Loading...
HomeMy WebLinkAboutNCG020173_Inspection Report_20210603 6 Compliance Inspection Report Permit:NCG020173 Effective: 05/06/21 Expiration: 06/30/21 Owner: Martin Marietta Materials Inc SOC: Effective: Expiration: Facility: Martin Marietta-Mallard Creek County: Mecklenburg 575 E Mallard Creek Church Rd Region: Mooresville Charlotte NC 28213 Contact Person:Jay Nivens Title: Phone:704-409-1475 Directions to Facility: System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 06/03/2021 Entry Time 03:OOPM Exit Time: 04:OOPM Primary Inspector:Jeffrey A Chandler Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: N Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 permit: NCG020173 Owner-Facility:Martin Marietta Materials Inc Inspection Date: 06/03/2021 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: Mine is in compliance. General Housekeeping is necessary surronding the shop onsite and maps need to be updated with new landowners and leasers surronding the mine site. Page 2 of 3 n e , Permit: NCG020173 Owner-Facility:Martin Marietta Materials Inc Inspection Date: 06/03/2021 Inspection Type:Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ #Does the Plan include a General Location(USGS)map? N ❑ ❑ ❑ #Does the Plan include a"Narrative Description of Practices"? N ❑ ❑ ❑ #Does the Plan include a detailed site map including outfall locations and drainage areas? 0 ❑ ❑ ❑ #Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ #Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ #Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ #Does the Plan include a BMP summary? 0 ❑ ❑ ❑ #Does the Plan include a Spill Prevention and Response Plan(SPRP)? E ❑ ❑ ❑ #Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? N ❑ ❑ ❑ #Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ #Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ #Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ #Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: SWPPP needs to be reviewed and updated annually. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? N ❑ ❑ ❑ #Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE #Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ #Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ #If the facility has representative outfall status,is it properly documented by the Division? ❑ ❑ N ❑ #Has the facility evaluated all illicit(non stormwater)discharges? ❑ ❑ 0 ❑ Comment: Page 3 of 3