Loading...
HomeMy WebLinkAboutSW3210803_Plansheet - Misc. Detail_20210915LTITJ 11: 1 a lo I =I a L, EOXL9 laknin =I mil zi zi 1:10T."Tel m ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER 10'-O"MIN. F-A 0 CD CD CD 0 SANDBAGS P.) OR STAPLET 0 1- 0 Z 9 0 10 MIL PLASTIC - SANDBAGS LINING SIDE SLOPE OR STAPLEATY 0 9 0 0 CD CID 0 CD LA Eli- - CLEARLY MARKED SIGNAGE SECTION A -A CONCRETE NOTING DEVICE (18"X24' MIN.) WASHOUT NOTES 77�� 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. PLAN &CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE HIGH 10'-O"MIN. SANDBAGSTP.) COHESIVE & p-B 6R STAPIE' OR STAPLE LOW FILTRATION HIGH HIGH SOIL BERM 10 MIL 10 MIL COHESIVE & COHESIVE & 0 CD CD 0 PLASTIC LINING LOW FILTRATION PLASTIC LINING LOW FILTRATION 1:1 SIDE SLOPE SOIL BERM �j SIDE SLOPE SOIL BERM 0 0 YP (TYP.) 0 0 < > z X X 5 - 5< 0 0 t4 0 2'-0" CD CD SECTION B-B LB SANDBAGS P.) NOTES: OR STAPLEP 1. ACTUAL LOCATION DETERMINED IN FIELD CLEARLY MARKED SIGNAGE 2. THE CONCRETE WASHOUT STRUCTURES CONCRETE NOTING DEVICE (18 X24- MIN SHALL BE MAINTAINED WHEN THE LIQUID WASHOUT AND/OR SOLID REACHES 75% OF THE 77�� STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WITH A MINIMUM 12 INCHES OF FREEBOARD. PLAN &CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUT DETAIL NOT TO SCALE \VFILL SLOPE (3:1 MAX.) SIDE SLOPE (3:1 TYP.) 2' MIN. 7 FINISH GRAD NATURAL GROUND L/ 2' MIN. L/ I(BORROW AREA) I N COMPACTED BERM DEPTH OF TEMPORARY DITCH, BOTTOM WIDTH (VARIES) NOTE: 1. DITCH SHOULD HAVE MINIMUM LONGITUDINAL SLOPE OF 0.5%. 2. SILT FENCE MAY BE REQUIRED BEHIND BERM. 3. STABILIZE, SEED, AND MULCH IMMEDIATELY AFTER INSTALLATION. 4. LINERS SELECTED SHALL MEET OR EXCEED REQUIRED SHEAR STRESS SHOWN IN TABLE BELOW. TEMPORARY DITCH MAINTENANCE NOTE: INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. DEPTH (FT) TOP WIDTH (FT) *BOTTOM WIDTH (FT) SIDE SLOPE (H:V) CHANNEL LINING TYPE SHEAR STRESS (PS F) SLOPE (FT/FT) AREA (ACRES) LENGTH (FT) CWD #1 1.50 10.00 1.00 3 STRAW W/NET 1.17 0.045 0.70 218 CWD #2A 1.50 10.00 1.00 3 SYNTHETIC MAT 0.68 0.020 1.51 420 CWD #2B 1 1.50 10.00 1.00 3 SYNTHETIC MAT 1.98 0.070 1.88 1 270 TDD #1 1.50 10.00 1.00 3 STRAW W/NET 0.90 0.050 0.20 210 TDD #2 1.50 10.00 1.00 3 SYNTHETIC MAT 1.12 0.071 0.33 311 TDD#3 1.50 10.00 1.00 3 STRAW W/NET 0.23 0.011 0.13 98 TDD#4 1.50 10.00 1.00 3 SYNTHETIC MAT 0.63 0.038 0.27 296 TDD#5 1.50 10.00 1.00 3 STRAW W/NET 0.81 0.055 0.14 202 TDD#6 1.50 10.00 1.00 3 SYNTHETIC MAT 1.23 0.111 0.21 341 TDD#7 1.50 10.00 1.00 3 STRAW W/NET 0.87 0.083 0.09 112 TDD#8 1.50 10.00 1.00 3 STRAW W/NET 0.89 0.055 0.17 201 *SYNTHETIC MAT SHALL BE AMERICAN EXCELSIOR CURLEX 11 MAT OR APPROVED EQUAL TEMPORARY DIVERSION DITCH (TDD) I CLEAN WATER DITCH (CWD). NOT TO SCALE I IS I ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDEQ 09110120211 1 A I ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDOT 08104 1 REV.NO. I DESCRIPTIONS DATE 2 CLASS B RIP RAP-,,, 1 1 A AND B ARE AT EQUAL ELEVATIONS V-6" MIN. 4' TO 6' CROSS SECTION # 5 WASHED STONE FLOW 21, MAX AT CENTER PLAN GENERAL NOTES: 1. RIPRAP SIZE TO BE DESIGNED BY ENGINEER. 2. CHECK DAMS MAY BE USED IN SLOPING DITCHES OR CHANNELS TO SLOW VELOCITY OR TO CREATE SEDIMENT TRAPS. 