolina Inc - Bogue Watch to Cannonsgate WWTP Interconnect WQ0029821 Aqua North Carolina Inc - Bogue Watch WWTP Inspection Date: 09/16/2021 Entry Time 09:OOAM Exit Time: 11:OOAM Primary Inspector: Brian S West Phone: 910-796-7341 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant Not Compliant Question Areas: ▪ Miscellaneous Questions ▪ Treatment Lagoons ▪ Storage (See attachment summary) ▪ Treatment ▪ Treatment Disinfection ▪ Standby Power ▪ Record Keeping ▪ End Use -Infiltration ▪ Wells Page 1 of 5 Permit: WQ0028666 Owner - Facility:Aqua North Carolina Inc Inspection Date: 09/16/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Routine inspection with Raymond Braxton. Please see comments under individual sections of this report and address as required. Please let us know if there are any questions regarding this report Page 2 of 5 Permit: WQ0028666 Owner - Facility:Aqua North Carolina Inc Inspection Date: 09/16/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Recycle/Reuse Single Family Drip Activated Sludge Drip, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Single Family Spray, LR Lagoon Spray, LR Reuse (Quality) Infiltration System Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Yes No NA NE • Yes No NA NE • ❑ ❑ ❑ Comment: Facility also adds chlorine although the permit does not require it. The odor control system is not in operation. The plant treatment units are completely enclosed; there is no noticeable odor at the facility. Efficacy of plant total nitrogen removal is marginal, but permit does not have total nitrogen limits and monitoring well data has not shown significant nitrate levels. Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Comment: Generator is tested weekly under load Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Page 3 of 5 Permit: WQ0028666 Owner - Facility:Aqua North Carolina Inc Inspection Date: 09/16/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? ❑ ❑ • ❑ Yes No NA NE ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Comment: Monitoring well no. 6 routinely exceeds the NH3 limit. There is no indication the measured well levels are associated with plant effluent as the plant NH3 levels reported are typically below detection or barely measurable. Page 4 of 5 Permit: WQ0028666 Owner - Facility:Aqua North Carolina Inc Inspection Date: 09/16/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine End Use -Infiltration # Is the application High Rate or Low Rate? Are buffers maintained? Are any supply wells within the CB? Are any supply wells within 250' of the CB? Is municipal water available in the area? Are GW monitoring wells required? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Is a usable green area maintained? Is the disposal site acceptable? Is the distribution equipment acceptable? Is the disposal site free of ponding? Is the disposal site free of breakout? Are the disposal sites free of solids, algae, etc.? Do the records show that the fields are properly maintained? Are the disposal sites free of vegetation? Do any surface water features appear to be adversely impacted by GW discharge? No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? Yes No NA NE High Rate • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Comment: Effluent flow and turbidity meters are calibrated annually; flow to each basin is controlled automatically. Adequate storage freeboard was observed in the 5 day upset pond and infiltration basins. Aqua has received several complaints from residents regarding color of the water in the basins due to algal growth. Aqua reps have been communicating with DWR re options to control the algal growth. Permit condition 111(7) requires public access to the basins to be prohibited. Page 5 of 5