3. ENSURE THAT MAXIMUM SPACING BETWEEN DAMS PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE DOWNSTREAM DAM (SEE DIAGRAM ABOVE). Maintenance Ins} ed check &anis and chamelsat lemmeeki), mid aflereach.mpifican1/2 inch or gemez) mmfzE event and repmu immt4±ately.. aeum suit sedimlew, istirm, Iunbs, or odier debns that cuffld clog th,- chamiel vuben needed. Ankipale submergence aml ikposLciu abuwe lime check cbm and elastun A, am, high fiows arcmui the edges cif the, dam- CaTrectaill daiamp immrdmiely. If siguilkantercigion occurs Lxzvecm 1-mr, addihomil nwimgiuvs can I'm naken such as, histalling, a proi rips ap finer in dhit portion of the chancel Renwve iedimeri icuumlated behlmd the d2nis as needed to pre%vut d2mage to chamiel %legetatLon, mflmv the chai to drain dacugh the stmw check- dam-4 aEd Fyievent large flows frorn rarrpng sedinimt over die, dam. Add stores, to dims as needed to manntiin ilem,gh p bets, t ancl cross sectm. TEMPORARY ROCK CHECK DAM NOT TO SCALE 50'-0" (MINIMUM) RIGHT-OF-WAY 6'-0" 181-0ll 1 6'-0" 5�-O" SHOULDER PAVEMENT SHOULDER DITCH 1/4" PER FT. (TYP.) 1/4" PER FT. (TYP.) PROP. DITCH TO BE 0 INSTALLED ON BOTH ()QB .08 SIDES OF ROAD (REFER TO PLAN B C L4 SHEETS) 4'-0" EOP WATER MAIN NOTES: PAVEMENT STRUCTURE WITHIN NCDOT R/W PAVEMENT STRUCTURE OUTSIDE NCDOT R/W (FROM OLD MILL RD EOP TO EXISTING R/W) (INTERNAL TO DEVELOPMENT) 1. SUBGRADE SHALL BE COMPACTED TO A DENSITY OF 100% IN OA 3" - S9.5C (FINAL 1 1/2" NOT TO OA 1 1/2" BITUMINOUS CONCRETE SURFACE COURSE, S9.5B ACCORDANCE WITH AASHTO-T99 AND NCDOT SPECIFICATIONS BE INSTALLED UNTIL 80% BUILDOUT) SECTION 500. @ 3" - 119.00 @ 1 1/2" BITUMINOUS CONCRETE SURFACE COURSE, S9.5B 2. AGGREGATE BASE COURSE SHALL BE COMPACTED TO A DENSITY 10" COMPACTED AGGREGATE BASE COURSE OR 5" OF 100%. 5" - B25.00 BITUMINOUS CONCRETE BASE COURSE, B25.00 3. ASPHALT COMPACTION SHALL BE IN ACCORDANCE WITH NCDOT SECTION 610. 4. IF REQUIRED BY THE TOWN, TESTS SHALL BE CONDUCTED BY AN INDEPENDENT TESTING FIRM AT THE DEVELOPERS EXPENSE. 5. FINAL LIFT OF PAVEMENT SHALL NOT BE PLACED UNTIL AFTER 80% OF HOME SITES ARE DEVELOPED. THE FINAL LIFT OF PAVEMENT SHALL NOT BE PLACED FOR STREETS THAT WILL BE CLOTH USED TO ACCESS FUTURE PHASES UNTIL THOSE PHASES REACH 80% BUILD -OUT. TYPICAL SECTION RESIDENTIAL LOCAL STREET W1 SHOULDER AND DITCH. (FROM TOWN OF WEDDINGTON STD NO. 100 (SEPT 2014)) FLOW COMPACTED BERM SIDE SLOPE (3:1 TYP.) - MAY BE REQUIRED FINISH GRADE --i NATURAL GROUND PUMP DISCHARGE HOSE - A14 7-Ij GRo FLOW \- DEPTH OF PERMANENT DITCH (1.5 FT) BOTTOM WIDTH (SEE CHART THIS SHEET) J (UNLESS OTHERWISE NOTED) (SEE TABLES THIS SHEET) PERMANENT NON -ROADSIDE DITCH SHOULDER (VARIES SEE DRAWINGS) FINISH on.- - -- COMPACTED 1 FT BERM @ 3:1 MAYBE REQUIRED / " A7*U < KNI K P,4L GROUND FORE SLOPE 3:1 TYP BACK SLOPE 3:1 TYP N DEPTH OF PERMANENT DITCH (1.5 FT) BOTTOM WIDTH (1 FT) (UNLESS OTHERWISE NOTED) (UNLESS OTHERWISE NOTED) (SEE TABLES THIS SHEET) (SEE TABLES THIS SHEET) PERMANENT ROADSIDE DITCH NOTE: 1. DITCH SHOULD HAVE MINIMUM LONGITUDINAL SLOPE OF 0.5%. 2. SILT FENCE MAY BE REQUIRED BEHIND BERM. 3. STABILIZE, SEED, AND MULCH IMMEDIATELY AFTER INSTALLATION. 4. LINERS SELECTED SHALL MEET OR EXCEED REQUIRED SHEAR STRESS SHOWN IN TABLE BELOW. MAINTENANCE NOTE: INSPECT PERMANENT DIVERSIONS AFTER EVERY RAINFALL DURING THE CONSTRUCTION OPERATION. IMMEDIATELY REMOVE ANY OBSTRUCTIONS FROM THE FLOW AREA, AND REPAIR THE DIVERSION RIDGE. CHECK OUTLETS, AND MAKE TIMELY REPAIRS AS NEEDED. MAINTAIN THE VEGETATION IN A VIGOROUS, HEALTHY CONDITION AT ALL TIMES. DEPTH (FT) TOP WIDTH (FT) *BOTTOM WIDTH (FT) SIDE SLOPE (H:V) CHANNEL LINING TYPE SHEAR STRESS (PS F) SLOPE (FT/FT) AREA (ACRES) LENGTH (FT) PD #1 1.50 10.00 1.0 3 STRAW W/ NET 1.17 0.050 0.91 210 PD #2 1.50 10.00 1.0 3 SYNTHETIC MAT* 1.96 0.071 1.40 311 PD #3 1.50 10.00 1.0 3 STRAW W/ NET 0.41 0.011 0.58 98 PD #4 1.50 10.00 1.0 3 SYNTHETIC MAT* 1.28 0.038 2.27 296 PD #5 1.50 10.00 1.0 3 STRAW W/ NET 0.81 0.055 0.14 202 PD #6 1.50 10.00 1.0 3 SYNTHETIC MAT* 1.23 0.111 0.21 314 PD #7 1.50 10.00 1.0 3 STRAW W/ NET 0.87 0.083 0.09 112 PD #8 1.50 10.00 1.0 3 STRAW W/ NET 0.89 0.055 0.17 201 PD #9 1.50 10.00 1 1.0 3 STRAWW/NET 0.46 1 0.006 1 4.111 40 PD#10 1.50 10.00 1 1.0 3 STRAW W/ NET 0.45 1 0.010 1 1.64 363 *SYNTHETIC MAT SHALL BE AMERICAN EXCELSIOR CURLEX 11 MAT OR APPROVED EQUAL PERMANENT DITCH NOT TO SCALE 46, tC A EA 043852 1VxIQM&(.REED 8020 Tower Point Drive Charlotte, North Carolina 28227 Phone: (704) 841-2588, Fax: (704) 841-2567 NC License# F-1222 www.mckimcreed.com SILT BAG 12 IN MIN. ULCH, LEAF/WOOD COMPOST, PLAN VIEW WOODCHIPS, SAND, OR STRAW BALES STRAP SLOPE 5% MAX. ELEVATION ` FILTER BAG L8 IN MIN. CONSTRUCTION SPECIFICATIONS 1. TIGHTLY SEAL SLEEVE AROUND THE PUMP DISCHARGE HOSE WITH A STRAP OR SIMILAR DEVICE. 2. PLACE FILTER BAG ON SUITABLE BASE (E.G., MULCH, LEAF/WOOD COMPOST, WOODCHIPS, SAND, OR STRAW BALES) LOCATED ON A LEVEL OR 5% MAXIMUM SLOPING SURFACE. DISCHARGE TO A STABILIZED AREA. EXTEND BASE A MINIMUM OF 12 INCHES FROM EDGES OF BAG. 3. CONTROL PUMPING RATE TO PREVENT EXCESSIVE PRESSURE WITHIN THE FILTER BAG IN ACCORDANCE WITH THE MANUFACTURER RECOMMENDATIONS. AS THE BAG FILLS WITH SEDIMENT, REDUCE PUMPING RATE. 4. REMOVE AND PROPERLY DISPOSE OF FILTER BAG UPON COMPLETION OF PUMPING OPERATIONS OR AFTER BAG HAS REACHED CAPACITY, WHICHEVER OCCURS FIRST. SPREAD THE DEWATERED SEDIMENT FROM THE BAG IN AN APPROVED UPLAND AREA AND STABILIZE WITH SEED AND MULCH BY THE END OF THE WORK DAY. RESTORE THE SURFACE AREA BENEATH THE BAG TO ORIGINAL CONDITION UPON REMOVAL OF THE DEVICE. 5. USE NONWOVEN GEOTEXTILE WITH DOUBLE STITCHED SEAMS USING HIGH STRENGTH THREAD. SIZE SLEEVE TO ACCOMMODATE A MAXIMUM 4 INCH DIAMETER PUMP DISCHARGE HOSE. THE BAG MUST BE MANUFACTURED FROM A NONWOVEN GEOTEXTILE THAT MEETS OR EXCEEDS MINIMUM AVERAGE ROLL VALUES (MARV) FOR THE FOLLOWING: GRAB TENSILE 250 LB ASTM D-4632 PUNCTURE 150 LB ASTM 0-4833 FLOW RATE 70 GAL/MIN/Fr ASTM D-4491 PERMITTIVITY (SEC-1) 1.2 SEC-' ASTM D-4491 UV RESISTANCE 70% STRENGTH 0 500 HOURS ASTM D-4355 APPARENT OPENING SIZE (AOS) 0,15-0.18 MM ASTM D-4751 SEAM STRENGTH 9OX ASTM D-4632 6. REPLACE FILTER BAG IF BAG CLOGS OR HAS RIPS, TEARS, OR PUNCTURES. DURING OPERATION KEEP CONNECTION BETWEEN PUMP HOSE AND FILTER BAG WATER TIGHT. REPLACE BEDDING IF IT BECOMES DISPLACED. FILTER BAG DETAIL. NOT TO SCALE BROOM FINISH jc$L4U V.16� CHAUP15iWCES IN LA40SCAPIE ARFAS T0(X EA ryusH ouh LJ ALWINPIC SUP ES N PAVED AREAS, CIIIJ muhE NU) 1 SURFACE �25 KH PENTOOT ON ALL SIDES FPJR rANN4F r S1 PL WESER PAL) CSU PEOESIAL (orm METAL PEDEIJAL ONLY) ­­-VATCH EX61ING, GRADE It, ("y' �Sx PZEO APEAS cLOPT SUFFVE .25 KH PER F1COT r41' 4,00 14N. LahALL SIDES FOR rAAJNAIr 1 4 M MIN14,00 CID4704S molwim. 16AY -7 MWEL 04 C KI) 5 HED (CMIT AHERE L X 4,100 7 r QUO 7 ROCY !V, MIN AX, FROST CEFTH FRM W SOJI OR WELLUWSTJRf1 COUVACTED SOUL. 1, C04CRETE vAkL HAVE A CDWIRES!jw,E OF 10X 111.4 �b'. MW R.Ai REDHEAD WAWLT wv w farmsal-tedbtad,corl) 0 28 DAYS, CONTAIN 4Z MIN. - 6,% MAX, AN ENTRAVIVENT AND CALIOANIZET� 1/2' COUVER x 7 NtYALL LENCI)t CATALO' , AL� ii 11 '401 4� 'LUMP IN Y= 1AITH k' 'in HE PLACED '01RH A 115 -4A$0 S NbUBF-R., 'OtS-1270G 2" RENFORCK,S11EEL RODS SHAL CONFORY TO ASTU A05. GRADE 60. N54RE IHAI THE MAIN. EMBEDMENT IN CONCREIE 6 AT I.Ek7� '�Q;T Or HL11 KWIK BOLT 11-1/2" DIAMETER x 5-1/2" CARALL LEWJH C RAAL STUV CALVAMM, CATALCC 4z 00O-453-696 CJLVANIZED, 1/2' WWI& W, �-112' NERALL UENCIIH; CkTAI KIT 11 12-512� STAINLESS SIIEEL� CATALOG #� 033-04-744 NvvmER. 7124 ENSURE THAT THE WIN, EMBEDMENT IN COMCRETE IS Al LEAST 3-1/2', ENSURE 1HA7 THE MIN. NaEDVDIT 1*4 CONCRETE IS AT LEAST E R BOX UNIT (CB,U) IN STAL LATON �SINGLE UNIT G 1 - rAr, � F7W 0 Y12� 2 Z2i JUmallbWVAMeb/01-Z� re6 rc'�' 1 /2' T-0- 71��­-­-I VSK Srdt 4.vx,& EXISTING SAND THE WORK SHALL CONSIST OF INSTALLING A PUMP AROUND MEN CONSTRUCTION ACTIVITIES TAKE PLACE WITHIN THE STREAM CHANNEL. 11. MATERIAL SPECIFICATIONS SANDBAGS: SANDBAGS SHALL CONSIST OF MATERIALS WHICH ARE RESISTANT TO ULTRAVIOLET RADIATION, TEARING AND PUNCTURE, AND WOVEN TIGHTLY ENOUGH M PREVENT LEAKAGE OF FILL MATERIAL (i.e., SAND, FINE GRAVEL ETC.). III. CONSTRUCTION REQUIREMENTS 1. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSTALLED AS THE FIRST ORDER OF WORK. 2. THE HEIGHT OF THE SANDBAGS SHALL BE AS INDICATED IN SECTION A -A. THE SANDBAGS SHALL BE PLACED ON A SMOOTH PREPARED SURFACE. 3. ALL EXCAVATED MATERIALS SHALL BE DISPOSED OFF OUTSIDE THE 100 YEAR FLOOD PLAIN UNLESS APPROVED ON THE PLANS BY THE WRA. 4. ALL DEWATERING OF THE CONSTRUCTION AREA SHALL BE PUMPED TO A WRA APPROVED DEVICE. 5. THE PUMP SHALL BE OF SUFFICIENT SIZE TO CONVEY NORMAL STREAM FLOW. 6. SEDIMENT CONTROL DEVICES ARE M REMAIN IN PLACE UNTIL ALL DISTURBED AREAS ARE STABILIZED AND THE INSPECTING AUTHORITY APPROVES THEIR REMOVAL. STREAM CROSSING CONSTRUCTION SEQUENCE: 1. CONTRACTOR SHALL SELECT A PROPOSED SIZE AND LOCATION FOR THE SILT BAG AND SEEK APPROVAL FROM NCDEQ INSPECTOR PRIOR TO INSTALLATION. 2. INSTALL SILT BAG AS APPROVED BY NCDEQ INSPECTOR. 3. INSTALL UPSTREAM PUMP AND TEMPORARY FLEXIBLE HOSE TO OUTLET DOWNSTREAM OF PROPOSED STREAM WORK BUT WITHIN THE LIMITS OF DISTURBANCE. 4. PLACE UPSTREAM IMPERVIOUS DIKE AND BEGIN PUMPING OPERATIONS FOR STREAM DIVERSION. 5. PLACE DOWNSTREAM IMPERVIOUS DIKE AND INSTALL PUMPING APPARATUS TO DEWATER THE ENTRAPPED AREA. 6. INSTALL THE PROPOSED PERMANENT CULVERTS IN ACCORDANCE WITH THE PLANS WHILE MAINTAINING THE PUMP AROUND OPERATION. CONTRACTOR SHALL ENSURE THAT IN -STREAM WORK IS CONDUCTED IN THE DRY AREA. 7. THE PUMP AROUND AREA IS TO BE STABILIZED WITH MATTING AT THE END OF EACH WORK DAY. 8. AFTER INSTALLATION OF THE CULVERTS IS COMPLETE, ENSURE SITE IS STABLE AND EXCAVATE ANY ACCUMULATED SILT BEFORE REMOVAL OF IMPERVIOUS DIKES. REMOVE IMPERVIOUS DIKES, PUMPS, AND TEMPORARY FLEXIBLE HOSE. (DOWNSTREAM IMPERVIOUS DIKE FIRST). 9. DIVERT STREAM FLOW THROUGH THE CONSTRUCTED CULVERT. 10. REMOVE SILT BAG AND PROPERLY DISPOSE OF CAPTURED SEDIMENT AND SILT BAG. STABILIZE DISTURBED AREAS WITH SEED AND MULCH. 11. BEGIN FILL OF ROADWAY BED. 12. CONTRACTOR TO ENSURE ALL WORK AND DISTURBANCE FALLS WITH THE LIMITS OF DISTURBANCE. STREAM PUMP AROUND. NOT TO SCALE BELLE MAR RESIDENTIAL 0 OLD MILL ROAD TOWN OF WEDDINGTON, NC GENERAL DETAILS r- DATE: MAY 2021 MCE PROJ. # 07780-0013 DRAWN JPM DESIGNED JPM CHECKED PMN PROJ. MGR. PMN IIIII&I14fail I m HORIZONTAL N/A VERTICAL: N/A C8.1 DRAWING NUMBER B REVISION STATUS: PRELIMINARY DRAWING NOT FOR CONSTRUCTION 1:\07780\0013\PDNR\80-DWG\86-DESIGN\PLAN SHEETS\C8.0 DETAILS.DWG - - - - 09/10/2021 16:27:04 INFLOW DITCH RIPRAP SLOPE PROTECTION AT INFLOW (1.25' THICK CLASS B RIPRAP) RIPRAP SLOPE PROTECTION AT BASIN INFLOW NTS 100 YR-24 HR = 686.25'- 10 YR-24 HR = 685.25' 1 YR-24 HR = 684.41' BPE B ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDEQ 0911012021 A ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDOT 0810412021 REV.NO. DESCRIPTIONS DATE REVISIONS HAND CRANK FOR DRAIN VALVE TO EXTEND V ABOVE TRASH RACK TOCS I VWE CP a 8" DIP DRAIN CONCRETE BASE SHALL BE MINIMUM OF 62 CF AND BE CONNECTED TO RISER PER STRUCTURAL SHOP DRAWINGS NFK1A4&CKhED 8020 Tower Point Drive Charlotte, North Carolina 28227 Phone: (704) 841-2588, Fax: (704) 841-2567 NC License# F-1222 www.mckimcreed.com AIVI MUK 1 SE le 9.0' N.T.S. TRASH RACK DETAIL SIDE VIEW N.T.S. 2"x2"x114" ANGLE IRON ..r..,.._.. _.,.� ..PRESENTS ACCESS HATCH TO BE CONSTRUCTED BY TRASH oo(-ir PAMDI(-oTr)R. HATCH SHALL )VER STEPS NOTES: 1. ALL REBAR TO BE #4 REBAR. 2. ALL REBAR AND ANGLE IRON TO BE HOT -DIPPED GALVANIZED AND COATED WITH EPDXY. 3. CONTRACTOR SHALL ANCHOR TRASH RACK TO STRUCTURE WALL WITH FOUR (4) 4"x114" CONCRETE ANCHOR BOLTS THROUGH ANGLE IRON. 4. ACCESS HATCH SHALL ALIGN WITH STEPS IN STRUCTURE. SEE PLAN TRASH RACK (SEE DETAIL) 1 3 OUTLET CONTROL STRUCTURE (SEE DETAIL) OPE-1 L6 5.5' D t' D LO 0 0 t, i 24" D t' 5' I II 11 // 0 D o D o 1' THICK 4000 PSI CONCRETE #5 EW. E.F #5 EW. E.F NOTE: COLLAR MUST PROJECT 1.5' MIN. FROM BARREL ANTI -SEEP COLLAR DETAIL N.T.S. le 5.0' 4000 PSI CONCRETE (MIN. 28-DAY STRENGTH) ° 4 ° 0.5' 4.0' ° a ° a ° O-RING RCP BARREL CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 12" O.C. OUTLET CONTROL STRUCTURE DETAIL TOP VIEW N.T.S. NOTES: 1. EXISTING POND TO BE DE -WATERED PRIOR TO CONVERSION TO DETENTION POND. REFER TO CONSTRUCTION SEQUENCE ON DRAWING C1.1 FOR FURTHER DETAIL. 2. DAM MATERIAL AND COMPACTION REQUIREMENTS ARE TO BE FIELD DETERMINED BY GEOTECHNICAL ENGINEER. ALL WORK REGARDING THE DAM EMBANKMENT MUST BE MONITORED AND APPROVED BY GEOTECHNICAL ENGINEER. 3. AN AS -BUILT SURVEY AND ENGINEER'S CERTIFICATION WILL BE REQUIRED STATING THAT THE POND IMPROVEMENTS MEET THE REQUIREMENTS OF THE TOWN'S STORMWATER/DETENTION ORDINANCE. 4. A GEOTECHNICAL REPORT FOR DAM IMPROVEMENTS AND ENGINEER'S CERTIFICATION FOR SATISFACTORY COMPLETION OF CONSTRUCTION IS REQUIRED PRIOR TO PROJECT CLOSEOUT. TOD 24" O-RING RCP 3 1 `ANTI -SEEP COLLARS J 2 COLLARS, 6 FT SPACING, 5'X5' SIZE (SEE DETAIL) DETENTION POND — SECTION NTS 3.0' TOCS 6" (TYP) 684.75' 1.0' VWE CPE DIP ELBOW 4(TYP) (SEE DETAIL) STEPS AT 12" MAX SPACING OPE-1 1 � Z-1"BASE MIN. THICKNESS I 6' I OUTLET CONTROL STRUCTURE - FRONT VIEW N.T.S. 6" (I.D.) DIP a WITH 90° BEND, PAINT WITH SILVER CORROSION -RESISTANT PAINT a a SCREW -ON CAP WITH 3.0" 0 ° ORIFICE INSIDE e a OF STRUCTURE a G ° a END OF PIPE TO BE INSTALLED 12" BELOW PERMANENT POOL ELEVATION CHANNEL PROTECTION ORIFICE DETAIL N.T.S. DETENTION POND ELEVATION INFORMATION PERMANENT POND ELEVATION PPE 684.00' BOTTOM OF POND ELEVATION BPE 677.00' TOP OF DAM ELEVATION TOD 688.00' OUTLET PIPE UPSTREAM INVERT ELEVATION OPE-1 677.00' OUTLET PIPE DOWNSTREAM INVERT ELEVATION OPE-2 676.55' VOLUME WEIR INVERT ELEVATION VWE 684.25' CHANNEL PROTECTION ORIFICE DIAMETER CPD 3.0" CHANNEL PROTECTION ORIFICE INVERT ELEVATION CPE 684.00' TOP OF OUTLET CONTROL STRUCTURE ELEVATION TOCS 686.50' SEE PLAN BELLE MAR RESIDENTIAL 0 OLD MILL ROAD TOWN OF WEDDINGTON, NC BMP DETAILS MAINTAIN MIN. 1' OF COVER OVER PIPE DATE: MAY 2021 MCE PROJ. # 07780-0013 DRAWN JPM DESIGNED JPM CHECKED PMN PROJ. MGR. PMN FLARED END SECTION OPE-2 RIPRAP OUTLET PROTECTION HORIZONTAL N/A VERTICAL: N/A C8.3 DRAWING NUMBER GN REVISION >TATus: PRELIMINARY DRAWING NOT FOR CONSTRUCTION I:\07780\0013\PDNR\80—DWG\86—DESIGN\PLAN SHEETS\C8.0 DETAILS.DWG ---- 09/10/2021 16:27:19 2-3/8" DIAMETE^ ^^ T 2" MESH CHAIN LINK FABRIC WOVEN FILTER FABRIC 8' MAX. 2-3/8" DIAMETER POSTS V " MESH CHAIN LINK FABRIC z gLTER FABRIC J#5 OR #57 WASHED STONE Of m Q 'j FLOW N t.\\� 0 4" ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT BACKFILL GENERAL NOTES: MAINTENANCE NOTES: 1. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO REMAIN 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY FOR A PERIOD OF MORE THAN 30 DAYS. RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. 2. STEEL POSTS SHALL BE 2-3/8" DIAMETER AND 5-0" IN HEIGHT. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 3. WIRE FENCING SHALL BE 2" MESH CHAIN LINK FABRIC. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE 4. TURN SILT FENCE UP SLOPE AT ENDS. BARRIER STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 5. WIRE AND WASHED STONE IS REQUIRED TO BE SHOWN ON PLANS AT THE TOE OF SLOPES GREATER THAN 10 FEET VERTICAL (2: 1 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS SLOPE) REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS 6. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING WHEN GRADING IS ADJACENT TO SWIM BUFFERS, STREAMS OR GRADE, PREPARED AND SEEDED. WETLANDS (REFER TO SWIM BUFFER GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 7. DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 8. DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. 2-3/8" ......�� 2" MESH CHAIN LINK WOVEN FILTER GENERAL NOTES: REINFORCED SILT FENCE (SUPER SILT FENCE) INSTALLATION SPECIFICATIONS AND MAINTENANCE 4' MAX. 1. SEDIMENT FILTER OUTLET AND HARDWARE CLOTH SHALL BE 16 INCHES HIGH BUT NO TALLER THAN 18 INCHES. 2. HARDWARE CLOTH SHALL BE ANCHORED TO THE POSTS SECURELY USING APPROPRIATE ANCHORS. HARDWARE CLOTH SHALL BE KEYED IN A MINIMUM OF 12 INCHES IN LENGTH AND BACKFILLED PROPERLY AS SHOWN IN ABOVE DETAIL. HARDWARE CLOTH TO BE 19 GAUGE, 1 /4" SPACING. 3. POSTS SHALL BE NO MORE THAN 4 FEET APART. 4. SITE OUTLETS AT ANY POINT SMALL CONCENTRATED FLOWS ARE ANTICIPATED AND AT THE DIRECTION OF THE INSPECTOR. 5. ONE ACRE MAXIMUM DRAINAGE AREA PER OUTLET. 2-3/8" DIAMETER POSTS HARDWARE CLOTH WASHED STONE (NCDOT #5 OR #57) FLOW ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT BACKFILL MAINTENANCE NOTES: 1. FILTER OUTLETS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. THE STONE SHALL BE REPLACED PROMPTLY AFTER ANY EVENT THAT HAS CLOGGED OR REMOVED IT. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OUTLET IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. REINFORCED SILT FENCE (SUPER SILT FENCE) OUTLET DEVICE INSTALLATION SPECIFICATIONS AND MAINTENANCE - EA t4 : z, vNFK1A4&C_MEjj 8020 Tower Point Drive Charlotte, North Carolina 28227 Phone: (704) 841-2588, Fax: (704) 841-2567 NC License# F-1222 www.mckimcreed.com #5 WASHED STONE - 1' THICK x THIGH (MIN.) NCDOT #5 OR #57 WASHED STONE F0 W GENERAL NOTES: \< O rl OCC R RIP PAP PERSPECTIVE VIEW r1ol 8' MINIMUM SECTION ,1»1►1y/:lC4ODALTA /J:l RIP RAP HEADWALL, 1' MIN CLASS B RIP RAP HEIGHT FROM ROAD SHOULDER / FINISH GRADE 1. GRAVEL AND RIP RAP FILTER BERM BASIN SHOULD BE USED TO PROTECT PIPE INVERTS THAT DRAIN 10 ACRES OR LESS. 2. DIMENSIONS SHOWN ARE THE MINIMUM ACCEPTED UNLESS OTHERWISE NOTED. 3. IN LIEU OF RING FILTER, THE OUTLET PIPE MAY BE COVERED WITH HARDWARE CLOTH, RIP RAP AND WASHED STONE WHERE A SPILLWAY IS NOT REQUIRED. LTA Fail ILl III I=1Ll Fail Ll[4:111111Ll16119*5 INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (112 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIPRAP DISPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. AFTER ALL THE SEDIMENT PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER. ROCK PIPE INLET PROTECTION NOT TO SCALE ALTERNATE WALL CONFIGURATION - I _I PLAN 3.1 SCOPE T a �T SECTION SEE STD. 20.23 AND 20.24 o -14 _�Tj E ITI _ TABLE OF DIMENSIONS D T A B c E L WT, 12" 2-1/4" 4" 2'-0- 4'-1" 2'-0' 6'-l' 730 15" 2-1/4" 6" 2'-3" 3'-10" 2'-0- 6'-1' 730 18" 2-1/2" 9" 2'-3" V-10" 3'-0- 6'-1' 1190 24" 3" 10" 3'-8" 2'-6" 4'-0' 6'-2- 1770 30" 3-1/2" l'-O" 4'-6" l'-8" 5'-0' 6'-2' 2380 38" 4" l'-3" 5'-3" 2'-11" 8'-O" 8'-2' 5320 42" 4-1/2" V-9" 5'-3" 1 2'-11" 6'-6" 8'-2" 5920 48" 5" 2'-0' 6'-0' 2'-2" 7'-0' 8'-2 7470 54' 5-1/2" 2'-3" 5'-6" 2'-10" 7'-8" 8'-4' Salo 60" 6" 2'-6" 5'-0" 3'-3" 8'-0" 8'-3' 11180 66" 6-1/2" 3'-0" 6'-0" 2'-3" 8'-6" 8'-3' 12530 72" 7" 1 3'-0" 6'-6" 1'-9" 9'-O" 8'-3" 13980 GENERAL NOTES: 1. SEE FORMER NCDOT STANDARD 310.01 FOR DETAILS. 2. REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF REINFORCED CONCRETE PIPE OF UKE DIAMETER PER AASHTO M170, TABLE 2, WALL B. 3. ALL CONCRETE TO BE 3600 P.S.I COMPRESSIVE STRENGTH. 4. PROVIDE TONGUE OR SPIGOT JOINT AT INLET END SECTION. 5. PROVIDE GROOVE OR BELL JOINT AT OUTLET END SECTION. 6. THE DIMENSIONS FOR END SECTIONS SHALL SUBSTANTIALLY AGREE WITH THE TABLE. MINOR VARIATIONS WILL BE PERMITTED BASED ON THE MANUFACTURER'S STANDARD FORMS AND TEMPLATES. 7. NOT TO BE USED IN NCDOT MAINTAINED RIGHT OF WAY. END VIEW NOT TO SCALE FLARED END SECTION DETAIL NOT TO SCALE Construction 1. Ensure that the subgrade for the filter and riprap follows the required lines and grades shown in the plan. Compact any fill required in the subgrade to the Specifications density of the surrounding undisturbed material. Low areas in the subgrade on undisturbed soil may also be filled by increasing the riprap thickness. 2. The riprap and gravel filter must conform to the specified grading limits shown on the plans. 3. Filter cloth, when used, must meet design requirements and be properly protected from punching or tearing during installation. Repair any damage by removing the riprap and placing another piece of filter cloth over the damaged area. All connecting joints should overlap so the top layer is above the downstream layer a minimum of 1 foot. If the damage is extensive, replace the entire filter cloth. 4. Riprap maybe placed by equipment, but take care to avoid damaging the filter. 5. The minimum thickness of the riprap should be 1.5 times the maximum stone diameter. 6. Riprap may be field stone or rough quarry stone. It should be hard, angular, highly weather -resistant and well graded. 7. Construct the apron on zero grade with no overfill at the end. Make the top of the riprap at the downstream end level with the receiving area or slightly below it. 8. Ensure that the apron is properly aligned with the receiving stream and preferably straight throughout its length. If a curve is needed to fit site conditions, place it in the upper section of the apron. 9. Imm ediately after construction, stabilize all disturbed areas with v egetation (Practices 6. 10, Temporary Seeding, and 6.11, Permanent Seeding). Maintenance Inspect riprap outlet structures weekly and after significant (1 /2 inch or greater) rainfall events to see if any erosion around or below the riprap has taken place, or if stones have been dislodged. Immediately make all needed repairs to prevent further damage. OUTLET STABILIZATION STRUCTURE SPECIFICATIONS AND MAINTENANCE RIPRAP TO EXTEN[ TOP JB d0 SILT FENCE TO E INSTALLED OVE TOP OF FE SILT FENCE CHANNEL VV BOTTOM D OUTLET NO. Do (FT.) La (FT.) W (FT.) DEPTH (IN.) LINING CLASSIFICATION CWD #2 1.0 8 9 6.0 CLASS A TDD #4 & #8 (EC 3) 1.0 8 9 6.0 CLASS A CULVERT #1 1.50 10 12 9.6 CLASS A CULVERT #2 1.50 9 11 9.6 CLASS A CULVERT #3 1.25 8 9 6.0 CLASS A CULVERT #4 1.50 9 11 9.6 CLASS A POND OUTLET 2.00 13 15 10.8 CLASS A STONE CLASSIFICATIONS OF CLASS A REQUIRE A SUBLAYER OF FILTER FABRIC OR FS-2 FILTER STONE WITH A BEDDING THICKNESS OF 6". RIPRAP OUTLET PROTECTION DETAIL NOT TO SCALE BELLE MAR RESIDENTIAL 0 OLD MILL ROAD TOWN OF WEDDINGTON, NC DATE: MAY 2021 MCE PROJ. # 07780-0013 DRAWN JPM DESIGNED JPM CHECKED PMN PROJ. MGR. PMN HORIZONTAL N/A VERTICAL: N/A C8.4 DRAWING NUMBER GN REVISION B ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDEQ 091101202 1 A ADDRESSED COMMENTS FROM TOWN OF WEDDINGTON AND NCDOT 081041202 1 REV.NO. I DESCRIPTIONS I DATE I:\07780\0013\PDNR\80-DWG\86-DESIGN\PLAN SHEETS\C8.0 DETAILS.DWG ---- 09/10/2021 16:27:24 GENERAL DETAILS STATUS: PRELIMINARY DRAWING NOT FOR CONSTRUCTION